Example Building. The following example illustrates the



Σχετικά έγγραφα
APPENDIX 1: Gravity Load Calculations. SELF WEIGHT: Slab: 150psf * 8 thick slab / 12 per foot = 100psf ROOF LIVE LOAD:

D28 1-1/4" PIPE x 42-1/2" HIGH RAIL WITHOUT BOTTOM RAIL

5.0 DESIGN CALCULATIONS

CHAPTER 25 SOLVING EQUATIONS BY ITERATIVE METHODS

STRUCTURAL CALCULATIONS FOR SUSPENDED BUS SYSTEM SEISMIC SUPPORTS SEISMIC SUPPORT GUIDELINES

Math 6 SL Probability Distributions Practice Test Mark Scheme

Chapter 7 Transformations of Stress and Strain

Technical Data for Profiles. α ( C) = 250 N/mm 2 (36,000 lb./in. 2 ) = 200 N/mm 2 (29,000 lb./in 2 ) A 5 = 10% A 10 = 8%

Thin Film Chip Resistors

DISCLAIMER By using the LOGIX Design Manual, in part or in whole, the user accepts the following terms and conditions.

HSS Hollow. Structural Sections LRFD COLUMN LOAD TABLES HSS: TECHNICAL BROCHURE

Homework 3 Solutions

Ingenieurbüro Frank Blasek - Beratender Ingenieur Am Kohlhof 10, Osterholz-Scharmbeck Tel: 04791/ Fax: 04791/

Ingenieurbüro Frank Blasek - Beratender Ingenieur Am Kohlhof 10, Osterholz-Scharmbeck Tel: 04791/ Fax: 04791/

ΚΥΠΡΙΑΚΗ ΕΤΑΙΡΕΙΑ ΠΛΗΡΟΦΟΡΙΚΗΣ CYPRUS COMPUTER SOCIETY ΠΑΓΚΥΠΡΙΟΣ ΜΑΘΗΤΙΚΟΣ ΔΙΑΓΩΝΙΣΜΟΣ ΠΛΗΡΟΦΟΡΙΚΗΣ 19/5/2007

Surface Mount Multilayer Chip Capacitors for Commodity Solutions

The Simply Typed Lambda Calculus

MS SERIES MS DESK TOP ENCLOSURE APPLICATION EXAMPLE FEATURE. Measuring instruments. Power supply equipments

Areas and Lengths in Polar Coordinates

ANSWERSHEET (TOPIC = DIFFERENTIAL CALCULUS) COLLECTION #2. h 0 h h 0 h h 0 ( ) g k = g 0 + g 1 + g g 2009 =?

Structural Design of Raft Foundation

Areas and Lengths in Polar Coordinates

Full Beam Design Example

UDZ Swirl diffuser. Product facts. Quick-selection. Swirl diffuser UDZ. Product code example:

Other Test Constructions: Likelihood Ratio & Bayes Tests

Analyse af skrå bjælke som UPE200

C.S. 430 Assignment 6, Sample Solutions

MasterSeries MasterPort Lite Sample Output

MSN DESK TOP ENCLOSURE WITH STAND / CARRYING HANDLE

[1] P Q. Fig. 3.1

Approximation of distance between locations on earth given by latitude and longitude

ΕΙΣΑΓΩΓΗ ΣΤΗ ΣΤΑΤΙΣΤΙΚΗ ΑΝΑΛΥΣΗ

DuPont Suva 95 Refrigerant

2 Composition. Invertible Mappings

moment ENGINEERING + DESIGN Warwick Ave, Suite C5 Fairfax, VA Phone: Web: February 20, 2015

Strain gauge and rosettes

5.4 The Poisson Distribution.

Technical Information T-9100 SI. Suva. refrigerants. Thermodynamic Properties of. Suva Refrigerant [R-410A (50/50)]

MECHANICAL PROPERTIES OF MATERIALS

Inverse trigonometric functions & General Solution of Trigonometric Equations

Second Order RLC Filters

ΕΛΕΓΧΟΣ ΤΩΝ ΠΑΡΑΜΟΡΦΩΣΕΩΝ ΧΑΛΥΒ ΙΝΩΝ ΦΟΡΕΩΝ ΜΕΓΑΛΟΥ ΑΝΟΙΓΜΑΤΟΣ ΤΥΠΟΥ MBSN ΜΕ ΤΗ ΧΡΗΣΗ ΚΑΛΩ ΙΩΝ: ΠΡΟΤΑΣΗ ΕΦΑΡΜΟΓΗΣ ΣΕ ΑΝΟΙΚΤΟ ΣΤΕΓΑΣΤΡΟ

Bulletin 1489 UL489 Circuit Breakers

HOMEWORK 4 = G. In order to plot the stress versus the stretch we define a normalized stretch:

Homework 8 Model Solution Section

ΚΥΠΡΙΑΚΗ ΕΤΑΙΡΕΙΑ ΠΛΗΡΟΦΟΡΙΚΗΣ CYPRUS COMPUTER SOCIETY ΠΑΓΚΥΠΡΙΟΣ ΜΑΘΗΤΙΚΟΣ ΔΙΑΓΩΝΙΣΜΟΣ ΠΛΗΡΟΦΟΡΙΚΗΣ 6/5/2006

the total number of electrons passing through the lamp.

Cross sectional area, square inches or square millimeters

Εργαστήριο Ανάπτυξης Εφαρμογών Βάσεων Δεδομένων. Εξάμηνο 7 ο

CHAPTER 12: PERIMETER, AREA, CIRCUMFERENCE, AND 12.1 INTRODUCTION TO GEOMETRIC 12.2 PERIMETER: SQUARES, RECTANGLES,

CHAPTER 48 APPLICATIONS OF MATRICES AND DETERMINANTS

Struct4u b.v. Calculation number : Revision : 0 Page 1 of 8 Project number : Date - time : :25 Project description : Part :

DuPont Suva. DuPont. Thermodynamic Properties of. Refrigerant (R-410A) Technical Information. refrigerants T-410A ENG

Περίπτωση Μελέτης Θαλάσσιας Κατασκευής με χρήση λογισμικού και με βάση Κώδικες (Compliant Tower) (8.1.10)

ΚΥΠΡΙΑΚΗ ΕΤΑΙΡΕΙΑ ΠΛΗΡΟΦΟΡΙΚΗΣ CYPRUS COMPUTER SOCIETY ΠΑΓΚΥΠΡΙΟΣ ΜΑΘΗΤΙΚΟΣ ΔΙΑΓΩΝΙΣΜΟΣ ΠΛΗΡΟΦΟΡΙΚΗΣ 24/3/2007

DuPont Suva 95 Refrigerant

k A = [k, k]( )[a 1, a 2 ] = [ka 1,ka 2 ] 4For the division of two intervals of confidence in R +

( ) 2 and compare to M.

COMPOSITE SLABS DESIGN CONTENTS

Design of Self supporting Steel Chimney for

Aluminum Electrolytic Capacitors (Large Can Type)

TMA4115 Matematikk 3

Phys460.nb Solution for the t-dependent Schrodinger s equation How did we find the solution? (not required)

Main source: "Discrete-time systems and computer control" by Α. ΣΚΟΔΡΑΣ ΨΗΦΙΑΚΟΣ ΕΛΕΓΧΟΣ ΔΙΑΛΕΞΗ 4 ΔΙΑΦΑΝΕΙΑ 1

Assalamu `alaikum wr. wb.

Macromechanics of a Laminate. Textbook: Mechanics of Composite Materials Author: Autar Kaw

ΤΕΧΝΟΛΟΓΙΚΟ ΠΑΝΕΠΙΣΤΗΜΙΟ ΚΥΠΡΟΥ ΣΧΟΛΗ ΓΕΩΠΟΝΙΚΩΝ ΕΠΙΣΤΗΜΩΝ ΒΙΟΤΕΧΝΟΛΟΓΙΑΣ ΚΑΙ ΕΠΙΣΤΗΜΗΣ ΤΡΟΦΙΜΩΝ. Πτυχιακή εργασία

CONSULTING Engineering Calculation Sheet

Aluminum Electrolytic Capacitors

Precision Metal Film Fixed Resistor Axial Leaded

Section 7.6 Double and Half Angle Formulas

Advanced Subsidiary Unit 1: Understanding and Written Response

EE512: Error Control Coding

3.4 MI Components, Allowable Load Data and Specifications. MI Girder 90/120. Material Specifications. Ordering Information

1000 VDC 1250 VDC 125 VAC 250 VAC J K 125 VAC, 250 VAC

Calculating the propagation delay of coaxial cable

Dynamic types, Lambda calculus machines Section and Practice Problems Apr 21 22, 2016

Instruction Execution Times

A, B. Before installation of the foam parts (A,B,C,D) into the chambers we put silicone around. We insert the foam parts in depth shown on diagram.

20/01/ of 8 TOW SSD v3. C 2.78AC Σ Cumul. A*C. Tc 1 =A14+1 =B14+1 =C14+1 =D14+1 =E14+1 =F14+1 =G14+1 =H14+1 =I14+1 =J14+1 =K14+1

ST5224: Advanced Statistical Theory II

Problem Set 3: Solutions

Weight [lb] = (Do-t)*π*L*t*40.84/ (60-1)*3.1416*100*1*40.84/144 = (20000*1*1)/(29+0.6*1) = Pipe and Shell ver 4.

ΚΥΠΡΙΑΚΗ ΕΤΑΙΡΕΙΑ ΠΛΗΡΟΦΟΡΙΚΗΣ CYPRUS COMPUTER SOCIETY ΠΑΓΚΥΠΡΙΟΣ ΜΑΘΗΤΙΚΟΣ ΔΙΑΓΩΝΙΣΜΟΣ ΠΛΗΡΟΦΟΡΙΚΗΣ 11/3/2006

Thin Film Chip Resistors

Smaller. 6.3 to 100 After 1 minute's application of rated voltage at 20 C, leakage current is. not more than 0.03CV or 4 (µa), whichever is greater.

Consolidated Drained

TRIAXIAL TEST, CORPS OF ENGINEERS FORMAT

derivation of the Laplacian from rectangular to spherical coordinates

Right Rear Door. Let's now finish the door hinge saga with the right rear door

SCOPE OF ACCREDITATION TO ISO 17025:2005

Πρόβλημα 1: Αναζήτηση Ελάχιστης/Μέγιστης Τιμής

Data sheet Thick Film Chip Resistor 5% - RS Series 0201/0402/0603/0805/1206

Thick Film Chip Resistors

Visual Systems Division Technical Bulletin MultiSync MT820/MT1020 Installation Data Desk Top and Ceiling Mount

Mock Exam 7. 1 Hong Kong Educational Publishing Company. Section A 1. Reference: HKDSE Math M Q2 (a) (1 + kx) n 1M + 1A = (1) =

EΘΝΙΚΟ ΜΕΤΣΟΒΙΟ ΠΟΛΥΤΕΧΝΕΙΟ ΙΑΓΡΑΜΜΑΤΑ ΡΟΗΣ ΙΑΣΤΑΣΙΟΛΟΓΗΣΗΣ ΣΥΜΜΕΙΚΤΩΝ ΣΤΟΙΧΕΙΩΝ ΒΑΣΕΙ ΤΟΥ EC4 KAI ΣΥΓΚΡΙΣΗ ΜΕ ΤΟΝ LRFD

Stresses in a Plane. Mohr s Circle. Cross Section thru Body. MET 210W Mohr s Circle 1. Some parts experience normal stresses in

Section 8.3 Trigonometric Equations

Appendix to On the stability of a compressible axisymmetric rotating flow in a pipe. By Z. Rusak & J. H. Lee

Transcript:

The following example illustrates the design TIME SAVING methods DESIGN presented AIDS in the article Timesaving Design Aids for Reinforced Concrete, Part 2: Two-way Slabs, by David A. Fanella, which appeared in the October 2001 edition of Structural Engineer magazine. Unless otherwise noted, all referenced table, figure, and equation numbers are from that article. Example Building Page 1 of 14 Below is a partial plan of a typical floor in a cast-in-place reinforced concrete building. In this example, an interior strip of a flat plate floor system is designed and detailed The following example illustrates the design methods presented in the PCA book Simplified Design - Reinforced Concrete Buildings of Moderate Size and Height third edition. Unless otherwise noted, all referenced table, figure, and equation numbers are from that book. for the effects of gravity loads according to ACI 318-99. Example Building Below is a partial plan of a typical floor in a cast-in-place reinforced concrete building. In this example, an interior strip of a flat plate floor system is designed and detailed for the effects of gravity loads according to ACI 318-05. 20-0 20-0 20-0 24-0 Design strip 24-0 20 x 20 (typ.) 24 x 24 (typ.) Design Data Materials Concrete: normal weight (150 pcf), 3 /4-in. maximum aggregate, f c = 4,000 psi Mild reinforcing steel: Grade 60 (f y = 60,000 psi) Loads Superimposed dead loads = 30 psf Live load = 50 psf

TIME SAVING DESIGN AIDS Page 2 of 14 Minimum Slab Thickness Longest clear span l n = 24 (20/12) = 22.33 ft From Fig. 4-3, minimum thickness h per ACI Table 9.5(c) = l n /30 = 8.9 in. Use Fig. 1-8 to determine h based on shear requirements at interior column assuming a 9 in. slab: q u = 1.2(112.5 + 30) + 1.6(50) = 251.0 psf A = 24 x 20 = 480 ft 2 A/c 12 = 480/2 2 = 120 From Fig. 1-8, d/c 1 0.22 d h = 0.22 x 24 = 5.3 in. = 5.3 + 1.25 = 6.55 in. Try preliminary h = 9 in. Design for Flexure Use Fig. 4-4 to determine if the Direct Design Method of ACI Sect. 13.6 can be utilized to compute the bending moments due to the gravity loads: 3 continuous spans in one direction, more than 3 in the other O.K. Rectangular panels with long-to-short span ratio = 24/20 = 1.2 < 2 O.K. Successive span lengths in each direction are equal O.K. No offset columns O.K. L/D = 50/(112.5 + 30) = 0.35 < 2 O.K. Slab system has no beams N.A. Since all requirements are satisfied, the Direct Design Method can be used. Total panel moment M o in end span: 2 2 qull 2 n 0. 251 24 18. 167 M o = = 8 8 = 248.5 ft - kips Total panel moment M o in interior span: 2 2 qull 2 n 0. 251 24 18. 0 M o = = 8 8 = 244 ft - kips For simplicity, use M o = 248.5 ft-kips for all spans. Division of the total panel moment M o into negative and positive moments, and then column and middle strip moments, involves the direct application of the moment coefficients in Table 4-2.

TIME SAVING DESIGN AIDS Page 3 of 14 Slab Moments End Spans Int. Span (ft-kips) Ext. neg. Positive Int. neg. Positive Total Moment 64.6 129.2 173.9 87.0 Column Strip 64.6 77.0 131.7 52.2 Middle Strip 0 52.2 42.2 34.8 Note: All negative moments are at face of support. Required slab reinforcement. M Span Location u b * d ** As Min. As (ft-kips) (in.) (in.) (in. 2 ) (in. 2 ) Reinforcement + End Span Ext. neg. 64.6 120 7.75 2.08 1.94 11-No. 4 Column Positive 77.0 120 7.75 2.48 1.94 13-No. 4 Strip Int. Neg. 131.7 120 7.75 4.25 1.94 22-No. 4 Ext. neg. 0.0 168 7.75 --- 2.72 14-No. 4 Middle Positive 52.2 168 7.75 1.68 2.72 14-No. 4 Strip Int. Neg. 42.2 168 7.75 1.36 2.72 14-No. 4 Interior Span Column Strip Positive 52.2 120 7.75 1.68 1.94 10-No. 4 Middle Strip Positive 34.8 168 7.75 1.12 2.72 14-No. 4 * Column strip width b = (20 x 12)/2 = 120 in. * Middle strip width b = (24 x 12) 120 = 168 in. ** Use average d = 9 1.25 = 7.75 in. A s = M u /4d where M u is in ft-kips and d is in inches Min. A s = 0.0018bh = 0.0162b; Max. s = 2h = 18 in. or 18 in. (Sect. 13.3.2) + For maximum spacing:120/18 = 6.7 spaces, say 8 bars 168/18 = 9.3 spaces, say 11 bars Design for Shear Check slab shear and flexural strength at edge column due to direct shear and unbalanced moment transfer. Check slab reinforcement at exterior column for moment transfer between slab and column. Portion of total unbalanced moment transferred by flexure = γ f M u b 1 = 20 + (7.75/2) = 23.875 in. b 2 = 20 + 7.75 = 27.75 in. b 1 /b 2 = 0.86 From Fig. 4-16, γ f = 0.62 * * The provisions of Sect. 13.5.3.3 may be utilized; however, they are not in this example.

TIME SAVING DESIGN AIDS Page 4 of 14 γ f M u = 0.62 x 64.6 = 40 ft-kips Required A s = 40/(4 x 7.75) = 1.29 in. 2 Number of No. 4 bars = 1.29/0.2 = 6.5, say 7 bars Must provide 7-No. 4 bars within an effective slab width = 3h + c 2 = (3 x 9) + 20 = 47 in. Provide the required 7-No. 4 bars by concentrating 7 of the column strip bars (11-No. 4) within the 47 in. slab width over the column. Check bar spacing: For 7-No. 4 within 47 in. width: 47/7 = 6.7 in. < 18 in. O.K. For 4-No. 4 within 120 47 = 73 in. width: 73/4 = 18.25 in. > 18 in. Add 1 additional bar on each side of the 47 in. strip; the spacing becomes 73/6 = 12.2 in. < 18 in. O.K. Reinforcement details at this location are shown in the figure on the next page. Check the combined shear stress at the inside face of the critical transfer section.

TIME SAVING DESIGN AIDS Page 5 of 14 v u = V A u c vm + γ Jc / u Factored shear force at edge column: V u = 0.251[(24 x 10.83) (1.99 x 2.31)] = 64.1 kips When the end span moments are determined from the Direct Design Method, the fraction of unbalanced moment transferred by eccentricity of shear must be 0.3M o = 0.3 x 248.5 = 74.6 ft-kips (Sect. 13.6.3.6). γ v = 1 γ f = 1 0.62 = 0.38 c 2 /c 1 = 1.0 c 1 /d = 20/7.75 = 2.58 From Table 4.9 A c = (2b 1 + b 2 ) d = 585.1 in. 2 J c = [2b 1 d(b 1 + 2b 2 ) + d 3 (2b 1 + b 2 )/b 1 ]/6 = 5,141 in. 3 v u = 64, 105 0. 38 64. 6 12, 000 + 585.1 5, 141 v u = 109.6 + 57.6 = 167.2 psi Determine allowable shear stress φv c from Fig. 4-13: b o /d = (2b 1 + b 2 )/d b o /d = [(2 x 23.875) + 27.75]/7.75 = 9.74 β c = 1 φv c = 189.7 psi > v u = 168.2 psi OK 9 slab is OK Reinforcement Details The figures below show the reinforcement details for the column and middle strips. The bar lengths are determined from Fig. 13.3.8 of ACI 318-05.

TIME SAVING DESIGN AIDS Page 6 of 14 The PCA computer program pcaslab can be used to expedite the design of different slab systems. The program covers wide range of two-way slab systems and can be used for more complex slab layouts. The output of the program for the slab in the example is shown in the following pages. Please note that the Equivalent Frame Method is used by the pcaslab program.

TIME SAVING DESIGN AID Page 7 of 14 X Z Y pcaslab v2.00. Licensed to: pcastructurepoint. License ID: 12345-1234567-4-2D2DE-2C8D0 File: C:\Data\Time Saving Design Aid\.slb Project: Time Saving Design Aids Frame: Two-Way Slab Engineer: PCA

TIME SAVING DESIGN AID Page 8 of 14 Middle Strip Flexural Reinforcement 10-#4(81.9) 12-#4(83.9) 11-#4(55.6) 16-#4(240.0)c 11-#4(55.2) 12-#4(83.3) 12-#4(83.3) 11-#4(55.2) 10-#4(240.0)c 11-#4(55.6) 12-#4(83.9) 10-#4(81.9) 16-#4(240.0)c 14-#4(73.4) 14-#4(240.0)c 14-#4(82.5) 14-#4(82.5) 14-#4(240.0)c 14-#4(73.4) 14-#4(240.0)c Column Strip Flexural Reinforcement pcaslab v2.00. Licensed to: pcastructurepoint. License ID: 12345-1234567-4-2D2DE-2C8D0 File: C:\Data\Time Saving Design Aid\.slb Project: Time Saving Design Aids Frame: Two-Way Slab Engineer: PCA

TIME SAVING DESIGN AID Page 9 of 14-300.0 Middle Strip Moment Capacity - k-ft 300.0-300.0 Column Strip Moment Capacity - k-ft 300.0 LEGEND: Envelope Curve Capacity Curve Support Centerline Face of Support pcaslab v2.00. Licensed to: pcastructurepoint. License ID: 12345-1234567-4-2D2DE-2C8D0 File: C:\Data\Time Saving Design Aid\.slb Project: Time Saving Design Aids Frame: Two-Way Slab Engineer: PCA

TIME SAVING DESIGN AID Page 10 of 14 pcaslab v2.00 Portland Cement Association 05-03-2007, 11:27:26 AM Licensed to: pcastructurepoint, License ID: 12345-1234567-4-2D2DE-2C8D0 c:\work\time Saving Design Aids\318-05\Rev 2\Data\.slb Page 1 ooooooo oooooo ooooo oooooooo oooooooo ooooooo oo oo oo oo oo oo oo oo oo oo oo oooooooo oo ooooooo ooooo ooooooo oo oo ooooooo ooooo oo oo oo oo oo oo oooooooo oo oo oo oooooo oo oo oooooo o o oooooooo oo ooooo oo oo oo o oo oo oooo oo o oo oo oooooo oo oooooo oooooo oooo oo oo oo oo oo oo oo oo oo oo oo oooooooo oo o oo oo oo oo oooooo ooo ooooo o ooooo ============================================================================= pcaslab v2.00 (TM) A Computer Program for Analysis, Design, and Investigation of Reinforced Concrete Beams, One-way and Two-way Slab Systems ============================================================================= Copyright 2003-2006, Portland Cement Association All rights reserved Licensee stated above acknowledges that Portland Cement Association (PCA) is not and cannot be responsible for either the accuracy or adequacy of the material supplied as input for processing by the pcaslab computer program. Furthermore, PCA neither makes any warranty expressed nor implied with respect to the correctness of the output prepared by the pcaslab program. Although PCA has endeavored to produce pcaslab error free the program is not and cannot be certified infallible. The final and only responsibility for analysis, design and engineering documents is the licensees. Accordingly, PCA disclaims all responsibility in contract, negligence or other tort for any analysis, design or engineering documents prepared in connection with the use of the pcaslab program. ============================================================================================= [1] INPUT ECHO ============================================================================================= General Information: ==================== File name: c:\work\time Saving Design Aids\318-05\Rev 2\Data\.slb Project: Time Saving Design Aids Frame: Two-Way Slab Engineer: PCA Code: ACI 318-02 Reinforcement Database: ASTM A615 Mode: Design Number of supports = 4 Floor System: Two-Way Live load pattern ratio = 75% Minimum free edge for punching shear = 10 times slab thickness Deflections are based on cracked section properties. In negative moment regions, Ig and Mcr DO NOT include flange/slab contribution (if available) Long-term deflections are calculated for load duration of 60 months. 0% of live load is sustained. Compression reinforcement calculations NOT selected. Material Properties: ==================== Slabs Beams Columns ------------ ------------ wc = 150 150 lb/ft3 f'c = 4 4 ksi Ec = 3834.3 3834.3 ksi fr = 0.47434 0.47434 ksi fy = 60 ksi, Bars are not epoxy-coated fyv = 60 ksi Es = 29000 ksi Reinforcement Database: =============== Units: Db (in), Ab (in^2), Wb (lb/ft) Size Db Ab Wb Size Db Ab Wb ---- -------- -------- -------- ---- -------- -------- --------

TIME SAVING DESIGN AID Page 11 of 14 pcaslab v2.00 Portland Cement Association 05-03-2007, 11:27:26 AM Licensed to: pcastructurepoint, License ID: 12345-1234567-4-2D2DE-2C8D0 c:\work\time Saving Design Aids\318-05\Rev 2\Data\.slb Page 2 #3 0.38 0.11 0.38 #4 0.50 0.20 0.67 #5 0.63 0.31 1.04 #6 0.75 0.44 1.50 #7 0.88 0.60 2.04 #8 1.00 0.79 2.67 #9 1.13 1.00 3.40 #10 1.27 1.27 4.30 #11 1.41 1.56 5.31 #14 1.69 2.25 7.65 #18 2.26 4.00 13.60 Span Data: ========== Slabs: L1, wl, wr (ft); t, Hmin (in) Span Loc L1 t wl wr Hmin ---- ---- -------- -------- -------- -------- -------- 1 Int 20.000 9.00 12.000 12.000 7.27 2 Int 20.000 9.00 12.000 12.000 6.55 3 Int 20.000 9.00 12.000 12.000 7.27 Support Data: ============= Columns: c1a, c2a, c1b, c2b (in); Ha, Hb (ft) Supp c1a c2a Ha c1b c2b Hb Red% ---- -------- -------- -------- -------- -------- -------- ---- 1 20.00 20.00 10.000 20.00 20.00 10.000 100 2 24.00 24.00 10.000 24.00 24.00 10.000 100 3 24.00 24.00 10.000 24.00 24.00 10.000 100 4 20.00 20.00 10.000 20.00 20.00 10.000 100 Boundary Conditions: Kz (kip/in); Kry (kip-in/rad) Supp Spring Kz Spring Kry Far End A Far End B ---- ------------ ------------ --------- --------- 1 0 0 Fixed Fixed 2 0 0 Fixed Fixed 3 0 0 Fixed Fixed 4 0 0 Fixed Fixed Load Data: ========== Load Cases and Combinations: Case SELF Dead Live Type DEAD DEAD LIVE U1 1.400 1.400 0.000 U2 1.200 1.200 1.600 U3 1.200 1.200 1.600 U4 1.200 1.200 1.600 U5 1.200 1.200 1.000 U6 1.200 1.200 1.000 U7 0.900 0.900 0.000 U8 0.900 0.900 0.000 U9 1.200 1.200 1.000 U10 1.200 1.200 1.000 U11 0.900 0.900 0.000 U12 0.900 0.900 0.000 Span Loads: Span Case Wa ---- -------- ------------ Area Loads - Wa (lb/ft2): 1 Dead 30 2 Dead 30 3 Dead 30 1 Live 50 2 Live 50 3 Live 50 Support Loads - Fz (kip), My (k-ft): Supp Case Fz My ---- -------- ------------ ------------ 1 SELF 0 0 2 SELF 0 0 3 SELF 0 0 4 SELF 0 0 1 Live 0 0 2 Live 0 0 3 Live 0 0 4 Live 0 0 Support Displacements - D (in), R (rad): Supp Case D R ---- -------- ------------ ------------ 1 SELF 0 0 2 SELF 0 0 3 SELF 0 0 4 SELF 0 0 1 Live 0 0 2 Live 0 0 3 Live 0 0 4 Live 0 0

TIME SAVING DESIGN AID Page 12 of 14 pcaslab v2.00 Portland Cement Association 05-03-2007, 11:27:26 AM Licensed to: pcastructurepoint, License ID: 12345-1234567-4-2D2DE-2C8D0 c:\work\time Saving Design Aids\318-05\Rev 2\Data\.slb Page 3 Reinforcement Criteria: ======================= Top bars Bottom bars Stirrups Min Max Min Max Min Max ------- ------- ------- ------- ------- ------- Slabs and Ribs: Bar Size #4 #8 #4 #8 Bar spacing 1.00 18.00 1.00 18.00 in Reinf ratio 0.14 5.00 0.14 5.00 % Cover 1.50 1.50 in Beams: Bar Size #5 #8 #5 #8 #3 #5 Bar spacing 1.00 18.00 1.00 18.00 6.00 18.00 in Reinf ratio 0.14 5.00 0.14 5.00 % Cover 1.50 1.50 in Side cover 1.50 1.50 in Layer dist. 1.00 1.00 in No. of legs 2 6 ============================================================================================= [2] DESIGN RESULTS* ============================================================================================= *Unless otherwise noted, all results are in the direction of analysis only. Another analysis in the perpendicular direction has to be carried out for two-way slab systems. Top Reinforcement: ================== Units: Width (ft), Mmax (k-ft), Xmax (ft), As (in^2), Sp (in) Span Strip Zone Width Mmax Xmax AsMin AsMax SpReq AsReq Bars ---- ------ ------ -------- ------------ -------- -------- -------- -------- -------- ------- 1 Column Left 10.00 6.22 0.833 1.944 15.714 12.000 0.191 10-#4 Middle 10.00 0.00 9.917 0.000 15.714 0.000 0.000 --- Right 10.00 142.72 19.000 1.944 15.714 5.217 4.588 23-#4 Middle Left 14.00-0.00 0.833 0.000 22.000 0.000 0.000 --- Middle 14.00 0.00 9.917 0.000 22.000 0.000 0.000 --- Right 14.00 47.58 19.000 2.722 22.000 12.000 1.474 14-#4 2 Column Left 10.00 122.98 1.000 1.944 15.714 5.217 3.926 23-#4 Middle 10.00 0.00 10.000 0.000 15.714 0.000 0.000 --- Right 10.00 122.98 19.000 1.944 15.714 5.217 3.926 23-#4 Middle Left 14.00 40.99 1.000 2.722 22.000 12.000 1.268 14-#4 Middle 14.00 0.00 10.000 0.000 22.000 0.000 0.000 --- Right 14.00 40.99 19.000 2.722 22.000 12.000 1.268 14-#4 3 Column Left 10.00 142.72 1.000 1.944 15.714 5.217 4.588 23-#4 Middle 10.00 0.00 10.083 0.000 15.714 0.000 0.000 --- Right 10.00 6.22 19.167 1.944 15.714 12.000 0.191 10-#4 Middle Left 14.00 47.58 1.000 2.722 22.000 12.000 1.474 14-#4 Middle 14.00 0.00 10.083 0.000 22.000 0.000 0.000 --- Right 14.00-0.00 19.167 0.000 22.000 0.000 0.000 --- Top Bar Details: ================ Units: Length (ft) Left Continuous Right Span Strip Bars Length Bars Length Bars Length Bars Length Bars Length ---- ------ ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- 1 Column 10-#4 6.83 --- --- 12-#4 7.00 11-#4 4.63 Middle --- --- --- 14-#4 6.12 --- 2 Column 12-#4 6.94 11-#4 4.60 --- 12-#4 6.94 11-#4 4.60 Middle 14-#4 6.87 --- --- 14-#4 6.87 --- 3 Column 12-#4 7.00 11-#4 4.63 --- 10-#4 6.83 --- Middle 14-#4 6.12 --- --- --- --- Bottom Reinforcement: ===================== Units: Width (ft), Mmax (k-ft), Xmax (ft), As (in^2), Sp (in) Span Strip Width Mmax Xmax AsMin AsMax SpReq AsReq Bars ---- ------ -------- ------------ -------- -------- -------- -------- -------- ------- 1 Column 10.00 95.59 8.299 1.944 15.714 7.500 3.023 16-#4 Middle 14.00 63.73 8.299 2.722 22.000 12.000 1.982 14-#4 2 Column 10.00 52.89 10.000 1.944 15.714 12.000 1.649 10-#4 Middle 14.00 35.26 10.000 2.722 22.000 12.000 1.089 14-#4 3 Column 10.00 95.59 11.701 1.944 15.714 7.500 3.023 16-#4 Middle 14.00 63.73 11.701 2.722 22.000 12.000 1.982 14-#4 Bottom Bar Details: ===================

TIME SAVING DESIGN AID Page 13 of 14 pcaslab v2.00 Portland Cement Association 05-03-2007, 11:27:27 AM Licensed to: pcastructurepoint, License ID: 12345-1234567-4-2D2DE-2C8D0 c:\work\time Saving Design Aids\318-05\Rev 2\Data\.slb Page 4 Units: Start (ft), Length (ft) Long Bars Short Bars Span Strip Bars Start Length Bars Start Length ---- ------- ------- ------- ------- ------- ------- ------- 1 Column 16-#4 0.00 20.00 --- Middle 14-#4 0.00 20.00 --- 2 Column 10-#4 0.00 20.00 --- Middle 14-#4 0.00 20.00 --- 3 Column 16-#4 0.00 20.00 --- Middle 14-#4 0.00 20.00 --- Flexural Capacity: ================== Units: x (ft), As (in^2), PhiMn (k-ft) Span Strip x AsTop AsBot PhiMn- PhiMn+ ---- ------ --------- ----- ----- ------------ ------------ 1 Column 0.000 2.00 3.20-63.93 101.01 0.833 2.00 3.20-63.93 101.01 5.829 2.00 3.20-63.93 101.01 6.829 0.00 3.20 0.00 101.01 7.192 0.00 3.20 0.00 101.01 10.000 0.00 3.20 0.00 101.01 12.642 0.00 3.20 0.00 101.01 13.005 0.00 3.20 0.00 101.01 14.005 2.40 3.20-76.39 101.01 15.366 2.40 3.20-76.39 101.01 16.366 4.60 3.20-143.07 101.01 19.000 4.60 3.20-143.07 101.01 20.000 4.60 3.20-143.07 101.01 Middle 0.000 0.00 2.80 0.00 89.50 0.833 0.00 2.80 0.00 89.50 7.192 0.00 2.80 0.00 89.50 10.000 0.00 2.80 0.00 89.50 12.642 0.00 2.80 0.00 89.50 13.883 0.00 2.80 0.00 89.50 14.883 2.80 2.80-89.50 89.50 19.000 2.80 2.80-89.50 89.50 20.000 2.80 2.80-89.50 89.50 2 Column 0.000 4.60 2.00-143.07 63.93 1.000 4.60 2.00-143.07 63.93 3.601 4.60 2.00-143.07 63.93 4.601 2.40 2.00-76.39 63.93 5.940 2.40 2.00-76.39 63.93 6.940 0.00 2.00 0.00 63.93 7.300 0.00 2.00 0.00 63.93 10.000 0.00 2.00 0.00 63.93 12.700 0.00 2.00 0.00 63.93 13.060 0.00 2.00 0.00 63.93 14.060 2.40 2.00-76.39 63.93 15.399 2.40 2.00-76.39 63.93 16.399 4.60 2.00-143.07 63.93 19.000 4.60 2.00-143.07 63.93 20.000 4.60 2.00-143.07 63.93 Middle 0.000 2.80 2.80-89.50 89.50 1.000 2.80 2.80-89.50 89.50 5.875 2.80 2.80-89.50 89.50 6.875 0.00 2.80 0.00 89.50 7.300 0.00 2.80 0.00 89.50 10.000 0.00 2.80 0.00 89.50 12.700 0.00 2.80 0.00 89.50 13.125 0.00 2.80 0.00 89.50 14.125 2.80 2.80-89.50 89.50 19.000 2.80 2.80-89.50 89.50 20.000 2.80 2.80-89.50 89.50 3 Column 0.000 4.60 3.20-143.07 101.01 1.000 4.60 3.20-143.07 101.01 3.634 4.60 3.20-143.07 101.01 4.634 2.40 3.20-76.39 101.01 5.995 2.40 3.20-76.39 101.01 6.995 0.00 3.20 0.00 101.01 7.358 0.00 3.20 0.00 101.01 10.000 0.00 3.20 0.00 101.01 12.808 0.00 3.20 0.00 101.01 13.171 0.00 3.20 0.00 101.01 14.171 2.00 3.20-63.93 101.01 19.167 2.00 3.20-63.93 101.01 20.000 2.00 3.20-63.93 101.01 Middle 0.000 2.80 2.80-89.50 89.50 1.000 2.80 2.80-89.50 89.50 5.117 2.80 2.80-89.50 89.50 6.117 0.00 2.80 0.00 89.50 7.358 0.00 2.80 0.00 89.50 10.000 0.00 2.80 0.00 89.50

TIME SAVING DESIGN AID Page 14 of 14 pcaslab v2.00 Portland Cement Association 05-03-2007, 11:27:27 AM Licensed to: pcastructurepoint, License ID: 12345-1234567-4-2D2DE-2C8D0 c:\work\time Saving Design Aids\318-05\Rev 2\Data\.slb Page 5 12.808 0.00 2.80 0.00 89.50 19.167 0.00 2.80 0.00 89.50 20.000 0.00 2.80 0.00 89.50 Slab Shear Capacity: ==================== Units: b, d (in), Xu (ft), PhiVc, Vu(kip) Span b d Vratio PhiVc Vu Xu ---- -------- -------- -------- ------------ ------------ ------------ 1 288.00 7.25 1.000 198.09 61.26 18.40 2 288.00 7.25 1.000 198.09 50.58 18.40 3 288.00 7.25 1.000 198.09 61.26 1.60 Flexural Transfer of Negative Unbalanced Moment at Supports: ============================================================ Units: Width (in), Munb (k-ft), As (in^2) Supp Width GammaF*Munb Comb Pat AsReq AsProv Additional Bars ---- -------- ------------ ---- ---- -------- -------- --------------- 1 47.00 30.23 U2 All 0.950 0.783 1-#4 2 51.00 33.44 U2 Odd 1.051 1.955 --- 3 51.00 33.44 U2 Odd 1.051 1.955 --- 4 47.00 30.23 U2 All 0.950 0.783 1-#4 Punching Shear Around Columns: ============================== Units: Vu (kip), Munb (k-ft), vu (psi), Phi*vc (psi) Supp Vu vu Munb Comb Pat GammaV vu Phi*vc ---- ------------ -------- ------------ ---- ---- ------ -------- -------- 1 48.92 129.4 3.20 U2 All 0.320 134.6 189.7 2 129.49 149.2-37.01 U2 All 0.400 168.7 189.7 3 129.49 149.2 37.01 U2 All 0.400 168.7 189.7 4 48.92 129.4-3.20 U2 All 0.320 134.6 189.7 Deflections: ============ Section properties ------------------ Units: Ig, Icr, Ie (in^4), Mcr, Mmax (k-ft) Load Level Ie,avg Dead Dead+Live Span Dead Dead+Live Zone Ig Icr Mcr Mmax Ie Mmax Ie ---- ----------- ----------- ------ ----------- ----------- -------- -------- ----------- -------- ----------- 1 17496 16272 Middle 17496 1816 153.69 90.45 17496 122.19 17496 Right 17496 2174 153.69-146.59 17496-198.03 9336 2 17496 16317 Left 17496 2174 153.69-125.58 17496-169.64 13567 Middle 17496 1494 153.69 45.42 17496 61.36 17496 Right 17496 2174 153.69-125.58 17496-169.64 13567 3 17496 16272 Left 17496 2174 153.69-146.59 17496-198.03 9336 Middle 17496 1816 153.69 90.45 17496 122.19 17496 Maximum Instantaneous Deflections - Direction of Analysis --------------------------------------------------------- Units: D (in), Ig (in^4) Frame Strips Span Ddead Dlive Dtotal Strip Ig LDF Ratio Ddead Dlive Dtotal ---- -------- -------- -------- ------- ------------ ------ ------ -------- -------- -------- 1 0.074 0.032 0.106 Column 7290 0.738 1.770 0.132 0.056 0.188 Middle 10206 0.262 0.450 0.034 0.014 0.048 2 0.022 0.009 0.031 Column 7290 0.675 1.620 0.036 0.015 0.051 Middle 10206 0.325 0.557 0.012 0.005 0.017 3 0.074 0.032 0.106 Column 7290 0.738 1.770 0.132 0.056 0.188 Middle 10206 0.262 0.450 0.034 0.014 0.048 Maximum Long-term Deflections - Direction of Analysis ----------------------------------------------------- Time dependant factor for sustained loads = 2.000 Units: D (in) Column Strip Middle Strip Span Dsust Lambda Dcs Dcs+lu Dcs+l Dtotal Dsust Lambda Dcs Dcs+lu Dcs+l Dtotal ---- -------- ------ -------- -------- -------- -------- -------- ------ -------- -------- -------- -------- 1 0.132 2.000 0.264 0.320 0.320 0.451 0.034 2.000 0.067 0.081 0.081 0.115 2 0.036 2.000 0.071 0.086 0.086 0.122 0.012 2.000 0.024 0.030 0.030 0.042 3 0.132 2.000 0.264 0.320 0.320 0.451 0.034 2.000 0.067 0.081 0.081 0.115 Material Takeoff: ================= Reinforcement in the Direction of Analysis ------------------------------------------ Top Bars: 693.4 lb <=> 11.56 lb/ft <=> 0.481 lb/ft^2 Bottom Bars: 1122.2 lb <=> 18.70 lb/ft <=> 0.779 lb/ft^2 Stirrups: 0.0 lb <=> 0.00 lb/ft <=> 0.000 lb/ft^2 Total Steel: 1815.6 lb <=> 30.26 lb/ft <=> 1.261 lb/ft^2 Concrete: 1080.0 ft^3 <=> 18.00 ft^3/ft <=> 0.750 ft^3/ft^2