00W Reliable Green Medical Power Supply RPS-00 series + + Ⅰ Ⅱ Extremely low leakage current Ⅰ Ⅱ μ Type File Name:RPS-00-SPEC 06--09
SPECIFICATION MODEL OUTPUT INPUT DC VOLTAGE CURRENT RATED POWER 0CFM 0CFM LINE REGULATION VOLTAGE ADJ. RANGE LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE Note.4 FREQUENCY RANGE POWER FACTOR EFFICIENCY (Typ.) FUNCTION FAN SUPPLY INRUSH CURRENT (Typ.) OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 0 ~ 95% RH non-condensing OTHERS NOTE AC CURRENT (Typ.) OVERLOAD PROTECTION OVER VOLTAGE SAFETY & EMC (Note 7) TEMP. COEFFICIENT VIBRATION ISOLATION RESISTANCE MTBF DIMENSION (L*W*H) PACKING 6.7A.7A RIPPLE & NOISE (max.) Note. 00mVp-p ±0.5% ±.0% 700ms, 0ms/0VAC 6ms/0VAC 700ms, 0ms/5VAC at full load 6ms/5VAC at full load 80 ~ 64VAC ~ 70VDC 47 ~ 6Hz PF>0.94/0VAC PF>0.98/5VAC at full load 9% 9.5% 94% A/5VAC A/0VAC COLD START 0A/5VAC 0 ~ 40% rated output power. ~ 5.6V 6.5 ~ 9.5V 60A/0VAC 6.4 ~.V RPS-00 series.4~.6v 4.~5.8V.8~5.V 5.6 ~ 8.4V 45.6 ~50.4V VOLTAGE TOLERANCE Note. ±.0% ±.0% ±.0% ±.0% ±.0% SAFETY STANDARDS RPS-00- RPS-00-5 RPS-00-4 RPS-00-7 RPS-00-48 V 00.4W 94% Protection type : Hiccup mode, recovers automatically after fault condition is removed V@0.5A for driving a fan ; tolerance +5% ~ -5% -0 ~ +70 (Refer to "Derating Curve") 0 ~ 90% RH non-condensing ±0.0%/ (0 ~ 50 ) ±0.5% ±.0% 0 ~ 500Hz, G 0min./cycle, 60min. each along X, Y, Z axes 500.Khrs min. MIL-HDBK-7F (5 ) 5V 4V 7V 48V.4A 9.4A 0W 40.4W 4W 8.4A 5.9A 0.6W 4.6W 00mVp-p 0mVp-p 0mVp-p 0mVp-p ±0.5% ±.0% ±0.5% ±0.5% ±.0% ±.0% 95% 9.7 ~ 5V 5.8 ~ 6.4V PCB:0.6*50.8*9mm or 4 * *.4 inch ; Enclosed type:0.4*6*40mm or 4.07 *.44 *.57 inch 7.5A 5.A 0.5W 4.W LEAKAGE CURRENT(max.)Note.5 Earth leakage current < 0 μa/64vac, Touch current < 40 μa/64vac WITHSTAND VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover Protection type : Shut down o/p voltage, re-power on to recover IEC6060-, TUV EN6060-, EAC TP TC 004,UL ANSI / AAMI ES6060- (. version), CAN/CSA-C. No. 6060-:4 - Edition approved; Design refer to EN605- Primary-Secondary: xmopp, Primary-Earth:xMOPP, Secondary-Earth:xMOPP I/P-O/P:4KVAC I/P-FG:KVAC O/P-FG:.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG:00M Ohms / 500VDC / 5 / 70% RH EMC EMISSION EMC IMMUNITY 00W Reliable Green Medical Power Supply OPERATING ALTITUDE Note.6 4000 meters Parameter Conducted emission Radiated emission Harmonic current Voltage flicker EN6060-- Parameter ESD RF field susceptibility EFT bursts Surge susceptibility Conducted susceptibility Magnetic field immunity Voltage dip, interruption Standard EN550 (CISPR) EN550 (CISPR) EN6000-- EN6000-- Standard EN6000-4- EN6000-4- EN6000-4-4 EN6000-4-5 EN6000-4-6 EN6000-4-8 EN6000-4- PCB:0.9Kg; 7pcs/4.7Kg/0.8CUFT ; Enclosed type:0.kg; 60pcs/9Kg/.CUFT 4.A A Test Level / Note Class B Class B Class A Test Level / Note 0.6W μ μ 6. ----- 44W Level 4, 5KV air ; Level 4, 8KV contact Level, 0V/m( 80MHz~.7GHz ) Table 9, 9~8V/m( 85MHz~5.78GHz ) Level, KV Level 4, 4KV/Line-FG ; KV/Line-Line Level, 0V Level 4, 0A/m 00% dip periods, 0% dip 5 periods, 00% interruptions 50 periods
00W Reliable Green Medical Power Supply RPS-00 series Block Diagram fosc : 65KHz I/P EMI FILTER EMI FILTER & RECTIFIER POWER SWITCHING RECTIFIERS & FILTER +V -V FG RECTIFIERS & FILTER +V FAN supply O.T.P. O.L.P. CONTROL DETECTION CIRCUIT O.V.P. Derating Curve Output Derating VS Input Voltage LOAD (%) 00 80 70 60 40 0 With 0CFM Fan for RPS-00(-C) for RPS-00 4~48V for RPS-00-C V~48V & RPS-00 V~5V LOAD (%) 00 90 80 70 60 50 40 With 0CFM Fan for RPS-00(-C) -0 0 0 0 0 40 45 AMBIENT TEMPERATURE ( ) 50 60 70 (HORIZONTAL) 80 90 5 0 0 40 60 80 00 0 40 64 INPUT VOLTAGE (VAC) 60Hz
00W Reliable Green Medical Power Supply RPS-00 series Mechanical Specification RPS-00 (PCB Type) Top View Note FAN 0CFM 50.8 44.45.75 CN FS FS T4A/50V F4A/50V 50mm Air flow direction LED SVR CN0 CN 4 5 6 4-ψ..75 95.5 0.6 max. 9
00W Reliable Green Medical Power Supply RPS-00 series RPS-00-C (Enclosed Type) Case No.45A Unit:mm Top View 0.4.7 78.7 00 -R.75 -M L=4 5 0 40 50mm FAN 0CFM Air flow direction 6 0.8 CN -M L= CN0 CN 4 5 6 4. 55 Bottom View
00W Reliable Green Medical Power Supply RPS-00 series AC Input Connector (CN) : JST BP-VH Pin No. Assignment AC/L No Pin AC/N Mating Housing JST VHR Terminal JST SVH-T-P. DC Output Connector (CN) : JST B6P-VH Pin No.,, 4,5,6 Assignment +V -V Mating Housing JST VHR Terminal JST SVH-T-P. FAN Connector(CN0) : Pin No. Assignment DC COM +V JST BB-PH-K-S Mating Housing JST PHR- Terminal JST SPH-00T-P0.5S Note :. The FAN supply is designed to serve as the source of the additive external fan for the cooling of the power supply, enabling the full load delivery and assuring the best life span of the product. Please do not use this FAN supply to drive other devices..the PCB type(blank type)model delivers EMI Class B for both conducted emission and radiated emission for the power supply, when configured into either Class Ⅰ(with FG).The enclosed type(-c type) model is not suitable for the configuration within a Class Ⅱ (no FG) system but is suggested to used within a Class Ⅰ(with FG) system. Installation Manual Please refer to : http://www.meanwell.com/manual.html