LumCAT: BR0-20W Luminaire: Report No: Voltage(V): Test No: Current(A): LampCAT: Power (W): Lamp flux(lm) PF: 1.

Σχετικά έγγραφα
LumCAT: BR-40W Luminaire: Report No: Voltage(V): Test No: Current(A): LampCAT: Power (W): Lamp flux(lm) PF: 1.

LumCAT: BR-45W Luminaire: Report No: Voltage(V): Test No: Current(A): LampCAT: Power (W): Lamp flux(lm) PF: 1.

SHENZHEN BESTWON TECHNOLOGY CO., LTD TEST REPORT SHENZHEN BESTWON TECHNOLOGY CO., LTD

SHENZHEN BESTWON TECHNOLOGY CO., LTD TEST REPORT SHENZHEN BESTWON TECHNOLOGY CO., LTD

Temperature: 25.5 CRH: 65% Spectrum Range: nm Scan Step: 5 nm. Spectral Distribution CIE1931 Chromaticity Diagram

Temperature: 25.5 CRH: 65% Spectrum Range: nm Scan Step: 5 nm. Spectral Distribution CIE1931 Chromaticity Diagram

TUBO LED T8 LLUMOR PROLED ULTRA 25W 150CM

TUBO LED T8 LLUMOR PROLED 25W 150CM

TUBO LED T8 LLUMOR PROLED 18W 120CM

LUMINAIRE PHOTOMETRIC TEST REPORT

(METERS) FORWARD SOLAR ILLUMINATIONS SL02 (WMK) SOLAR HIGH-LUX STREET LIGHT

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

STREETLIGHT PHOTOMETRIC TEST REPORT

Shenzhen XXX OPTO Co.,Ltd

LED LUMINAIRE PHOTOMETRIC TEST REPORT

SHENZHEN BRILLOOP LIGHTING CO.,LTD Page 1 Of 13. LED Floodlight 24W(COB)

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 12 LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

LED LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

Final LUMINOUS INTENSITY DISTRIBUTION DIAGRAM

Final LUMINOUS INTENSITY DISTRIBUTION DIAGRAM

P10. Specifications. True Spectrum /60Hz UL Standard Output Voltage-Less than 48V DC. Illumination (3feet):

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 13 ROYAL PACIFIC LTD. LUMINAIRE PHOTOMETRIC TEST REPORT TYPE:LED DIM.: SUR.

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 14 LED LUMINAIRE PHOTOMETRIC TEST REPORT

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 14 LED LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

Luminaire Photograph

Photometric Data of Luminaire

Photometric Data of Luminaire

Lisun Electronics Inc. Tel:+86(21)

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT

LED Flood Light BLP FL48W01. V(B) Range:-80-80DEG V(B) Interval: 5.0DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V

LED Flood Light BLP FL16W01. V(B) Range:-80-80DEG V(B) Interval: 5.0DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V

LED Flood Light BLP FL36W01. V(B) Range:-80-80DEG V(B) Interval: 5.0DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V

LED Floodlight BLP FL72W01(4500K) V(B) Range: DEG V(B) Interval: 0.5DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V

LED FLOODLIGHT BLP FL12W04 NW CRI>80. V(B) Range:-80-80DEG V(B) Interval: 5.0DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V

Luminaire Property. Photometric Results. Page 1 of 15 Pages. Report No.: 9 Test Time: 2017/5/18 09:59

FACTORY DIRECT LIGHTING

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 9

Luminaire Property. Photometric Results. Tel: Page 1 of 39 Pages. Report No.: Test Time: :51

Light Source Test Report

Luminaire Property. Photometric Results. Page 1 of 35 Pages. Report No.: Test Time: :02

Luminaire Property. Photometric Results. Page 1 of 35 Pages. Report No.: Test Time: :40

Photometric Data of Lamp

Luminaire Property. Photometric Results. Page 1 of 35 Pages. Report No.: Test Time: :11. Luminaire Manufacturer: Power Factor: 0.

Luminaire Property. Photometric Results. Page 1 of 35 Pages. Report No.: Test Time: :26. Luminaire Manufacturer: Power Factor: 0.

Compact Goniophotometer. Brochure

0-10V Dimmable. RoHS VAC 60HZ. .34A 120V; 0.20A 277V 40W PF ,227 LM 130 LM/W >83 H: 108 V: 123 <19. Arcata VDC

SRLED-CPQ45-50K LED CANOPY/45W TECHNICAL DATA SHEET

0-10V Dimmable QPLC# PXKSBVVP VAC 60HZ. 0.34A 120V; 0.20A 277V 40W PF ,303 LM 129 LM/W >83 H: 109 V: 136 <19.

Photometric Test Report

ΕΚΘΕΣΗ ΦΩΤΟΜΕΤΡΗΣΕΩΝ PHOTOMETRIC TEST REPORT. Αντικείμενο μετρήσεων: Λαμπτήρας Ε40 με LEDs / Item tested: E40 lamp with LEDs

Measurement Report. OxyTech Far East Ltd. Company:Highlite International BV. Sample Description:A Measurement Code:1006A/RV4129/08-13I-G5

ΕΚΘΕΣΗ ΦΩΤΟΜΕΤΡΗΣΕΩΝ PHOTOMETRIC TEST REPORT. Αντικείμενο μετρήσεων: Σωληνωτός λαμπτήρας Τ8 με LEDs / Item tested: T8 fluorescent tube with LEDs

ΕΚΘΕΣΗ ΦΩΤΟΜΕΤΡΗΣΕΩΝ PHOTOMETRIC TEST REPORT. Αντικείμενο μετρήσεων: Αντιεκρηκτικός λαμπτήρας με LEDs / Item tested: Explosion proof lamp with LEDs

Measurement Report. OxyTech Far East Ltd. Company:Highlite International BV. Sample Description:A Measurement Code:1006A/RV4129/08-05I-G5

Artiste Picasso 9.1. Total Lumen Output: lm. Peak: cd 6862 K CRI: Lumen/Watt. Date: 4/27/2018

ΕΚΘΕΣΗ ΦΩΤΟΜΕΤΡΗΣΕΩΝ PHOTOMETRIC TEST REPORT

SAMSUNG ELECTRONICS CO., LTD TEST REPORT SAMSUNG ELECTRONICS CO., LTD. 1, Samsung-Ro, Giheung-Gu, Yongin-Si, Gyeonggi-Do 17113, Korea

ΕΚΘΕΣΗ ΦΩΤΟΜΕΤΡΗΣΕΩΝ PHOTOMETRIC TEST REPORT

Φωτοµετρικά µεγέθη πολική κατανοµή φωτοβολίας

IES LM MEASUREMENT AND TEST REPORT For

CLL050 series LM-80 Report

Quartz Crystal Test Report

DULUX L LUMILUX IMPROVED LIFETIME & SYSTEM GUARANTEE. DULUX L LUMILUX & QUICKTRONIC TECHNICAL INFORMATION

CLL042 series LM-80 Report

Daewoo Technopark A-403, Dodang-dong, Wonmi-gu, Bucheon-city, Gyeonggido, Korea LM-80 Test Report

ΗΛΕΚΤΡΟΝΙΚΟΣ ΚΑΤΑΛΟΓΟΣ ΠΡΟΙΟΝΤΩΝ 2014

*Το σημείωμα βασίζεται και σε στοιχεία από προγενέστερη έρευνα για την αγορά γούνας από την κα. Γεωργία Βελέντζα, Γραμματέα ΟΕΥ Γ

ΛΕΙΤΟΥΡΓΙΚΟΣ ΦΩΤΙΣΜΟΣ. Α. Τσαγκρασούλης Τμ. Αρχιτεκτόνων Μηχανικών, Πανεπιστήμιο Θεσσαλίας

Θεμελιώδη μεγέθη και νόμοι της φωτομετρίας και πρότυπα για έργα φωτισμού οδών, εξωτερικών χώρων και σηράγγων

Transcript:

Yangzhou Bright Solar Solutions Co., Ltd. Anbotek Compliance Laboratory Ltd Http://www.anbotek.com.cn Email:vic.zhou@anbotek.com Tel:+86-755-26066365 Fax:+86-755-26014772 Address:1/F, Building 1, SEC Industrial Park, No. 0409 Qianhai Road, Nanshan District, Shenzhen, 518054,Guangdong, China LumCAT: BR0-20W Luminaire: Report No: Voltage(V): 12.030 Test No: Current(A): 1.780 LampCAT: Power (W): 21.434 Lamp flux(lm) PF: 1.000 Number of Lamps: 1 Ballast type: Length(mm): 0 Width(mm): 0 Phm Type: C Height(mm): 0 Photometric Results Lumens(lm): 2050.62 Lumens(lm)/Power(W): 95.67 Central intensity(cd): 663.039 Maximum intensity(cd): 1163.117 Angle of maximum intensity: C=180.0 γ=45.0 Beam Angle(50%Imax): [C0/180]Left=69.9 Right=67.9 [C90/270]Left=35.6 Right=33.7 Field angle(10%imax): [C0/180]Left=77.0 Right=74.3 [C90/270]Left=64.9 Right=63.6 Maximum s/h: C0_180=2.30 C90_270=1.00 Up flux rate of LUM(%): 0.20% Down flux rate of LUM(%): 99.80% CIE Type : Direct lighting Output flux ratio in π solid angle : 84.442%

Zonal flux distribution table Page: 2 Total:16 γ( ) Average I(cd) Zonal F(lm) Sum F(lm) Eff Flux(%) Eff Sum(%) Sum/Lum(%) 0.0 662.033.000.000.000%.000%.000% 5.0 659.174 15.795 15.795.770%.770%.770% 10.0 657.340 47.096 62.890 2.297% 3.067% 3.067% 15.0 657.685 78.006 140.897 3.804% 6.871% 6.871% 20.0 642.116 107.122 248.019 5.224% 12.095% 12.095% 25.0 608.544 131.171 379.190 6.397% 18.492% 18.492% 30.0 589.121 151.566 530.755 7.391% 25.883% 25.883% 35.0 582.781 172.571 703.326 8.416% 34.298% 34.298% 40.0 569.540 192.256 895.582 9.376% 43.674% 43.674% 45.0 548.874 207.083 1102.666 10.099% 53.772% 53.772% 50.0 523.407 216.670 1319.336 10.566% 64.338% 64.338% 55.0 477.619 217.656 1536.992 10.614% 74.953% 74.953% 60.0 364.184 194.580 1731.572 9.489% 84.442% 84.442% 65.0 254.092 150.304 1881.876 7.330% 91.771% 91.771% 70.0 126.509 96.370 1978.247 4.700% 96.471% 96.471% 75.0 44.595 44.724 2022.970 2.181% 98.652% 98.652% 80.0 16.751 16.415 2039.385.800% 99.452% 99.452% 85.0 4.575 5.795 2045.180.283% 99.735% 99.735% 90.0.375 1.355 2046.535.066% 99.801% 99.801% 95.0.266.175 2046.711.009% 99.809% 99.809% 100.0.306.155 2046.866.008% 99.817% 99.817% 105.0.375.182 2047.048.009% 99.826% 99.826% 110.0.444.214 2047.262.010% 99.836% 99.836% 115.0.552.252 2047.514.012% 99.849% 99.849% 120.0.641.290 2047.804.014% 99.863% 99.863% 125.0.720.315 2048.119.015% 99.878% 99.878% 130.0.848.341 2048.459.017% 99.895% 99.895% 135.0.897.353 2048.812.017% 99.912% 99.912% 140.0.937.340 2049.152.017% 99.929% 99.929% 145.0.986.321 2049.472.016% 99.944% 99.944% 150.0.996.292 2049.764.014% 99.958% 99.958% 155.0 1.045.258 2050.022.013% 99.971% 99.971% 160.0.996.214 2050.237.010% 99.981% 99.981% 165.0.996.164 2050.401.008% 99.989% 99.989% 170.0 1.006.119 2050.519.006% 99.995% 99.995% 175.0 1.006.072 2050.591.004% 99.999% 99.999% 180.0 1.085.025 2050.616.001% 100.000% 100.000%

Zonal flux distribution table Page: 3 Total:16 ZONAL LUMEN SUMMARY Zone Lumens %Fixt 0-30 530.76 25.88% 0-40 895.58 43.67% 0-60 1731.57 84.44% 0-90 2046.54 99.80% 0-120 2047.80 99.86% 0-180 2050.62 100.00% 60-90 509.54 24.85% 90-120 2.62 0.13% 90-130 3.28 0.16% 90-150 4.58 0.22% 90-180 5.41 0.26% 0-57.66 1640.49 80.00% ZONAL LUMEN SUMMARY 0-10 62.89 10-20 185.13 20-30 282.74 30-40 364.83 40-50 423.75 50-60 412.24 60-70 246.67 70-80 61.14 80-90 7.15 90-100 0.33 100-110 0.40 110-120 0.54 120-130 0.66 130-140 0.69 140-150 0.61 150-160 0.47 160-170 0.28 170-180 0.07

Light Distribution Curve [Unit:cd] Page: 4 Total:16 ±180-150 150-120 120-90 232.62 90-60 465.25 697.87 60-30 930.49 1163.12 0 30 1163.12 930.49 697.87 465.25 232.62 0.00-180 -135-90 -45 0 45 90 135 180 C180(Max): C0/C180: C90/C270: Field angle(10%imax):c0/180left:77.0 Right:74.3 :C90/270Left:64.9 Right:63.6 Beam Angle(50%Imax):C0/180Left:69.9 Right:67.9 :C90/270Left:35.6 Right:33.7

Lux distance Curve Page: 5 Total:16 2.0m 165.8lux 10.4m 4.0m 41.4lux 20.8m 6.0m 18.4lux 31.2m 8.0m 10.4lux 41.6m 10.0m 6.6lux 52.0m Beam angle of C180plane137.85

ISO-Intensity(V-H) Page: 6 Total:16 90 [Unit:cd] Imax:1163.12cd 75 60 45 30 15 0-15 -30-45 -60-75 -90-90 -75-60 -45-30 -15 0 15 30 45 60 75 90 (10%Imax) 116.312 (20%Imax) 232.623 (30%Imax) 348.935 (40%Imax) 465.247 (50%Imax) 581.559 (60%Imax) 697.87 (70%Imax) 814.182 (80%Imax) 930.494 (90%Imax) 1046.81

ISO candela diagram on circular web Page: 7 Total:16 180 150 150 120 120 270 300 330 0 30 60 90 90 90 60 60 30 30 House 0 [Unit:cd] Imax:1163.12 (10%Imax) 116.312 (20%Imax) 232.623 (30%Imax) 348.935 (40%Imax) 465.247 (50%Imax) 581.559 (60%Imax) 697.87 (70%Imax) 814.182 (80%Imax) 930.494 (90%Imax) 1046.81 Road

ISO illuminance diagram Page: 8 Total:16 5.0d/h [Unit:lx] H=6.0m Emax:18.38 C 180 4.0 3.0 2.0 1.0 0.0 C 270 C 90 1.0 2.0 3.0 4.0 5.0d/h 5.0d/h C 0 4.0 3.0 2.0 1.0 0.0 1.0 2.0 3.0 4.0 5.0d/h (10%Emax) 1.838269 (20%Emax) 3.676528 (30%Emax) 5.514806 (40%Emax) 7.353083 (50%Emax) 9.191334 (60%Emax) 11.02961 (70%Emax) 12.86789 (80%Emax) 14.70617 (90%Emax) 16.54442

Space ISO Lux diagram Page: 9 Total:16 1.0m 2.0m 4.0m Imax:1163.12 [Unit:lx] 66.3038 132.608 198.912 265.215 331.519 397.823 464.127 530.431 596.735 6.0m 8.0m 10.0m 0.0m 1.0m 2.0m 3.0m 4.0m 5.0m 6.0m 7.0m 8.0m 9.0m

Luminance Limitting Curve(no luminous side) Page: 10 Total:16 Luminance Table γ 45 50 55 60 65 70 75 80 85 C0 0 0 0 0 0 0 0 0 0 C45 0 0 0 0 0 0 0 0 0 C90 0 0 0 0 0 0 0 0 0 Glare Table Glare Quality Service Values Illuminance(lx) 1.15 A 2000 1000 500 <=300 1.5 B 2000 1000 500 <=300 1.85 C 2000 1000 500 <=300 2.2 D 2000 1000 500 <=300 2.55 E 2000 1000 500 <=300 a b c d e f g h Luminance Limitting Curve γ( ) 85 75 65 a b c d e f g h 8 (a/hs) 6 4 3 2 55 45 6 7 8 9 1000 2 3 4 5 6 7 8 9 10000 2 3 4 L(cd/m²) C0 C45 C90

Budgetary Estimate Table Page: 12 Total:16 Budgetary Estimate Tab 40 Lamp Flux Maint Co 0.8/0.8 30 Ave Illu 100.0 lx Plane H 0.0 m Place C W F 20 Refl1 0.7 0.5 0.2 Refl2 0.5 0.3 0.2 [N] 10 9 8 7 6 5 4 3 2 1 6m 2m 1 2 3 4 5 6 7 8 9 10 20 S[m2] 40 60 80 100 200 400 600 800

Utilization factor table for indoor luminaire Page: 13 Total:16 RHOCC 80 70 50 30 10 0 RHOW 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 RCR COEFFCIENTS OF UTILIZATION RHOFC=20 CU 0 1.19 1.19 1.19 1.16 1.16 1.16 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.00 1 1.05 1.02 0.98 1.03 1.00 0.96 0.99 0.96 0.93 0.95 0.93 0.90 0.91 0.90 0.88 0.86 2 0.92 0.86 0.80 0.90 0.85 0.80 0.87 0.82 0.78 0.84 0.79 0.76 0.81 0.77 0.74 0.72 3 0.81 0.73 0.67 0.79 0.72 0.66 0.76 0.70 0.65 0.74 0.68 0.64 0.71 0.67 0.63 0.61 4 0.72 0.63 0.56 0.70 0.62 0.56 0.68 0.61 0.55 0.65 0.59 0.54 0.63 0.58 0.54 0.52 5 0.64 0.55 0.48 0.63 0.54 0.48 0.60 0.53 0.47 0.58 0.52 0.47 0.57 0.51 0.46 0.44 6 0.57 0.48 0.42 0.56 0.48 0.42 0.54 0.47 0.41 0.53 0.46 0.41 0.51 0.45 0.40 0.38 7 0.51 0.43 0.37 0.51 0.42 0.36 0.49 0.42 0.36 0.48 0.41 0.36 0.46 0.40 0.36 0.34 8 0.47 0.38 0.32 0.46 0.38 0.32 0.45 0.37 0.32 0.43 0.37 0.32 0.42 0.36 0.32 0.30 9 0.43 0.35 0.29 0.42 0.34 0.29 0.41 0.34 0.29 0.40 0.33 0.29 0.39 0.33 0.28 0.27 10 0.39 0.31 0.26 0.39 0.31 0.26 0.38 0.31 0.26 0.37 0.30 0.26 0.36 0.30 0.26 0.24

Coefficient Utilization Curve Page: 14 Total:16 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 3.0 2.7 2.4 2.1 1.8 1.5 1.2 0.9 0.6 0.3 0.0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 House Street Width/Height 0 5 10 15

Intensity data(cd) Page: 15 Total:16 C/γ( ) 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 0.0 663.04 655.94 656.41 658.94 676.45 719.04 851.24 1015.93 1115.32 22.5 663.99 662.09 658.94 660.99 675.34 679.92 725.51 788.45 817.64 45.0 661.78 656.26 656.73 654.68 636.69 603.41 559.24 521.85 464.74 67.5 666.82 656.89 650.58 637.17 585.42 512.23 459.22 356.21 286.80 90.0 661.78 652.94 649.16 623.60 563.97 481.15 395.96 308.57 233.16 112.5 662.41 652.63 645.69 637.80 586.53 518.22 451.33 364.41 297.05 135.0 661.30 656.73 648.84 654.05 649.63 613.50 560.50 513.01 463.80 157.5 658.46 656.10 654.68 679.29 695.54 670.77 682.13 730.71 777.09 180.0 656.41 654.52 661.93 683.39 684.02 690.33 751.85 910.40 1077.77 202.5 663.99 662.57 668.72 684.34 697.11 676.29 696.80 746.02 806.59 225.0 661.78 664.93 662.41 668.40 672.66 651.52 577.38 531.47 492.35 247.5 666.82 666.51 659.88 653.26 610.82 546.46 477.36 414.10 318.19 270.0 661.78 662.09 659.25 648.05 589.84 510.33 429.56 341.22 261.56 292.5 662.41 665.72 659.88 652.94 618.24 545.35 475.00 413.63 324.18 315.0 661.30 661.30 659.09 659.09 651.21 623.92 584.32 546.30 510.02 337.5 658.46 659.57 665.25 666.98 680.39 694.27 748.54 822.21 866.38 360.0 663.04 655.94 656.41 658.94 676.45 719.04 851.24 1015.93 1115.32 C/γ( ) 45.0 50.0 55.0 60.0 65.0 70.0 75.0 80.0 85.0 0.0 1153.65 1098.91 924.75 724.72 514.28 198.45 44.96 10.10 1.74 22.5 846.51 879.32 853.45 627.39 439.34 193.09 45.12 12.78 1.58 45.0 414.10 359.05 299.57 213.76 103.96 47.17 25.87 9.31 0.95 67.5 226.69 189.62 162.49 120.05 66.41 43.22 24.29 16.56 3.31 90.0 191.83 166.43 139.30 97.33 53.64 35.02 20.98 10.41 2.21 112.5 232.84 195.30 172.58 132.04 75.41 46.54 27.92 16.72 10.73 135.0 409.69 360.78 290.42 225.59 136.61 64.84 31.24 15.62 3.16 157.5 800.92 802.18 829.00 684.02 521.38 277.49 77.46 21.93 4.10 180.0 1163.12 1152.71 1041.02 775.36 659.57 326.08 94.81 22.87 4.26 202.5 830.10 848.87 861.02 683.23 524.06 298.00 95.91 24.14 4.73 225.0 431.61 373.25 306.36 245.15 140.24 67.99 35.81 20.19 4.57 247.5 251.77 206.34 176.37 126.36 82.35 51.59 32.81 22.09 13.41 270.0 204.76 178.10 145.76 100.17 65.15 44.01 27.76 14.83 5.36 292.5 260.14 211.07 177.79 131.25 82.19 51.43 34.23 23.35 8.68 315.0 462.53 404.32 328.76 250.04 120.68 55.84 30.76 13.41 2.37 337.5 901.72 948.26 933.27 690.49 480.20 223.38 63.57 13.72 2.05 360.0 1153.65 1098.91 924.75 724.72 514.28 198.45 44.96 10.10 1.74 C/γ( ) 90.0 95.0 100.0 105.0 110.0 115.0 120.0 125.0 130.0 0.0 0.32 0.16 0.32 0.47 0.63 0.79 0.95 0.95 1.10 22.5 0.32 0.32 0.32 0.47 0.63 0.95 1.10 1.26 1.26 45.0 0.32 0.16 0.32 0.32 0.63 0.47 0.79 0.95 0.95 67.5 0.16 0.16 0.32 0.32 0.32 0.47 0.47 0.63 0.79 90.0 0.32 0.16 0.16 0.32 0.32 0.32 0.47 0.47 0.63 112.5 0.32 0.32 0.32 0.32 0.32 0.32 0.47 0.47 0.47 135.0 0.47 0.32 0.32 0.32 0.32 0.47 0.47 0.63 0.79 157.5 0.63 0.47 0.47 0.47 0.63 0.79 0.79 0.95 0.95 180.0 0.63 0.47 0.63 0.63 0.79 0.95 1.10 1.10 1.42 202.5 0.63 0.32 0.32 0.47 0.63 0.63 0.63 0.79 0.95 225.0 0.32 0.32 0.16 0.32 0.32 0.47 0.47 0.63 0.63 247.5 0.32 0.16 0.16 0.32 0.16 0.32 0.32 0.32 0.47 270.0 0.32 0.16 0.16 0.32 0.16 0.16 0.32 0.16 0.47 292.5 0.32 0.32 0.32 0.16 0.32 0.32 0.32 0.47 0.63 315.0 0.32 0.16 0.32 0.32 0.32 0.63 0.63 0.79 0.79 337.5 0.32 0.32 0.32 0.47 0.63 0.79 0.95 0.95 1.26 360.0 0.32 0.16 0.32 0.47 0.63 0.79 0.95 0.95 1.10

Intensity data(cd) Page: 16 Total:16 C/γ( ) 135.0 140.0 145.0 150.0 155.0 160.0 165.0 170.0 175.0 0.0 1.26 1.10 1.26 1.10 1.10 0.95 0.95 0.95 0.95 22.5 1.26 1.26 1.10 1.10 1.10 1.10 1.10 0.95 1.10 45.0 1.10 0.95 1.10 1.10 1.26 0.95 1.10 1.10 0.95 67.5 0.79 0.95 0.79 0.95 1.10 1.10 1.10 1.10 1.10 90.0 0.47 0.79 0.79 0.95 1.10 1.10 1.10 1.10 1.10 112.5 0.79 0.63 0.79 0.95 0.95 1.10 0.95 1.10 1.10 135.0 0.79 0.95 0.95 0.95 1.10 0.95 1.10 0.95 1.10 157.5 0.95 1.10 1.10 1.10 1.10 1.10 0.95 0.95 0.95 180.0 1.26 1.26 1.26 1.10 1.10 0.95 0.95 0.95 0.95 202.5 1.10 0.95 1.10 1.10 1.10 0.95 0.95 1.10 0.95 225.0 0.79 0.79 0.95 0.79 0.95 0.95 0.95 0.95 0.95 247.5 0.47 0.79 0.63 0.79 0.95 0.95 0.95 1.10 1.10 270.0 0.63 0.63 0.79 0.79 0.79 0.95 0.95 0.95 1.10 292.5 0.63 0.79 0.95 0.95 0.95 0.95 0.95 0.95 0.95 315.0 0.95 0.95 1.10 1.10 1.10 0.95 0.95 0.95 0.95 337.5 1.10 1.10 1.10 1.10 0.95 0.95 0.95 0.95 0.79 360.0 1.26 1.10 1.26 1.10 1.10 0.95 0.95 0.95 0.95 C/γ( ) 180.0 0.0 1.10 22.5 1.10 45.0 0.95 67.5 1.10 90.0 1.10 112.5 1.10 135.0 1.10 157.5 1.10 180.0 1.10 202.5 1.10 225.0 0.95 247.5 1.10 270.0 1.10 292.5 1.10 315.0 1.10 337.5 1.10 360.0 1.10