THOMAS SAMUEL THOMAS SAMUEL 65W PWM Output LED Driver IP67 IS 15885(Part 2/Sec13) (for enclosure design only) R41027766 ( for ODLV6512,24,48 only) S&E A
SPECIFICATION MODEL OUTPUT OTHERS NOTE DC VOLTAGE RATED CURRENT RATED POWER DIMMING RANGE VOLTAGE TOLERANCE PWM FREQUENCY (Typ.) SETUP TIME Note.3 AUXILIARY DC OUTPUT Note.4 VOLTAGE RANGE Note.2 FREQUENCY RANGE POWER FACTOR (Typ.) MTBF DIMENSION PACKING ODLV65 12 ODLV65 24 ODLV65 36 ODLV65 48 ODLV65 60 12V 24V 36V 48V 60V 4.2A 2.4A 1.8A 1.35A 1.08A 50.4W 57.6W 64.8W 64.8W 64.8W 0~100% ±10% 1KHz( ± 20%) 500ms / 2VAC Nominal 12V(deviation 11.4~12.6)@50mA for AType only 180 ~ 295VAC 254 ~ 417VDC (Please refer to "STATIC CHARACTERISTIC" section) 47 ~ 63Hz PF>0.95/2VAC, PF>0.9/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section) INPUT TOTAL HARMONIC DISTORTION THD< 20%(@load 60%/2VAC; @load 75%/277VAC) (Please refer to TOTAL HARMONIC DISTORTION section) EFFICIENCY (Typ.) AC CURRENT (Typ.) 85% 0.4A/2VAC 87% 0.3A/277VAC 88% 89% 90% INRUSH CURRENT(Typ.) MAX. No. of PSUs on 16A CIRCUIT BREAKER COLD START A(twidth= 270μ s measured at 50% Ipeak) at 2VAC; Per NEMA 410 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 2VAC LEAKAGE CURRENT <0.75mA / 277VAC NO LOAD POWER CONSUMPTION <0.5W for BlankType, <1.2W for AType SHORT CIRCUIT Shut down O/P voltage, repower on to recovery PROTECTION 105 ~ 115% OVER CURRENT Protection type : Hiccup mode, recovers automatically after fault condition is removed WORKING TEMP. Tcase=20 ~ 85 (Please refer to OUTPUT LOAD vs TEMPERATURE section) MAX. CASE TEMP. Tcase=85 WORKING HUMIDITY 20 ~ 90% RH noncondensing ENVIRONMENT STORAGE TEMP., HUMIDITY 40 ~ 80, 10 ~ 95% RH TEMP. COEFFICIENT VIBRATION ± 0.03%/ (0 ~ 45 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS UL8750 (type HL ),CSA C22.2 NO.250.1312; ENEC EN613471 & EN61347213 independent, EN62384,GB19510.1,GB19510.14; BIS IS15885( for ODLV6512,24,48 only), EAC TP TC 004,IP67 approved SAFETY & WITHSTAND VOLTAGE I/PO/P:3.75KVAC EMC ISOLATION RESISTANCE I/PO/P:100M Ohms / 500VDC / 25 / 70% RH EMC EMISSION Compliance to EN55015, EN6100032 Class C (@load 60%) ; EN6100033,GB17743,GB17625.1,EAC TP TC 020 EMC IMMUNITY Compliance to EN6100042,3,4,5,6,8,11; EN61547, light industry level( surge immunity:lineline:1kv),eac TP TC 020 398.7K hrs min. MILHDBK217F (25 ) 121*77*28.5mm (L*W*H) 0.43Kg;24pcs/11.3Kg/ 0.74CUFT
DIMMING OPERATION AUX(Green) AUX(Yellow) Vo(Black) Vo(Red) DIM(Gray) DIM(Purple) ACN(Blue) ACL(Brown) Dimming principle for PWM style output Dimming is achieved by varying the duty cycle of the output current. Output DC current ON TON Duty cycle(%) = 100% T Io=0A TON OFF Output PWM frequency : 1KHz ( ± 20%) T 2 in 1 dimming function Applying additive 0 ~ 10VDC 100% 90% Vo Vo DIM DIM Additive Voltage Duty cycle of output current (%) 80% 70% 60% 50% 40% % 20% 10% DO NOT connect "DIM to Vo 0% 0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V Dimming input: Additive voltage Applying additive 10V PWM signal (frequency range 0Hz~3KHz): Vo Vo DIM DIM DO NOT connect "DIM to Vo Additive PWM signal Duty cycle of output current (%) 100% 90% 80% 70% 60% 50% 40% % 20% 10% 0% 0% 10% 20% % 40% 50% 60% 70% 80% 90% 100% Duty cycle of additive 10V PWM signal dimming input Note : 1. Min. duty cycle of output current is about 8% and the output current is not defined when 0%< Iout<8%. 2. The duty cycle of output current could drop down to 0% when dimming input is about 0Vdc or 10V PWM signal with 0% duty cycle. 3. To ensure the dimming effect, total power must be over 45W at 100% duty cycle.
OUTPUT LOAD vs TEMPERATURE 100 100 80 80 LOAD (%) 60 40 20 LOAD (%) 60 40 20 20 10 0 5 10 20 45 (HORIZONTAL) 20 10 0 15 45 75 85 (HORIZONTAL) AMBIENT TEMPERATURE,Ta ( ) Tcase ( ) STATIC CHARACTERISTIC POWER FACTOR (PF) CHARACTERISTIC Tcase at 75 100 1 90 0.95 LOAD (%) 80 70 60 50 PF 0.9 0.85 0.8 277V 2V 40 0.75 180 200 2 260 295 0.7 50% 60% 70% 80% 90% 100% INPUT VOLTAGE (V) (65W) Derating is needed under low input voltage. LOAD TOTAL HARMONIC DISTORTION (THD) EFFICIENCY vs LOAD possess superior working efficiency that up to 90% can be reached in field applications. 60V Model, Tcase at 75 60VModel, Tcase at 75 18 96 THD 16 14 12 10 8 6 4 277VAC 2VAC EFFICIENCY(%) 91 86 81 76 277V 2V 2 0 50% 60% 70% 80% 90% 100% LOAD 71 66 10% 20% % 40% 50% 60% 70% 80% 90% 100% LOAD
BLOCK DIAGRAM fosc : 70150KHz RECTIFIERS AUX(for AType) AUX(for AType) I/P EMI FILTER & RECTIFIERS POWER SWITCHING RECTIFIERS & FILTER CURRENT LIMIT Vo Vo DIM DIM O.L.P. PWM&PFC CONTROL DETECTION CIRCUIT MECHANICAL SPECIFICATION Case No.ODL65A Unit:mm BlankType: 121 Vo(Black) Vo(Red) DIM(Gray) DIM(Purple) 150±10 tc 77 ACN(Blue) ACL(Brown) 2* ψ4.5 28.5 tc : Max. Case Temperature AC wire No. Assignment(AC IN) ACN(Blue) SVT 18AWG ACL(Brown) SVT 18AWG DC wire No. Assignment(DC OUT) Vo(Black) UL1007 18AWG Vo(Red) UL1007 18AWG DIM(Gray) UL1007 22AWG DIM(Purple) UL1007 22AWG 2.5
AType: 121 AUX(Green) AUX(Yellow) Vo(Black) Vo(Red) DIM(Gray) DIM(Purple) 150±10 150±10 tc 77 ACN(Blue) ACL(Brown) tc : Max. Case Temperature 2* ψ4.5 28.5 AC wire No. Assignment(AC IN) ACN(Blue) SVT 18AWG ACL(Brown) SVT 18AWG DC wire No. Assignment(DC OUT) AUX(Green) UL1007 22AWG AUX(Yellow) UL1007 22AWG Vo(Black) UL1007 18AWG Vo(Red) UL1007 18AWG DIM(Gray) UL1007 22AWG DIM(Purple) UL1007 22AWG 2.5 Recommend Mounting Direction Installation Manual Please refer to : http://www.meanwell.com/manual.html