with serial RS485/RS232 output RS485
|
|
- Πολυξένη Ηλιόπουλος
- 6 χρόνια πριν
- Προβολές:
Transcript
1 with serial RS485/RS232 output RS485 2
2 Applications Měřící a záznamový systém MS v různých provedeních Building management 2 Industry Meteorology Pharmaceuticals and laboratories Technological processes and production In the food industry, environments, supermarkets Healthcare and laboratories 2 Measured values SCADA / PLC systems Temperature Relative humidity RS485 Computed values Barometric pressure Carbon dioxide level - CO Binary inputs Food industry Building management 2 3
3 Sensors and regulators with serial output RS485/RS232 and with relay outputs 2 H Programmable industry regulators with relay output and serial output RS485/RS232 Basic division of devices: T Programmable sensors with serial output without relay outputs Programmable industry regulators H Regulators with relay outputs 2 50V»»»»» page 6-7 page 5-11 page Regulators with power relay outputs 250V page 6-7 Regulators with two-state inputs, with relay output and serial output RS485/RS232 50V Advantages: Advantages: 2 page
4 (150) Programmable industry regulators Choose the appropriate sensor model H Electrical wiring of regulator with low voltage relay output. Regulators with relay and power relay output 2 power supply relay 1 relay 2 Connector for SP003 cable connection to a computer USB port 2 MEASURED VALUES temperature + relative humidity Temperature + relative humidity + CO 2 C0 2 H3020 H3023 H3021 H3021P H6020 H5021 H5024 H H3061 H3061P holes for device mounting Normally open contact of relay Normally closed contact of relay relay 1 relay Electrical wiring of regulator with power relay output. Connector for SP003 cable connection to a computer USB port internal fuse T1,25A power supply Vac holes for device mounting «155 (88) 1(2,4) m HEX 19 O-ring G1/2 1(2,4) m Computed humidity values Dew point temperature Absolute humidity Mixing ratio 7
5 Programmable industry regulators H Regulators with two-state inputs, with relay output and serial output RS485/RS232 Terminal for power and signal RS485/RS232 LED signalization Relay Connection of external power relay External power relay Power supply Coil data chart of external power relay: Keypad Electrical wiring of regulator with serial output RS485 Electrical wiring of regulator with serial output RS232 Acoustic alarm 9to30V Power from a PC port Power from an external source Another device connection 9to30V Binary inputs terminals +U are internally connected to the device power supply relay 1 relay 2 External probe Binary inputs terminals +U are connected via an diodes to DTR and RTS terminals relay 1 relay 2 External probe Design Three binary inputs 2 9
6 (150) Programmable industry regulators Choose the appropriate sensor model H Regulators with relay and serial output RS485/RS232 2 MEASURED VALUES temperature temperature + relative humidity temperature + relative humidity temperature + relative humidity + atm. pressure temperature + relative humidity + CO 2 C0 2 H4431 H0430 H3430 H3433 H3431 H3431P H7430 H7431 H6420 H5421 H5424 H H3331 H3331P - H7331 H6320 H5321 H Computed humidity values 155 (88) 1(2,4) m HEX 19 O-ring 1(2,4) m (88) 1(2,4) m 150 G1/2 Dew point temperature Absolute humidity Mixing ratio.5 11
7 T 2 Programmable sensors with serial output without relay Programmable sensors with serial output RS485/RS232 line RS485 LED indication Industry design Electrical wiring of sensor with serial output RS485 power 9-30V Device I Device II Electrical wiring of sensor with serial output RS232 Terminal for power and signal RS485/RS232 Sensor version with watertight male connector TxxxxL External mounting holes Supply from communication port red (yellow) red (brown) green white Supply from communication port power 9-30V red (yellow) red (brown) Note: Sensors of concentration CO 2 is not possible to power from communication port. Sealing lid Female Lumberg connection for sensor with RS232 output The stem Female Lumberg connection for sensor with RS485 output from stainless steel mesh Case of sensor Sensor version TxxxxD Measuring elements 13
8 Programmable sensors with serial output without relay MEASURED VALUES temperature temperature + relative humidity 2 T4411 T0410 T3411 T3413(D), T3417(D) temperature + relative humidity temperature + relative humidity + atm. pressure atm. pressure temperature + relative humidity + CO 2 C0 2 T3419 T3419P T7410 T7411 T2414 T6440 T5441 T5440 T4311 T0310 T3311 T3313 T3319 T3319P T7310 T7311 T2314 T6340 T5341 T5340 T Programmable sensors with serial output RS485/RS232 Industry design 2 2 probe probe Computed humidity values Dew point temperature Absolute humidity Mixing ratio 15
9 Interior design T Programmable sensors with serial output RS485 and RS232 Optional accessories for sensors and regulators Mounting accessories PP90 PP4 2 K1427 SP004 MEASURED VALUES temperature temperature + relative humidity temperature + relative humidity + atm. pressure temperature + C0 2 T0418 T3418 T7418 T8448 T0318 T3318 T Computed humidity values Dew point temperature Absolute humidity Mixing ratio Calibration Detectors SD-280 LD-12 Communication SP009 SH-PP MD046 HM023 HM024 SP008 SA200A MP022 Protection of sensors F5200 F5200B F F5300 JS-20 MP006 Cometeo F8100 Power supply A
10 Comet Database - Monitoring of temperature, relative humidity, atmospheric pressure and CO 2 Comprehensive system multiple networks RS485 Sensors RS485 utility supports»»»» Sensor RS485/232 utility Comet Database Basic solution TSensor Program Tsensor for sensor setting is available to download for free. Comet Database also exists in 30 days trial version. So you can test it without any worries. SensorReader Freeware software for displaying and logging data from one COMET sensor. The software stores measured values- - sensor failure. What does Comet Database offer?»»»»» Comet Database Viewer 19
11 Mess-, Steuer-und Regelgeräte GmbH - Phone: Fax: wuntronic@wuntronic.de Internet:
Overview: Relay Modules
20 Overview: Relay Modules 859 Series 857 Series 788 Series 858 Series 288 and 287 Series 286 Series 789 Series Relays with Changeover Contacts 1 changeover contact Item No. Page Item No. Page Item No.
38BXCS STANDARD RACK MODEL. DCS Input/Output Relay Card Series MODEL & SUFFIX CODE SELECTION 38BXCS INSTALLATION ORDERING INFORMATION RELATED PRODUCTS
DCS Input/Output Relay Card Series STANDARD RACK MODEL 38BXCS MODEL & SUFFIX CODE SELECTION 38BXCS MODEL CONNECTOR Y1 :Yokogawa KS2 cable use Y2 :Yokogawa KS9 cable use Y6 :Yokogawa FA-M3/F3XD32-3N use
Industrial Pressure Transmitter
NAT 8 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The industrial transmitter
DIRIS A60 Multifunction meters - PMD Energy monitoring and event analysis - dimensions 96x96 mm
Energy monitoring and event analysis - dimensions 96x96 mm Metering, monitoring & power quality Principle diagram DIRIS A40 DIRIS A40 DIRIS A40 Ethernet The solution for > Industry. > Infrastructure. >
Return Line Filters Type RTF10/25
Technical Data Type RTF1/25 Product Description Technical Data Construction Materials Filter head: Sealings: Aluminum NR (una-n ) Other sealing materials on request Options and Accessories Valve Clogging
Datasheet * * Remotely Configurable Digital Pressure Transmitter. Application. Construction and mode of operation. Features.
*0900581* DB_EN_ME12 Rev.B 06/1 *0900581* d e v e l o p i n g s o l u t i o n s ME12 Datasheet Remotely Configurable Digital Pressure Transmitter Application Pressure transmitter with a ceramic measuring
Digital motor protection relays
Digital motor protection relays Specification DMP -S & DMP -Sa DMP -T & DMP -Ta Model No. DMP06-S/Sa DMP60-S/Sa DMP06-T/Ta DMP60-T/Ta Wiring Screw type Tunnel type Panel mount Unit or Extension Note1)
SPEEDO AQUABEAT. Specially Designed for Aquatic Athletes and Active People
SPEEDO AQUABEAT TM Specially Designed for Aquatic Athletes and Active People 1 2 Decrease Volume Increase Volume Reset EarphonesUSBJack Power Off / Rewind Power On / Fast Forward Goggle clip LED Status
Features. Terminal Contact Enclosure style style form Open type Dust cover Ears on cover Antirotation-tab Ears on top
SONG CHUN Features 20/2 general purpose Power Relays. SPDT, DPDT, TPDT contact configurations. DC & C coils are both available. Optional for flange covers, tapped core w/anti-rotation tab, indicator lamp,
SMD Wire Wound Ferrite Chip Inductors - LS Series. LS Series. Product Identification. Shape and Dimensions / Recommended Pattern LS0402/0603/0805/1008
SMD Wire Wound Ferrite Chip Inductors - LS Series LS Series LS Series is the newest in open type ferrite wire wound chip inductors. The wire wound ferrite construction supports higher SRF, lower DCR and
Siemens AG Rated current 1FK7 Compact synchronous motor Natural cooling. I rated 7.0 (15.4) 11.5 (25.4) (2.9) 3.3 (4.4)
Synchronous motors Siemens 2009 FK7 Compact motors Nural cooling Selection and ordering da Red speed Shaft height n red S P red ΔT=00 K rpm kw (P) Red power Stic torque M 0 ΔT=00 K Red torque ) M red ΔT=00
Ventilated Distribution Transformers
General Purpose Energy efficient dry-type transformers 600 Volt Class, isolation type, single and three phase, 1 through 00. Indoor and outdoor models available. Accessories and Optional Styles trostatic
Project: 296 File: Title: CMC-E-600 ICD Doc No: Rev 2. Revision Date: 15 September 2010
Project: 296 File: Title: CMC-E-600 ICD Doc No: 21029100-406 Rev 2. Revision Date: 15 September 2010 Contract No.: Revisions Table ECR/ECN LTR Description Date 0 Pre Contract draft 29 July 2010 1 Replace
!!! )!)(!,!! )!! )! (!!)!
! # %&!!!!! # %& (!!! # %&! ( ) # %&!! )! )!!!!! (! )! +!!! )!)(!,!! )!! )! (!!)!!!!,!!!!! + (!!)! ).!!!)( / ) 0!!!!!!! + (!!!,! + ( ( 5 % 6! & ) & 7 8!+ 9 ## 78 ## # #5! 7! /, #:6 ;! 7 )! & 9 ) 5< 7 )
ADVANCE LINE. Επώνυµα Συστήµατα
ADVANCE LINE Επώνυµα Συστήµατα Ασφαλείας & Επικοινωνίας ΚΑΤΑΛΟΓΟΣ 2015 Branded Security & Communication Systems CATALOGUE 2015 NEC SL-1000 NEC SL-1000 ΚΑΤΑΛΟΓΟΣ 2015 CATALOGUE 2015 81 Επώνυμα Συστήματα
Daewoo Technopark A-403, Dodang-dong, Wonmi-gu, Bucheon-city, Gyeonggido, Korea LM-80 Test Report
LM-80 Test Report Approved Method: Measuring Lumen Maintenance of LED Light Sources Project Number: KILT1212-U00216 Date: September 17 th, 2013 Requested by: Dongbu LED Co., Ltd 90-1, Bongmyeong-Ri, Namsa-Myeon,
2. Laser Specifications 2 1 Specifications IK4301R D IK4401R D IK4601R E IK4101R F. Linear Linear Linear Linear
2. Laser Specifications 2 1 Specifications IK4301R D IK4401R D IK4601R E IK4101R F 441.6 441.6 441.6 441.6 30 50 70 100 TEM00 TEM00 TEM00 TEM00 BEAM DIAMETER ( 1/e2) 1.1 1.1 1.2 1.2 0.5 0.5 0.5 0.4 RATIO
Stainless steel measuring tape Analog output U8 I1. ±0.10 % f. s. (standard); ±0.05 % (optional) Protection class IP68/IP69K
Analog Output Position sensor with measuring tape Measurement range up to 10000 mm class IP68/IP69K Stainless steel measuring tape Analog output Specifications Outputs Resolution Sensing device Material
Return Line Filters. Return Line Filters Type RTF10/25. C Technology. Filtration. Product Description. Technical Data. Options and Accessories
Return Line Filters Return Line Filters Type RTF1/25 Product Description Technical Data Options and Accessories Construction Materials Valve Clogging Indicators Port Connection Flow Rating Operating Pressure
ISM 868 MHz Ceramic Antenna Ground cleared under antenna, clearance area mm x 8.25 mm. Pulse Part Number: W3013
W0 Datasheet version.. Ceramic Antenna. (0/08). Ceramic Antenna Ground cleared under antenna, clearance area 0.80 mm x 8.5 mm. Pulse Part Number: W0 Features - Omni directional radiation - Low profile
4 Way Reversing Valve
STANDARD 4 Way Reversing Valve SHF series four-way reversing valves are applicable for heat pump systems such as central, unitary and room air conditioners to realize switching between cooling mode and
Specification. code ±1.0 ±1.0 ±1.0 ±1.0 ±0.5 approx (g)
High CV-value Long Life > 10 years at 50 C Low ESR and ESL High stability, 10 years shelf life Optimized designs available on request RoHS Compliant application Basic design Smoothing, energy storage,
Quick Installation Guide
A Installation 1 F H B E C D G 2 www.trust.com/17528/faq Quick Installation Guide C C D Freewave Wireless Audio Set 17528/ 17529 D Installation Configuration Windows XP 4 5 8 Windows 7/ Vista 6 7 9 10
Accessories 2-WIRE PROGRAMMABLE TRANSMITTERS. 5331D Features: 5333D Features: 5334B Features: Typical Applications: Mounting and Installation:
2WIRE PROGRAMMABLE TRANSMITTERS 5331D Features: RTD, Thermocouple, Ohm, or mv input Extremely high measurement accuracy 1.5 kvac galvanic isolation 5333D Features: RTD or Ohm input High measurement accuracy
Gearmotor Data. SERIES GM9000: We have the GM9434H187-R1
SERIES GM9: We have the GM9434H187-R1 Gearmotor Data Item Parameter Symbol Units 5.9:1 11.5:1 19.7:1 38.3:1 65.5:1 127.8:1 218.4:1 425.9:1 728.1:1 1419.8:1 2426.9:1 4732.5:1 1 Max. Load Standard Gears
Model: MTZ22. Data. Cylinder count: 1 Displacement [m³/h]: 6,63 Cylinder capacity [cm³]: 38,1 RPM [min -1 ]: 2900 Weight [kg]: 21 Oil charge [dm³]: 1
Technical data Data Cylinder count: 1 Displacement [m³/h]: 6,63 Cylinder capacity [cm³]: 38,1 RPM [min -1 ]: 2900 Weight [kg]: 21 Oil charge [dm³]: 1 Oil type: 160PZ Crankcase heater type: PTC 35 W Maximum
Precision Metal Film Fixed Resistor Axial Leaded
Features EIA standard colour-coding Non-Flame type available Low noise and voltage coefficient Low temperature coefficient range Wide precision range in small package Too low or too high ohmic value can
Terminal Contact UL Insulation Designation (provided with) style form system approval Flux tight
eatures A miniature PCB Power Relay. form A contact configuration with quick terminal type. 5KV dielectric strength, K surge voltage between coils to contact. Ideal for high rating Home Appliances of heating
SMD Transient Voltage Suppressors
SMD Transient Suppressors Feature Full range from 0 to 22 series. form 4 to 60V RMS ; 5.5 to 85Vdc High surge current ability Bidirectional clamping, high energy Fast response time
ΠΡΟΣΚΛΗΣΗ ΕΝΔΙΑΦΕΡΟΝΤΟΣ KAI ΚΑΤΑΘΕΣΗΣ ΠΡΟΣΦΟΡΩΝ ΓΙΑ ΤΗΝ ΑΝΑΘΕΣΗ ΤΗΣ ΠΡΟΜΗΘΕΙΑΣ
ΕΘΝΙΚΟ ΚΕΝΤΡΟ ΕΡΕΥΝΑΣ ΚΑΙ ΤΕΧΝΟΛΟΓΙΚΗΣ ΑΝΑΠΤΥΞΗΣ (Ε.Κ.Ε.Τ.Α.) / Ινστιτούτο Χημικών Διεργασιών και Ενεργειακών Πόρων (ΙΔΕΠ) Θεσσαλονίκη, 28-02-209 Αριθμ. Πρωτ.: 000674 ΠΡΟΣΚΛΗΣΗ ΕΝΔΙΑΦΕΡΟΝΤΟΣ KAI ΚΑΤΑΘΕΣΗΣ
TODA-ISU Corporation. SMD Power Inductor. SPI series. SMD Team
SMD Power Inductor SPI series TODA-ISU Corporation Advantages & Applications Advantages Low profile High current capability & Low DCR Low temperature rise Increased thermal efficiency Patent (Coil Integrated
Test Data Management in Practice
Problems, Concepts, and the Swisscom Test Data Organizer Do you have issues with your legal and compliance department because test environments contain sensitive data outsourcing partners must not see?
ISM 900 MHz Ceramic Antenna Ground cleared under antenna, clearance area mm x 8.25 mm. Pulse Part Number: W3012
W0 Datasheet version.. Ceramic Antenna. (0/08). Ceramic Antenna Ground cleared under antenna, clearance area 0.80 mm x 8.5 mm. Pulse Part Number: W0 Features - Omni directional radiation - Low profile
Διπλωματική Εργασία του φοιτητή του Τμήματος Ηλεκτρολόγων Μηχανικών και Τεχνολογίας Υπολογιστών της Πολυτεχνικής Σχολής του Πανεπιστημίου Πατρών
ΠΑΝΕΠΙΣΤΗΜΙΟ ΠΑΤΡΩΝ ΤΜΗΜΑ ΗΛΕΚΤΡΟΛΟΓΩΝ ΜΗΧΑΝΙΚΩΝ ΚΑΙ ΤΕΧΝΟΛΟΓΙΑΣ ΥΠΟΛΟΓΙΣΤΩΝ ΤΟΜΕΑΣ:ΗΛΕΚΤΡΟΝΙΚΗΣ ΚΑΙ ΥΠΟΛΟΓΙΣΤΩΝ ΕΡΓΑΣΤΗΡΙΟ ΗΛΕΚΤΡΟΝΙΚΩΝ ΕΦΑΡΜΟΓΩΝ Διπλωματική Εργασία του φοιτητή του Τμήματος Ηλεκτρολόγων
SPBW06 & DPBW06 series
/,, MODEL SELECTION TABLE INPUT ORDER NO. INPUT VOLTAGE (RANGE) NO LOAD INPUT CURRENT FULL LOAD VOLTAGE CURRENT EFFICIENCY (TYP.) CAPACITOR LOAD (MAX.) SPBW06F-03 310mA 3.3V 0 ~ 1500mA 81% 4700μF SPBW06F-05
HORIZON QUANTUM. Logging
HORIZON QUANTUM High Capacity Packet Microwave System FEATURES NETWORK MANAGEMENT (NMS) Capacity w/accelerator Variable from 10 to 2000 Mbps full duplex CIR Management Access In or out of band 2x capacity
OUR PRODUCT RANGE. www.rakson.gr
ΤΑ ΑΛΛΑ ΕΙ Η ΠΡΟΪΟΝΤΑ ΜΑΣ ΜΕΤΑΣΧΗΜΑΤΙΣΤΕΣ ΚΟΥ ΟΥΝΙΩΝ ΚΟΥ ΟΥΝΙΑ ΜΠΟΥΤΟΝ ΚΟΥ ΟΥΝΙΩΝ ΑΥΤΟΜΑΤΟΙ ΚΛΙΜΑΚΟΣΤΑΣΙΟΥ ΚΛΕΙ ΑΡΙΕΣ ΑΝΙΧΝΕΥΤΕΣ ΚΙΝΗΣΗΣ ΣΥΣΤΗΜΑΤΑ ΕΠΙΚΟΙΝΩΝΙΑΣ Θυροτηλεοράσεις Θυροτηλέφωνα Ενδοεπικοινωνίες
RSDW08 & RDDW08 series
/,, MODEL SELECTION TABLE INPUT ORDER NO. INPUT VOLTAGE (RANGE) NO LOAD INPUT CURRENT FULL LOAD VOLTAGE CURRENT EFFICIENCY (Typ.) CAPACITOR LOAD (MAX.) RSDW08F-03 344mA 3.3V 2000mA 80% 2000μF RSDW08F-05
Metal Oxide Varistors (MOV) Data Sheet
Φ SERIES Metal Oxide Varistors (MOV) Data Sheet Features Wide operating voltage (V ma ) range from 8V to 0V Fast responding to transient over-voltage Large absorbing transient energy capability Low clamping
ΑΥΤΟΜΑΤΟΠΟΙΗΣΗ ΜΟΝΑΔΑΣ ΘΡΑΥΣΤΗΡΑ ΜΕ ΧΡΗΣΗ P.L.C. AUTOMATION OF A CRUSHER MODULE USING P.L.C.
ΤΕΧΝΟΛΟΓΙΚΟ ΕΚΠΑΙΔΕΥΤΙΚΟ ΙΔΡΥΜΑ ΑΝ. ΜΑΚΕΔΟΝΙΑΣ ΚΑΙ ΘΡΑΚΗΣ ΣΧΟΛΗ ΤΕΧΝΟΛΟΓΙΚΩΝ ΕΦΑΡΜΟΓΩΝ ΤΜΗΜΑ ΗΛΕΚΤΡΟΛΟΓΩΝ ΜΗΧΑΝΙΚΩΝ Τ.Ε ΠΤΥΧΙΑΚΗ ΕΡΓΑΣΙΑ ΑΥΤΟΜΑΤΟΠΟΙΗΣΗ ΜΟΝΑΔΑΣ ΘΡΑΥΣΤΗΡΑ ΜΕ ΧΡΗΣΗ P.L.C. AUTOMATION OF A
Installation Instructions Electronic pressure sensor. PTD25-10-xxxxx PTD25-20-xxxxx
Installation Instructions Electronic pressure sensor PTD25-10-xxxxx PTD25-20-xxxxx 7048 / 00 07 / 2010 Contents Safety instructions... 2 Function and features... Installation... 4 Electrical connection...
ΕΛΕΓΧΟΣ ΚΑΙ ΤΡΟΦΟΔΟΤΗΣΗ ΜΕΛΙΣΣΟΚΟΜΕΙΟΥ ΑΠΟ ΑΠΟΣΤΑΣΗ
ΕΘΝΙΚΟ ΜΕΤΣΟΒΙΟ ΠΟΛΥΤΕΧΝΕΙΟ ΣΧΟΛΗ ΗΛΕΚΤΡΟΛΟΓΩΝ ΜΗΧΑΝΙΚΩΝ ΚΑΙ ΜΗΧΑΝΙΚΩΝ ΥΠΟΛΟΓΙΣΤΩΝ ΤΟΜΕΑΣ ΗΛΕΚΤΡΙΚΩΝ ΒΙΟΜΗΧΑΝΙΚΩΝ ΔΙΑΤΑΞΕΩΝ ΚΑΙ ΣΥΣΤΗΜΑΤΩΝ ΑΠΟΦΑΣΕΩΝ ΕΛΕΓΧΟΣ ΚΑΙ ΤΡΟΦΟΔΟΤΗΣΗ ΜΕΛΙΣΣΟΚΟΜΕΙΟΥ ΑΠΟ ΑΠΟΣΤΑΣΗ
Transient Voltage Suppression Diodes: 1.5KE Series Axial Leaded Type 1500 W
Features 1. Reliable low cost construction utilizing molded plastic technique 2. Both bi-directional and uni-directional devices are available 3. Fast response time 4. Excellent clamping capacity 5. 1500
U8 I1. Linearity ±0.10 % f. s.; optional ±0.05 % WB85
Analog Output Position sensor with measuring tape Measurement range up to 6000 mm class IP67/IP69K Stainless steel measuring tape Analog output Specifications Outputs Resolution U2 U8 I1 Voltage 0.5...
NMBTC.COM /
Common Common Vibration Test:... Conforms to JIS C 60068-2-6, Amplitude: 1.5mm, Frequency 10 to 55 Hz, 1 hour in each of the X, Y and Z directions. Shock Test:...Conforms to JIS C 60068-2-27, Acceleration
TIME SWITCHES AND TWILIGHT SWITCHES
W ANALOG DIN-RAIL TIME SWITCH QUARTZ, SERIES TEMPUS ANALOG 244 W SCHRACK-INFO Analogue time switch 1 channel Daily program With power reserve (NiMH rechargeable battery) Synchronised with mains Shortest
Thermistor (NTC /PTC)
ISO/TS16949 ISO 9001 ISO14001 2015 Thermistor (NTC /PTC) GNTC (Chip in Glass Thermistor) SMD NTC Thermistor SMD PTC Thermistor Radial type Thermistor Bare Chip Thermistor (Gold & silver Electrode) 9B-51L,
TMA4115 Matematikk 3
TMA4115 Matematikk 3 Andrew Stacey Norges Teknisk-Naturvitenskapelige Universitet Trondheim Spring 2010 Lecture 12: Mathematics Marvellous Matrices Andrew Stacey Norges Teknisk-Naturvitenskapelige Universitet
ΑΝΙΧΝΕΥΣΗ ΓΕΓΟΝΟΤΩΝ ΒΗΜΑΤΙΣΜΟΥ ΜΕ ΧΡΗΣΗ ΕΠΙΤΑΧΥΝΣΙΟΜΕΤΡΩΝ ΔΙΠΛΩΜΑΤΙΚΗ ΕΡΓΑΣΙΑ
ΕΘΝΙΚΟ ΜΕΤΣΟΒΙΟ ΠΟΛΥΤΕΧΝΕΙΟ ΣΧΟΛΗ ΗΛΕΚΤΡΟΛΟΓΩΝ ΜΗΧΑΝΙΚΩΝ ΚΑΙ ΜΗΧΑΝΙΚΩΝ ΥΠΟΛΟΓΙΣΤΩΝ ΤΟΜΕΑΣ ΕΠΙΚΟΙΝΩΝΙΩΝ ΗΛΕΚΤΡΟΝΙΚΗΣ ΚΑΙ ΣΥΣΤΗΜΑΤΩΝ ΠΛΗΡΟΦΟΡΙΚΗΣ ΑΝΙΧΝΕΥΣΗ ΓΕΓΟΝΟΤΩΝ ΒΗΜΑΤΙΣΜΟΥ ΜΕ ΧΡΗΣΗ ΕΠΙΤΑΧΥΝΣΙΟΜΕΤΡΩΝ
ΓΙΑΝΤΣΗΣ ΧΡΗΣΤΟΣ. Θέμα εργασίας: Υποθαλάσσια & υπόγεια δίκτυα αισθητήρων. Work title: Underwater & underground sensor networks
Πανεπιστήμιο Μακεδονίας ΠΜΣ Πληροφοριακά Συστήματα Τεχνολογίες Τηλεπικοινωνιών & Δικτύων Καθηγητής: Α.Α. Οικονομίδης University of Macedonia Master Information Systems Networking Technologies Professor:
SMD Shielded Power Inductors SPIA Series. SPIA Series. Product Identification
SPIA Series SPIA series is an automatic assembly constructed power inductor which is shielded with ferrite core. It is ideal for portable device DC-DC converter line. Features RoHS Compliant Miniature
EZ-One Pro PC Based Control Systems Complete system, supports from 1 to 8 doors
EZ-One Pro PC Based Control Systems Complete system, supports from 1 to 8 doors The EZ-One Pro series are complete access control systems designed for fast and easy installation. EZ-One Pro systems can
Pos. Article Completion Voltage Art.-/SAP-No. 101 SP Steam Outlet Hose, RS lbs/hr
2589893 EN 1703 Nortec RS SPARE PARTS Subject to change! Pos. Article Completion Voltage Art.-/SAP-No. 101 SP Steam Outlet Hose, RS 10...180 lbs/hr 1 1 1 1 1 1 1 1 2584885 102 SP Plumbing Element Plug
U8 I1. Linearity ±0.10 % f. s.; optional ±0.05 % WB21
Analog Output Position sensor with measuring tape Measurement range up to 20,000 mm class IP67/IP69K Stainless steel measuring tape Analog output Specifications Outputs Resolution U2 U8 I1 Voltage 0.5...
FDL - FXDL FBDL SERIES
FDL - FXDL FBDL SERIES SUBMERSIBLE PUMPS FOR WITH ENTRAINED SOLIDS WASTE WATER Sewage pumps with power up to 22 kw (30 HP). Available in cast iron (FDL), AISI 316 stainless steel (FXDL), B10 bronze (FBDL).
S /5000 BTU/Hr. 1000/1500 Watt
763.576.32 SPEC-168 D763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners SPECTRACOOL SLIM FIT INDOOR S6 1/17 BTU/Hr. 3/5 Watt S1 34/5 BTU/Hr. 1/15 Watt
Καλωδιώσεις διπλής. Οδηγίες εγκατάστασης. 1.0 Εισαγωγή. 2.0 Εγκατάσταση
Καλωδιώσεις διπλής Οδηγίες εγκατάστασης D1L/D1 1.0 Εισαγωγή Οι καλωδιώσεις διπλής D1L και D1 προστατεύουν τον τεχνικό εγκατάστασης και την μπαταρία, με τη σύνδεση δύο μπαταριών σε παράλληλη διάταξη με
ΕΛΕΓΧΟΣ ΑΝΤΛΙΟΣΤΑΣΙΟΥ ΜΕ ΔΕΞΑΜΕΝΗ ΜΕΣΩ GSM CHECK IN TANK PUMPING THROUGH GSM
ΣΧΟΛΗ ΤΕΧΝΟΛΟΓΙΚΏΝ ΕΦΑΡΜΟΓΏΝ ΤΜΗΜΑ ΗΛΕΚΤΡΟΛΟΓΩΝ ΜΗΧΑΝΙΚΩΝ Τ.Ε. ΠΤΥΧΙΑΚΗ ΕΡΓΑΣΙΑ CHECK IN TANK PUMPING THROUGH GSM Επιβλέπων Καθηγητής: Κόγιας Παναγιώτης Επιβλέπουσα Καθηγήτρια: Κόγια Φωτεινή ΚΑΒΑΛΑ, ΦΕΒΡΟΥΑΡΙΟΣ
PEH C High CV-value Long Life, > 10 years at 50 C Low ESR and ESL High stability, 10 years shelf life
PEH 169 85 C High CV-value Long Life, > 10 years at 50 C Low ESR and ESL High stability, 10 years shelf life APPLICATION BASIC DESIGN Smoothing, energy storage, or pulse operation in telecommunication
RF series Ultra High Q & Low ESR capacitor series
RF series Ultra High Q & Low ESR capacitor series FAITHFUL LINK Features Application» High Q and low ESR performance at high frequency» Telecommunication products & equipments:» Ultra low capacitance to
BALL VALVE NP - LEVE 754. Range of application: Temperature range: Perform standard: Order information: Paint: Soft seal Ball valve.
Soft seal Ball valve Unilateral spring washer Seat Float ball valve Flange PN16-40 DN15-200 Range of application: In industrial facilities, oil and chemical industry and related manufacturing industries
Technical Specifications
FLX-8X8A Chassis Technical Specifications Modular Input Cards... FLX-BI4, FLX-DI4, FLX-HI4, FLX-RI4 Analog Audio... Balanced or Unbalanced Stereo Audio (20 Hz to 20 khz) Supported Outputs Modular Output
2R2. 2 (L W H) [mm] Wire Wound SMD Power Inductor. Nominal Inductance Packing Tape & Reel. Design Code M ±20%
Wire Wound SMD Power Inductors WPN Series Operating temperature range : -40 ~+125 (Including self-heating) FEATURES Fe base metal material core provides large saturation current Metallization on ferrite
Thyristor & Diode Modules
Thyristor & We offer a broad range of PowerBLOCK modules containing thyristor and diode pellets in a voltage range of 1200V to 4400V and a current range of 61A up to 1070A. The modules are designed and
Δθαξκνγέο αζύξκαηεο ηειεκεηξίαο ζηελ αλαπηπμηαθή πιαηθόξκα Arduino
Σερλνινγηθό Δθπαηδεπηηθό Ίδξπκα Κξήηεο ρνιή Σερλνινγηθώλ Δθαξκνγώλ Σκήκα Δθαξκνζκέλεο Πιεξνθνξηθήο & Πνιπκέζσλ Πηπρηαθή εξγαζία Δθαξκνγέο αζύξκαηεο ηειεκεηξίαο ζηελ αλαπηπμηαθή πιαηθόξκα Arduino Διεπζεξηάδεο
Ημερομηνία Τελευταίας Ενημέρωσης: Μαϊος 2017
DegerHellas Μον.ΕΠΕ Ενεργειακά Συστήματα, Μεγάλου Αλεξάνδρου 169, 13562,Αγιοι Ανάργυροι, Αθήνα Τ: 211-0127290 F: 211-0127293, E: info-greece@degerenergie.com Θέμα: Κείμενο Εγγυήσεων DegerTrackers Ημερομηνία
DC-DC Constant Current Step-Down LED driver LDD-300L LDD-350L LDD-500L LDD-600L LDD-700L CURRENT RANGE
SPECIFICATION ORDER NO. LDD-00L LDD-0L LDD-00L LDD-00L LDD-700L CURRENT RANGE 00mA 0mA 00mA VOLTAGE RANGE Note. ~ VDC for LDD-00~700L/LW ; ~ 8VDC for LDD-00~700LS CURRENT ACCURACY (Typ.) ±% at VDC input
Single-channel Safety Barriers Series 9001
Technical Data Certificates Explosion protection Europe (CENELEC) PTB 01 ATEX 2088 PTB 01 ATEX 2135 (Installation in Zone 2) USA FM Approval 3011002 UL Approval E81680 Canada CSA 1284547 (LR 43394) Russia
ίκτυο προστασίας για τα Ελληνικά αγροτικά και οικόσιτα ζώα on.net e-foundatio //www.save itute: http:/ toring Insti SAVE-Monit
How to run a Herdbook: Basics and Basics According to the pedigree scheme, you need to write down the ancestors of your animals. Breeders should be able easily to write down the necessary data It is better
Metal thin film chip resistor networks
Metal thin film chip resistor networks AEC-Q200 Compliant Features Relative resistance and relative TCR definable among multiple resistors within package. Relative resistance : ±%, relative TCR: ±1ppm/
QUICKTRONIC PROFESSIONAL QTP5
osram.com QUICKTRONIC PROFESSIONA QTP5 ECG for T5/ 16mm, T8/ 26mm, DUUX fluorescent lamps QTP5 i.e. UMIUX T5 HO ES 01 Product Features: Up to 100.000 hours lifetime 1 amp start with optimized filament
PS500 Rotatable Programmable Pressure Sensors
PS500 Rotatable Programmable Pressure Sensors Great for Hydraulic & Pneumatic Application IP67 Dual Switch points Part Number Operating Range Overpressure Rating Set Reset Fluid Connection Drawing # Bar
Lowara SPECIFICATIONS
SH Series Centrifugal pumps entirely made of AISI 36 stainless steel according to EN 733 (ex DIN 24255). Designed to pump hot, cold and moderately aggressive liquids. Available versions: SHE Close-coupled
Instruction Execution Times
1 C Execution Times InThisAppendix... Introduction DL330 Execution Times DL330P Execution Times DL340 Execution Times C-2 Execution Times Introduction Data Registers This appendix contains several tables
Mean bond enthalpy Standard enthalpy of formation Bond N H N N N N H O O O
Q1. (a) Explain the meaning of the terms mean bond enthalpy and standard enthalpy of formation. Mean bond enthalpy... Standard enthalpy of formation... (5) (b) Some mean bond enthalpies are given below.
DLG Series. Lowara SPECIFICATIONS APPLICATIONS ACCESSORIES MATERIALS. General Catalogue
DLG Series Submersible pumps with open impeller with grinder assembly for pumping sewage, liquids, wastewater in general and industrial sludge, draining of flooded excavations. SPECIFICATIONS Delivery:
Strain gauge and rosettes
Strain gauge and rosettes Introduction A strain gauge is a device which is used to measure strain (deformation) on an object subjected to forces. Strain can be measured using various types of devices classified
HORIZONTAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS in AISI 304
Horizontal multistage centrifugal electric pumps stainless steel. APPLICATIONS Industrial washing Pressure boosting units Industrial plants Distribution and treatment of water Heating and air conditioning
Potential Dividers. 46 minutes. 46 marks. Page 1 of 11
Potential Dividers 46 minutes 46 marks Page 1 of 11 Q1. In the circuit shown in the figure below, the battery, of negligible internal resistance, has an emf of 30 V. The pd across the lamp is 6.0 V and
ASL BS ,00 ASL BS ,00 ASL BS ,80 ASL BS ,60 ASL TP SET 1 817,20 ASL TP SET 2 997,20 ASL TP SET ,20
www.asl-inter.com BASIC SERIES ASL BS 217 Κεντρική μονάδα intercom 2 καναλιών. Κάθε κανάλι διαθέτει φωτιζόμενο κουμπί Talk και Call και volume για τον έλεγχο της έντασης. Στην πίσω πλευρά διαθέτει μια
C4C-C4H-C4G-C4M MKP Series AXIAL CAPACITORS PCB APPLICATIONS
C4C-C4H-C4G-C4M AXIAL CAPACITORS PCB APPLICATIONS General characteristics - Self-Healing - Low losses - High ripple current - High contact reliability - Suitable for high frequency applications 40 ±5 L
555 TIMER APPLICATIONS AND VOLTAGE REGULATORS
555 TIMER APPLICATIONS AND VOLTAGE REGULATORS OBJECTIVE The purpose of the experiment is to design and experimentally verify astable and monostable multivibrators using 555 timers; to design variable voltage
High Frequency Chip Inductor / CF TYPE
High Frequency Chip Inductor / CF TYPE.Features: 1.Closed magnetic circuit avoids crosstalk. 2.S.M.T. type. 3.Excellent solderability and heat resistance. 4.High realiability. 5.The products contain no
SPARE PARTS LIST. for. Infrared oil heater. Model. Daystar. Type. PH5 for 120V 60Hz. May, 2017
SPARE PARTS LIST for Infrared oil heater Model Daystar Type PH5 for 120V 60Hz May, 2017 *PRICES AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE..* 2017 J.S.O'will, Inc.. Shizuoka Seiki Co. Ltd.
ΠΟΡΤΕΣ ΑΝΑΚΑΙΝΙΣΗΣ DOORS FOR MODERNIZATION
ΠΟΡΤΕΣ ΑΝΑΚΑΙΝΙΣΗΣ DOORS FOR MODERNIZATION ΠΟΡΤΑ ΟΡΟΦΟΥ ΚΕΝΤΡΙΚΗ 2ΦΥΛΛΗ 2 PANELS CENTRE PARTING LANDING DOOR.1. Πόρτα ορόφου χωρίς κάσωμα, για ανακαινίσεις Landing door without frames, for modernization
Dynamic types, Lambda calculus machines Section and Practice Problems Apr 21 22, 2016
Harvard School of Engineering and Applied Sciences CS 152: Programming Languages Dynamic types, Lambda calculus machines Apr 21 22, 2016 1 Dynamic types and contracts (a) To make sure you understand the
HOTEL TECH CONFERENCE 2018
HOTEL TECH CONFERENCE 2018 Presentation 08.02.2018 Ολοκληρωμένες Λύσεις Εξοικονόμησης Ενέργειας, από τη Θεωρία στην Πράξη Energy Efficiency: What is it? KEY FIGURE 100 units 35 units 33 units Fossil Fuels
± 20% ± 5% ± 10% RENCO ELECTRONICS, INC.
RL15 RL16, RL17, RL18 MINIINDUCTORS CONFORMALLY COATED MARKING The nominal inductance is marked by a color code as listed in the table below. Color Black Brown Red Orange Yellow Green Blue Purple Grey
DC-DC Constant Current Step-Down LED driver LDD-300L LDD-350L LDD-500L LDD-600L LDD-700L CURRENT RANGE
SPECIFICATION ORDER NO. LDD-00L LDD-0L LDD-00L LDD-00L LDD-700L CURRENT RANGE 00mA 0mA 00mA 00mA VOLTAGE RANGE Note. ~ VDC for LDD-00~700L/LW ; ~ 8VDC for LDD-00~700LS CURRENT ACCURACY (Typ.) ±% at VDC
EE512: Error Control Coding
EE512: Error Control Coding Solution for Assignment on Finite Fields February 16, 2007 1. (a) Addition and Multiplication tables for GF (5) and GF (7) are shown in Tables 1 and 2. + 0 1 2 3 4 0 0 1 2 3
ΠΡΟΣΚΛΗΣΗ ΕΝΔΙΑΦΕΡΟΝΤΟΣ KAI ΚΑΤΑΘΕΣΗΣ ΠΡΟΣΦΟΡΩΝ ΓΙΑ ΤΗΝ ΑΝΑΘΕΣΗ ΤΗΣ ΠΡΟΜΗΘΕΙΑΣ
ΕΘΝΙΚΟ ΚΕΝΤΡΟ ΕΡΕΥΝΑΣ ΚΑΙ ΤΕΧΝΟΛΟΓΙΚΗΣ ΑΝΑΠΤΥΞΗΣ (Ε.Κ.Ε.Τ.Α.) / Ινστιτούτο Χημικών Διεργασιών και Ενεργειακών Πόρων (ΙΔΕΠ) Θεσσαλονίκη, 17-12-2018 Αριθμ. Πρωτ.: 000603 ΠΡΟΣΚΛΗΣΗ ΕΝΔΙΑΦΕΡΟΝΤΟΣ KAI ΚΑΤΑΘΕΣΗΣ
ΗΜΥ 210 ΣΧΕΔΙΑΣΜΟΣ ΨΗΦΙΑΚΩΝ ΣΥΣΤΗΜΑΤΩΝ. Χειµερινό Εξάµηνο 2016 ΔΙΑΛΕΞΗ 18: Διαδικασία Σχεδίασης Ψηφιακών Συστηµάτων - Επανάληψη
ΗΜΥ 210 ΣΧΕΔΙΑΣΜΟΣ ΨΗΦΙΑΚΩΝ ΣΥΣΤΗΜΑΤΩΝ Χειµερινό Εξάµηνο 2016 ΔΙΑΛΕΞΗ 18: Διαδικασία Σχεδίασης Ψηφιακών Συστηµάτων - Επανάληψη ΧΑΡΗΣ ΘΕΟΧΑΡΙΔΗΣ Επίκουρος Καθηγητής, ΗΜΜΥ (ttheocharides@ucy.ac.cy) Περίληψη
ΕΝΤΥΠΟ 1 Τεχνικές Προδιαγραφές
ΕΝΤΥΠΟ 1 Τεχνικές Προδιαγραφές Το παρόν έγγραφο παρουσιάζει τα τεχνικά χαρακτηριστικά των Φορητών Αισθητήρων Μέτρησης της Ποιότητας του Αέρα (IOT Wireless Nodes) που απαιτούνται για το έργο AIRTHINGS.
Solar Laptop Charger with 2.5w/12000mah
WWW..GR ΕΤΑΙΡΙΑ: ΟΙ. ΦΟΡΤΙΣΤΕΣ ΜΑΣ ΓΙΑ ΟΛΑ ΚΑΙ ΟΛΟΥΣ Solar Laptop Charger with 2.5w/12000mah Specification Battery Type: Lithium-ion polymer battery; Battery capacity: 12000mAh/3.7V 3000mAh lithium polymer
Matrix2000. Οδηγίες Χρήστη - CPD Προηγμένος Συμβατικός Πίνακας Πυρανίχνευσης 4 24 Ζώνες. Version: 2.0 Revision: 1
Matrix2000 Οδηγίες Χρήστη - CPD Προηγμένος Συμβατικός Πίνακας Πυρανίχνευσης 4 24 Ζώνες Version: 2.0 Revision: 1 ΠΕΡΙΕΧΟΜΕΝΑ 1. Γενική περιγραφή 4 2. Ενδείξεις και Χειρισμοί Πληκτρολογίου 4 2.1 Ένδειξη
Finish: Anticorrosive finish in polyester. Number of motor poles 4=1400 r/min. 50 Hz 6=900 r/min. 50 Hz 8=750 r/min. 50 Hz
HEP HEPT HEP: Wall-mounted axial fans, with IP65 motor HEPT: Long-cased axial fans, with IP65 motor Wall-mounted axial (HEP) and long-cased (HEPT) fans, with fibreglass-reinforced plastic impeller. Fan:
FP series Anti-Bend (Soft termination) capacitor series
FP series Anti-Bend (Soft termination) capacitor series Features Applications» High performance to withstanding 5mm of substrate» For general digital circuit bending test guarantee» For power supply bypass
ΔΙΠΛΩΜΑΤΙΚΗ ΕΡΓΑΣΙΑ. του φοιτητή του Τμήματος Ηλεκτρολόγων Μηχανικών και. Τεχνολογίας Υπολογιστών της Πολυτεχνικής Σχολής του. Πανεπιστημίου Πατρών
ΠΑΝΕΠΙΣΤΗΜΙΟ ΠΑΤΡΩΝ ΤΜΗΜΑ ΗΛΕΚΤΡΟΛΟΓΩΝ ΜΗΧΑΝΙΚΩΝ ΚΑΙ ΤΕΧΝΟΛΟΓΙΑΣ ΥΠΟΛΟΓΙΣΤΩΝ ΤΟΜΕΑΣ ΣΥΣΤΗΜΑΤΩΝ ΗΛΕΚΤΡΙΚΗΣ ΕΝΕΡΓΕΙΑΣ ΕΡΓΑΣΤΗΡΙΟ ΗΛΕΚΤΡΟΜΗΧΑΝΙΚΗΣ ΜΕΤΑΤΡΟΠΗΣ ΕΝΕΡΓΕΙΑΣ ΔΙΠΛΩΜΑΤΙΚΗ ΕΡΓΑΣΙΑ του φοιτητή του
Heat exchanger. Type WT. For the reheating of airflows in rectangular ducting PD WT 1. 03/2017 DE/en
X X testregistrierung Heat exchanger Type For the reheating of airflows in rectangular ducting Rectangular hot water heat exchanger for the reheating of airflows, suitable for VAV terminal units Type TVR,
ELWOOD HIGH PERFORMANCE MOTORS H-SERIES MOTOR DATA
H-SERIES MOTOR DATA MOTOR MODEL H-3007 H-3016 H-4030-P H-4030-M H-4040 H-4050 H-4075 H-6100 H-6200 H-6300 MECHANICAL DATA (1) Rated Torque, Cont (Stall) 0.8 2.3 3.4 3.4 5.0 6.8 10.2 11.3 22.6 36.7 lb-in