Bauar t gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 000000000 Ⅰ Ⅱ Standby 5V@A with fan, 0.6A without fan Built-in remote sense function Ⅰ Ⅱ File Name:EPP-400-SPEC 07-08-
SPECIFICATION MODEL OUTPUT INPUT DC VOLTAGE CURRENT RATED POWER 5CFM Convection 5CFM LINE REGULATION Convection VOLTAGE ADJ. RANGE(MAIN OUTPUT).4~.6V 4.3~5.8V.8~5.V 5.6 ~ 8.4V 34. ~37.8V LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE Note.4 FREQUENCY RANGE POWER FACTOR EFFICIENCY (Typ.) INRUSH CURRENT (Typ.) OVER TEMPERATURE 5V STANDBY FAN SUPPLY FUNCTION PS-ON INPUT SIGNAL POWER GOOD / POWER FAIL WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 0 ~ 95% RH OTHERS NOTE AC CURRENT (Typ.) OVERLOAD PROTECTION OVER VOLTAGE SAFETY EMC (Note 5) RIPPLE NOISE (max.) Note. 0mVp-p VOLTAGE TOLERANCE Note.3 ±3.0% ±3.0% ±.0% LEAKAGE CURRENT TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF DIMENSION PACKING EPP-400- V 33.3A 0.8A 399.6W 000ms, 30ms/30VAC 6ms/30VAC 500ms, 30ms/5VAC at full load ms/5vac at full load 80 ~ 64VAC 3 ~ 370VDC 47 ~ 63Hz PF>0.94/30VAC PF>0.98/5VAC at full load 9.5% 4.A/5VAC 9%.A/30VAC COLD START 40A/5VAC 05 ~ 35% rated output power 3. ~ 5.6V 6.5 ~ 9.5V 80A/30VAC 93.5% 93% Protection type : Hiccup mode, recovers automatically after fault condition is removed -30 ~ +70 (Refer to "Derating Curve") 0 ~ 90% RH non-condensing 9.7 ~ 35.V 39.6 ~ 46.8V 5VSB : 5V@0.6A without fan, A with fan 5CFM ; tolerance ±%, ripple : 0mVp-p(max.) V@0.5A for driving a fan ; tolerance ±0% Power on: PS-ON = "Hi" or " > ~ 5V" ; Power off: PS-ON = "Low" or " < 0 ~ 0.5V" 500ms>>0ms ; The TTL signal goes high with 0ms to 500ms delay after power set up ; The TTL signal goes low at least ms before Vo below 90% of rated value ±0.03%/ (0 ~ 50 ) 0 ~ 500Hz, G 0min./cycle, 60min. each along X, Y, Z axes 94.Khrs min. MIL-HDBK-7F (5 ) 7*76.*35mm (L*W*H) 0.39Kg; 36pcs/5Kg/.03CUFT 5V 4V 7V 36V 6.7A 6.7A 400.5W 49.6W 50.5W <0.75mA / 40VAC EPP-400-5 EPP-400-4 EPP-400-7 EPP-400-36 EPP-400-48 6.7A 0.5A 400.8W 5W 4.9A 9.3A 40.3W 5.W.A 50mVp-p 00mVp-p 00mVp-p 50mVp-p 93% 6.4 ~ 3.V Protection type : Shut down o/p voltage, re-power on to recover 7A 403.W 5W Protection type : Shut down o/p voltage, recovers automatically after temperature goes down UL60950-, TUV EN60950-, IEC60950- approved I/P-O/P:3KVAC I/P-FG:KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG:00M Ohms / 500VDC / 5 / 70% RH Compliance to EN5503 (CISPR3) Class B, EN6000-3-,-3 48V 8.4A 5.3A 403.W 54.4W 50mVp-p 45.6 ~50.4V Compliance to EN6000-4-,3,4,5,6,8,, EN5504, EN6000-6-, heavy industry level, criteria A 94% 5.8 ~ 6.4V ClassⅠ ClassⅡ File Name:EPP-400-SPEC 07-08-
Block Diagram I/P EMI PFC POWER SWITCHING PWM CONTROL POWER SWITCHING +5VSB DETECTION CIRCUIT +5VSB -S PFC fosc : 90KHz PWM fosc : 00KHz FAN SUPPLY +S FG O.L.P. CONTROL DETECTION CIRCUIT O.V.P. PS/ON CONTROL PS-ON Derating Curve Output Derating VS Input Voltage 400 With 5CFM Fan 00 90 50 80 EPP-400:5VAC Converction 70 LOAD (W) 90 60 30 EPP-400:30VAC Converction LOAD (%) 60 50 40-30 0 0 0 30 40 50 60 70 AMBIENT TEMPERATURE ( ) (HORIZONTAL) 80 90 00 5 0 40 60 80 00 0 40 64 INPUT VOLTAGE (VAC) 60Hz Without Fan Watt With Fan Watt 50W 400W File Name:EPP-400-SPEC 07-08-
Mechanical Specification Unit:mm 7 5.6 5.8 76. 5.7 64.8 3 CN ACL ACN F8A 50V FS HS HS HS3 HS4 SVR 43 CN CN CN95 4 3 FG 4-ψ3.5 5cm Air flow direction FAN 5CFM 3 max. 35 AC Input Connector (CN) : JST B3PH AC/N No Pin JST VHR JST SVH-T-P. 3 AC/L Function Connector(CN95): TKP DHL-X 5VSB TKP DH TKP,4 DC COM 3 PS-ON FAN Connector(CN) : TKP 88- Pin No. Assignment DC COM Mating Housing TKP 50 Terminal TKP 88 DC Output Connector (CN,CN3) Pin No. CN CN3 Assignment Output Terminals M3.5 Pan HD screw in positions Torque to 8 lbs-in(90cnm)max. Function Connector(CN): TKP DHI-X -S 3 4 +S DC COM TKP DH TKP Note: When the input voltage is AC 30V the model delivers EMI Class B for both conducted emission and radiated emission for the power supply, When the input voltage is AC0V the model delivers EMI Class B for conducted emission,class A for radiated emission for the power supply. It delivers Class A for conduted emission and radiated emission, when configured into ClassⅡ (without FG) system. Installation Manual Please refer to : http://www.meanwell.com/webnet/search/installationsearch.html File Name:EPP-400-SPEC 07-08-
Sager Electronics and its specialized group Sager Power Systems is an authorized distributor of MEAN WELL and the EPP-400 Series of power supplies. Visit the EPP series online. Or contact a Sager Power Systems representative at.866.588.750 or power@sager.com for price and availability. Sager Power Systems, the authorized distributor for MEAN WELL