of concrete buildings Illustration of elements design

Σχετικά έγγραφα
CONSULTING Engineering Calculation Sheet

MECHANICAL PROPERTIES OF MATERIALS

5.0 DESIGN CALCULATIONS

APPENDIX 1: Gravity Load Calculations. SELF WEIGHT: Slab: 150psf * 8 thick slab / 12 per foot = 100psf ROOF LIVE LOAD:

ΑΝΩΤΑΤΗ ΣΧΟΛΗ ΠΑΙ ΑΓΩΓΙΚΗΣ ΚΑΙ ΤΕΧΝΟΛΟΓΙΚΗΣ ΕΚΠΑΙ ΕΥΣΗΣ ΠΑΡΑΔΟΤΕΟ ΕΠΙΣΤΗΜΟΝΙΚΗ ΕΡΓΑΣΙΑ ΣΕ ΔΙΕΘΝΕΣ ΕΠΙΣΤΗΜΟΝΙΚΟ ΠΕΡΙΟΔΙΚΟ

Strain gauge and rosettes

Math 6 SL Probability Distributions Practice Test Mark Scheme

HOMEWORK 4 = G. In order to plot the stress versus the stretch we define a normalized stretch:

Chapter 7 Transformations of Stress and Strain

EE512: Error Control Coding

DESIGN OF MACHINERY SOLUTION MANUAL h in h 4 0.

Το σχέδιο της μέσης τομής πλοίου

STRUCTURAL CALCULATIONS FOR SUSPENDED BUS SYSTEM SEISMIC SUPPORTS SEISMIC SUPPORT GUIDELINES

Reminders: linear functions

Περίπτωση Μελέτης Θαλάσσιας Κατασκευής με χρήση λογισμικού και με βάση Κώδικες (Compliant Tower) (8.1.10)

the total number of electrons passing through the lamp.

Right Rear Door. Let's now finish the door hinge saga with the right rear door

Introduction to Theory of. Elasticity. Kengo Nakajima Summer


Lecture 2: Dirac notation and a review of linear algebra Read Sakurai chapter 1, Baym chatper 3

Surface Mount Multilayer Chip Capacitors for Commodity Solutions

ΕΛΕΓΧΟΣ ΤΩΝ ΠΑΡΑΜΟΡΦΩΣΕΩΝ ΧΑΛΥΒ ΙΝΩΝ ΦΟΡΕΩΝ ΜΕΓΑΛΟΥ ΑΝΟΙΓΜΑΤΟΣ ΤΥΠΟΥ MBSN ΜΕ ΤΗ ΧΡΗΣΗ ΚΑΛΩ ΙΩΝ: ΠΡΟΤΑΣΗ ΕΦΑΡΜΟΓΗΣ ΣΕ ΑΝΟΙΚΤΟ ΣΤΕΓΑΣΤΡΟ

Απόκριση σε Μοναδιαία Ωστική Δύναμη (Unit Impulse) Απόκριση σε Δυνάμεις Αυθαίρετα Μεταβαλλόμενες με το Χρόνο. Απόστολος Σ.

Phys460.nb Solution for the t-dependent Schrodinger s equation How did we find the solution? (not required)

ANSWERSHEET (TOPIC = DIFFERENTIAL CALCULUS) COLLECTION #2. h 0 h h 0 h h 0 ( ) g k = g 0 + g 1 + g g 2009 =?

Mechanical Behaviour of Materials Chapter 5 Plasticity Theory

Struct4u b.v. Calculation number : Revision : 0 Page 1 of 8 Project number : Date - time : :25 Project description : Part :

COMPOSITE SLABS DESIGN CONTENTS

CHAPTER 25 SOLVING EQUATIONS BY ITERATIVE METHODS

MasterSeries MasterPort Lite Sample Output

Mechanics of Materials Lab

Approximation of distance between locations on earth given by latitude and longitude

Ingenieurbüro Frank Blasek - Beratender Ingenieur Am Kohlhof 10, Osterholz-Scharmbeck Tel: 04791/ Fax: 04791/

Ingenieurbüro Frank Blasek - Beratender Ingenieur Am Kohlhof 10, Osterholz-Scharmbeck Tel: 04791/ Fax: 04791/

Figure 1 - Plan of the Location of the Piles and in Situ Tests

Dr. D. Dinev, Department of Structural Mechanics, UACEG

Cross sectional area, square inches or square millimeters

Homework 8 Model Solution Section

Stresses in a Plane. Mohr s Circle. Cross Section thru Body. MET 210W Mohr s Circle 1. Some parts experience normal stresses in

The Simply Typed Lambda Calculus

Areas and Lengths in Polar Coordinates

derivation of the Laplacian from rectangular to spherical coordinates

Math221: HW# 1 solutions

Second Order RLC Filters

CHAPTER 48 APPLICATIONS OF MATRICES AND DETERMINANTS

CRASH COURSE IN PRECALCULUS

3.4 SUM AND DIFFERENCE FORMULAS. NOTE: cos(α+β) cos α + cos β cos(α-β) cos α -cos β

DERIVATION OF MILES EQUATION FOR AN APPLIED FORCE Revision C

Areas and Lengths in Polar Coordinates

[1] P Q. Fig. 3.1

BEHAVIOR OF MASSIVE EARTH RETAINING WALLS UNDER EARTHQUAKE SHAKING Comparisons to EC-8 Provisions

1 String with massive end-points

The challenges of non-stable predicates

Section 9.2 Polar Equations and Graphs

Second Order Partial Differential Equations

Instruction Execution Times

Section 8.3 Trigonometric Equations

Graded Refractive-Index

ΕΙΣΑΓΩΓΗ ΣΤΗ ΣΤΑΤΙΣΤΙΚΗ ΑΝΑΛΥΣΗ

Multilayer Ceramic Chip Capacitors

9.09. # 1. Area inside the oval limaçon r = cos θ. To graph, start with θ = 0 so r = 6. Compute dr

ΚΥΠΡΙΑΚΗ ΕΤΑΙΡΕΙΑ ΠΛΗΡΟΦΟΡΙΚΗΣ CYPRUS COMPUTER SOCIETY ΠΑΓΚΥΠΡΙΟΣ ΜΑΘΗΤΙΚΟΣ ΔΙΑΓΩΝΙΣΜΟΣ ΠΛΗΡΟΦΟΡΙΚΗΣ 19/5/2007

Delhi Noida Bhopal Hyderabad Jaipur Lucknow Indore Pune Bhubaneswar Kolkata Patna Web: Ph:

2 Composition. Invertible Mappings

6.1. Dirac Equation. Hamiltonian. Dirac Eq.

Multilayer Ceramic Chip Capacitors

Other Test Constructions: Likelihood Ratio & Bayes Tests

6.4 Superposition of Linear Plane Progressive Waves

Homework 3 Solutions

A, B. Before installation of the foam parts (A,B,C,D) into the chambers we put silicone around. We insert the foam parts in depth shown on diagram.

Review Test 3. MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

Α ιθ EL. 3. Κα ασ ασ ής: fischerwerke GmbH & Co. KG, Klaus-Fischer-Straße 1, Waldachtal, α ία. Tumlingen,

Partial Differential Equations in Biology The boundary element method. March 26, 2013

CHAPTER 12: PERIMETER, AREA, CIRCUMFERENCE, AND 12.1 INTRODUCTION TO GEOMETRIC 12.2 PERIMETER: SQUARES, RECTANGLES,

ΕΘΝΙΚΟ ΜΕΤΣΟΒΙΟ ΠΟΛΥΤΕΧΝΕΙΟ ΣΧΟΛΗ ΠΟΛΙΤΙΚΩΝ ΜΗΧΑΝΙΚΩΝ ΤΟΜΕΑΣ ΟΜΟΣΤΑΤΙΚΗΣ ΕΡΓΑΣΤΗΡΙΟ ΜΕΤΑΛΛΙΚΩΝ ΚΑΤΑΣΚΕΥΩΝ

b. Use the parametrization from (a) to compute the area of S a as S a ds. Be sure to substitute for ds!

D28 1-1/4" PIPE x 42-1/2" HIGH RAIL WITHOUT BOTTOM RAIL

EN ΔΙΑΣΤΑΣΙΟΛΟΓΗΣΗ ΔΟΚΟΥ Ο.Σ. ΓΙΑ ΣΕΙΣΜΙΚΑ ΦΟΡΤΊΑ. γεωμετρία: b= 0,30 m h= 0,70 m L= 6,00 m L/h= 8,57 Εντατικά Μεγέθη Σχεδιασμού

ΣΧΕΔΙΑΣΜΟΣ ΚΑΙ ΕΝΙΣΧΥΣΗ ΤΩΝ ΚΟΜΒΩΝ ΟΠΛΙΣΜΕΝΟΥ ΣΚΥΡΟΔΕΜΑΤΟΣ ΜΕ ΒΑΣΗ ΤΟΥΣ ΕΥΡΩΚΩΔΙΚΕΣ

ΠΑΡΟΥΣΙΑΣΗ ΔΙΠΛΩΜΑΤΙΚΗΣ ΕΡΓΑΣΙΑΣ

; +302 ; +313; +320,.

Μονοβάθμια Συστήματα: Εξίσωση Κίνησης, Διατύπωση του Προβλήματος και Μέθοδοι Επίλυσης. Απόστολος Σ. Παπαγεωργίου

CSR series. Thick Film Chip Resistor Current Sensing Type FEATURE PART NUMBERING SYSTEM ELECTRICAL CHARACTERISTICS

Example Sheet 3 Solutions

Capacitors - Capacitance, Charge and Potential Difference

Section 7.6 Double and Half Angle Formulas

ΚΥΠΡΙΑΚΗ ΕΤΑΙΡΕΙΑ ΠΛΗΡΟΦΟΡΙΚΗΣ CYPRUS COMPUTER SOCIETY ΠΑΓΚΥΠΡΙΟΣ ΜΑΘΗΤΙΚΟΣ ΔΙΑΓΩΝΙΣΜΟΣ ΠΛΗΡΟΦΟΡΙΚΗΣ 6/5/2006

Finite Field Problems: Solutions

Assalamu `alaikum wr. wb.

Analyse af skrå bjælke som UPE200

Problem Set 9 Solutions. θ + 1. θ 2 + cotθ ( ) sinθ e iφ is an eigenfunction of the ˆ L 2 operator. / θ 2. φ 2. sin 2 θ φ 2. ( ) = e iφ. = e iφ cosθ.

DISCLAIMER By using the LOGIX Design Manual, in part or in whole, the user accepts the following terms and conditions.

Potential Dividers. 46 minutes. 46 marks. Page 1 of 11

DETERMINATION OF DYNAMIC CHARACTERISTICS OF A 2DOF SYSTEM. by Zoran VARGA, Ms.C.E.

UDZ Swirl diffuser. Product facts. Quick-selection. Swirl diffuser UDZ. Product code example:

C.S. 430 Assignment 6, Sample Solutions

PARTIAL NOTES for 6.1 Trigonometric Identities

Technical Data for Profiles. α ( C) = 250 N/mm 2 (36,000 lb./in. 2 ) = 200 N/mm 2 (29,000 lb./in 2 ) A 5 = 10% A 10 = 8%

Structural Design of Raft Foundation

ΠΑΝΕΠΙΣΤΗΜΙΟ ΠΕΙΡΑΙΑ ΤΜΗΜΑ ΝΑΥΤΙΛΙΑΚΩΝ ΣΠΟΥΔΩΝ ΠΡΟΓΡΑΜΜΑ ΜΕΤΑΠΤΥΧΙΑΚΩΝ ΣΠΟΥΔΩΝ ΣΤΗΝ ΝΑΥΤΙΛΙΑ

Transcript:

Dissemination of information for training Lisbon 10-11 February 2011 1 Specific rules for design and detailing of concrete buildings Design for DCM and DCH Illustration of elements design M.N. Fardis University of Patras (GR) G. Tsionis University of Patras (GR)

Structure of EN1998-1:2004 Dissemination of information for training Lisbon 10-11 February 2011 2 1. General 2. Performance Requirements and Compliance Criteria 3. Ground Conditions and Seismic Action 4. Design of Buildings 5. Specific Rules for Concrete Buildings 6. Specific Rules for Steel Buildings 7. Specific Rules for Steel-Concrete Composite Buildings 8. Specific Rules for Timber Buildings 9. Specific Rules for Masonry Buildings 10. Base Isolation

Design concepts for safety under design seismic action Dissemination of information for training Lisbon 10-11 February 2011 3 1. Design for energy dissipation (via ductility): q>1.5 Global ductility: Structure forced to remain straight in elevation through shear walls or strong columns (ΣM Rc >1.3ΣM Rb in frames): Local ductility: Plastic hinges detailed for ductility capacity derived from q-factor; Brittle failures prevented by overdesign/capacity it design Capacity design of foundations & foundation elements: On the basis of overstrength of ductile elements of superstructure. (Or: Foundation elements - incl. piles - designed & detailed for ductility) 2. Design w/o energy dissipation & ductility: q 1.5 for overstrength; design only according to EC2 & EC7 (Ductility Class Low DCL) Only: for Low Seismicity i it (NDP; recommended: d PGA on rock 0.08g) 08 ) for superstructure of base-isolated buildings.

Control of inelastic seismic response Dissemination of information for training Lisbon 10-11 February 2011 4 Soft-storey collapse mechanism to be avoided through proper structural configuration: Strong-column/weak beam frames, with beam-sway mechanisms, involving: - plastic hinging at all beam ends, and - either plastic hinging at column bottoms, or rotations at the foundation. Wall-equivalent dual frames, with beam-sway mechanism, involving: - plastic hinging at all beam ends, and -either plastic hinging at wall & column bottoms, or rotations at the foundation. (a) (b) (c) (d) (e) () (a) soft-storey t mechanism in weak column/strong beam frame; (b), (c) beam-sway mechanisms in strong column/ weak beam frame; (d), (e) beam-sway mechanisms in wall system

Overview of Eurocode 8 seismic design of RC buildings Dissemination of information for training Lisbon 10-11 February 2011 5 1. Damage limitation (storey drift ratio < 0.5-1%) under the damage limitation earthquake (~50% of design seismic action ), using 50% of uncracked gross section stiffness. 2. Member verification for the Ultimate Limit State (ULS) in bending under the design seismic action, with elastic spectrum reduced by the behaviour factor q. 3. In frames or frame-equivalent dual systems: Meet strong column/weak beam capacity design rule, with overstrength factor of 1.3 on beam strengths. 4. Capacity design of members (and joints) in shear. 5. Detailing of plastic hinge regions, on the basis of the value of the curvature ductility factor that corresponds to the q-factor value.

Column capacity design rule in frames Dissemination of information for training Lisbon 10-11 February 2011 6 Fulfilment of strong column/weak beam capacity design rule, with overstrength factor γ Rd on beam strengths: Eurocode 8: γ Rd = 13;strong 1.3; column/weak beam capacity design required only in frames or frame-equivalent dual systems (: frames resist >50% of seismic base shear) above two storeys (except at top storey joints). Beam & column flexural capacities at a joint in Capacity Design rule column 1 column 1 beam 1 beam 2 beam 1 beam 2 column 2 column 2

Dissemination of information for training Lisbon 10-11 February 2011 7 For the calculation of M Rb : Width of slab effective as tension flange of beams at the support to a column: b c b c a 2h f 2h f h f 4h f 4h f c h f b c d b c b 2h f 2h f h f h f a, b: at exterior column; c, d: at interior column: small is it safe for capacity design?

NDP-partial factors for materials, in ULS verifications: Dissemination of information for training Lisbon 10-11 February 2011 8 Recommended: use same values as for persistent & transient design situations (i.e. in concrete buildings: γ c =1.5, γ s =1.15); 15);

Seismic design of the foundation Dissemination of information for training Lisbon 10-11 February 2011 9 Objective: The ground and the foundation system should not reach its ULS before the superstructure, i.e. should remain elastic while inelasticity develops in the superstructure. Means: The ground and the foundation system are designed for their ULS under seismic action effects from the analysis derived for q=1.5, i.e. lower than the q-value l used for the design of the superstructure; t or The ground and the foundation system are designed for their ULS under seismic action effects from the analysis multiplied by γ Rd (R di /E di ) q, where R di force capacity in the dissipative zone or element controlling the seismic action effect of interest, E di the seismic action effect there from the elastic analysis and γ Rd =1.2 (γ Rd =1.0 if q 3.0) For individual spread footings of walls or columns of moment-resisting frames, R di /E di is the minimum value of M Rd /M Ed in the two orthogonal principal directions at the lowest cross-section section of the vertical element where a plastic hinge can form in the seismic design situation; For common foundations of more than one elements, γ Rd (R di /E di ) =1.4.

Frame, wall, or dual systems in RC buildings Dissemination of information for training Lisbon 10-11 February 2011 10 Eurocode 8 definitions: - Frame system: Frames take >65% of seismic base shear,v base - Wall system: Walls take > 65% of V base. - Dual system: Walls and frames take between 35 % & 65% of V base each. - Frame-equivalent equivalent dual system: Frames take between 50 % & 65% of V base. - Wall-equivalent dual system: Walls take between 50 % & 65% of V base. Eurocode 2 definition of wall: Wall column in that its cross-section is elongated (l w /b w >4)

For Dissipative Structures: Dissemination of information for training Lisbon 10-11 February 2011 11 Two Ductility Classes (DC): DC H (High) DC M (Medium). Differences in: q-values (q > 4 for DCH, 1.5 <q <4 for DCM) Local ductility requirements (ductility of materials, member detailing, capacity design against brittle failure modes)

Seismic design philosophy for RC buildings according to Eurocode 8 Dissemination of information for training Lisbon 10-11 February 2011 12 Ductility Classes (DC) Design based on energy dissipation and ductility: DC(M) Medium q = 3 x system overstrength factor ( 1.3). DC (H) High q= 4-4 4.5 x system overstrength factor ( 13) 1.3). The aim of the design is to control the inelastic seismic response: Structural configuration & relative sizing of members to ensure a beam-sway mechanism. Detailing of plastic hinge regions (beam ends, base of columns) to sustain inelastic deformation demands. Plastic hinge regions are detailed for deformation demands related to behaviour factor q: μ δ =q if Τ>Τ c μ δ =1+(q-1)T c /T if Τ Τ c

Material limitations for primary seismic elements Dissemination of information for training Lisbon 10-11 February 2011 13 Ductility Class DC L (Low) DC M (Medium) DC H (High) Concrete grade No limit C16/20 C16/20 Steel class per EN B or C B or C only C 1992-1-1, Table C1 Longitudinal bars only ribbed only ribbed Steel overstrength: No limit No limit f yk,0.95 1.25f yk

Basic value, q o, of behaviour factor for regular in elevation concrete buildings in Eurocode 8 Dissemination of information for training Lisbon 10-11 February 2011 14 Lateral-load resisting structural system DC M DC H Inverted pendulum system* 15 1.5 2 Torsionally flexible structural system** 2 3 Uncoupled wall system (> 65% of seismic base shear 3 4 u / 1 resisted by walls; more than half by uncoupled walls) not belonging in one of the categories above Any structural t system other than those above 3 u / 1 4.5 5 u / 1 * at least 50% of total mass is in upper-third of the height, or all energy dissipation takes place at the base of a single element (except one-storey frames w/ all columns connected at the top via beams in both horizontal directions in plan & with max. value of normalized axial load in seismic design situation ν d 0.3). ** at any floor: radius of gyration of floor mass > torsional radius in one or both main horizontal directions (sensitive to torsional response about vertical axis). Buildings irregular in elevation: behaviour factor q = 0.8q o ; g g q q o Wall or wall-equivalent dual systems: q multiplied (further) by (1+a ο )/3 1, (a ο : prevailing wall aspect ratio = ΣH i /Σl wi ).

α u /α 1 in behaviour factor of buildings designed for ductility: due to system redundancy & overstrength Dissemination of information for training Lisbon 10-11 February 2011 15 Normally: á uv α b d u & α 1 from base shear-top displacement curve of a pushover analysis. á 1 V b d α u : seismic action at development of 1st yielding global mechanism; anywhere α 1 : seismic action at 1 st flexural yielding anywhere. α u / α 1 1.5; default values given between een 1 to 1.3 for buildings regular in plan: V bd =design base shear = 1.0 for wall systems w/ just 2 uncoupled walls per horiz. direction; = 11f 1.1 for: one-storey frame or frame-equivalent dual systems, or wall systems w/ > 2 uncoupled walls per direction; = 1.2 for: (one-bay multi-storey frame or frame-equivalent dual systems), wall-equivalent dual systems or coupled wall systems; = 1.3 for: multi-storey multi-bay frame or frame-equivalent dual systems. V b global plastic mechanism for buildings irregular in plan: for buildings irregular in plan: default value = average of default value of buildings regular in plan and 1.0 ä to p

Dissemination of information for training Lisbon 10-11 February 2011 16 Capacity design of members, p y g, against pre-emptive shear failure

I. Beams Dissemination of information for training Lisbon 10-11 February 2011 17 Equilibrium of forces and moments on a beam V 1 = V g+ψq 1 + 1 g+ψq,1 V 2 =V g+ψq,2 - g+ q V V 2 1 1 2 M 1 L M 2 Capacity-design shear in a beam weaker than the columns: V CD,1 =V g+ψq,1 +γ Rd V CD,2 =V g+ψq,2 +γ Rd

Capacity-design shear in beams (weak or strong) - Eurocode 8 Dissemination of information for training Lisbon 10-11 February 2011 18 Eurocode 8: in DC M γ Rd =1.0, in DC H γ Rd =1.2 & reversal of V accounted for, depending on:

II. Columns Dissemination of information for training Lisbon 10-11 February 2011 19 Capacity-design shear in column which is weaker than the beams: Capacity-design shear in (weak or strong) columns - Eurocode 8: Eurocode 8: in DC M γ Rd =1.1 in DC H γ Rd =1.3

III. Walls Dissemination of information for training Lisbon 10-11 February 2011 20 Eurocode 8: Over-design in shear, by multiplying py shear forces from the analysis for the design seismic action, V Ed, by factor ε: DC M walls: DC H squat walls (h w /l w 2): Over-design for flexural overstrength of the base w.r.to analysis M Edo : design moment at base section (from analysis), M Rdo : design flexural resistance at the base section, γ Rd =1.2 DC H slender walls (h w /l w > 2): Over-design for flexural overstrength of the base w.r.to analysis & for increased inelastic shears S e (T): ordinate of elastic response spectrum T C : upper limit T of const. spectral acc. region T 1 : fundamental period

Design shear forces in dual structural systems per Eurocode 8 Dissemination of information for training Lisbon 10-11 February 2011 21 V wall, top>v wall, base/2 design envelope magnified shear diagram 2 3 h w shear diagram 1 h from analysis 3 w V wall, base To account for increase in the upper storey shears due to higher mode inelastic response (after plastic hinging at the base)

Detailing of dissipative zones (flexural plastic hinges) for curvature ductility factor μ φ consistent w/ q-factor Dissemination of information for training Lisbon 10-11 February 2011 22 μ φ =2q o -1 if T 1 T c μ φ =1+2(q o -1)T c /T 1 if T 1 <T c T 1 : fundamental period of building, T c : T at upper limit of constant spectral acceleration region, q o : q-factor unreduced d for irregularity it in elevation (multiplied w/ M Ed /M Rd at a wall base). Derivation: Relation between μ φ & L pl /L s (L pl : plastic hinge length, L s : shear span) & μ δ (: top displacement ductility factor) in buildings staying straight due to walls or strong columns: μ δ =1+3(μ φ -1)L pl /L s (1-0.5L pl /L s ); Relation q-μ δ -T: μ δ = q if T 1 T c, μ δ = 1+(q-1)T 1)T c /T 1 if T 1 <T c ; Relation of L pl & L s for typical RC beams, columns & walls (for EC2 confinement model: ε* cu =0.0035+0.1α ωw ): L pl 0,3L s & for (safety) factor 2: L pl =0,15L s. Then: μ φ 2μ δ -1 For steel B (ε u : 5-7.5%, f t /f y : 1.08-1.15) increase μ φ -demand by 50%

Means for achieving μ φ in plastic hinges Dissemination of information for training Lisbon 10-11 February 2011 23 Base region of members w/ axial load & symmetric reinforcement, ω=ω (columns, ductile walls): Confining reinforcement (for walls: in boundary elements) with (effective) mechanical volumetric ratio: αω wd =30μ φ (ν d +ω ν )ε yd b c /b o -0.035 035 ν d =N d /b c hf cd ; ε yd =fy d /E s ; b c : width of compression zone; b o : width of confined core; ω ν : mechanical ratio of longitudinal web reinforcement =ρ ν f yd,v/f cd DC H columns not meeting the strong-column/weak-beam rule (ΣM Rc<1.3ΣM Rb), should have full confining reinforcement at the end regions of all storeys, not just at the (building) base; DC H strong columns (ΣM Rc >1.3ΣM Rb ) are also provided w/ confining reinforcement for μ φ corresponding to 2/3 of q o at the end regions of every storey. Members w/o axial load & w/ asymmetric reinforcement (beams): Members w/o axial load & w/ asymmetric reinforcement (beams): Max. mechanical ratio of tension steel: ω ω +0.0018/μ φ ε yd

EC8 special feature: two types of dissipative concrete walls Dissemination of information for training Lisbon 10-11 February 2011 24 Ductile walls: Fixed at the base, to prevent rotation there w.r.to rest of structural system. Designed & detailed to dissipate energy only in flexural plastic hinge just above the base. Large lightly-reinforced walls (only for DC M): Walls with horizontal dimension l w 4m, expected to develop limited cracking or inelastic behaviour during design seismic action, but to transform seismic energy to potential energy (uplift of masses) & to energy radiated back into the soil by rigid-body rocking, etc. Due to its dimensions, or lack-of-fixity fixity at base, or connectivity with transverse walls preventing pl. hinge rotation at base, such a wall cannot be designed for energy dissipation in pl. hinge at the base.

Ductile walls: Overdesign in bending Dissemination of information for training Lisbon 10-11 February 2011 25 Strong column/weak beam capacity design is not required in wall or wall-equivalent dual systems (i.e. in those where walls resist >50% of seismic base shear) But: all ductile walls are designed in flexure, to ensure that plastic hinge develops only at the base: Typical moment diagram in a concrete wall from the analysis & linear envelope for its (over-)design in flexure according Eurocode 8

Ductile walls: Design in bending & shear and detailing Dissemination of information for training Lisbon 10-11 February 2011 26 Inelastic action limited to a plastic hinge at the base, so that the cantilever relation between q & μ φ applies: Wall is provided with flexural overstrength above plastic hinge region (linear moment envelope with shift rule); Design in shear for V from analysis, times: 1.5 for DC M [(1.2 M Rd /M Ed ) 2 +0.1(qS e (T c )/S e (T 1 )) 2 ] 1/2 < q for DC H M Ed : design moment at base (from analysis), M Rd : design flexural resistance at base, S e (T): ordinate of elastic response spectrum, T c : upper limit T of const. spectral acc. region T 1 : fundamental period. In plastic hinge zone: boundary elements w/ confining reinforcement having effective mechanical volumetric ratio: αω wd =30μ φ (ν d+ ω )ε yd b c /b o -0.035 over at least the part of the compression zone depth: x u =(ν d +ω v )l w ε yd b c /b o where the strain is between: ε* cu =0.0035+0.1αω w & ε cu =0.0035

Foundation problem of ductile walls Dissemination of information for training Lisbon 10-11 February 2011 27 To form a plastic hinge at the wall base We need fixity there: Very large & heavy footing; adds own weight to N & does not uplift; or Fixity of wall in a box type foundation system: 1. Wall-like deep foundation beams along entire perimeter of the foundation (possibly supplemented w/ interior ones across full length of foundation system) = main foundation elements transferring seismic action effects to the ground. In buildings w/ basement: perimeter foundation beams may double as basement walls. 2. Slab designed to act as rigid diaphragm, at the level of the top flange of perimeter foundation beams (e.g. basement roof). 2. Foundation slab, or two-way tie-beams or foundation beams, at the level of bottom of perimeter foundation beams. (M E ) (V E) Basement Fixity of interior walls provided by couple of horizontal forces between 2 & 3 High reverse shear in part of the wall within the basement

The problem of the foundation of a large wall Dissemination of information for training Lisbon 10-11 February 2011 28 Large l w (=h) large moment at the base (for given axial load) low normalized axial force ν=n/(bhfc)~0.05. Footing of usual size w/ tie-beams of usual size: insufficient: Max normalized moment μ=m/(bh 2 f cd )th that tcan be transferred dto the ground: μ ~0.5ν, i.e. ~wall cracking moment! Impossible to form plastic hinge at the wall base. Wall will uplift & rock as a rigid body. W ELEVATION ~Rigid large walls on large footing: Rocking radiation damping in the soil. φ Rotation of rocking wall: Β θ~s 2 v2 /Βg <<φ=arctan(b/h tot ) θ Very stable nonlinear-elastic behaviour; but hard to address in design H tot

Geometric effects in large walls, due to rocking or plastic hinging Dissemination of information for training Lisbon 10-11 February 2011 29 Rotation of uplifting/rocking wall takes place about a point close to the toe of its footing. Rotation at a wall plastic hinge at the base takes place about a neutral axis which is close to the edge of the wall section. In both cases the centroid of the wall section is raised at every rotation: ti Centre of Gravity (CG) of masses supported by the wall is raised too (temporary) harmless increase in potential energy, instead of damaging deformation energy; Ends of beams framing into the wall move upwards CG beam moments & shears are stabilizing for the wall. beams Wall responds as a stack of rigid blocks, uplifting at the base & at hor. sections that crack & yield (storey bottom). The favourable effects are indirectly taken into account in design q-factor beams neutral axis Plan view: beams framing into wall

Examples of large walls Dissemination of information for training Lisbon 10-11 February 2011 30

Large lightly reinforced concrete walls Dissemination of information for training Lisbon 10-11 February 2011 31 Wall system classified as one of large lightly reinforced walls if, in horizontal direction of interest: At least 2 walls with l w >4 m, supporting together >20% of gravity load above (: sufficient no. of walls / floor area & significant uplift of masses); if just one wall: q=2 Fund. period T 1 <0.5 s for fixity it at the base against rotation ti (: low wall aspect ratio) Systems of large lightly reinforced walls: only DC M (q=3); special (less demanding) di dimensioning i i & detailing. Rationale: For large walls, minimum reinforcement of ductile walls implies: very high cost; flexural overstrength that cannot be transmitted to ground. On the other hand, large lightly reinforced walls: preclude (collapse due to) storey mechanism, minimize nonstructural damage, have shown satisfactory performance in strong EQs. If structural system does not qualify as one of large lightly reinforced walls, all its walls designed & detailed as ductile walls.

Design & detailing of large lightly reinforced walls in EC8 Dissemination of information for training Lisbon 10-11 February 2011 32 Vertical steel tailored to demands due to M & N from analysis Little excess (minimum) reinforcement, in order to minimise flexural overstrength. Shear verification for V from analysis times (1+q)/2 ~2: If so-amplified shear demand is less than (design) shear resistance w/o shear reinforcement: No (minimum) horizontal reinforcement. Reason: Inclined cracking prevented (horizontal cracking & yielding due to flexure mainly at construction joints); If inclined cracking occurs, crack width limited by deformation-controlled nature of response (vs. forcecontrolled non-seismic actions covered in EC2), even w/o min horizontal steel.

Dissemination of information for training Lisbon 10-11 February 2011 33 BEAM-COLUMN JOINTS IN DC H FRAMES

Shear forces in joints Dissemination of information for training Lisbon 10-11 February 2011 34 max possible joint shear force & stress If ΣM Rb < ΣM Rc : Shear forces within joint If b c > b w If b c b w

Shear failures of exterior beam-column joints Left & right: reinforced joints; centre: unreinforced joint Dissemination of information for training Lisbon 10-11 February 2011 35

Principal stress approach for joint shear strength Dissemination of information for training Lisbon 10-11 February 2011 36 Diagonal cracking of unreinforced joint if principal tensile stress due to: joint shear stress, v j & mean vertical compressive stress from column above, ν top f c, exceeds concrete tensile strength, f ct. v j v ju nfc 1 n Eurocode 8: Diagonal cracking of reinforced joint if the principal tensile stress due to: the joint shear stress, v j & the mean vertical compressive stress from column above, ν topf c c,, and the horizontal confining stress due to horiz. joint reinforcement, -ρ jh f yw : exceeds the concrete tensile strength, f ct. jh f yw Joint ultimate shear stress v ju :ifnf c (n: reduction due to transverse tensile strain) reached in principal stress direction: f ct v 2 j top top f c f ct

Alternative approach in EC 8 for joint reinforcement Dissemination of information for training Lisbon 10-11 February 2011 37 Diagonal strut Truss of: horizontal & vertical bars & diagonal compressive field. Interior joints: Exterior joints:

Dissemination of information for training Lisbon 10-11 February 2011 38 OVERVIEW OF DETAILING & DIMENSIONING OF PRIMARY BEAMS, COLUMNS & DUCTILE WALLS IN RC BUILDINGS OF DC H, M or L

Detailing/dimensioning of primary seismic beams (secondary ones: as in DCL) Dissemination of information for training Lisbon 10-11 February 2011 39 DC H DCM DCL critical region length 1.5h w h w Longitudinal bars (L): min, tension side 0.5f ctm /f yk 0.26f ctm /f yk, 0.13% (0) max, critical regions (1) +0.0018f cd /( sy,d f yd ) (1) 0.04 A s,min, top & bottom 2 14 (308mm 2 ) - A s,min, top-span A s,top-supports /4 - A s,min, critical regions bottom (2) 0.5A s,top - A smin s,min,, supports bottom A sbottom-span s,bottom span/4 (0) d bl /h c - bar crossing interior joint (3) 6.25(1 0.8 d ) fctm 7.5(1 0.8νd ) fctm ' (1 0.75 ) f yd ρ' f (1 0.5 ) yd max ρmax - d bl /h c - bar anchored at exterior joint (3) 6.25(1 0.8 d ) (0) NDP (Nationally Determined Parameter) per EC2. Table gives the EC2 recommended value. (1) : value of the curvature ductility factor corresponding to the basic value, q o, of the behaviour factor used in the design (2) The minimum area of bottom steel, A s,min, is in addition to any compression steel that may be needed for the verification of the end section for the ULS in bending under the (absolutely) maximum negative moment from the analysis for the seismic design situation, M Ed. (3) h c : column depth in the direction of the bar, d = N Ed /A c f cd : column axial load ratio for the algebraically minimum axial load in the seismic design situation (compression: positive). fctm f yd 7.5(1 0.8ν ) d f f ctm yd -

Detailing & dimensioning of primary seismic beams (cont d) Dissemination of information for training Lisbon 10-11 February 2011 40 DC H DCM DCL Transverse bars (w): (i) outside critical regions spacing s w 0.75d w 0.08 (f ck (MPa)/f yk (MPa) (0) (ii) in critical regions: d bw 6mm 6d bl, h w, 24d bw, 8d bl, h w, 24d bw, spacing s w 4 4 175mm 225mm -

Detailing & dimensioning of primary seismic beams (cont d) Dissemination of information for training Lisbon 10-11 February 2011 41 DC H DCM DCL Shear design: V Ed, seismic (4) M Rb (4) M from analysis for Rb (4) 1.2 Vo, g 2q Vo, g q l l 2 design seismic cl cl action plus gravity V (5) Rd,max seismic As in EC2: V (5) Rd,max =0.3(1-f ck (MPa)/250)b wo zf cd sin2, 1 cot 2.5 V Rd,s, outside critical regions (5) As in EC2: V Rd,s =b w z w f ywd cot (5), 1 cot 2.5 V Rd,s, critical regions (5) V Rd,s =b w z w f ywd ( =45 o ) As in EC2: V Rd,s=b w z w f ywd cot, 1 cot 2.5 (6) If V If V Emin /V Emax <-0.5: inclined Emax /(2+ )f ctd b w d>1: bars at angle to beam axis, - A with cross-section A s /direction s =0.5V Emax /f yd sin & stirrups for 0.5V Emax (4) At a member end where the moment capacities around the joint satisfy: M Rb > M Rc, M Rb is replaced in the calculation of the design shear force, V Ed, by M Rb ( M Rc / M Rb ) (5) z: internal lever arm, taken equal to 0.9d or to the distance between the tension and the compression reinforcement, d-d 1. (6) V Emax, V E,min are the algebraically maximum and minimum values of V Ed resulting from the sign; V emax is the absolutely largest of the two values, and is taken positive in the calculation of ζ; the sign of V Emin is determined according to whether it is the same as that of V Emax or not.

Detailing/dimensioning of primary seismic columns (secondary ones: as in DCL Dissemination of information for training Lisbon 10-11 February 2011 42 Cross-section section sides, h c,b c DCH DCM DCL 0.25m; - h v /10 if =P /Vh>0.1 (1) critical region length (1) 1.5h c, 1.5b c, 0.6m, l c /5 h c, b c, 0.45m, l c /6 h c, b c Longitudinal bars (L): min 1% 0.1N d /A c f yd, 0.2% (0) max 4% 4% (0) d bl 8mm bars per side 3 2 Spacing between restrained bars 150mm 200mm - distance of unrestrained bar from 150mm (0) Note (0) of Table of beams applies. (1) h v is the distance of the inflection point to the column end further away, for bending within a plane parallel to the side of interest; l c is the column clear length.

Detailing & dimensioning of primary seismic columns (cont d) Dissemination of information for training Lisbon 10-11 February 2011 43 DCH DCM DCL Transverse bars (w): Outside critical regions: d bw 6mm, d bl /4 spacing s w 20d bl, h c, b c, 400mm 12d bl, 0.6h c, 0.6b c, 240mm at lap splices, if d bl >14mm: s w 12d bl, 0.6h c, 0.6b c, 240mm Within critical regions: (2) d (3) bw 6mm, 0.4(f 1/2 yd /f ywd ) d bl 6mm, d bl /4 s w (3),(4) 6d bl, b o /3, 125mm 8d bl, b o /2, 175mm - wd (5) 0.08 - wd (4),(5),(6),(7) 30 * d sy,d b c /b o -0.035 - In critical region at column base: wd 0.12 0.08 - wd (4),(5),(6),(8),(9) 30 d sy,d b c /b o -0.035 - (2) For DCM: Ιf q 2 used in the design, the transverse reinforcement in critical regions of columns with axial load ratio d not greater than 0.2 may follow the rules applying to DCL columns. (3) For DCH: In the two lower storeys of the building, the requirements on d bw, s w apply over a distance from the end section not less than 1.5 times the critical region height. (4) c denotes full concrete section; o the confined core (to centreline of perimeter hoop); b o is the smallest side of this core. (5) wd : volume ratio of confining hoops to confined core (to centreline of perimeter hoop) times f yd /f cd

Detailing & dimensioning of primary seismic columns (cont d) DCH DCM DCL Dissemination of information for training Lisbon 10-11 February 2011 Transverse bars (w): 44 Outside critical regions: d bw 6mm, d bl /4 spacing s w 20d bl, h c, b c, 400mm 12d bl,, 0.6h c c, 0.6b c c, 240mm at lap splices, if d bl >14mm: s w 12d bl, 0.6h c, 0.6b c, 240mm Within critical regions: (2) d bw (3) 6mm, 0.4(f yd /f ywd ) 1/2 d bl 6mm, d bl /4 s w (3),(4) 6d bl, b o /3, 125mm 8d bl, b o /2, 175mm - wd (5) 0.08 - wd (4),(5),(6),(7) 30 * d sy,d b c /b o -0.035 - In critical region at column base: wd 0.12 0.08 - (4),(5),(6),(8),(9) wd 30 d sy,d b c /b o -0.035 035 - (6) : confinement effectiveness factor, = s n ; where s =(1-s/2b o )(1-s/2h o ) for hoops, s =(1-s/2b o ) for spirals; n =1 for circular hoops, n =1-{b o /((n h -1)h o )+h o /((n b -1)b o )}/3 for rect. hoops with n b legs parallel to side of the core with length b o and n h legs parallel to the one with length h o. (7) For DCH: at column ends protected from plastic hinging by capacity design of the column, * is the curvature ductility factor corresponding to 2/3 of the basic value q o of the behaviour factor used in the design; at column ends where plastic hinging is not prevented due to the exemptions in Note (10) below, * is the full value corresponding to q o ; sy,d =f yd /Ε s. (8) Note (1) of the Beams Table applies. (9) For DCH: Requirement applies also in the critical regions at the ends of columns where plastic hinging is not prevented, because of the exemptions in Note (10) below.

Detailing & dimensioning of primary seismic columns (cont d) Dissemination of information for training Lisbon 10-11 February 2011 45 DCH DCM DCL 1.3 M Capacity design check at beam- Rb M Rc (10) No moment in transverse direction of column joints: column - Verification for M x -M y -N: Truly biaxial, or uniaxial with (M z /0.7, N), (M y /0.7, N) Axial load ratio d =N Ed /A c f cd 0.55 0.65 - Shear design: V Ed seismic (11) ends ends M Rc (11) M from analysis for Rc (11) 1.3 1.1 design seismic lcl lcl action plus gravity (12), (13) V Rd,max seismic i As in EC2: V Rd,max =0.3(1-f ck (MPa)/250)b wo zf cd sin2, 1 cot 2.5 V Rd,s seismic (12), (13), (14) As in EC2: V Rd,s =b w z w f ywd cot +N Ed (h-x)/l (13) cl, 1 cot 2.5 (10) The capacity design rule does not need to be met at beam-column joints: (a) of the top floor, (b) of the ground storey in two-storey buildings with axial load ratio d 0.3 3 in all columns, (c) if shear walls resist 50% of base shear parallel to the plane of the frame (wall buildings or wallequivalent dual), or (d) in one-out-of-four columns of plane frames with columns of similar size. (11) At a member end where the moment capacities around the joint satisfy: M Rb < M Rc, M Rc is replaced by M Rc ( M Rb / M Rc ). (12) z is the internal lever arm, equal to 0.9d or to the distance between the tension and the compression reinforcement, d-d 1. (13) The axial load, N Ed, and its normalized value, d, are taken with their most unfavourable values for the shear verification in the seismic design situation (considering both the demand and the capacity). (14) x is the neutral axis depth at the end section in the ULS of bending with axial load.

Detailing & dimensioning of ductile walls Dissemination of information for training Lisbon 10-11 February 2011 46 DCH DCM DCL Web thickness, b wo max(150mm, h storey /20) - max(l critical region length, h w, H w /6) (1) cr min(2l w, h storey ) if wall 6 storeys - min(2l w w, 2h storey) ) if wall > 6 storeys (0) Notes (0) of the Beam & Column Tables apply. (1) l w is the long side of the rectangular wall section or rectangular part thereof; H w is the total height of fthe wall; h storey is the storey height. ht

Detailing & dimensioning of ductile walls (cont d) Dissemination of information for training Lisbon 10-11 February 2011 47 DCH DCM DCL Boundary elements: a) in critical region: - length l c from edge 0.15l w, 1.5b w, length over which c > 0.0035 - - thickness b w over l c 0.2m; h st /15 if l c max(2b w, l w /5), h st /10 if l c >max(2b w, l w /5) - - vertical reinforcement: min over A c =l c b w 0.5% 0.2% (0 ) max over A c 4% (0) - confining hoops (w) (2 ) : d bw 6mm, 0.4(f yd /f ywd ) 1/2 d bl 6mm, in the part of the spacing s w (3) 6d bl, b o /3, 125m m 8d bl, b o /2, 175mm section where L >2%: wd (2 ) 0.12 0.08 as over the rest of the wd (3 ),(4 ) 30 ( d + ) sy,d b w /b o -0.035 wall (case b, below) In parts of the section where c >0.2% : v,min = 0.5%; In parts of the section where L >2% : - distance of unrestrained bar in compression zone from nearest restrained bar b) over the rest of the wall 150m m; height: - hoops with d bw max(6mm, d bl /4) & spacing s w min(12d bl, 0.6b wo, 240mm) (0 ) up to a distance of 4b w above or belo w fl oor b eams or slabs, or s w min(20d bl, b wo, 400m m) (0 ) beyond that distance (2) For DC M: If in the seismic design situation d =N Ed /A c f cd 0.15, the DCL rules may be applied for the boundary elements; these rules apply also if d 0.2 but the q-value used in the design is of 85% of the value allowed when the DC M confining reinforcement is used in boundary elements. (3) Notes (4), (5), (6) of the columns Table apply for the confined core of boundary elements. (4) is the curvature ductility factor corresponding to the product of q o andthe ratio M Edo /M Rdo at the base of the wall; sy,d = f yd /Ε s, d is the mechanical ratio of the vertical web reinforcement.

Detailing & dimensioning of ductile walls (cont d) Dissemination of information for training Lisbon 10-11 February 2011 48 DCH DCM DCL Web: - vertical bars (v): v,min wherever c >0.2%: 0.5%; elsewhere 0.2% 0.2% (0) v,max 4% d b 8mm - d bv b wo /8 - spacing s v min(25d bv, 250mm) min(3b wo, 400mm) - horizontal bars: hmin 0.2% max(0.1%, 0.25 v ) (0) d bh 8mm - d bh b wo /8 - spacing s h min(25d bh, 250mm) 400mm axial load ratio d = N Ed /A c f cd 0.35 0.4 - Design moments M Ed : If H w /l w 2, design moments from linear envelope of from analysis for maximum moments M Ed from analysis for the design seismic seismic design situation, shifted up by the tension action & gravity shift a l (0) Notes (0) of the Beam & Column Tables apply.

Detailing & dimensioning of ductile walls (cont d) Dissemination of information for training Lisbon 10-11 February 2011 49 DCH DCM DCL Shear design: Design shear force V Ed = shear force V Ed from the analysis for the design seismic action, times factor : if H (5) w /l w 2 : =1.2M Rdo /M Edo q if H w /l w >2 (5), (6) : =1.5 =1.0 2 2 M S T ε Rdo q e C 1.2 q M 0.1 Edo Se T 1 Design shear force in walls fd from analysis for of dual systems with 0.75z 1 H w /l w >2, for z between H w /3 1.5 z H a s V ( ) (0) 1.5 w Ed z εved εved design seismic action H 4 3 and H w : (7) w Hw & gravity V Rd,max outside critical region As in EC2: V Rd,max =0.3(1-f ck (MPa)/250)b wo (0.8l w )f cd sin2, with 1 cot 2.5 V Rd,max in critical region 40% of EC2 value As in EC2 (5) M edo : moment at the wall base from the analysis for the seismic design situation; (6) M Rdo : design moment resistance at the wall base for the axial force N Ed from the same analysis S e (T 1 ): value of the elastic spectral acceleration at the period of the fundamental mode in the horizontal direction (closest to that) of the wall shear force being multiplied by ; S e (T c ): spectral acceleration at the corner period T C of the elastic spectrum. (7) A dual structural system is one where walls resist between 35 and 65% of the seismic base shear in the direction of the wall shear force considered; z is distance from the base of the wall.

Detailing & dimensioning of ductile walls (cont d) Dissemination of information for training Lisbon 10-11 February 2011 50 DCH DCM DCL Shear design: V Rd,s in critical region; web reinforcement ratios: h, (i) if s =M Ed /V Ed l w 2 : = v,min, h from V Rd,s : V Rd,s =b wo (0.8l w ) h f ywd (ii) if s <2: h from V Rd,s : (8) V Rd,s =V Rd,c +b wo s (0.75l w ) h f yhd v from: (9) f yvd h f yhd -N Ed /(0.8l w b wo ) Resistance to sliding shear: via bars with total area A si at angle to the horizontal (10) v,min at construction joints (9),(11) V Rd,s =A si f yd cos + A sv min(0.25f yd, 1.3 (f yd f cd ))+ 0.3(1-f ck (MPa)/250)b wo xf cd 0.0025, f 1.3 f yd ctd 1.5 N f A cd Ed c f yd As in EC2: V Rd,s =b wo (0.8l w ) h f ywd cot, 1 cot 2.5 As in EC2: V Rd,s =b wo (0.8l w ) h f ywd cot, 1 cot 2.5 (8) If b w & d in m, f cd in MPa, ρ L : tensile reinforcement ratio and N Εd in kn, V Rd,c (in kn) is given by:.. N 1 / 3 0 2 1/ 6 0 2 1/ 3 Ed V Rd,c max 180 100 1, 35 1 f cd fcd. bwd d 1 d 0 15 Ac N ed >0 for compression; min. value from analysis for seismic design situation; V Rd, =0 for tension (9) N Ed >0 for compression; use its minimum value from the analysis for the seismic design situation (10) A sv : total area of web vert. bars & of additional vert. bars in boundary elements for shear sliding (11) f ctd =f ctκ 005 / c : design value of (5%-fractile) tensile strength of concrete. -

RC Building Design Example Dissemination of information for training Lisbon 10-11 February 2011 51 Example design of beams in flexure

Beam C Dissemination of information for training Lisbon 10-11 February 2011 52 1 2 3 4 5 6 A B SLAB C TYPICAL PLAN D

Beam C storey 6 Dissemination of information for training Lisbon 10-11 February 2011 53 * STOREY: 6 * BEAMS: 10 11 12 13 14 * Concrete: C25 - Long. Reinforcement: S500 - Stirrups: S500 - Cover: 35(mm) * GEOMETRY - BENDING MOMENTS MSd - LONGITUDINAL REINFORCEMENT Beam: 10 Length l: 5.50m X-section 50m X L Depth h: 0.50m Width bw: 0.25m JOINT GEOMETRY - SHEAR FORCES - VERIFICATION IN SHEAR +-----+-----+---------+-------------+-------------+-------------+-------------+ L end: 10 Top flange thickness (m): 0.18 (L end) 0.18 (centre) 0.18 (R end) Joint Max Φ J width J hor. shear J hor. shear J hor. steel J ver. steel R end: 10 Bot flange thickness (m): 0.00 (L end) - (centre) 0.00 (R end) bj Vjh strength area Ash area Asv +-----+-(mm)+---(m)---+----(kn)-----+----(kn)-----+----(mm2)----+----(mm2)----+ Location Effect. max MSd Required Beam bars Provided Flexural 1 12 0.40 0. 807. 0. 0. fl width steel area Contin Addit steel area capacity 2 26 0.30 0. 1749. 0. 0. -----------+--(m)---+--(knm)---+---(mm2)---+-------------+--(mm2)---+-(knm)-- 3 26 0.30 0. 1765. 0. 0. L end top 0.25 85.7 467. 3Φ12 -- 486. 88.9 4 26 0.30 0. 1765. 0. 0. L end bot. 0.43 32.4 291. 3Φ12 -- 339. 64.4 5 26 0.30 0. 1749. 0. 0. midspan 1.27 38.7 291. 3Φ12 -- 339. 65.4 6 12 0.40 0. 807. 0. 0. R end top 0.25 101.2 558. 3Φ12 -- 526. 95.7 +-----+-----+---------+-------------+-------------+-------------+-------------+ R end bot. 0.61 45.3 291. 3Φ12 -- 339. 64.8 Note: Top reinforcement includes 250mm2 /m of effective slab width Beam: 11 Length l: 5.30m X-section L Depth h: 0.50m Width bw: 0.25m L end: 11 Top flange thickness (m): 0.18 (L end) 0.18 (centre) 0.18 (R end) R end: 11 Bot flange thickness (m): 0.00 (L end) - (centre) 0.00 (R end) Location Effect. max MSd Required Beam bars Provided Flexural fl width steel area Contin Addit steel area capacity -----------+--(m)---+--(knm)---+---(mm2)---+-------------+--(mm2)---+-(knm)-- + (knm) + (mm2) + + (mm2) + (knm) L end top 0.25 117.0 653. 3Φ12 -- 526. 95.7 L end bot. 0.61 56.6 327. 3Φ12 -- 339. 64.8 midspan 1.09 27.3 291. 3Φ12 -- 339. 65.3 R end top 0.25 124.9 702. 3Φ12 1Φ14 679. 121.3 R end bot. 0.61 46.0 351. 3Φ12 -- 339. 64.8 Note: Top reinforcement includes 250mm2 /m of effective slab width + Beam: 12 Length l: 5.30m X-section L Depth h: 0.50m Width bw: 0.25m L end: 12 Top flange thickness (m): 0.18 (L end) 0.18 (centre) 0.18 (R end) R end: 12 Bot flange thickness (m): 0.00 (L end) - (centre) 0.00 (R end) Location Effect. max MSd Required Beam bars Provided Flexural fl width steel area Contin Addit steel area capacity -----------+--(m)---+--(knm)---+---(mm2)---+-------------+--(mm2)---+-(knm)-- L end top 0.25 120.9 677. 3Φ12 1Φ14 679. 121.3 L end bot. 0.61 50.6 339. 3Φ12 -- 339. 64.8 midspan 1.09 25.1 291. 3Φ12 -- 339. 65.3 R end top 0.25 120.9 677. 3Φ12 1Φ14 679. 121.3 R end bot. 0.61 50.6 339. 3Φ12 -- 339. 64.8 Note: Top reinforcement includes 250mm2 /m of effective slab width

Beam C storey 5 Dissemination of information for training Lisbon 10-11 February 2011 54 * STOREY: 5 * BEAMS: 10 11 12 13 14 * Concrete: C25 - Long. Reinforcement: S500 - Stirrups: S500 - Cover: 35(mm) * GEOMETRY - BENDING MOMENTS MSd - LONGITUDINAL REINFORCEMENT Beam: 10 Length l: 5.50m X-section L Depth h: 0.50m Width bw: 0.25m JOINT GEOMETRY - SHEAR FORCES - VERIFICATION IN SHEAR +-----+-----+---------+-------------+-------------+-------------+-------------+ L end: 10 Top flange thickness (m): 0.18 (L end) 0.18 (centre) 0.18 (R end) Joint Max Φ J width J hor. shear J hor. shear J hor. steel J ver. steel R end: 10 Bot flange thickness (m): 0.00 (L end) - (centre) 0.00 (R end) bj Vjh strength area Ash area Asv +-----+-(mm)+---(m)---+----(kn)-----+----(kn)-----+----(mm2)----+----(mm2)----+ Location Effect. max MSd Required Beam bars Provided Flexural 1 12 0.40 0. 764. 0. 0. fl width steel area Contin Addit steel area capacity 2 28 0.30 0. 1639. 0. 0. -----------+--(m)---+--(knm)---+---(mm2)---+-------------+--(mm2)---+-(knm)-- 3 26 0.30 0. 1673. 0. 0. L end top 0.25 138.5 787. 3Φ12 1Φ12 639. 114.7 4 26 0.30 0. 1673. 0. 0. L end bot. 0.43 58.7 393. 3Φ12 1Φ12 452. 85.1 5 28 0.30 0. 1639. 0. 0. midspan 1.27 33.1 291. 3Φ12 -- 339. 65.4 6 12 0.40 0. 764. 0. 0. R end top 0.25 133.2 754. 3Φ12 1Φ16 727. 128.9 +-----+-----+---------+-------------+-------------+-------------+-------------+ R end bot. 0.61 89.0 469. 3Φ12 1Φ20 653. 122.9 Note: Top reinforcement includes 250mm2 /m of effective slab width + Beam: 11 Length l: 5.30m X-section L Depth h: 0.50m Width bw: 0.25m L end: 11 Top flange thickness (m): 0.18 (L end) 0.18 (centre) 0.18 (R end) R end: 11 Bot flange thickness (m): 0.00 (L end) - (centre) 0.00 (R end) Location Effect. max MSd Required Beam bars Provided Flexural fl width steel area Contin Addit steel area capacity -----------+--(m)---+--(knm)---+---(mm2)---+-------------+--(mm2)---+-(knm)-- + (knm) + (mm2) + + (mm2) + (knm) L end top 0.25 153.4 883. 3Φ12 2Φ16 928. 160.2 L end bot. 0.61 94.6 499. 3Φ12 1Φ20 653. 122.9 midspan 1.09 27.2 291. 3Φ12 -- 339. 65.3 R end top 0.25 163.9 952. 3Φ12 2Φ16 928. 160.2 R end bot. 0.61 83.1 476. 3Φ12 1Φ20 653. 122.9 Note: Top reinforcement includes 250mm2 /m of effective slab width + Beam: 12 Length l: 5.30m X-section L Depth h: 0.50m Width bw: 0.25m L end: 12 Top flange thickness (m): 0.18 (L end) 0.18 (centre) 0.18 (R end) R end: 12 Bot flange thickness (m): 0.00 (L end) - (centre) 0.00 (R end) Location Effect. max MSd Required Beam bars Provided Flexural fl width steel area Contin Addit steel area capacity -----------+--(m)---+--(knm)---+---(mm2)---+-------------+--(mm2)---+-(knm)-- L end top 0.25 159.4 922. 3Φ12 2Φ16 928. 160.2 L end bot. 0.61 89.9 473. 3Φ12 1Φ20 653. 122.9 midspan 1.09 25.8 291. 3Φ12 -- 339. 65.3 R end top 0.25 159.4 922. 3Φ12 2Φ16 928. 160.2 R end bot. 0.61 89.9 473. 3Φ12 1Φ20 653. 122.9 Note: Top reinforcement includes 250mm2 /m of effective slab width

Beam C storey 4 Dissemination of information for training Lisbon 10-11 February 2011 55 * STOREY: 4 * BEAMS: 10 11 12 13 14 * Concrete: C25 - Long. Reinforcement: S500 - Stirrups: S500 - Cover: 35(mm) * GEOMETRY - BENDING MOMENTS MSd - LONGITUDINAL REINFORCEMENT Beam: 10 Length l: 5.50m X-section L Depth h: 0.50m Width bw: 0.25m JOINT GEOMETRY - SHEAR FORCES - VERIFICATION IN SHEAR +-----+-----+---------+-------------+-------------+-------------+-------------+ L end: 10 Top flange thickness (m): 0.18 (L end) 0.18 (centre) 0.18 (R end) Joint Max Φ J width J hor. shear J hor. shear J hor. steel J ver. steel R end: 10 Bot flange thickness (m): 0.00 (L end) - (centre) 0.00 (R end) bj Vjh strength area Ash area Asv +-----+-(mm)+---(m)---+----(kn)-----+----(kn)-----+----(mm2)----+----(mm2)----+ Location Effect. max MSd Required Beam bars Provided Flexural 1 12 0.40 0. 719. 0. 0. fl width steel area Contin Addit steel area capacity 2 28 0.30 0. 1522. 0. 0. -----------+--(m)---+--(knm)---+---(mm2)---+-------------+--(mm2)---+-(knm)-- 3 28 0.30 0. 1577. 0. 0. L end top 0.25 138.4 786. 3Φ12 1Φ12 687. 122.4 4 28 0.30 0. 1577. 0. 0. L end bot. 0.43 63.8 393. 3Φ12 1Φ12 452. 85.1 5 28 0.30 0. 1522. 0. 0. midspan 1.27 33.9 291. 3Φ12 -- 339. 65.4 6 12 0.40 0. 719. 0. 0. R end top 0.25 138.1 785. 3Φ12 1Φ18 780. 137.4 +-----+-----+---------+-------------+-------------+-------------+-------------+ R end bot. 0.61 90.8 478. 3Φ12 1Φ20 653. 122.9 Note: Top reinforcement includes 250mm2 /m of effective slab width + Beam: 11 Length l: 5.30m X-section L Depth h: 0.50m Width bw: 0.25m L end: 11 Top flange thickness (m): 0.18 (L end) 0.18 (centre) 0.18 (R end) R end: 11 Bot flange thickness (m): 0.00 (L end) - (centre) 0.00 (R end) Location Effect. max MSd Required Beam bars Provided Flexural fl width steel area Contin Addit steel area capacity -----------+--(m)---+--(knm)---+---(mm2)---+-------------+--(mm2)---+-(knm)-- + (knm) + (mm2) + + (mm2) + (knm) L end top 0.25 157.9 912. 3Φ12 2Φ18 1034. 182.6 L end bot. 0.61 97.8 517. 3Φ12 1Φ20 653. 122.9 midspan 1.09 27.2 291. 3Φ12 -- 339. 65.3 R end top 0.25 167.0 973. 3Φ12 2Φ16 928. 160.2 R end bot. 0.61 87.3 487. 3Φ12 1Φ20 653. 122.9 Note: Top reinforcement includes 250mm2 /m of effective slab width + Beam: 12 Length l: 5.30m X-section L Depth h: 0.50m Width bw: 0.25m L end: 12 Top flange thickness (m): 0.18 (L end) 0.18 (centre) 0.18 (R end) R end: 12 Bot flange thickness (m): 0.00 (L end) - (centre) 0.00 (R end) Location Effect. max MSd Required Beam bars Provided Flexural fl width steel area Contin Addit steel area capacity -----------+--(m)---+--(knm)---+---(mm2)---+-------------+--(mm2)---+-(knm)-- L end top 0.25 162.8 945. 3Φ12 2Φ16 928. 160.2 L end bot. 0.61 93.2 491. 3Φ12 1Φ20 653. 122.9 midspan 1.09 25.7 291. 3Φ12 -- 339. 65.3 R end top 0.25 162.8 945. 3Φ12 2Φ16 928. 160.2 R end bot. 0.61 93.2 491. 3Φ12 1Φ20 653. 122.9 Note: Top reinforcement includes 250mm2 /m of effective slab width

Beam C storey 3 Dissemination of information for training Lisbon 10-11 February 2011 56 * STOREY: 3 * BEAMS: 10 11 12 13 14 * Concrete: C25 - Long. Reinforcement: S500 - Stirrups: S500 - Cover: 35(mm) * GEOMETRY - BENDING MOMENTS MSd - LONGITUDINAL REINFORCEMENT Beam: 10 Length l: 5.50m X-section L Depth h: 0.50m Width bw: 0.25m JOINT GEOMETRY - SHEAR FORCES - VERIFICATION IN SHEAR +-----+-----+---------+-------------+-------------+-------------+-------------+ L end: 10 Top flange thickness (m): 0.18 (L end) 0.18 (centre) 0.18 (R end) Joint Max Φ J width J hor. shear J hor. shear J hor. steel J ver. steel R end: 10 Bot flange thickness (m): 0.00 (L end) - (centre) 0.00 (R end) bj Vjh strength area Ash area Asv +-----+-(mm)+---(m)---+----(kn)-----+----(kn)-----+----(mm2)----+----(mm2)----+ Location Effect. max MSd Required Beam bars Provided Flexural 1 12 0.40 0. 670. 0. 0. fl width steel area Contin Addit steel area capacity 2 28 0.30 0. 1396. 0. 0. -----------+--(m)---+--(knm)---+---(mm2)---+-------------+--(mm2)---+-(knm)-- 3 28 0.30 0. 1475. 0. 0. L end top 0.25 139.8 795. 3Φ12 3Φ12 825. 144.4 4 28 0.30 0. 1475. 0. 0. L end bot. 0.43 66.7 398. 3Φ12 1Φ12 452. 85.1 5 28 0.30 0. 1396. 0. 0. midspan 1.27 33.6 291. 3Φ12 -- 339. 65.4 6 12 0.40 0. 670. 0. 0. R end top 0.25 141.7 807. 3Φ12 1Φ18 780. 137.4 +-----+-----+---------+-------------+-------------+-------------+-------------+ R end bot. 0.61 92.2 486. 3Φ12 1Φ20 653. 122.9 Note: Top reinforcement includes 250mm2 /m of effective slab width + Beam: 11 Length l: 5.30m X-section L Depth h: 0.50m Width bw: 0.25m L end: 11 Top flange thickness (m): 0.18 (L end) 0.18 (centre) 0.18 (R end) R end: 11 Bot flange thickness (m): 0.00 (L end) - (centre) 0.00 (R end) Location Effect. max MSd Required Beam bars Provided Flexural fl width steel area Contin Addit steel area capacity -----------+--(m)---+--(knm)---+---(mm2)---+-------------+--(mm2)---+-(knm)-- + (knm) + (mm2) + + (mm2) + (knm) L end top 0.25 161.0 933. 3Φ12 2Φ18 1034. 182.6 L end bot. 0.61 100.1 529. 3Φ12 1Φ20 653. 122.9 midspan 1.09 27.1 291. 3Φ12 -- 339. 65.3 R end top 0.25 169.4 989. 3Φ12 2Φ16 928. 160.2 R end bot. 0.61 90.4 494. 3Φ12 1Φ20 653. 122.9 Note: Top reinforcement includes 250mm2 /m of effective slab width + Beam: 12 Length l: 5.30m X-section L Depth h: 0.50m Width bw: 0.25m L end: 12 Top flange thickness (m): 0.18 (L end) 0.18 (centre) 0.18 (R end) R end: 12 Bot flange thickness (m): 0.00 (L end) - (centre) 0.00 (R end) Location Effect. max MSd Required Beam bars Provided Flexural fl width steel area Contin Addit steel area capacity -----------+--(m)---+--(knm)---+---(mm2)---+-------------+--(mm2)---+-(knm)-- L end top 0.25 165.4 962. 3Φ12 2Φ16 928. 160.2 L end bot. 0.61 95.8 506. 3Φ12 1Φ20 653. 122.9 midspan 1.09 25.7 291. 3Φ12 -- 339. 65.3 R end top 0.25 165.4 962. 3Φ12 2Φ16 928. 160.2 R end bot. 0.61 95.8 506. 3Φ12 1Φ20 653. 122.9 Note: Top reinforcement includes 250mm2 /m of effective slab width

Beam C storey 2 Dissemination of information for training Lisbon 10-11 February 2011 57 * STOREY: 2 * BEAMS: 10 11 12 13 14 * Concrete: C25 - Long. Reinforcement: S500 - Stirrups: S500 - Cover: 35(mm) * GEOMETRY - BENDING MOMENTS MSd - LONGITUDINAL REINFORCEMENT Beam: 10 Length l: 5.50m X-section L Depth h: 0.50m Width bw: 0.25m JOINT GEOMETRY - SHEAR FORCES - VERIFICATION IN SHEAR +-----+-----+---------+-------------+-------------+-------------+-------------+ L end: 10 Top flange thickness (m): 0.18 (L end) 0.18 (centre) 0.18 (R end) Joint Max Φ J width J hor. shear J hor. shear J hor. steel J ver. steel R end: 10 Bot flange thickness (m): 0.00 (L end) - (centre) 0.00 (R end) bj Vjh strength area Ash area Asv +-----+-(mm)+---(m)---+----(kn)-----+----(kn)-----+----(mm2)----+----(mm2)----+ Location Effect. max MSd Required Beam bars Provided Flexural 1 12 0.40 0. 621. 0. 0. fl width steel area Contin Addit steel area capacity 2 30 0.30 0. 1259. 0. 0. -----------+--(m)---+--(knm)---+---(mm2)---+-------------+--(mm2)---+-(knm)-- 3 30 0.30 0. 1368. 0. 0. L end top 0.25 135.2 766. 3Φ12 1Φ12 740. 131.0 4 30 0.30 0. 1368. 0. 0. L end bot. 0.43 63.7 383. 3Φ12 1Φ12 452. 85.1 5 30 0.30 0. 1259. 0. 0. midspan 1.27 33.2 291. 3Φ12 -- 339. 65.4 6 12 0.40 0. 621. 0. 0. R end top 0.25 138.6 787. 3Φ12 1Φ18 780. 137.4 +-----+-----+---------+-------------+-------------+-------------+-------------+ R end bot. 0.61 86.3 454. 3Φ12 1Φ20 653. 122.9 Note: Top reinforcement includes 250mm2 /m of effective slab width + Beam: 11 Length l: 5.30m X-section L Depth h: 0.50m Width bw: 0.25m L end: 11 Top flange thickness (m): 0.18 (L end) 0.18 (centre) 0.18 (R end) R end: 11 Bot flange thickness (m): 0.00 (L end) - (centre) 0.00 (R end) Location Effect. max MSd Required Beam bars Provided Flexural fl width steel area Contin Addit steel area capacity -----------+--(m)---+--(knm)---+---(mm2)---+-------------+--(mm2)---+-(knm)-- + (knm) + (mm2) + + (mm2) + (knm) L end top 0.25 156.1 901. 3Φ12 2Φ18 1034. 182.6 L end bot. 0.61 94.0 496. 3Φ12 1Φ20 653. 122.9 midspan 1.09 27.1 291. 3Φ12 -- 339. 65.3 R end top 0.25 163.4 949. 3Φ12 2Φ16 928. 160.2 R end bot. 0.61 85.6 474. 3Φ12 1Φ20 653. 122.9 Note: Top reinforcement includes 250mm2 /m of effective slab width + Beam: 12 Length l: 5.30m X-section L Depth h: 0.50m Width bw: 0.25m L end: 12 Top flange thickness (m): 0.18 (L end) 0.18 (centre) 0.18 (R end) R end: 12 Bot flange thickness (m): 0.00 (L end) - (centre) 0.00 (R end) Location Effect. max MSd Required Beam bars Provided Flexural fl width steel area Contin Addit steel area capacity -----------+--(m)---+--(knm)---+---(mm2)---+-------------+--(mm2)---+-(knm)-- L end top 0.25 159.8 925. 3Φ12 2Φ16 928. 160.2 L end bot. 0.61 90.3 476. 3Φ12 1Φ20 653. 122.9 midspan 1.09 25.8 291. 3Φ12 -- 339. 65.3 R end top 0.25 159.8 925. 3Φ12 2Φ16 928. 160.2 R end bot. 0.61 90.3 476. 3Φ12 1Φ20 653. 122.9 Note: Top reinforcement includes 250mm2 /m of effective slab width