Bauar t gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 000000000 Ⅰ Ⅱ Standby 5V@A with fan, 0.6A without fan Built-in remote sense function Ⅰ Ⅱ
SPECIFICATION MODEL OUTPUT INPUT DC VOLTAGE CURRENT RATED POWER 5CFM Convection 5CFM LINE REGULATION Convection RIPPLE NOISE (max.) Note. VOLTAGE ADJ. RANGE(MAIN OUTPUT).4~.6V 4.3~5.8V 7.~8.9V.8~5.V 5.6 ~ 8.4V 34. ~37.8V VOLTAGE TOLERANCE LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR EFFICIENCY (Typ.) AC CURRENT (Typ.) Note.4 INRUSH CURRENT (Typ.) LEAKAGE CURRENT Note.3 EPP-400- V 33.3A 0.8A 399.6W 0mVp-p ±3.0% ±3.0% ±3.0% ±.0% 000ms, 30ms/30VAC 6ms/30VAC 500ms, 30ms/5VAC at full load ms/5vac at full load 80 ~ 64VAC 3 ~ 370VDC 47 ~ 63Hz PF>0.94/30VAC PF>0.98/5VAC at full load 9.5% 4.A/5VAC 9%.A/30VAC COLD START 40A/5VAC 5V 8V 4V 7V 36V 6.7A 6.7A 400.5W 49.6W 50.5W <0.75mA / 40VAC EPP-400-5 EPP-400-8 EPP-400-4 EPP-400-7 EPP-400-36 EPP-400-48.3A 3.9A 40.4W 50.W 50mVp-p 80mVp-p 00mVp-p 00mVp-p 50mVp-p 9% 80A/30VAC 6.7A 0.5A 400.8W 5W 93% 4.9A 9.3A 40.3W 5.W.A 7A 403.W 5W 93.5% 93% 48V 8.4A 5.3A 403.W 54.4W 50mVp-p 45.6 ~50.4V 94% OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE 5V STANDBY FAN SUPPLY FUNCTION PS-ON INPUT SIGNAL POWER GOOD / POWER FAIL WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION OPERATING ALTITUDE Note.5 05 ~ 35% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 3. ~ 5.6V 6.5 ~ 9.5V 6.5 ~ 9.5V 6.4 ~ 3.V 9.7 ~ 35.V 39.6 ~ 46.8V Protection type : Shut down o/p voltage, re-power on to recover Protection type : Shut down o/p voltage, recovers automatically after temperature goes down 5VSB : 5V@0.6A without fan, A with fan 5CFM ; tolerance ±%, ripple : 0mVp-p(max.) V@0.5A for driving a fan ; tolerance ±0% Power on: PS-ON = "Hi" or " > ~ 5V" ; Power off: PS-ON = "Low" or " < 0 ~ 0.5V" 500ms>>0ms ; The TTL signal goes high with 0ms to 500ms delay after power set up ; The TTL signal goes low at least ms before Vo below 90% of rated value -30 ~ +70 (Refer to "Derating Curve") 0 ~ 90% RH non-condensing -40 ~ +85, 0 ~ 95% RH ±0.03%/ (0 ~ 50 ) 0 ~ 500Hz, G 0min./cycle, 60min. each along X, Y, Z axes 5000 meters 5.8 ~ 6.4V
SAFETY EMC (Note 6) OTHERS SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF DIMENSION PACKING UL60950-, TUV EN60950-, IEC60950- approved I/P-O/P:3KVAC I/P-FG:KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG:00M Ohms / 500VDC / 5 / 70% RH Parameter Standard Conducted EN550 (CISPR) Radiated EN550 (CISPR) Harmonic Current EN6000-3- Voltage Flicker EN6000-3-3 EN5504, EN6060-- Parameter Standard ESD EN6000-4- Radiated EN6000-4-3 EFT / Burst EN6000-4-4 Surge EN6000-4-5 Conducted EN6000-4-6 Magnetic Field EN6000-4-8 Voltage Dips and Interruptions EN6000-4- 94.Khrs min. MIL-HDBK-7F (5 ) 7*76.*35mm (L*W*H) 0.39Kg; 36pcs/5Kg/.03CUFT Test Level / Note Class B Class B Class A ----- Test Level / Note Level 4, 5KV air ; Level 4, 8KV contact, KV/Line-FG ; KV/Line-Line Level 4 00% dip periods, 30% dip 5 periods, 00% interruptions 50 periods NOTE ClassⅠ ClassⅡ
Block Diagram PFC fosc : 90KHz PWM fosc : 00KHz I/P EMI PFC POWER SWITCHING PWM CONTROL POWER SWITCHING +5VSB DETECTION CIRCUIT +5VSB +V FAN SUPPLY +S -S FG O.L.P. CONTROL DETECTION CIRCUIT O.V.P. PS/ON CONTROL PS-ON Derating Curve Output Derating VS Input Voltage 400 With 5CFM fan 00 90 50 80 5VAC Converction 70 LOAD (W) 90 60 30 30VAC Converction LOAD (%) 60 50 40-30 0 0 0 30 40 50 60 70 AMBIENT TEMPERATURE ( ) (HORIZONTAL) 80 90 00 5 0 40 60 80 00 0 40 64 INPUT VOLTAGE (VAC) 60Hz
Mechanical Specification Unit:mm 7 5.6 5.8 76. 5.7 64.8 3 CN ACL ACN F8A 50V FS HS HS HS3 HS4 SVR 43 CN CN CN95 4 3 FG 4-ψ3.5 5cm Air flow direction FAN 5CFM 3 max. 35 AC Input Connector (CN) : JST B3PH AC/N No Pin JST VHR JST SVH-T-P. 3 AC/L DC Output Connector (CN,CN3) Pin No. CN CN3 Assignment Output Terminals M4 Pan HD screw in positions Torque to 8 lbs-in(90cnm)max. Function Connector(CN): TKP DHI-X -S 3 4 +S DC COM TKP DH TKP Function Connector(CN95): TKP DHL-X 5VSB TKP DH TKP,4 DC COM 3 PS-ON FAN Connector(CN) : TKP 88- Pin No. Assignment DC COM +V Mating Housing TKP 50 Terminal TKP 88 Note: When the input voltage is 30VAC the model delivers EMI Class B for both conducted emission and radiated emission for the power supply, When the input voltage is AC0VAC the model delivers EMI Class B for conducted emission and Class A for radiated emission for the power supply. It delivers Class A for conduted emission and radiated emission, when configured into ClassⅡ (without FG) system. Installation Manual Please refer to : http://www.meanwell.com/manual.html