1 EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 14 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:221.7V I:.493A P:15.3W PF:.927 Lamp Flux:1318.7x1 lm NAME: ASD-LSB1P-1D5PRM SUR.:29*17mm DATA OF LAMP PHOTOMETRIC DATA Eff: lm/w MODEL ASD-LSB1P-1D5PRM Imax(cd) 4451 S/MH(C/18) 1.64 NOMINAL POWER(W) 1 LOR(%) 1. S/MH(C9/27) 1.81 RATED VOLTAGE(V) 222 TOTAL FLUX(lm) 1319 η UP,DN(C-18) 1.1,61.7 NOMINAL FLUX(lm) CIE CLASS DIRECT η UP,DN(C18-36) 1.5,35.7 LAMPS INSIDE 1 η up(%) 2.5 CIBSE SHR NOM 1.5 TEST VOLTAGE(V) η down(%) 97.5 CIBSE SHR MAX 1.55 LUMINOUS INTENSITY DISTRIBUTION DIAGRAM C PLANE ISOLUX DIAGRAM (UNIT:lx) MH(m) / UNIT:cd C/18,156.2 C3/21, C6/24,96.5 C9/27,84.9 AVERAGE BEAM ANGLE(5%):119.2 DEG S(m) C Range: - 36DEG C Interval: 5.DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-2B_V1 SYSTEM V Humidity:65.% Test Distance:8.m [K=.7188]
2 EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 2 Of 14 ZONAL FLUX DIAGRAM ZONAL FLUX DIAGRAM: C C45 C9 C135 C18 C225 C27 C315 Φ zone Φ total %lum,lamp , , , , , , , , , , , , , , , , , ,1 DEG LUMINOUS INTENSITY:cd UNIT:lm C Range: - 36DEG C Interval: 5.DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-2B_V1 SYSTEM V Humidity:65.% Test Distance:8.m [K=.7188]
3 EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 3 Of 14 CU AND LUMINAIRE BUDGETARY ESTIMATE DIAGRAM Test:U:221.7V I:.493A P:15.3W PF:.927 Lamp Flux:1318.7x1 lm NAME: ASD-LSB1P-1D5PRM SUR.:29*17mm ρ cc ρ w ρ fc RCR % 7% 5% 3% 5% 3% 1% 5% 3% 1% 5% 3% 1% 5% 3% 1% 2% 2% 2% 2% RCR:Room Cavity Ratio Coefficients of Utilization(CU) % 5% 3% 1% 2% LAMPS 5 LUMINAIRE BUDGETARY DIAGRAM H=7 H= k AREA(m2) CONDITIONS FLUX 5lm FACTOR.7 Hdown.m Hwork.m Ework(AVE) 1lx ρ (%) cc w fc k 3k 4k 5k 7k C Range: - 36DEG C Interval: 5.DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-2B_V1 SYSTEM V Humidity:65.% Test Distance:8.m [K=.7188]
4 EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 4 Of 14 WEC AND CCEC Test:U:221.7V I:.493A P:15.3W PF:.927 Lamp Flux:1318.7x1 lm NAME: ASD-LSB1P-1D5PRM SUR.:29*17mm ρ cc ρ w ρ fc RCR 8% 7% 5% 3% 1% 5% 3% 1% 2% 2% RCR:Room Cavity Ratio 5% 3% 5% 3% 1% 5% 3% 1% 2% 2% Wall Exitance Coeffcients(WEC) 1% 5% 3% 1% 2% ρ cc ρ w ρ fc RCR % 7% 5% 3% 1% 5% 3% 1% 5% 3% 1% 5% 3% 1% 5% 3% 1% 5% 3% 1% 2% 2% 2% 2% 2% RCR:Room Cavity Ratio Ceiling Cavity Exitance Coefficients(CCEC) C Range: - 36DEG C Interval: 5.DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-2B_V1 SYSTEM V Humidity:65.% Test Distance:8.m [K=.7188]
5 EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 5 Of 14 Uncorrected UGR Table Test:U:221.7V I:.493A P:15.3W PF:.927 Lamp Flux:1318.7x1 lm NAME: ASD-LSB1P-1D5PRM SUR.:29*17mm ceiling/cavity walls working plane Room dimensions x = 2H y = 2H 3H 4H 6H 8H 12H Viewed crosswise Viewed endwise H 2H 3H 4H 6H 8H 12H H 4H 6H 8H 12H H 4H 6H 8H Variations with the observer position at spacings: S = 1.H +.1 / / H +.4 / / H +.4 / / -.7 CIE Pub.117 Corrected 1319 lm Total Lamp Luminous Flux.(8log(F/F) = 8.9) C Range: - 36DEG C Interval: 5.DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-2B_V1 SYSTEM V Humidity:65.% Test Distance:8.m [K=.7188]
6 EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 6 Of 14 UTILIZATION FACTORS TABLE Test:U:221.7V I:.493A P:15.3W PF:.927 Lamp Flux:1318.7x1 lm NAME: ASD-LSB1P-1D5PRM SUR.:29*17mm REFLECTANCE Ceiling Walls Working plane ROOM INDEX UTILIZATION FACTORS(PERCENT) k(ri) x RCR = 5 k = ROOM INDEX UF(total) Direct According to DIN EN Suspended SHRNOM = 1.25 C Range: - 36DEG C Interval: 5.DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-2B_V1 SYSTEM V Humidity:65.% Test Distance:8.m [K=.7188]
7 EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 7 Of 14 ISOCANDELA DIAGRAM Test:U:221.7V I:.493A P:15.3W PF:.927 Lamp Flux:1318.7x1 lm NAME: ASD-LSB1P-1D5PRM SUR.:29*17mm % % 89. 3% % 178 5% % 267 7% % 356 9% VERTICAL(DEG) Imax:445(H-63.5,V-21.) (At:C=17.,Gamma=65.) UNIT: cd HORIZONTAL(DEG) C Range: - 36DEG C Interval: 5.DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-2B_V1 SYSTEM V Humidity:65.% Test Distance:8.m [K=.7188]
8 EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 8 Of 14 AAI Figure Test:U:221.7V I:.493A P:15.3W PF:.927 Lamp Flux:1318.7x1 lm NAME: ASD-LSB1P-1D5PRM SUR.:29*17mm Flux out:634 lm 3.281ft 1m 14.9,297.4fc 1516,321lx 7.546ft 23.1cm 6.562ft 2m 35.22,74.34fc 379.1,8.2lx 15.9ft 46.2cm 9.843ft 3m 15.65,33.4fc 168.5,355.7lx 22.64ft 69.3cm 13.12ft 4m 8.84,18.59fc 94.77,2.1lx 3.18ft 92.4cm 16.4ft 5m 5.635,11.89fc 6.65,128.lx 37.73ft 115.4cm Height Eavg,Emax Angle:97.98deg Diameter Note:The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance. C Range: - 36DEG C Interval: 5.DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-2B_V1 SYSTEM V Humidity:65.% Test Distance:8.m [K=.7188]
9 EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 9 Of 14 ISOLUX DIAGRAM Test:U:221.7V I:.493A P:15.3W PF:.927 Lamp Flux:1318.7x1 lm NAME: ASD-LSB1P-1D5PRM SUR.:29*17mm 88.9' 44.4'.' 44.4' 88.9' 111.1' 33.87m 88.9' 27.9m 66.7' 2.32m 3%.961lx.892fc 5% 1.6lx.1487fc 1% 3.2lx.2973fc 3% 9.61lx.892fc 5% 16.lx 1.487fc 44.4' 13.55m 22.2' 6.77m.'.m 22.2' 6.77m 44.4' 13.55m 66.7' 2.32m 88.9' 27.9m 111.1' 33.87m 27.9m 13.55m.m 13.55m 27.9m MOUNTING HEIGHT: 33'(1.m) C Range: - 36DEG C Interval: 5.DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-2B_V1 SYSTEM V Humidity:65.% Test Distance:8.m [K=.7188]
10 EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 14 Planar Illuminance Curve E(lx) Planar Illuminance Curve MH = 1 m C/18 C9/ Distance(m) C Range: - 36DEG C Interval: 5.DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-2B_V1 SYSTEM V Humidity:65.% Test Distance:8.m [K=.7188]
11 EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 11 Of 14 LUMINOUS DISTRIBUTION INTENSITY DATA Test:U:221.7V I:.493A P:15.3W PF:.927 Lamp Flux:1318.7x1 lm NAME: ASD-LSB1P-1D5PRM SUR.:29*17mm Table--1 C(DEG) (DEG) UNIT: cd C Range: - 36DEG C Interval: 5.DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-2B_V1 SYSTEM V Humidity:65.% Test Distance:8.m [K=.7188]
12 EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 12 Of 14 LUMINOUS DISTRIBUTION INTENSITY DATA Test:U:221.7V I:.493A P:15.3W PF:.927 Lamp Flux:1318.7x1 lm NAME: ASD-LSB1P-1D5PRM SUR.:29*17mm Table--2 C(DEG) (DEG) UNIT: cd C Range: - 36DEG C Interval: 5.DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-2B_V1 SYSTEM V Humidity:65.% Test Distance:8.m [K=.7188]
13 EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 13 Of 14 LUMINOUS DISTRIBUTION INTENSITY DATA Test:U:221.7V I:.493A P:15.3W PF:.927 Lamp Flux:1318.7x1 lm NAME: ASD-LSB1P-1D5PRM SUR.:29*17mm Table--3 C(DEG) (DEG) UNIT: cd C Range: - 36DEG C Interval: 5.DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-2B_V1 SYSTEM V Humidity:65.% Test Distance:8.m [K=.7188]
14 EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 14 Of 14 LUMINOUS DISTRIBUTION INTENSITY DATA Test:U:221.7V I:.493A P:15.3W PF:.927 Lamp Flux:1318.7x1 lm NAME: ASD-LSB1P-1D5PRM SUR.:29*17mm Table--4 C(DEG) (DEG) UNIT: cd C Range: - 36DEG C Interval: 5.DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-2B_V1 SYSTEM V Humidity:65.% Test Distance:8.m [K=.7188]
LUMINAIRE PHOTOMETRIC TEST REPORT
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 14 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:221.6V I:.927A P:2.5W PF:.976 Lamp Flux:24837.8x1 lm NAME: ASD-LSB1P-2D5PRM SUR.:29*17mm DATA OF LAMP
LUMINAIRE PHOTOMETRIC TEST REPORT
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 11 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:221.V I:.696A P:149.4W PF:.97 Lamp Flux:17499.6x1 lm NAME: 线线线 15W DIM.: 12*14MM DATA OF LAMP PHOTOMETRIC
LUMINAIRE PHOTOMETRIC TEST REPORT
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 14 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:12.3V I:.8291A P:99.52W PF:.9981 Lamp Flux:11838.3x1 lm DATA OF LAMP PHOTOMETRIC DATA Eff: 118.95 lm/w
LUMINAIRE PHOTOMETRIC TEST REPORT
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 12 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:22.9V I:.179A P:38.7W PF:.976 Lamp Flux:52.12x1 lm DATA OF LAMP PHOTOMETRIC DATA Eff: 134.37 lm/w MODEL
LUMINAIRE PHOTOMETRIC TEST REPORT
Page 1 Of 12 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:23.3V I:.162A P:37.16W PF:.9958 Lamp Flux:2152.56x1 lm DATA OF LAMP PHOTOMETRIC DATA Eff: 57.93 lm/w MODEL SLD-3981P Imax(cd) 791.4 S/MH(C/18) 1.28
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 12 LUMINAIRE PHOTOMETRIC TEST REPORT
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 12 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:23.4V I:.835A P:18.32W PF:.952 Lamp Flux:2845.34x1 lm DATA OF LAMP PHOTOMETRIC DATA Eff: 155.34 lm/w MODEL
LUMINAIRE PHOTOMETRIC TEST REPORT
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 14 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:22.1V I:.696A P:148.2W PF:.967 Lamp Flux:15247.4x1 lm SPEC.:PHILIPS 33 DATA OF LAMP PHOTOMETRIC DATA Eff:
LUMINAIRE PHOTOMETRIC TEST REPORT
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 14 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:22.V I:.475A P:11.9W PF:.975 Lamp Flux:11245x1 lm SPEC.:PHILIPS 33 DATA OF LAMP PHOTOMETRIC DATA Eff:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 14 LED LUMINAIRE PHOTOMETRIC TEST REPORT
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 14 LED LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:22.5V I:.4378A P:94.6W PF:.981 Lamp Flux:6671 lm NAME: 1W LED Eco-Bay DATA OF LAMP PHOTOMETRIC DATA
LUMINAIRE PHOTOMETRIC TEST REPORT
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 14 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:22.3V I:.478A P:12.9W PF:.976 Lamp Flux:1458.4x1 lm SPEC.:PHILIPS 33 DATA OF LAMP PHOTOMETRIC DATA Eff:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 13 ROYAL PACIFIC LTD. LUMINAIRE PHOTOMETRIC TEST REPORT TYPE:LED DIM.: SUR.
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 13 ROYAL PACIFIC LTD. LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:12.5V I:.1196A P:14.3W PF:.9925 Lamp Flux:21.9782x33 lm DATA OF LAMP PHOTOMETRIC DATA
LUMINAIRE PHOTOMETRIC TEST REPORT
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 12 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:12.V I:.149A P:12.41W PF:.9857 Lamp Flux:865.458x1 lm DATA OF LAMP PHOTOMETRIC DATA Eff: 69.74 lm/w MODEL
LUMINAIRE PHOTOMETRIC TEST REPORT
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 12 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:219.9V I:.1833A P:39.18W PF:.9719 Lamp Flux:378.65x1 lm NAME: 4W 4K DATA OF LAMP PHOTOMETRIC DATA Eff:
SHENZHEN BRILLOOP LIGHTING CO.,LTD Page 1 Of 13. LED Floodlight 24W(COB)
SHENZHEN BRILLOOP LIGHTING CO.,LTD Page 1 Of 13 LED Floodlight 24W(COB) BLP FL24W2(4K) Light Output Ratio: 1.% Luminaire Power: 25 W SHR Nominal: 1.25 Calculated using the TM5 SHR Maximum: 1.35 fine grid
LUMINAIRE PHOTOMETRIC TEST REPORT
Luminous Intensity Test Report Page 1 Of 11 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:12.1V I:.663A P:72.14W PF:.9911 Lamp Flux:482.19x1 lm DATA OF LAMP PHOTOMETRIC DATA Eff: 66.57 lm/w MODEL CT-D272PLN
LUMINAIRE PHOTOMETRIC TEST REPORT
Luminous Intensity Test Report Page 1 Of 11 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:12.1V I:.381A P:35.88W PF:.9699 Lamp Flux:3453.19x1 lm DATA OF LAMP PHOTOMETRIC DATA Eff: 96.26 lm/w MODEL CT-D236PBN
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 14 LED LUMINAIRE PHOTOMETRIC TEST REPORT
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 14 LED LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:22.6V I:.2368A P:5.97W PF:.9759 Lamp Flux:3648 lm NAME: 5W LED Eco-Bay DATA OF LAMP PHOTOMETRIC DATA
LUMINAIRE PHOTOMETRIC TEST REPORT
LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:22.V I:.273A P:6W PF:.9 Lamp Flux:4769.96x1 lm SUR.:32mm DATA OF LAMP PHOTOMETRIC DATA Eff: 79.5 lm/w MODEL M5-6-6-3-9 Imax(cd) S/MH(C/18) 1.13 NOMINAL POWER(W)
LUMINAIRE PHOTOMETRIC TEST REPORT
LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:22.V I:.682A P:15.W PF:.92 Lamp Flux:12164.3x1 lm SUR.:41mm DATA OF LAMP PHOTOMETRIC DATA Eff: 81.1 lm/w MODEL M5-6-15-3-9 Imax(cd) 8724 S/MH(C/18) 1.3 NOMINAL
LUMINAIRE PHOTOMETRIC TEST REPORT
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 12 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:12.1V I:.153A P:12.45W PF:.9847 Lamp Flux:873.471x1 lm DATA OF LAMP PHOTOMETRIC DATA Eff: 7.15 lm/w MODEL
LUMINAIRE PHOTOMETRIC TEST REPORT
Page 1 Of 11 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:12.V I:.8492A P:1.8W PF:.9894 Lamp Flux:1334.7x1 lm NAME: XSY-HBP-1W DATA OF LAMP PHOTOMETRIC DATA Eff: 131.98 lm/w MODEL XSY-HBP-1W Imax(cd) 532 S/MH(C/18)
LUMINAIRE PHOTOMETRIC TEST REPORT
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 1 LUMINAIRE PHOTOMETRIC TEST REPORT NAME: PANEL LIGHT 18w SPEC.: MFR.: Led spot s.a. de c.v. TYPE: DIM.: SUR.: WEIGHT: SERIAL No.: PROTECTION ANGLE:
LUMINAIRE PHOTOMETRIC TEST REPORT
Page 1 Of 11 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:12.1V I:.822A P:8.271W PF:.8382 Lamp Flux:622.45x1 lm NAME: RB4-9W-27K DATA OF LAMP PHOTOMETRIC DATA Eff: 75.26 lm/w MODEL RB4-9W-27K Imax(cd) 331.9
LUMINAIRE PHOTOMETRIC TEST REPORT
LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:22.V I:.22A P:1.W PF:.93 Lamp Flux:8368.6x1 lm DATA OF LAMP PHOTOMETRIC DATA Eff: 83.69 lm/w MODEL HB-1WA Imax(cd) 6177 S/MH(C/18) 1.8 NOMINAL POWER(W) 1 LOR(%)
LUMINAIRE PHOTOMETRIC TEST REPORT
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 12 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:12.1V I:.88A P:9.456W PF:.975 Lamp Flux:6.656x1 lm DATA OF LAMP PHOTOMETRIC DATA Eff: 63.52 lm/w MODEL
LUMINAIRE PHOTOMETRIC TEST REPORT
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 12 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:12.1V I:.1266A P:15.7W PF:.9911 Lamp Flux:1129.72x1 lm DATA OF LAMP PHOTOMETRIC DATA Eff: 74.96 lm/w MODEL
LUMINAIRE PHOTOMETRIC TEST REPORT
Luminous Intensity Test Report Page 1 Of 13 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:12.V I:.4124A P:49.W PF:.993 Lamp Flux:4244.53x1 lm NAME: 5W Flood light DATA OF LAMP PHOTOMETRIC DATA Eff: 86.62 lm/w
LUMINAIRE PHOTOMETRIC TEST REPORT
Luminous Intensity Test Report Page 1 Of 13 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:119.9V I:.1875A P:22.4W PF:.996 Lamp Flux:1634.99x1 lm DATA OF LAMP PHOTOMETRIC DATA Eff: 73. lm/w MODEL RSZ1714523-1
Shenzhen XXX OPTO Co.,Ltd
SYOPTICS TEST CENTER Page 1 Of 14 Shenzhen XXX OPTO Co.,Ltd LED spot light Light Output Ratio: 1.% Luminaire Power: 1.7 W SHR Nominal: Calculated using the TM5 SHR Maximum: 1. fine grid method. C Range:
LUMINAIRE PHOTOMETRIC TEST REPORT
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 1 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:23.V I:.5141A P:111.7W PF:.9444 Freq:59.98Hz Lamp Flux:14136.6x1 lm NAME: LED HIGH BAY (4W HID REPLACEMENT)
LUMINAIRE PHOTOMETRIC TEST REPORT
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 11 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:119.9V I:.6633A P:61.58W PF:.7741 Freq:6.1Hz Lamp Flux:6961.15x1 lm SUR.:1.16*.3*2 DATA OF LAMP PHOTOMETRIC
LUMINAIRE PHOTOMETRIC TEST REPORT
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 11 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:119.9V I:.683A P:72.3W PF:.9873 Freq:6.1Hz Lamp Flux:8499.2x1 lm NAME: 2X4 Panel 72W5K SUR.:1.17*.56 DATA
P10. Specifications. True Spectrum /60Hz UL Standard Output Voltage-Less than 48V DC. Illumination (3feet):
P1 Specifications Actual Wattage: Input Voltage: Input Current: Output Voltage: LED Source: Beam Angle: Illumination (3feet): Footprint: 15-17 Watts 85-265VAC.728 Amps@22V;.16 Amps@11V 5/6Hz UL Standard
LUMINAIRE PHOTOMETRIC TEST REPORT
LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:120.3V I:0.1610A P:18.70W PF:0.9670 Lamp Flux:2068.24x1 lm NAME: MC-BA-01-20D TYPE:LED DIM.: 600MM DATA OF LAMP PHOTOMETRIC DATA Eff: 110.60 lm/w MODEL MC-BA-01-20D
LUMINAIRE PHOTOMETRIC TEST REPORT
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 16 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:221.3V I:.1423A P:29.9W PF:.949 Lamp Flux:287.91x1 lm DATA OF LAMP PHOTOMETRIC DATA Eff: 95.89 lm/w MODEL
Final LUMINOUS INTENSITY DISTRIBUTION DIAGRAM
LUMINOUS INTENSITY DISTRIBUTION DIAGRAM -/+18 -/+18-15 15-15 15-12 12-12 12-9 9-9 9 4 4 8 8-6 12 6-6 12 6 16 UNIT:cd C /18 16 UNIT:cd C9 /27-3 2 3-3 2 3 AVERAGE BEAM ANGLE(5%):93.1 DEG AVERAGE BEAM ANGLE(5%):94.2
Final LUMINOUS INTENSITY DISTRIBUTION DIAGRAM
LUMINOUS INTENSITY DISTRIBUTION DIAGRAM -/+18 -/+18-15 15-15 15-12 12-12 12-9 9-9 9 1 1 2 2-6 3 6-6 3 6 4 UNIT:cd C /18 4 UNIT:cd C9 /27-3 5 3-3 5 3 AVERAGE BEAM ANGLE(5%):14.9 DEG AVERAGE BEAM ANGLE(5%):15.
Luminaire Photograph
Jiaxing Surefine Imp.&Exp. Co., Ltd Page 1 Of 13 Luminaire Photograph Light Output Ratio: 1.% Luminaire Power: 39.22 W SHR Nominal: 1.5 Calculated using the TM5 SHR Maximum: 1.55 fine grid method. C Range:
LUMINAIRE PHOTOMETRIC TEST REPORT
Page 1 Of 16 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:242.2V I:.828A P:193.1W PF:.962 Lamp Flux:221.3x1 lm NAME: TY-DFL1-2W-4K TYPE:V SERIAL No.:217312 DATA OF LAMP PHOTOMETRIC DATA Eff: 113.94 lm/w MODEL
LUMINAIRE PHOTOMETRIC TEST REPORT
LUMINAIRE PHOTOMETRIC TEST REPORT Report number: GO218-263 NAME: 11882 - KRONPLATZ PT1 TYPE:LUMINAIRE WEIGHT: DIMENSION: 43x21x25 SERIAL No.: DATA OF LAMP Imax(cd) 82.59 S/MH(C/18) 2.14 MODEL 11882 - KRONPLATZ
LUMINAIRE PHOTOMETRIC TEST REPORT
Page 1 Of 12 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:.2V I:.3512A P:41.83W PF:.9913 Lamp Flux:x2 lm DATA OF LAMP PHOTOMETRIC DATA Eff: 28.97 lm/w MODEL PHILIPS T5 F24W/83 Imax(cd) 248.4 S/MH(C/18) 1.29
Photometric Data of Luminaire
Photometric Data of Luminaire Lamp Test Data Lamp Flux: 5095.49 lm Center Cd.: 2020.7 cd Max(C,γ): (180,11.0) Maximum Cd.: 2105.9 cd BeamAngle(50%): 104.0 Deg BeamAngle(10%): 148.0 Deg Flux(0-90): 5094.36
Photometric Data of Luminaire
Photometric Data of Luminaire Lamp Test Data Lamp Flux: 14945.12 lm Center Cd.: 5459.5 cd Max(C,γ): (180,1.0) Maximum Cd.: 5500.2 cd BeamAngle(50%): 114.0 Deg BeamAngle(10%): 153.0 Deg Flux(0-90): 14941.48
LED FLOODLIGHT BLP FL12W04 NW CRI>80. V(B) Range:-80-80DEG V(B) Interval: 5.0DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V
Page 1 Of 9 LED FLOODLIGHT BLP FL12W4 NW CRI>8 Light Output Ratio: 1.% Luminaire Power: 13.2 W % Beam Spread 44.8V x 41.4H 5% Beam Lumens 763.5 lumens per klm. Page 2 Of 9 BLP FL12W4 NW CRI>8 Floodlight
LUMINAIRE PHOTOMETRIC TEST REPORT
LUMINAIRE PHOTOMETRIC TEST REPORT DATA OF LAMP PHOTOMETRIC DATA MODEL CYGNUS-LAMPA Imax(cd) OFFICE.2 S/MH(C/18) 1.21 NOMINAL POWER(W) 38.8 EFFICIENCY(%) 1. S/MH(C9/27) 1.19 RATED VOLTAGE(V) 23 TOTAL FLUX(lm)
LUMINAIRE PHOTOMETRIC TEST REPORT
LUMINAIRE PHOTOMETRIC TEST REPORT DATA OF LAMP PHOTOMETRIC DATA MODEL CANOPUS 24V~AC-LAMPA-DE Imax(cd) LUCRU.9 S/MH(C/18) 1.24 NOMINAL POWER(W) 5 EFFICIENCY(%) 76.9 S/MH(C/27) 1.23 RATED VOLTAGE(V) 24V~
STREETLIGHT PHOTOMETRIC TEST REPORT
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 8 STREETLIGHT PHOTOMETRIC TEST REPORT NAME: 5-5-TLS-ST-SS-35-NO SPEC.:spacing 12mm DATA OF LAMP PHOTOMETRIC DATA Eff: 12.79 lm/w MODEL5-5-TLS-ST-SS-35-NO
LED LUMINAIRE PHOTOMETRIC TEST REPORT
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 8 LED LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:22.1V I:.9421A P:21.2W PF:.978 Lamp Flux:17226lm NAME: 2W LED Flood Light TYPE:LED Flood Light WEIGHT:11.4Kg
LED Flood Light BLP FL16W01. V(B) Range:-80-80DEG V(B) Interval: 5.0DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V
Page 1 Of 9 LED Flood Light BLP FL16W1 Light Output Ratio: 1.% Luminaire Power: 18.1 W % Beam Spread 17.6V x 66.6H 5% Beam Lumens 716.4 lumens per klm. Page 2 Of 9 BLP FL16W1 Floodlight Summary: Report
LED Floodlight BLP FL72W01(4500K) V(B) Range: DEG V(B) Interval: 0.5DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V
Page 1 Of 9 LED Floodlight BLP FL72W1(45K) Light Output Ratio: 1.% Luminaire Power: 71.6 W % Beam Spread 51.7V x 39.4H 5% Beam Lumens 772.7 lumens per klm. Page 2 Of 9 BLP FL72W1(45K) Floodlight Summary:
LED Flood Light BLP FL48W01. V(B) Range:-80-80DEG V(B) Interval: 5.0DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V
Page 1 Of 9 LED Flood Light BLP FL48W1 Light Output Ratio: 1.% Luminaire Power: 52.4 W 9% Beam Spread 63.7V x 34.5H 5% Beam Lumens 762 lumens per klm. Page 2 Of 9 BLP FL48W1 Floodlight Summary: Report
LED Flood Light BLP FL36W01. V(B) Range:-80-80DEG V(B) Interval: 5.0DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V
Page 1 Of 9 LED Flood Light BLP FL36W1 Light Output Ratio: 1.% Luminaire Power: 38 W % Beam Spread 55.8V x 36.1H 5% Beam Lumens 698.1 lumens per klm. Page 2 Of 9 BLP FL36W1 Floodlight Summary: Report based
(METERS) FORWARD SOLAR ILLUMINATIONS SL02 (WMK) SOLAR HIGH-LUX STREET LIGHT
(METERS) FORWARD 1 2 3 4 5 6 7 8 9 1 5 Lux 6 Lux 8 Lux 11 Lux 15 Lux 2 Lux 25 Lux 29 Lux 29 Lux 25 Lux 2 Lux 15 Lux 11 Lux 8 Lux 6 Lux 5 Lux 35 Lux 38 Lux 39 Lux 34.5 Lux 27.5 Lux 2 Lux 14.5 Lux 1.5 Lux
Light Source Test Report
Spectrophotocolorimeter Test Report Page 1 of 1 Light Source Test Report 1. 1. = 213mW/nm 5.8 SDCM.5. 38.4. 5. 6. 7. 8. Wavelength(nm) x=.319 y=.347 61K/YANKON CIE Color Parameters: Chromaticity Coordinate:x=.3272
LED LUMINAIRE PHOTOMETRIC TEST REPORT
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 1 LED LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:22.2V I:.4865A P:13.7W PF:.9682 Lamp Flux:918lm NAME: 1W LED Flood Light TYPE:LED Flood Light WEIGHT:7.4Kg
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 9
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 9 Floodlight Summary: Report based on lamp delivering 1 lumens. Maximum Intensity (Luminaire orientation as tested.) 855.7 cd per klm.. degrees vertical.
Luminaire Property. Photometric Results. Page 1 of 15 Pages. Report No.: 9 Test Time: 2017/5/18 09:59
Report No.: 9 Test Time: 2017/5/18 09:59 Page 1 of 15 Pages Luminaire Property Luminaire Manufacturer: Luminaire Description: VMC4911 Current: 0.2A Power Factor: 0.989 Voltage: 120 V Power: 54.0W Photometric
Lisun Electronics Inc. Tel:+86(21)
Report No.: Test Time: 2014-01-20 17:40 Luminaire Property Page 1 of 25 Pages Luminaire Manufacturer: One Electrical Co.,Ltd Luminaire Category: OE-100WLEDFLOOD Lamp Description: 100W Floodlight Luminous
FACTORY DIRECT LIGHTING
Report No.: 20170711002 Test Time: 2017-07-13 15:11 Luminaire Property Luminaire Manufacturer: FACTORY DIRECT LIGHTING Luminaire Category: LED Luminaire Description: FDVT-40LED4K-120MD Lamp Catalog: 2835/ACT
Luminaire Property. Photometric Results. Tel: Page 1 of 39 Pages. Report No.: Test Time: :51
Report No.: Test Time: 2016-03-07 19:51 Page 1 of 39 Pages Luminaire Property Luminaire Manufacturer: Dauer Luminaire Description: LED-CGL-45CC-5000K Current: 0.359 A Power Factor: 0.992 Luminaire Part#:
Luminaire Property. Photometric Results. Page 1 of 35 Pages. Report No.: Test Time: :02
Report No.: Test Time: 2016-11-15 16:02 Luminaire Property Luminaire Manufacturer: Luminaire Description: AL110W48V50KDT3 Lamp Catalog: L130-5070-Q 档 Voltage: 346.8 V Current: 0.320 A Power: 110.00 W Power
Luminaire Property. Photometric Results. Page 1 of 35 Pages. Report No.: Test Time: :40
Report No.: Test Time: 2016-11-16 09:40 Luminaire Property Luminaire Manufacturer: Luminaire Description: AL105W27V50KDT3 Lamp Catalog: L130-5070-Q 档 Voltage: 120.2 V Current: 0.862 A Power: 103.40 W Power
Luminaire Property. Photometric Results. Page 1 of 35 Pages. Report No.: Test Time: :11. Luminaire Manufacturer: Power Factor: 0.
Report No.: Test Time: 2016-10-13 17:11 Page 1 of 35 Pages Luminaire Property Luminaire Manufacturer: Luminaire Category: MSPI-IS70A12S-1750 Lamp Catalog: L2C5-50701205E1300 Current: 0.593 A Power Factor:
Luminaire Property. Photometric Results. Page 1 of 35 Pages. Report No.: Test Time: :26. Luminaire Manufacturer: Power Factor: 0.
Report No.: Test Time: 2016-10-14 11:26 Page 1 of 35 Pages Luminaire Property Luminaire Manufacturer: Luminaire Category: MSPI-IS45A12S-1100 Lamp Catalog: 3030-5070-Q3DH Current: 0.370 A Power Factor:
SHENZHEN BESTWON TECHNOLOGY CO., LTD TEST REPORT SHENZHEN BESTWON TECHNOLOGY CO., LTD
Shenzhen BST Technology Co., Ltd. Report No.: BST1501403630003Y-1SR-2 SHENZHEN BESTWON TECHNOLOGY CO., LTD TEST REPORT Prepared For : SHENZHEN BESTWON TECHNOLOGY CO., LTD C Building, Huilongda Industrial
SHENZHEN BESTWON TECHNOLOGY CO., LTD TEST REPORT SHENZHEN BESTWON TECHNOLOGY CO., LTD
Shenzhen BST Technology Co., Ltd. Report No.: BST1501403630004Y-1SR-2 SHENZHEN BESTWON TECHNOLOGY CO., LTD TEST REPORT Prepared For : SHENZHEN BESTWON TECHNOLOGY CO., LTD C Building, Huilongda Industrial
TUBO LED T8 LLUMOR PROLED 25W 150CM
PHOTOMETRIC TEST REPORT Luminaire Property Luminaire: Report NO.: Test NO.: Lamp: LLUMOR-PL-T8-25W 6000K Sum Lumens: 3473.92 lm Number of Lamps: 1 Diameter: 0mm Length: 1500mm Photometric Type: Type C
LumCAT: BR-40W Luminaire: Report No: Voltage(V): Test No: Current(A): LampCAT: Power (W): Lamp flux(lm) PF: 1.
Yangzhou Bright Solar Solutions Co., Ltd. Anbotek Compliance Laboratory Ltd Http://www.anbotek.com.cn Email:vic.zhou@anbotek.com Tel:+86-755-26066365 Fax:+86-755-26014772 Address:1/F, Building 1, SEC Industrial
LumCAT: BR-45W Luminaire: Report No: Voltage(V): Test No: Current(A): LampCAT: Power (W): Lamp flux(lm) PF: 1.
Yangzhou Bright Solar Solutions Co., Ltd. Anbotek Compliance Laboratory Ltd Http://www.anbotek.com.cn Email:vic.zhou@anbotek.com Tel:+86-755-26066365 Fax:+86-755-26014772 Address:1/F, Building 1, SEC Industrial
LumCAT: BR0-20W Luminaire: Report No: Voltage(V): Test No: Current(A): LampCAT: Power (W): Lamp flux(lm) PF: 1.
Yangzhou Bright Solar Solutions Co., Ltd. Anbotek Compliance Laboratory Ltd Http://www.anbotek.com.cn Email:vic.zhou@anbotek.com Tel:+86-755-26066365 Fax:+86-755-26014772 Address:1/F, Building 1, SEC Industrial
TUBO LED T8 LLUMOR PROLED 18W 120CM
Luminaire Property Luminaire: Report NO.: Test NO.: Lamp: LLUMOR-PL-T8-18W 6000K Sum Lumens: 2483.33 lm Number of Lamps: 1 Diameter: 0mm Length: 1200mm Photometric Type: Type C Photometric Results Voltage:
TUBO LED T8 LLUMOR PROLED ULTRA 25W 150CM
PHOTOMETRIC TEST REPORT Luminaire Property Luminaire: Report NO.: Test NO.: Lamp: LLUMOR-PLU-25W-T8-6000K Sum Lumens: 4092.59 lm Number of Lamps: 1 Diameter: 0mm Length: 1512mm Photometric Type: Type C
Temperature: 25.5 CRH: 65% Spectrum Range: nm Scan Step: 5 nm. Spectral Distribution CIE1931 Chromaticity Diagram
Report of Spectroradiometric & Electric Analysis for Light Source ========================================================================= Model No.: LED-WP-40XXX Sample SN: S01 Test Report No.: BSR1502060101-9
Temperature: 25.5 CRH: 65% Spectrum Range: nm Scan Step: 5 nm. Spectral Distribution CIE1931 Chromaticity Diagram
Report of Spectroradiometric & Electric Analysis for Light Source ========================================================================= Model No.: LED-WP35-XXX Sample SN: S01 Test Report No.: BSR1501090101-10
Photometric Data of Lamp
SSP6316-D5: Lamp Intensity Spatial Distribution of Tester Page 1/8 Photometric Data of Lamp Lamp Name: GL-66P36WW Lamp Size: Lamp Weight: Light Area: 6cm 6cm Measured Data of Lamp Voltage: 225. V Current:.287
0-10V Dimmable QPLC# PXKSBVVP VAC 60HZ. 0.34A 120V; 0.20A 277V 40W PF ,303 LM 129 LM/W >83 H: 109 V: 136 <19.
0-10V Dimmable 71901 LED Linear Vaportight RoHS QPLC# PXKSBVVP Model: 71901 Input Voltage 120-277 VAC 60HZ Input Current 0.34A Max @ 120V; 0.20A Max @ 277V Input Power 40W Power Factor PF 0.98 OVERALL
0-10V Dimmable. RoHS VAC 60HZ. .34A 120V; 0.20A 277V 40W PF ,227 LM 130 LM/W >83 H: 108 V: 123 <19. Arcata VDC
71931 LED Decorative Linear Wrap 0-10V Dimmable RoHS QPL ID # PU971PAU Model: 71931 Input Voltage 120-277 VAC 60HZ Input Current.34A Max @ 120V; 0.20A Max @ 277V Input Power 40W Power Factor PF 0.98 OVERALL
SRLED-CPQ45-50K LED CANOPY/45W TECHNICAL DATA SHEET
FEATURES SRLED-CPQ45-50K LED CANOPY/45W TECHNICAL DATA SHEET Parking Garage Luminaires Ultra-thin design Replaces 120-175W MH HOUSING Sealed die-casting profile for indoor applications Polycarbonate optical
Compact Goniophotometer. Brochure
Compact Goniophotometer (LSG-1200A) Brochure Global Office of Lisun Electronics Inc. Lisun Group (Hong Kong) Limited Add: Room C, 15/F Hua Chiao Commercial Center, 678 Nathan Road, Mongkok, Kowloon, Hong
Photometric Test Report
Photometric Test Report Photometric and Optical Testing Services Cheltenham Film and Photographic Studios Hatherley Lane Cheltenham Gloucestershire GL51 6PN UK Tel: 01242 701300 Page 2 of 10 Photometric
Measurement Report. OxyTech Far East Ltd. Company:Highlite International BV. Sample Description:A Measurement Code:1006A/RV4129/08-13I-G5
Measurement Report Company:Highlite International BV Sample Description:A0340173 Measurement Code:1006A/RV4129/0813IG5 OxyTech Far East Ltd Table of Content Page 1. Measurement Data Sheet 0103 2. Polar
Measurement Report. OxyTech Far East Ltd. Company:Highlite International BV. Sample Description:A Measurement Code:1006A/RV4129/08-05I-G5
Measurement Report Company:Highlite International BV Sample Description:A01270 Measurement Code:1006A/RV129/08-05I-G5 OxyTech Far East Ltd Table of Content Page 1. Measurement Data Sheet 01-03 2. Polar
ΕΚΘΕΣΗ ΦΩΤΟΜΕΤΡΗΣΕΩΝ PHOTOMETRIC TEST REPORT. Αντικείμενο μετρήσεων: Αντιεκρηκτικός λαμπτήρας με LEDs / Item tested: Explosion proof lamp with LEDs
ΕΘΝΙΚΟ ΜΕΤΣΟΒΙΟ ΠΟΛΥΤΕΧΝΕΙΟ NATIONAL TECHNICAL UNIVERSITY OF ATHENS Σχολή Ηλεκτρολόγων Μηχανικών & Μηχανικών Υπολογιστών School of Electrical & Computer Engineering Εργαστήριο Φωτομετρίας / Laboratory
ΕΚΘΕΣΗ ΦΩΤΟΜΕΤΡΗΣΕΩΝ PHOTOMETRIC TEST REPORT. Αντικείμενο μετρήσεων: Σωληνωτός λαμπτήρας Τ8 με LEDs / Item tested: T8 fluorescent tube with LEDs
ΕΘΝΙΚΟ ΜΕΤΣΟΒΙΟ ΠΟΛΥΤΕΧΝΕΙΟ NATIONAL TECHNICAL UNIVERSITY OF ATHENS Σχολή Ηλεκτρολόγων Μηχανικών & Μηχανικών Υπολογιστών School of Electrical & Computer Engineering Εργαστήριο Φωτομετρίας / Laboratory
Artiste Picasso 9.1. Total Lumen Output: lm. Peak: cd 6862 K CRI: Lumen/Watt. Date: 4/27/2018
Color Temperature: 62 K Total Lumen Output: 21194 lm Light Quality: CRI:.7 Light Efficiency: 27 Lumen/Watt Peak: 1128539 cd Power: 793 W x: 0.308 y: 0.320 Test: Narrow Date: 4/27/2018 0 Beam Angle 165
ΕΚΘΕΣΗ ΦΩΤΟΜΕΤΡΗΣΕΩΝ PHOTOMETRIC TEST REPORT
ΕΘΝΙΚΟ ΜΕΤΣΟΒΙΟ ΠΟΛΥΤΕΧΝΕΙΟ NATIONAL TECHNICAL UNIVERSITY OF ATHENS Σχολή Ηλεκτρολόγων Μηχανικών & Μηχανικών Υπολογιστών School of Electrical & Computer Engineering Εργαστήριο Φωτοτεχνίας / Laboratory
ΕΚΘΕΣΗ ΦΩΤΟΜΕΤΡΗΣΕΩΝ PHOTOMETRIC TEST REPORT. Αντικείμενο μετρήσεων: Λαμπτήρας Ε40 με LEDs / Item tested: E40 lamp with LEDs
ΕΘΝΙΚΟ ΜΕΤΣΟΒΙΟ ΠΟΛΥΤΕΧΝΕΙΟ NATIONAL TECHNICAL UNIVERSITY OF ATHENS Σχολή Ηλεκτρολόγων Μηχανικών & Μηχανικών Υπολογιστών School of Electrical & Computer Engineering Εργαστήριο Φωτομετρίας / Laboratory
IES LM MEASUREMENT AND TEST REPORT For
IES LM-79-08 MEASUREMENT AND TEST REPORT For WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED Floor 8,B2 Building,YangGuangn Industrial Park, Bao An District,ShenZhen,China Test Model: WSD-2FLHB10W27-40K
ΕΚΘΕΣΗ ΦΩΤΟΜΕΤΡΗΣΕΩΝ PHOTOMETRIC TEST REPORT
ΕΘΝΙΚΟ ΜΕΤΣΟΒΙΟ ΠΟΛΥΤΕΧΝΕΙΟ NATIONAL TECHNICAL UNIVERSITY OF ATHENS Σχολή Ηλεκτρολόγων Μηχανικών & Μηχανικών Υπολογιστών School of Electrical & Computer Engineering Εργαστήριο Φωτοτεχνίας / Laboratory
DULUX L LUMILUX IMPROVED LIFETIME & SYSTEM GUARANTEE. DULUX L LUMILUX & QUICKTRONIC TECHNICAL INFORMATION
www.osram.com IMPROVED LIFETIME & SYSTEM GUARANTEE QTP-M 1x26-42 1 Benefits Extremly economical Good quality of light Excellent luminous flux Improved lumen maintenance Long service life time OSRAM + Guarantee
CLL042 series LM-80 Report
Page:1/18 CLL042 series LM-80 Report LM-80 Report No. LM1201001 Original Copy Customer Name:CITIZEN ELECTRONICS CO.,LTD. 1. Number of LED sources 20 randomly selected samples for each Tc Test report must
CLL050 series LM-80 Report
Page:1/10 CLL050 series LM-80 Report LM-80 Report No. LM1103501 Original Copy Customer Name:CITIZEN ELECTRONICS CO.,LTD. # 69510 1. Number of LED sources 20 randomly selected samples for each Tc Test report
Daewoo Technopark A-403, Dodang-dong, Wonmi-gu, Bucheon-city, Gyeonggido, Korea LM-80 Test Report
LM-80 Test Report Approved Method: Measuring Lumen Maintenance of LED Light Sources Project Number: KILT1212-U00216 Date: September 17 th, 2013 Requested by: Dongbu LED Co., Ltd 90-1, Bongmyeong-Ri, Namsa-Myeon,
QUICKTRONIC PROFESSIONAL QTP5
osram.com QUICKTRONIC PROFESSIONA QTP5 ECG for T5/ 16mm, T8/ 26mm, DUUX fluorescent lamps QTP5 i.e. UMIUX T5 HO ES 01 Product Features: Up to 100.000 hours lifetime 1 amp start with optimized filament
Quartz Crystal Test Report
Quartz Crystal Test Report Abracon Part no. : Data Type: Page 2-3 Page 4-5 Page 6-7 Page 8-9 Page 10-11 ABM8-Series Crystal parameters & Spice Model ABM8-16.000MHz-10-1-U ABM8-13.000MHz-10-1-U ABM8-40.000MHz-10-1-U
Φωτοµετρικά µεγέθη πολική κατανοµή φωτοβολίας
Ο8 ωτοµετρικά µεγέθη πολική κατανοµή φωτοβολίας 1. Σκοπός Σκοπός της άσκησης είναι αφ ενός η κατανόηση βασικών µεγεθών και νόµων της φωτοµετρίας και αφ ετέρου η µέτρηση της πολικής κατανοµής της φωτοβολίας
C4C-C4H-C4G-C4M MKP Series AXIAL CAPACITORS PCB APPLICATIONS
C4C-C4H-C4G-C4M AXIAL CAPACITORS PCB APPLICATIONS General characteristics - Self-Healing - Low losses - High ripple current - High contact reliability - Suitable for high frequency applications 40 ±5 L
1 / Report Number: AELAB Report No. Sample Name. Type PC COOL. Test
Report Number: AELAB20160115-003 1 / Test Re porr t Report No. Sample Name Type Customer Test Purpose AELAB20160115-003 50W Floodlight FL-RBPCB101X070-104LED50W-RevA PC COOL Product Specification Verification
Metal Oxide Varistors (MOV) Data Sheet
Φ SERIES Metal Oxide Varistors (MOV) Data Sheet Features Wide operating voltage (V ma ) range from 8V to 0V Fast responding to transient over-voltage Large absorbing transient energy capability Low clamping
ΥΠΟΛΟΓΙΣΜΟΙ. Α. Τσαγκρασούλης Τμ. Αρχιτεκτόνων Μηχανικών, Πανεπιστήμιο Θεσσαλίας
ΥΠΟΛΟΓΙΣΜΟΙ Α. Τσαγκρασούλης Τμ. Αρχιτεκτόνων Μηχανικών, Πανεπιστήμιο Θεσσαλίας LUMEN METHOD (ή ZONAL CAVITY METHOD) Με τη συγκεκριμένη μεθοδολογία εκτιμάται η φωτεινή ροή που εκπέμπεται απο τα φωτιστικά