EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 12 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:23.4V I:.835A P:18.32W PF:.952 Lamp Flux:2845.34x1 lm DATA OF LAMP PHOTOMETRIC DATA Eff: 155.34 lm/w MODEL Imax(cd) 687.2 S/MH(C/18) 1.38 NOMINAL POWER(W) LOR(%) 1. S/MH(C9/27) 1.21 RATED VOLTAGE(V) 23 TOTAL FLUX(lm) 2845.3 h UP,DN(C-18) 8.5,41.1 NOMINAL FLUX(lm) 2845.34 CIE CLASS SEMI-D. h UP,DN(C18-36) 8.6,41.8 LAMPS INSIDE 1 h up(%) 17.1 CIBSE SHR NOM 1.5 TEST VOLTAGE(V) 23 h down(%) 82.9 CIBSE SHR MAX 1.5 LUMINOUS INTENSITY DISTRIBUTION DIAGRAM C PLANE ISOLUX DIAGRAM (UNIT:lx) MH(m) 1 14-15 -/+18 15 18 22-12 12 26 3-9 9 34 14 28-6 42 6 56 UNIT:cd C/18,146.8deg C3/21,136.8deg -3 7 3 C6/24,114.2deg C9/27,13.4deg AVERAGE BEAM ANGLE(5%):125.3 DEG 38 42 46 5. 16.5 33. 4.1 3.4 2.7 2.1 1.4.69.55.34.27.21 S(m) C Range: - 36DEG C Interval: 3.DEG Test Date:217-1-28 g Range: - 18DEG g Interval: 1.DEG Test System:EVERFINE GO-2A_V1 SYSTEM V2..293 Humidity:65.% Test Distance:7.37m [K=1.]
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 2 Of 12 ZONAL FLUX DIAGRAM ZONAL FLUX DIAGRAM: g C C45 C9 C135 C18 C225 C27 C315 zone total %lum,lamp g F F 1 67.5 669.6 67.2 678. 684.5 678.2 669.8 669.2-1 64.88 64.88 2.28,2.28 2 639.7 631. 624.7 648.2 667.4 648.4 624.2 63.8 1-2 186.1 251. 8.82,8.82 3 595.1 573.6 553.7 597.6 634.2 598.1 552.9 572.8 2-3 283.2 534.2 18.8,18.8 4 54.8 52.9 463. 531.3 587.4 531.9 462.4 52. 3-4 345.5 879.7 3.9,3.9 5 479.4 425.3 361.1 454.7 528.9 455.3 36.6 423.9 4-5 368.6 1248 43.9,43.9 6 413.5 346.5 254.6 373.8 461.3 374.9 254.3 345.1 5-6 354.9 163 56.3,56.3 7 347.4 272.6 149.9 295.2 388.6 296.4 15. 27.7 6-7 312.1 1915 67.3,67.3 8 285.7 28.2 56.68 225.3 317.1 226.7 56.49 26. 7-8 252.3 2168 76.2,76.2 9 231.5 157.2 4.151 169.2 254.2 17.5 4.11 155. 8-9 19.8 2358 82.9,82.9 1 186.4 119.8 5.115 128.4 22.6 129.7 4.918 117.9 9-1 144. 252 88,88 11 149.3 93.37 6.299 99.95 161.4 11.1 6.274 91.4 1-11 19. 2611 91.8,91.8 12 118.8 73.17 7.572 8.3 128.6 8.87 7.39 71.15 11-12 81.12 2693 94.6,94.6 13 94.3 57.91 8.838 65.58 11.8 66.12 8.625 55.25 12-13 58.7 2751 96.7,96.7 14 73.42 43.65 1.7 54.91 79.66 55.16 9.856 41.98 13-14 4.94 2792 98.1,98.1 15 57.14 34.12 11.2 46.71 61.86 46.91 11.4 32.83 14-15 26.84 2819 99.1,99.1 16 45.5 27.58 12.17 37.78 45.63 37.57 12.9 26.84 15-16 16.26 2835 99.6,99.6 17 28.37 23.2 12.93 27.85 27.22 27.93 12.89 22.94 16-17 8.21 2843 99.9,99.9 18 13.94 13.36 13.29 13.33 13.91 13.36 13.29 13.33 17-18 1.988 2845 1,1 DEG LUMINOUS INTENSITY:cd UNIT:lm C Range: - 36DEG C Interval: 3.DEG Test Date:217-1-28 g Range: - 18DEG g Interval: 1.DEG Test System:EVERFINE GO-2A_V1 SYSTEM V2..293 Humidity:65.% Test Distance:7.37m [K=1.]
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 3 Of 12 CU AND LUMINAIRE BUDGETARY ESTIMATE DIAGRAM Test:U:23.4V I:.835A P:18.32W PF:.952 Lamp Flux:2845.34x1 lm rcc rw rfc RCR 8% 7% 5% 3% 5% 3% 1% 5% 3% 1% 5% 3% 1% 5% 3% 1% 2% 2% 2% 2% RCR:Room Cavity Ratio Coefficients of Utilization(CU) 1% 5% 3% 1% 2%. 1. 1.15.97 1.15.91 1.15.87 1.1.93 1.1.88 1.1.84 1.2.85 1.2.81 1.2.78.94.78.94.75.94.72.86.72.86.7.86.67.83.64 2. 3..83.72.75.63.69.56.79.69.73.61.67.55.73.64.67.57.62.51.67.59.63.53.58.48.62.54.58.49.55.45.51.42 4. 5..63.56.54.47.47.4.61.54.52.46.46.39.56.5.49.43.43.37.52.46.46.4.41.35.48.43.43.37.39.33.36.31 6. 7. 8..51.46.42.41.37.33.35.3.27.49.44.4.4.36.32.34.3.26.45.41.37.38.34.3.32.28.25.42.38.35.35.32.29.31.27.24.39.35.32.33.3.27.29.26.23.27.23.21 9. 1..38.35.3.27.24.22.37.34.29.26.24.21.34.32.27.25.23.2.32.3.26.24.22.2.3.28.25.22.21.19.19.17 LAMPS 5 LUMINAIRE BUDGETARY DIAGRAM 4 3 2 H=8 1 9 8 7 6 5 4 3 4 5 H=5 6 7 CONDITIONS 3 2 2 1 2 3 4 5 7 1 2 3 5 7 1k 2k 3k 4k 5k 7k AREA(m2) FLUX 2lm FACTOR.7 Hdown.m Hwork.5m Ework(AVE) 1lx r (%) cc w fc 7 5 3 5 3 2 C Range: - 36DEG C Interval: 3.DEG Test Date:217-1-28 g Range: - 18DEG g Interval: 1.DEG Test System:EVERFINE GO-2A_V1 SYSTEM V2..293 Humidity:65.% Test Distance:7.37m [K=1.]
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 4 Of 12 WEC AND CCEC Test:U:23.4V I:.835A P:18.32W PF:.952 Lamp Flux:2845.34x1 lm rcc 8% 7% 5% 3% 1% rw 5% 3% 1% 5% 3% 1% 5% 3% 1% 5% 3% 1% 5% 3% 1% rfc 2% 2% 2% 2% 2% RCR RCR:Room Cavity Ratio Wall Exitance Coeffcients(WEC). 1..372.212.67.36.25.65.336.193.62.315.182.58.295.171.55 2..325.178.55.314.173.53.293.163.51.273.153.48.255.144.46 3..29.154.46.28.15.45.261.141.43.243.133.41.227.126.39 4..262.136.4.253.132.39.236.125.37.22.118.36.25.111.34 5..239.122.35.23.118.34.215.112.33.2.16.31.187.1.3 6..219.11.31.212.17.31.197.11.29.184.96.28.172.9.27 7..22.1.28.196.97.28.183.92.27.17.87.25.159.83.24 8..188.92.26.182.89.25.17.85.24.159.8.23.148.76.22 9..175.85.24.17.83.23.159.78.22.148.74.21.139.7.2 1..164.79.22.159.77.21.149.73.21.139.69.2.13.65.19 rcc rw rfc RCR. 1. 2. 3. 4. 5. 6. 7. 8. 9. 1. 8% 7% 5% 3% 1% 5% 3% 1% 5% 3% 1% 5% 3% 1% 5% 3% 1% 5% 3% 1% 2% 2% 2% 2% 2% RCR:Room Cavity Ratio Ceiling Cavity Exitance Coefficients(CCEC).321.316.39.31.294.286.279.272.265.259.253.321.287.264.247.235.225.217.21.25.2.196.321.261.226.25.19.18.173.168.164.16.158.274.27.265.258.252.246.239.234.228.223.218.274.246.227.213.23.195.188.182.178.174.17.274.225.196.177.165.157.151.146.143.14.138.187.185.181.177.173.169.165.161.158.154.151.187.169.157.148.141.136.132.128.125.122.12.187.155.136.124.116.111.17.13.11.99.98.18.16.15.12.1.98.96.94.92.9.88.18.98.91.87.83.8.77.75.74.72.71.18.9.8.73.69.66.63.62.6.59.58.34.34.34.33.32.32.31.3.3.29.29.34.32.3.28.27.26.25.25.24.24.23.34.29.26.24.23.22.21.2.2.2.19 C Range: - 36DEG C Interval: 3.DEG Test Date:217-1-28 g Range: - 18DEG g Interval: 1.DEG Test System:EVERFINE GO-2A_V1 SYSTEM V2..293 Humidity:65.% Test Distance:7.37m [K=1.]
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 5 Of 12 UGR(Unified Glare Rating) Table Test:U:23.4V I:.835A P:18.32W PF:.952 Lamp Flux:2845.34x1 lm ceiling/cavity.7.7.5.5.3.7.7.5.5.3 walls.5.3.5.3.3.5.3.5.3.3 working plane.2.2.2.2.2.2.2.2.2.2 Room dimensions Viewed crosswise Viewed endwise x = 2H y = 2H 3H 4H 6H 8H 12H 22.3 23.7 22.8 24.1 24.7 2.4 21.8 2.9 22.3 22.8 24.8 26. 25.3 26.5 27.1 21.9 23.1 22.4 23.7 24.2 26.1 27.3 26.7 27.9 28.5 22.4 23.6 23. 24.2 24.8 27.6 28.8 28.2 29.3 29.9 22.8 24. 23.4 24.5 25.2 28.5 29.6 29. 3.1 3.8 23. 24. 23.5 24.6 25.3 29.4 3.5 3. 31.1 31.7 23. 24.1 23.6 24.6 25.3 4H 2H 3H 4H 6H 8H 12H 22.8 24. 23.4 24.6 25.2 21.5 22.7 22. 23.2 23.8 25.6 26.6 26.1 27.2 27.8 23.2 24.2 23.8 24.8 25.5 27.1 28.1 27.7 28.7 29.4 24. 24.9 24.6 25.5 26.2 28.8 29.7 29.5 3.3 31.1 24.6 25.4 25.2 26.1 26.8 29.8 3.6 3.5 31.2 32. 24.8 25.6 25.5 26.3 27. 3.9 31.7 31.6 32.3 33.1 25. 25.7 25.6 26.4 27.1 8H 4H 6H 8H 12H 27.5 28.3 28.1 28.9 29.6 24.9 25.7 25.6 26.4 27.1 29.5 3.2 3.2 3.8 31.6 25.9 26.6 26.6 27.3 28.1 3.7 31.3 31.4 32. 32.8 26.4 27. 27.1 27.7 28.5 32. 32.6 32.7 33.3 34.1 26.8 27.3 27.5 28. 28.8 12H 4H 6H 8H 27.5 29.6 3.9 28.2 3.2 31.4 28.1 3.3 31.6 28.9 3.9 32.1 29.6 31.7 33. 25.2 26.5 27.1 26. 27.1 27.6 25.9 27.2 27.8 26.6 27.8 28.3 27.4 28.6 29.2 Variations with the observer position at spacings: S = 1.H +.1 / -.1 +.1 / -.2 1.5H +.2 / -.3 +.2 / -.3 2.H +.2 / -.3 +.2 / -.4 CIE Pub.117 Corrected 2845 lm Total Lamp Luminous Flux.(8log(F/F) = 3.6) C Range: - 36DEG C Interval: 3.DEG Test Date:217-1-28 g Range: - 18DEG g Interval: 1.DEG Test System:EVERFINE GO-2A_V1 SYSTEM V2..293 Humidity:65.% Test Distance:7.37m [K=1.]
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 6 Of 12 UTILIZATION FACTORS TABLE Test:U:23.4V I:.835A P:18.32W PF:.952 Lamp Flux:2845.34x1 lm REFLECTANCE Ceiling.8.8.8.7.7.7.5.5.5 Walls.7.5.3.7.5.3.7.5.3 Working plane.2.2.2.2.2.2.2.2.2 ROOM INDEX UTILIZATION FACTORS(PERCENT) k(ri) x RCR = 5 k =.6 49 37 3 48 36 29 46 36 29 22.8 58 46 38 57 45 37 54 43 36 29 1. 66 53 45 64 52 45 61 53 44 35 1.25 73 61 52 71 59 52 66 57 5 4 1.5 78 66 58 75 65 57 71 62 55 45 2. 85 75 67 82 72 65 77 69 62 51 2.5 9 8 72 86 77 7 8 73 67 55 3. 93 84 77 9 82 75 83 77 71 58 4. 98 9 84 94 87 81 87 81 77 63 5. 11 94 88 97 91 86 89 85 8 66 ROOM INDEX UF(total) Direct According to DIN EN 1332-2 24 Suspended SHRNOM = 1.25 C Range: - 36DEG C Interval: 3.DEG Test Date:217-1-28 g Range: - 18DEG g Interval: 1.DEG Test System:EVERFINE GO-2A_V1 SYSTEM V2..293 Humidity:65.% Test Distance:7.37m [K=1.]
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 7 Of 12 ISOCANDELA DIAGRAM Test:U:23.4V I:.835A P:18.32W PF:.952 Lamp Flux:2845.34x1 lm Conical surface Flux(9deg): 163.6 lm %lum = 37.4% 9 %lamp = 37.4% 8 Conical surface Flux(12deg): 7 163.3 lm %lum = 56.3% 6 %lamp = 56.3% 5 VERTICAL(DEG) 4 3 2 1-1 -2-3 -4-5 -6 1% 68.72 15% 13.1 2% 137.4 25% 171.8 3% 26.2 35% 24.5 4% 274.9 45% 39.3 5% 343.6 55% 378. 6% 412.3 65% 446.7 7% 481.1 75% 515.4 8% 549.8 85% 584.2 9% 618.5 95% 652.9-7 -8-9 -9-8 -7-6 -5-4 -3-2 -1 1 2 3 4 5 6 7 8 9 Imax:687.2(H-5.,V.) (At:C=18.,Gamma=5.) UNIT: cd HORIZONTAL(DEG) C Range: - 36DEG C Interval: 3.DEG Test Date:217-1-28 g Range: - 18DEG g Interval: 1.DEG Test System:EVERFINE GO-2A_V1 SYSTEM V2..293 Humidity:65.% Test Distance:7.37m [K=1.]
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 8 Of 12 AAI Figure Test:U:23.4V I:.835A P:18.32W PF:.952 Lamp Flux:2845.34x1 lm Flux out:172 lm 1m 14.7,.lx 386.66cm 2m 35.17,171.5lx 773.33cm 3m 15.63,76.22lx 1159.99cm 4m 8.793,42.88lx 1546.66cm 5m 5.627,27.44lx 1933.32cm Height Eavg,Emax Angle:125.3deg Diameter Note:The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance. C Range: - 36DEG C Interval: 3.DEG Test Date:217-1-28 g Range: - 18DEG g Interval: 1.DEG Test System:EVERFINE GO-2A_V1 SYSTEM V2..293 Humidity:65.% Test Distance:7.37m [K=1.]
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 9 Of 12 ISOLUX DIAGRAM Test:U:23.4V I:.835A P:18.32W PF:.952 Lamp Flux:2845.34x1 lm 65.8' 32.9'.' 32.9' 65.8' 82.2' 25.6m 65.8' 2.5m 49.3' 15.4m 32.9' 1.3m 3%.257lx.1911fc 5%.3428lx.3185fc 1%.6857lx.637fc 3% 2.57lx.1911fc 5% 3.428lx.3185fc 6% 4.114lx.3822fc 16.4' 5.1m.'.m 16.4' 5.1m 32.9' 1.3m 49.3' 15.4m 65.8' 2.5m 82.2' 25.6m 2.5m 1.3m.m 1.3m 2.5m MOUNTING HEIGHT: 33'(1.m) C Range: - 36DEG C Interval: 3.DEG Test Date:217-1-28 g Range: - 18DEG g Interval: 1.DEG Test System:EVERFINE GO-2A_V1 SYSTEM V2..293 Humidity:65.% Test Distance:7.37m [K=1.]
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 12 LED Avg.L Report Test:U:23.4V I:.835A P:18.32W PF:.952 Lamp Flux:2845.34x1 lm AvgL cd/m2 L_~18(65)av 23823 L_~18(75)av 32253 L_~18(85)av 7775 L_9~27(65)av 1193 L_9~27(75)av 9751 L_9~27(85)av 6132 L_45(65)av 19132 L_45(75)av 24392 L_45(85)av 5537 Standard: GB/T 29293-212 C Range: - 36DEG C Interval: 3.DEG Test Date:217-1-28 g Range: - 18DEG g Interval: 1.DEG Test System:EVERFINE GO-2A_V1 SYSTEM V2..293 Humidity:65.% Test Distance:7.37m [K=1.]
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 11 Of 12 Planar Illuminance Curve E(lx) 7 6.3 Planar Illuminance Curve MH = 1 m C/18 C9/27 5.6 4.9 4.2 3.5 2.8 2.1 1.4.7-25 -2-15 -1-5 5 1 15 2 25 Distance(m) C Range: - 36DEG C Interval: 3.DEG Test Date:217-1-28 g Range: - 18DEG g Interval: 1.DEG Test System:EVERFINE GO-2A_V1 SYSTEM V2..293 Humidity:65.% Test Distance:7.37m [K=1.]
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 12 Of 12 LUMINOUS DISTRIBUTION INTENSITY DATA Test:U:23.4V I:.835A P:18.32W PF:.952 Lamp Flux:2845.34x1 lm g Table--1 C(DEG) (DEG) 5 68 1 67 15 657 2 64 25 619 3 595 35 569 4 541 45 511 5 479 55 447 6 413 65 38 7 347 75 316 8 286 85 257 9 232 95 28 1 186 15 167 11 149 115 133 12 119 125 16 13 94. 135 83.4 14 73.4 145 64.8 15 57.1 155 5.5 16 45.1 165 4.2 17 28.4 175 18.8 18 13.9 3 68 67 655 636 612 585 556 524 49 455 42 385 35 317 285 255 228 23 181 16 142 126 112 1. 46.4 86.8 78.2 66.8 55.8 47.1 4.3 35. 3.6 25.5 23.3 21.6 13.4 6 68 669 65 626 596 562 524 482 439 395 351 38 267 228 193 161 134 111 93.5 79.4 68.4 6.3 53.2 41.3 37.6 34.2 31.5 29.5 27.9 25.9 24.6 24. 23.1 2.3 13.3 9 682 67 651 625 592 554 51 463 413 361 38 255 22 15 11 56.7 21.5 4.15 4.56 5.11 5.67 6.3 6.94 7.57 8.21 8.84 9.46 1.1 1.7 11.2 11.7 12.2 12.6 12.9 13.2 13.3 12 684 675 66 638 611 578 542 52 459 415 37 325 282 242 24 171 142 118 99.1 84.3 72.8 64.2 57.7 52.6 48.8 45.9 43.6 41.8 4.3 38.6 35.8 3.7 27.9 25.2 2.6 13.3 15 681 672 658 64 617 591 561 529 495 459 422 385 349 313 28 248 22 195 172 153 136 121 17 95.7 85.3 76.2 68.1 61. 54.8 49.5 44.9 39.1 3.5 24.8 13.4 18 687 684 678 667 653 634 612 587 56 529 496 461 425 389 352 317 284 254 227 23 181 161 144 129 115 12 9.1 79.7 7.3 61.9 54.5 45.6 4.9 27.2 17.9 13.9 21 681 672 658 64 617 59 561 529 495 459 422 385 349 313 28 249 221 195 173 154 136 121 18 96.3 85.8 76.4 68.3 61.1 54.9 49.5 44.8 38.8 3.4 23.3 13.4 24 684 675 66 639 611 579 543 53 46 416 372 328 285 244 27 174 145 121 11 86.2 74.6 65.7 58.9 53.7 49.6 46.5 44. 42.1 4.5 38.9 36. 3.3 28.3 25.5 21. 13.3 27 682 67 65 624 591 553 51 462 412 361 38 254 22 15 11 56.5 21.3 4.1 4.29 4.92 5.69 6.27 6.8 7.39 8. 8.63 9.24 9.86 1.5 11. 11.6 12.1 12.5 12.9 13.2 13.3 3 68 669 65 626 596 561 523 482 438 394 35 37 265 226 19 158 131 19 9.9 77.1 66.5 57.6 5.5 45. 4.2 36.6 33.2 3.7 28.8 27.1 25.4 24.1 23.7 22.9 2.4 13.3 33 68 67 655 635 612 584 554 522 488 454 418 383 349 315 283 254 226 21 179 159 141 125 111 97.4 85.3 73.9 65.3 53.3 45.1 38.5 33.6 29.6 25. 22.9 21.6 13.4 UNIT: cd C Range: - 36DEG C Interval: 3.DEG Test Date:217-1-28 g Range: - 18DEG g Interval: 1.DEG Test System:EVERFINE GO-2A_V1 SYSTEM V2..293 Humidity:65.% Test Distance:7.37m [K=1.]