CONSULTING Engineering Calculation Sheet

Σχετικά έγγραφα
APPENDIX 1: Gravity Load Calculations. SELF WEIGHT: Slab: 150psf * 8 thick slab / 12 per foot = 100psf ROOF LIVE LOAD:

MECHANICAL PROPERTIES OF MATERIALS

Περίπτωση Μελέτης Θαλάσσιας Κατασκευής με χρήση λογισμικού και με βάση Κώδικες (Compliant Tower) (8.1.10)

STRUCTURAL CALCULATIONS FOR SUSPENDED BUS SYSTEM SEISMIC SUPPORTS SEISMIC SUPPORT GUIDELINES

Ingenieurbüro Frank Blasek - Beratender Ingenieur Am Kohlhof 10, Osterholz-Scharmbeck Tel: 04791/ Fax: 04791/

Ingenieurbüro Frank Blasek - Beratender Ingenieur Am Kohlhof 10, Osterholz-Scharmbeck Tel: 04791/ Fax: 04791/

Figure 1 - Plan of the Location of the Piles and in Situ Tests

Operational Programme Education and Lifelong Learning. Continuing Education Programme for updating Knowledge of University Graduates:

Analyse af skrå bjælke som UPE200

5.0 DESIGN CALCULATIONS

Introduction to Theory of. Elasticity. Kengo Nakajima Summer

(Mechanical Properties)

DETERMINATION OF DYNAMIC CHARACTERISTICS OF A 2DOF SYSTEM. by Zoran VARGA, Ms.C.E.

DERIVATION OF MILES EQUATION FOR AN APPLIED FORCE Revision C


MasterSeries MasterPort Lite Sample Output

Delhi Noida Bhopal Hyderabad Jaipur Lucknow Indore Pune Bhubaneswar Kolkata Patna Web: Ph:

BEHAVIOR OF MASSIVE EARTH RETAINING WALLS UNDER EARTHQUAKE SHAKING Comparisons to EC-8 Provisions

Dr. D. Dinev, Department of Structural Mechanics, UACEG

Α ιθ EL. 3. Κα ασ ασ ής: fischerwerke GmbH & Co. KG, Klaus-Fischer-Straße 1, Waldachtal, α ία. Tumlingen,

Answers to practice exercises

Monolithic Crystal Filters (M.C.F.)

SOLUTIONS TO MATH38181 EXTREME VALUES AND FINANCIAL RISK EXAM

Homework 8 Model Solution Section

Τοίχοι Ωπλισμένης Γής: υναμική Ανάλυση Πειράματος Φυγοκεντριστή. Reinforced Soil Retaining Walls: Numerical Analysis of a Centrifuge Test

Consolidated Drained

First Sensor Quad APD Data Sheet Part Description QA TO Order #

TRIAXIAL TEST, CORPS OF ENGINEERS FORMAT

ΑΝΩΤΑΤΗ ΣΧΟΛΗ ΠΑΙ ΑΓΩΓΙΚΗΣ ΚΑΙ ΤΕΧΝΟΛΟΓΙΚΗΣ ΕΚΠΑΙ ΕΥΣΗΣ ΠΑΡΑΔΟΤΕΟ ΕΠΙΣΤΗΜΟΝΙΚΗ ΕΡΓΑΣΙΑ ΣΕ ΔΙΕΘΝΕΣ ΕΠΙΣΤΗΜΟΝΙΚΟ ΠΕΡΙΟΔΙΚΟ

Project: Brimsmore, Ye... Job no: C08127 Designed By kristian Checked By Network W Network Design Table for OUTFALL B.SWS

ΕΘΝΙΚΟ ΜΕΤΣΟΒΙΟ Π0ΛΥΤΕΧΝΕΙΟ ΣΧΟΛΗ ΠΟΛΙΤΙΚΩΝ ΜΗΧΑΝΙΚΩΝ ΤΟΜΕΑΣ ΟΜΟΣΤΑΤΙΚΗΣ ΕΡΓΑΣΤΗΡΙΟ ΜΕΤΑΛΛΙΚΩΝ ΚΑΤΑΣΚΕΥΩΝ

; +302 ; +313; +320,.

Prepolarized Microphones-Free Field

Aquinas College. Edexcel Mathematical formulae and statistics tables DO NOT WRITE ON THIS BOOKLET

D28 1-1/4" PIPE x 42-1/2" HIGH RAIL WITHOUT BOTTOM RAIL

Θωμάς ΣΑΛΟΝΙΚΙΟΣ 1, Χρήστος ΚΑΡΑΚΩΣΤΑΣ 2, Βασίλειος ΛΕΚΙΔΗΣ 2, Μίλτων ΔΗΜΟΣΘΕΝΟΥΣ 1, Τριαντάφυλλος ΜΑΚΑΡΙΟΣ 3,

ADVANCED STRUCTURAL MECHANICS

Μέτρηση Δυναμικών Χαρακτηριστικών Μόνωση Ταλαντώσεων Μετρητές Ταλαντώσεων. Απόστολος Σ. Παπαγεωργίου

Second Order RLC Filters

Εθνικό Μετσόβιο Πολυτεχνείο National Technical University of Athens. Aerodynamics & Aeroelasticity: Applications Σπύρος Βουτσινάς / Spyros Voutsinas

Data sheet Thick Film Chip Resistor 5% - RS Series 0201/0402/0603/0805/1206

65W PWM Output LED Driver. IDPV-65 series. File Name:IDPV-65-SPEC

ΔΗΛΩΣΗ ΕΠΙΔΟΣΕΩΝ Αρ. HSL-3_B-1109-CPR-0002

ITU-R BT ITU-R BT ( ) ITU-T J.61 (

Precision Metal Film Fixed Resistor Axial Leaded

Πολιτικός Μηχανικός, Πανεπιστήµιο Θεσσαλίας ρ. Πολιτικός Μηχανικός, Επίκ. Καθηγητής, Πανεπιστήµιο Θεσσαλίας

Heat exchanger. Type WT. For the reheating of airflows in rectangular ducting PD WT 1. 03/2017 DE/en

Gearmotor Data. SERIES GM9000: We have the GM9434H187-R1

Surface Mount Multilayer Chip Capacitors for Commodity Solutions

65W PWM Output LED Driver. IDLV-65 series. File Name:IDLV-65-SPEC

UDZ Swirl diffuser. Product facts. Quick-selection. Swirl diffuser UDZ. Product code example:

MODAL STRENGTH REDUCTION FACTORS FOR THE SEISMIC DESIGN OF ECCENTRICALLY BRACED STEEL FRAMES

Strain gauge and rosettes

SOLUTIONS TO MATH38181 EXTREME VALUES AND FINANCIAL RISK EXAM

2013 AF/09 ΣΤΑΤΙΚΗ ΜΕΛΕΤΗ ΦΩΤΟΒΟΛΤΑΙΚΩΝ ΦΟΡΕΩΝ ΣΤΑΘΕΡΟ ΣΥΣΤΗΜΑ ΑΠΛΟ ΤΡΙΓΩΝΟ

Photometric Data of Lamp

Αλληλεπίδραση Εδάφους-Κατασκευής:

Technical Research Report, Earthquake Research Institute, the University of Tokyo, No. +-, pp. 0 +3,,**1. No ,**1

Chapter 7 Transformations of Stress and Strain

2013 AF/009b ΣΤΑΤΙΚΗ ΜΕΛΕΤΗ ΦΩΤΟΒΟΛΤΑΙΚΩΝ ΦΟΡΕΩΝ ΣΤΑΘΕΡΟ ΣΥΣΤΗΜΑ ΑΠΛΟ ΤΡΙΓΩΝΟ

Study on the Strengthen Method of Masonry Structure by Steel Truss for Collapse Prevention

Hadronic Tau Decays at BaBar

IDPV-25 series. 25W PWM Output LED Driver. File Name:IDPV-25-SPEC S&E

of concrete buildings Illustration of elements design

ST5224: Advanced Statistical Theory II

MasterSeries MasterPort Plus Sample Output

Démographie spatiale/spatial Demography

Κανονισμοί. Θεσμικό πλαίσιο μελέτης και εκτέλεσης έργων

Οι απόψεις και τα συμπεράσματα που περιέχονται σε αυτό το έγγραφο, εκφράζουν τον συγγραφέα και δεν πρέπει να ερμηνευτεί ότι αντιπροσωπεύουν τις

Ordinal Arithmetic: Addition, Multiplication, Exponentiation and Limit

9. Seismic Design of RETAINING STRUCTURES GRAVITY WALLS

DC-DC Constant Current Step-Down LED driver LDD-300L LDD-350L LDD-500L LDD-600L LDD-700L CURRENT RANGE

60W AC-DC High Reliability Slim Wall-mounted Adaptor. SGA60E series. File Name:SGA60E-SPEC

MINIMUM COST SEISMIC DESIGN OF STEEL TANKS

ZLW Series. Single-stage Monoblock Centrifugal Pump ZL PUMP GROUP.,LTD

Μονοβάθμια Συστήματα: Εξίσωση Κίνησης, Διατύπωση του Προβλήματος και Μέθοδοι Επίλυσης. Απόστολος Σ. Παπαγεωργίου

ω ω ω ω ω ω+2 ω ω+2 + ω ω ω ω+2 + ω ω+1 ω ω+2 2 ω ω ω ω ω ω ω ω+1 ω ω2 ω ω2 + ω ω ω2 + ω ω ω ω2 + ω ω+1 ω ω2 + ω ω+1 + ω ω ω ω2 + ω

ΙΑΤΡΙΚΟΣ ΕΞΟΠΛΙΣΜΟΣ ΑΝΑΛΩΣΙΜΑ ΕΞΕΤΑΣΤΙΚΟΙ ΦΑΚΟΙ & ΦΩΤΙΣΜΟΣ

2.019 Design of Ocean Systems. Lecture 6. Seakeeping (II) February 21, 2011

ΕΙΣΑΓΩΓΗ ΣΤΗ ΣΤΑΤΙΣΤΙΚΗ ΑΝΑΛΥΣΗ

Instruction Execution Times


Model VRT Miniature Type (Tapped Base Type)

Βαθιές Θεµελιώσεις Εισαγωγή

On the Galois Group of Linear Difference-Differential Equations

Development of Finer Spray Atomization for Fuel Injectors of Gasoline Engines

Luminaire Property. Photometric Results. Page 1 of 15 Pages. Report No.: 9 Test Time: 2017/5/18 09:59

HIS series. Signal Inductor Multilayer Ceramic Type FEATURE PART NUMBERING SYSTEM DIMENSIONS HIS R12 (1) (2) (3) (4)

Πανεπιστήμιο Θεσσαλίας Τμήμα Πολιτικών Μηχανικών. Αριθμητικές Μέθοδοι : Αλληλεπίδρση Εδάφους - Κατασκευών Αναπληρωτής Καθηγητής Αιμίλιος Κωμοδρόμος 1

FACTORY DIRECT LIGHTING

2013 AF/009 ΣΤΑΤΙΚΗ ΜΕΛΕΤΗ

ect of Modified Wheat Starches on the Textural Properties of Baked Products, such as Cookies

Si Photo-transistor Chip TKA124PT

STATIC ANALYSIS / STRUCTURAL DESIGN GLASSCON SHADOGLASS LOUVERS SYSTEM

Multilayer Chip Inductor

Phasor Diagram of an RC Circuit V R


ΚΑΝΑΛΙ CHANNEL MTL. Κατάλογος - Catalogue. Eνδοδαπέδια Κανάλια & Κουτιά Παροχών - Διακλαδώσεων Underfloor Channels & Boxes and Juction Boxes

ΘΕΡΜΟΚΗΠΙΑΚΕΣ ΚΑΛΛΙΕΡΓΕΙΕΣ ΕΚΤΟΣ ΕΔΑΦΟΥΣ ΘΡΕΠΤΙΚΑ ΔΙΑΛΥΜΑΤΑ

Απόκριση σε Μοναδιαία Ωστική Δύναμη (Unit Impulse) Απόκριση σε Δυνάμεις Αυθαίρετα Μεταβαλλόμενες με το Χρόνο. Απόστολος Σ.

Transcript:

E N G I N E E R S Consulting Engineers jxxx 1 Structure Design - EQ Load Definition and EQ Effects v20 EQ Response Spectra in Direction X, Y, Z X-Dir Y-Dir Z-Dir Fundamental period of building, T 1 5.00 5.00 0.10s NOT OK Note for the employment of the equivalent lateral static force method, T 1,X/Y 4T C and 2.0s (cl.4.3.3.2.1); Importance factor, γ Ι 1.00 T.4.3 Reference peak ground acceleration, a gr (g) 0.070g m/s 2 Hazard Maps X/Y-Dir Z-Dir Design peak ground acceleration, a g (g)=γ I.a gr (g), a vg (g) 0.070 0.063g m/s 2.3.2.1/ T.3. Note ground refers to bedrock; PGA level {negligible 0.040g, low 0.080g, high 0.400g}; cl.3.2.1 Inclusion of vertical action? 0.063g <= 0.250g Not Included cl.4.3.3.5.2 Spectrum type cl.3.2.2.2 Subsoil class T.3.1 S DR (1.25) (R),(SS) and (FS) 16.0mm Initial (small-strain) site natural period, T S = 4H S /V S (FS) Only 0.50s S DR (1.5T S ) = S DR @ 0.75s = S DR (1.25).T D /1.25 = (FS) Only 16.0mm m R (R) and (SS) Only 6.7 m F (FS) Only 0.0 X/Y-Dir Z-Dir Soil response parameter, S 1.50 1.00 T.3.2, T.3.3, cl.3. Spectral amplification factor for 5% damping, β 0 2.5 2.5 cl.3.2.2.5 S D (T D ) 16.0 N/Amm m 6.7 N/A Constant acceleration region lower limit, T B N/A 0.05s.2, T.3.3, T. Constant acceleration region upper limit, T C 0.30 0.15s.2, T.3.3, T. Constant displacement region lower limit, T D 1.25 1.00s.2, T.3.3, T. X/Y-Dir Z-Dir X-Dir Y-Dir Z-Dir Behaviour factor, q = q 0,r k w 1.5 52% 100% 1.5 1.5 1.5 cl.5.2.2.2, cl.3.2 Reduced q 0, q 0,r 2.9 2.9 N/A cl.5.2.2.2, cl.4.2.3.1, Basic q in X, q 0,X cl.5.2.2.2, cl.4. 3.6 3.6 N/A Basic q in Y, q 0,Y cl.5.2.2.2, cl.4. Ductility class DCM N/A cl.5.2.2.2 (α u /α 1 ) X cl.5.2.2.2, cl.4. 1.2 1.2 N/A (α u /α 1 ) Y cl.5.2.2.2, cl.4. Wall failure, k w 1.00 1.00 N/A cl.5.2.2.2, cl.4. Wall aspect ratio, α 0 = Σh wi / Σl wi 10.0 10.0 N/A cl.5.2.2.2

E N G I N E E R S Consulting Engineers jxxx 2 Structure Design - EQ Load Definition and EQ Effects v20 0.250 Design (Inelastic) Response Spectra s.4 S d (g) (g) 0.200 0.150 0.100 0.050 0.000 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 Period, T (s) Sd,X Sd,Y Sd,Z T1,X T1,Y T1,Z X-Dir Y-Dir Z-Dir Elastic (q=1.0) spectral acceleration, S e (g)(t 1 ) 0.014 0.014 0.158g m/s 2 Inelastic (design) spectral acceleration, S d (g)(t 1 ) 0.014 0.014 0.105g m/s 2 Note spectra level {low inelastic 0.050g 0.070g, high inelastic 0.150g 0.200g, high elastic 0.250g 0.300g}; Elastic base shear force, F be (W) = W.S e (g)(t 1 ).λ 0.014 0.014 0.158W kn cl.4.3.3.2.2 Inelastic base shear force, F bd (W) = W.S d (g)(t 1 ).λ 0.014 0.014 0.105W kn cl.4.3.3.2.2.3.4 Correction factor, λ 1.00 cl.4.3.3.2.2.3.4 2.2.5 cl.4.2.3.3.2.2.2.2.2.2.2.2.2.2

E N G I N E E R S Consulting Engineers jxxx 1 Structure Design - EQ Load Definition and EQ Effects v EQ Load in Direction X, Y, Z Note certain cells within this section where indicated are intrinsically linked to the SD - EQ Spectra {X, Y, Z} Note for the employment of the equivalent lateral static force method, T 1,X/Y 4T C and 2.0s (cl.4.3.3.2.1); Building dimension in X, w 50.000 m Building dimension in Y, L 30.000 m Floor area, A F = w.l 1500m 2 X-Dir Y-Dir Z-Dir Elastic base shear force, F be (W) 0.014 0.014 0.158W kn cl.4.3.3.2.2 Inelastic base shear force, F bd (W) 0.014 0.014 0.105W kn cl.4.3.3.2.2 P-delta factor, m 1.33 1.00 N/A cl.4.4.2.2 Coefficients, ϕ and ψ 2i 0.5 0.3 T.4.2, T.A1.1 Storey Storey Height [DL +SDL] i LL i z i ϕψ 2i LL i X Y z i. (m) (kpa) (kpa) (m) (kpa) (m) (m) (kn) (knm) St01 3.000 17.0 5.5 3.000 0.8 50.000 30.000 26738 80213 St02 4.500 11.0 2.5 7.500 0.4 50.000 30.000 17063 127969 St03 3.000 11.0 2.5 10.500 0.4 50.000 30.000 17063 179156 St04 3.000 11.0 2.5 13.500 0.4 50.000 30.000 17063 230344 St05 3.000 11.0 2.5 16.500 0.4 50.000 30.000 17063 281531 St06 3.000 11.0 2.5 19.500 0.4 50.000 30.000 17063 332719 St07 3.000 11.0 2.5 22.500 0.4 50.000 30.000 17063 383906 St08 3.000 11.0 2.5 25.500 0.4 50.000 30.000 17063 435094 St09 3.000 18.5 5.0 28.500 0.8 50.000 30.000 28875 822938 St10 4.500 18.5 5.0 33.000 0.8 50.000 30.000 28875 952875 St11 4.500 18.5 5.0 37.500 0.8 50.000 30.000 28875 1082813 St12 6.000 58.5 2.5 43.500 0.4 50.000 30.000 88313 3841594 St13 3.300 14.0 2.0 46.800 0.3 50.000 30.000 21450 1003860 St14 3.300 14.0 2.0 50.100 0.3 50.000 30.000 21450 1074645 St15 3.300 14.0 2.0 53.400 0.3 50.000 30.000 21450 1145430 St16 3.300 14.0 2.0 56.700 0.3 50.000 30.000 21450 1216215 St17 3.300 14.0 2.0 60.000 0.3 50.000 30.000 21450 1287000 St18 3.300 14.0 2.0 63.300 0.3 50.000 30.000 21450 1357785 St19 3.300 14.0 2.0 66.600 0.3 50.000 30.000 21450 1428570 St20 3.300 14.0 2.0 69.900 0.3 50.000 30.000 21450 1499355 St21 3.300 14.0 2.0 73.200 0.3 50.000 30.000 21450 1570140 St22 3.300 14.0 2.0 76.500 0.3 50.000 30.000 21450 1640925 St23 4.500 14.0 2.0 81.000 0.3 50.000 30.000 21450 1737450 St24 3.300 14.0 2.0 84.300 0.3 50.000 30.000 21450 1808235 St25 3.300 14.0 2.0 87.600 0.3 50.000 30.000 21450 1879020 St26 3.300 14.0 2.0 90.900 0.3 50.000 30.000 21450 1949805 St27 3.300 14.0 2.0 94.200 0.3 50.000 30.000 21450 2020590 St28 3.300 14.0 2.0 97.500 0.3 50.000 30.000 21450 2091375 St29 3.300 14.0 2.0 100.800 0.3 50.000 30.000 21450 2162160 St30 3.300 14.0 2.0 104.100 0.3 50.000 30.000 21450 2232945 St31 3.300 14.0 2.0 107.400 0.3 50.000 30.000 21450 2303730 St32 3.300 14.0 2.0 110.700 0.3 50.000 30.000 21450 2374515 St33 3.300 14.0 2.0 114.000 0.3 50.000 30.000 21450 2445300 St34 3.300 14.0 2.0 117.300 0.3 50.000 30.000 21450 2516085 St35 3.300 14.0 2.0 120.600 0.3 50.000 30.000 21450 2586870 St36 3.300 14.0 2.0 123.900 0.3 50.000 30.000 21450 2657655 St37 3.300 14.0 2.0 127.200 0.3 50.000 30.000 21450 2728440 St38 3.300 14.0 2.0 130.500 0.3 50.000 30.000 21450 2799225 St39 3.300 14.0 2.0 133.800 0.3 50.000 30.000 21450 2870010 St40 3.300 14.0 2.0 137.100 0.3 50.000 30.000 21450 2940795 St41 3.300 14.0 2.0 140.400 0.3 50.000 30.000 21450 3011580 St42 3.300 14.0 2.0 143.700 0.3 50.000 30.000 21450 3082365 St43 3.300 14.0 2.0 147.000 0.3 50.000 30.000 21450 3153150 St44 3.300 14.0 1.5 150.300 0.2 50.000 30.000 21338 3207026 St45 6.000 14.0 1.5 156.300 0.2 50.000 30.000 21338 3335051

E N G I N E E R S Consulting Engineers jxxx 1 Structure Design - EQ Load Definition and EQ Effects v EQ Load in Direction X, Y, Z Note certain cells within this section where indicated are intrinsically linked to the SD - EQ Spectra {X, Y, Z} Note for the employment of the equivalent lateral static force method, T 1,X/Y 4T C and 2.0s (cl.4.3.3.2.1); Building dimension in X, w 50.000 m Building dimension in Y, L 30.000 m Floor area, A F = w.l 1500m 2 X-Dir Y-Dir Z-Dir Elastic base shear force, F be (W) 0.014 0.014 0.158W kn cl.4.3.3.2.2 Inelastic base shear force, F bd (W) 0.014 0.014 0.105W kn cl.4.3.3.2.2 P-delta factor, m 1.33 1.00 N/A cl.4.4.2.2 Coefficients, ϕ and ψ 2i 0.5 0.3 T.4.2, T.A1.1 Storey Storey Height [DL +SDL] i LL i z i ϕψ 2i LL i X Y z i. (m) (kpa) (kpa) (m) (kpa) (m) (m) (kn) (knm) 45 156.3 670.0 105.5 15.8 50.0 30.0 1029 79868 (m) (kpa) (kpa) (kpa) (m) (m) (MN) (MNm) Note that dynamic weight, = ([DL+SDL] i + ϕψ 2i LL i ).A; cl.3.2.4, cl.4.2 cl.4.3.3.2.3

E N G I N E E R S Consulting Engineers jxxx 2 Structure Design - EQ Load Definition and EQ Effects v Structure Design - EQ Load Definition and EQ Effects XX 05/06/2016 } sheet; X-Dir Y-Dir Z-Dir Total dynamic weight of building, W = Σ 1029MN Base floor inclusion in W cl.4.3.3.2.2 Total weight of building, ΣW DL+SDL+LL = Σ([DL+SDL] i +LL i ).A F 1163MN Elastic base shear force, F be = F be (W).W 14402 14402 162026kN Elastic base moment, M be = Σ[z i.f ie ] 1960 1474 N/AMNm Inelastic base shear force, F bd = F bd (W).W 14402 14402 108017kN Inelastic base moment, M bd = Σ[z i.f id ] 1960 1474 N/AMNm Base shear force (foundations), F b,f = F be or γ Rd.Ω.F bd 14402 14402 162026kN cl.4.4.2.6 Base moment (foundations), M b,f = F be or γ Rd.Ω.M bd 1960 1474 N/AMNm cl.4.4.2.6 1 Overstrength factor, γ Rd and multiplicative factor, Ω 1.0 1.4 cl.4.4.2.6 F ie,x F ie,y m X.F ie,x m Y.F ie,y z i.m X.F ie,x z i.m Y.F ie,y m X.F ie,x / m Y.F ie,y / (kn) (kn) (kn) (kn) (knm) (knm) (%) (%) 14 14 19 14 58 43 0.1% 0.1% 23 23 31 23 230 173 0.2% 0.1% 32 32 43 32 451 339 0.3% 0.2% 42 42 55 42 746 561 0.3% 0.2% 51 51 68 51 1114 838 0.4% 0.3% 60 60 80 60 1556 1170 0.5% 0.4% 69 69 92 69 2072 1558 0.5% 0.4% 78 78 104 78 2661 2001 0.6% 0.5% 148 148 197 148 5625 4229 0.7% 0.5% 172 172 229 172 7542 5670 0.8% 0.6% 195 195 260 195 9739 7322 0.9% 0.7% 693 693 921 693 40078 30134 1.0% 0.8% 181 181 241 181 11268 8472 1.1% 0.8% 194 194 258 194 12913 9709 1.2% 0.9% 207 207 275 207 14670 11030 1.3% 1.0% 219 219 292 219 16539 12435 1.4% 1.0% 232 232 309 232 18520 13925 1.4% 1.1% 245 245 326 245 20613 15499 1.5% 1.1% 258 258 343 258 22818 17157 1.6% 1.2% 270 270 360 270 25136 18899 1.7% 1.3% 283 283 377 283 27565 20726 1.8% 1.3% 296 296 394 296 30106 22636 1.8% 1.4% 313 313 417 313 33753 25378 1.9% 1.5% 326 326 434 326 36559 27488 2.0% 1.5% 339 339 451 339 39477 29682 2.1% 1.6% 352 352 468 352 42507 31960 2.2% 1.6% 364 364 485 364 45650 34323 2.3% 1.7% 377 377 502 377 48904 36770 2.3% 1.8% 390 390 519 390 52271 39301 2.4% 1.8% 403 403 536 403 55749 41917 2.5% 1.9% 415 415 553 415 59340 44616 2.6% 1.9% 428 428 569 428 63042 47400 2.7% 2.0% 441 441 586 441 66857 50268 2.7% 2.1% 454 454 603 454 70784 53221 2.8% 2.1% 466 466 620 466 74822 56257 2.9% 2.2% 479 479 637 479 78973 59378 3.0% 2.2% 492 492 654 492 83236 62583 3.1% 2.3% 505 505 671 505 87611 65873 3.1% 2.4% 518 518 688 518 92098 69246 3.2% 2.4% 530 530 705 530 96697 72704 3.3% 2.5% 543 543 722 543 101408 76246 3.4% 2.5% 556 556 739 556 106231 79873 3.4% 2.6% 569 569 756 569 111166 83583 3.5% 2.7% 578 578 769 578 115603 86920 3.6% 2.7% 601 601 800 601 125017 93998 3.7% 2.8%

E N G I N E E R S Consulting Engineers jxxx 2 Structure Design - EQ Load Definition and EQ Effects v Structure Design - EQ Load Definition and EQ Effects XX 05/06/2016 } sheet; X-Dir Y-Dir Z-Dir Total dynamic weight of building, W = Σ 1029MN Base floor inclusion in W cl.4.3.3.2.2 Total weight of building, ΣW DL+SDL+LL = Σ([DL+SDL] i +LL i ).A F 1163MN Elastic base shear force, F be = F be (W).W 14402 14402 162026kN Elastic base moment, M be = Σ[z i.f ie ] 1960 1474 N/AMNm Inelastic base shear force, F bd = F bd (W).W 14402 14402 108017kN Inelastic base moment, M bd = Σ[z i.f id ] 1960 1474 N/AMNm Base shear force (foundations), F b,f = F be or γ Rd.Ω.F bd 14402 14402 162026kN cl.4.4.2.6 Base moment (foundations), M b,f = F be or γ Rd.Ω.M bd 1960 1474 N/AMNm cl.4.4.2.6 1 Overstrength factor, γ Rd and multiplicative factor, Ω 1.0 1.4 cl.4.4.2.6 F ie,x F ie,y m X.F ie,x m Y.F ie,y z i.m X.F ie,x z i.m Y.F ie,y m X.F ie,x / m Y.F ie,y / (kn) (kn) (kn) (kn) (knm) (knm) (%) (%) 14402 14402 19155 14402 1960 1474 1.4% 1.4% Σ (kn) (kn) (kn) (kn) (MNm) (MNm) (%) (%) 2.4 Note that elastic seismic force, F ie = F be.(z i.m i )/ Σ(z j.m j ); 3

E N G I N E E R S Consulting Engineers jxxx 3 Structure Design - EQ Load Definition and EQ Effects v Made by Date Chd. 2 F id,x F id,y m X.F id,x m Y.F id,y z i.m X.F id,x z i.m Y m X.F id,x / m Y.F id,y /.F id,y (kn) (kn) (kn) (kn) (knm) (knm) (%) (%) 14 14 19 14 58 43 0.1% 0.1% 23 23 31 23 230 173 0.2% 0.1% 32 32 43 32 451 339 0.3% 0.2% 42 42 55 42 746 561 0.3% 0.2% 51 51 68 51 1114 838 0.4% 0.3% 60 60 80 60 1556 1170 0.5% 0.4% 69 69 92 69 2072 1558 0.5% 0.4% 78 78 104 78 2661 2001 0.6% 0.5% 148 148 197 148 5625 4229 0.7% 0.5% 172 172 229 172 7542 5670 0.8% 0.6% 195 195 260 195 9739 7322 0.9% 0.7% 693 693 921 693 40078 30134 1.0% 0.8% 181 181 241 181 11268 8472 1.1% 0.8% 194 194 258 194 12913 9709 1.2% 0.9% 207 207 275 207 14670 11030 1.3% 1.0% 219 219 292 219 16539 12435 1.4% 1.0% 232 232 309 232 18520 13925 1.4% 1.1% 245 245 326 245 20613 15499 1.5% 1.1% 258 258 343 258 22818 17157 1.6% 1.2% 270 270 360 270 25136 18899 1.7% 1.3% 283 283 377 283 27565 20726 1.8% 1.3% 296 296 394 296 30106 22636 1.8% 1.4% 313 313 417 313 33753 25378 1.9% 1.5% 326 326 434 326 36559 27488 2.0% 1.5% 339 339 451 339 39477 29682 2.1% 1.6% 352 352 468 352 42507 31960 2.2% 1.6% 364 364 485 364 45650 34323 2.3% 1.7% 377 377 502 377 48904 36770 2.3% 1.8% 390 390 519 390 52271 39301 2.4% 1.8% 403 403 536 403 55749 41917 2.5% 1.9% 415 415 553 415 59340 44616 2.6% 1.9% 428 428 569 428 63042 47400 2.7% 2.0% 441 441 586 441 66857 50268 2.7% 2.1% 454 454 603 454 70784 53221 2.8% 2.1% 466 466 620 466 74822 56257 2.9% 2.2% 479 479 637 479 78973 59378 3.0% 2.2% 492 492 654 492 83236 62583 3.1% 2.3% 505 505 671 505 87611 65873 3.1% 2.4% 518 518 688 518 92098 69246 3.2% 2.4% 530 530 705 530 96697 72704 3.3% 2.5% 543 543 722 543 101408 76246 3.4% 2.5% 556 556 739 556 106231 79873 3.4% 2.6% 569 569 756 569 111166 83583 3.5% 2.7% 578 578 769 578 115603 86920 3.6% 2.7% 601 601 800 601 125017 93998 3.7% 2.8%

E N G I N E E R S Consulting Engineers jxxx 3 Structure Design - EQ Load Definition and EQ Effects v Made by Date Chd. 2 F id,x F id,y m X.F id,x m Y.F id,y z i.m X.F id,x z i.m Y m X.F id,x / m Y.F id,y /.F id,y (kn) (kn) (kn) (kn) (knm) (knm) (%) (%) 14402 14402 19155 14402 1960 1474 1.4% 1.4% Σ (kn) (kn) (kn) (kn) (MNm) (MNm) (%) (%) Note that inelastic seismic force, F id = F bd. (z i.m i ) / Σ(z j.m j );

E N G I N E E R S Consulting Engineers jxxx 1 Structure Design - EQ Load Definition and EQ Effects v2 EQ Load Displacements in Direction X Note storey references and cumulative building heights within this section are intrinsically linked to the SD - EQ Criteria for δ X / h 1 : 250 = 0.00400 Criteria for δ X / h s 1 : 250 = 0.00400 cl.4.4.3.2 Total Total Total Total Relative Inter Relative Relative Storey Disp Building Disp Disp Disp Storey Disp Disp in X, δ X Height, h Ratio Ratio in X, q. δ X Height, h s Ratio Ratio mm m δ X / h Check mm m δ X / h s Check St01 0.00 3.000 0.00000 OK 3.000 0.00000 OK St02 0.00 7.500 0.00000 OK 4.500 0.00000 OK St03 0.00 10.500 0.00000 OK 3.000 0.00000 OK St04 0.00 13.500 0.00000 OK 3.000 0.00000 OK St05 0.00 16.500 0.00000 OK 3.000 0.00000 OK St06 0.00 19.500 0.00000 OK 3.000 0.00000 OK St07 0.00 22.500 0.00000 OK 3.000 0.00000 OK St08 0.00 25.500 0.00000 OK 3.000 0.00000 OK St09 0.00 28.500 0.00000 OK 3.000 0.00000 OK St10 0.00 33.000 0.00000 OK 4.500 0.00000 OK St11 0.00 37.500 0.00000 OK 4.500 0.00000 OK St12 0.00 43.500 0.00000 OK 6.000 0.00000 OK St13 0.00 46.800 0.00000 OK 3.300 0.00000 OK St14 0.00 50.100 0.00000 OK 3.300 0.00000 OK St15 0.00 53.400 0.00000 OK 3.300 0.00000 OK St16 0.00 56.700 0.00000 OK 3.300 0.00000 OK St17 0.00 60.000 0.00000 OK 3.300 0.00000 OK St18 0.00 63.300 0.00000 OK 3.300 0.00000 OK St19 0.00 66.600 0.00000 OK 3.300 0.00000 OK St20 0.00 69.900 0.00000 OK 3.300 0.00000 OK St21 0.00 73.200 0.00000 OK 3.300 0.00000 OK St22 0.00 76.500 0.00000 OK 3.300 0.00000 OK St23 0.00 81.000 0.00000 OK 4.500 0.00000 OK St24 0.00 84.300 0.00000 OK 3.300 0.00000 OK St25 0.00 87.600 0.00000 OK 3.300 0.00000 OK St26 0.00 90.900 0.00000 OK 3.300 0.00000 OK St27 0.00 94.200 0.00000 OK 3.300 0.00000 OK St28 0.00 97.500 0.00000 OK 3.300 0.00000 OK St29 0.00 100.800 0.00000 OK 3.300 0.00000 OK St30 0.00 104.100 0.00000 OK 3.300 0.00000 OK St31 0.00 107.400 0.00000 OK 3.300 0.00000 OK St32 0.00 110.700 0.00000 OK 3.300 0.00000 OK St33 0.00 114.000 0.00000 OK 3.300 0.00000 OK St34 0.00 117.300 0.00000 OK 3.300 0.00000 OK St35 0.00 120.600 0.00000 OK 3.300 0.00000 OK St36 0.00 123.900 0.00000 OK 3.300 0.00000 OK St37 0.00 127.200 0.00000 OK 3.300 0.00000 OK St38 0.00 130.500 0.00000 OK 3.300 0.00000 OK St39 0.00 133.800 0.00000 OK 3.300 0.00000 OK St40 0.00 137.100 0.00000 OK 3.300 0.00000 OK

E N G I N E E R S Consulting Engineers jxxx 1 Structure Design - EQ Load Definition and EQ Effects v2 EQ Load Displacements in Direction X Note storey references and cumulative building heights within this section are intrinsically linked to the SD - EQ Criteria for δ X / h 1 : 250 = 0.00400 Criteria for δ X / h s 1 : 250 = 0.00400 cl.4.4.3.2 Total Total Total Total Relative Inter Relative Relative Storey Disp Building Disp Disp Disp Storey Disp Disp in X, δ X Height, h Ratio Ratio in X, q. δ X Height, h s Ratio Ratio mm m δ X / h Check mm m δ X / h s Check St41 0.00 140.400 0.00000 OK 3.300 0.00000 OK St42 0.00 143.700 0.00000 OK 3.300 0.00000 OK St43 0.00 147.000 0.00000 OK 3.300 0.00000 OK St44 0.00 150.300 0.00000 OK 3.300 0.00000 OK St45 0.00 156.300 0.00000 OK 6.000 0.00000 OK

E N G I N E E R S Consulting Engineers jxxx 2 Structure Design - EQ Load Definition and EQ Effects v2 EQ Load Displacements in Direction Y Q Load {X, Y, Z} sheet; Criteria for δ Y / h 1 : 250 = 0.00400 Criteria for δ Y / h s 1 : 250 = 0.00400 cl.4.4.3.2 Total Total Total Total Relative Inter Relative Relative Storey Disp Building Disp Disp Disp Storey Disp Disp in Y, δ Y Height, h Ratio Ratio in Y, q. δ Y Height, h s Ratio Ratio mm m δ Y / h Check mm m δ Y / h s Check St01 0.00 3.000 0.00000 OK 3.000 0.00000 OK St02 0.00 7.500 0.00000 OK 4.500 0.00000 OK St03 0.00 10.500 0.00000 OK 3.000 0.00000 OK St04 0.00 13.500 0.00000 OK 3.000 0.00000 OK St05 0.00 16.500 0.00000 OK 3.000 0.00000 OK St06 0.00 19.500 0.00000 OK 3.000 0.00000 OK St07 0.00 22.500 0.00000 OK 3.000 0.00000 OK St08 0.00 25.500 0.00000 OK 3.000 0.00000 OK St09 0.00 28.500 0.00000 OK 3.000 0.00000 OK St10 0.00 33.000 0.00000 OK 4.500 0.00000 OK St11 0.00 37.500 0.00000 OK 4.500 0.00000 OK St12 0.00 43.500 0.00000 OK 6.000 0.00000 OK St13 0.00 46.800 0.00000 OK 3.300 0.00000 OK St14 0.00 50.100 0.00000 OK 3.300 0.00000 OK St15 0.00 53.400 0.00000 OK 3.300 0.00000 OK St16 0.00 56.700 0.00000 OK 3.300 0.00000 OK St17 0.00 60.000 0.00000 OK 3.300 0.00000 OK St18 0.00 63.300 0.00000 OK 3.300 0.00000 OK St19 0.00 66.600 0.00000 OK 3.300 0.00000 OK St20 0.00 69.900 0.00000 OK 3.300 0.00000 OK St21 0.00 73.200 0.00000 OK 3.300 0.00000 OK St22 0.00 76.500 0.00000 OK 3.300 0.00000 OK St23 0.00 81.000 0.00000 OK 4.500 0.00000 OK St24 0.00 84.300 0.00000 OK 3.300 0.00000 OK St25 0.00 87.600 0.00000 OK 3.300 0.00000 OK St26 0.00 90.900 0.00000 OK 3.300 0.00000 OK St27 0.00 94.200 0.00000 OK 3.300 0.00000 OK St28 0.00 97.500 0.00000 OK 3.300 0.00000 OK St29 0.00 100.800 0.00000 OK 3.300 0.00000 OK St30 0.00 104.100 0.00000 OK 3.300 0.00000 OK St31 0.00 107.400 0.00000 OK 3.300 0.00000 OK St32 0.00 110.700 0.00000 OK 3.300 0.00000 OK St33 0.00 114.000 0.00000 OK 3.300 0.00000 OK St34 0.00 117.300 0.00000 OK 3.300 0.00000 OK St35 0.00 120.600 0.00000 OK 3.300 0.00000 OK St36 0.00 123.900 0.00000 OK 3.300 0.00000 OK St37 0.00 127.200 0.00000 OK 3.300 0.00000 OK St38 0.00 130.500 0.00000 OK 3.300 0.00000 OK St39 0.00 133.800 0.00000 OK 3.300 0.00000 OK St40 0.00 137.100 0.00000 OK 3.300 0.00000 OK

E N G I N E E R S Consulting Engineers jxxx 2 Structure Design - EQ Load Definition and EQ Effects v2 EQ Load Displacements in Direction Y Q Load {X, Y, Z} sheet; Criteria for δ Y / h 1 : 250 = 0.00400 Criteria for δ Y / h s 1 : 250 = 0.00400 cl.4.4.3.2 Total Total Total Total Relative Inter Relative Relative Storey Disp Building Disp Disp Disp Storey Disp Disp in Y, δ Y Height, h Ratio Ratio in Y, q. δ Y Height, h s Ratio Ratio mm m δ Y / h Check mm m δ Y / h s Check St41 0.00 140.400 0.00000 OK 3.300 0.00000 OK St42 0.00 143.700 0.00000 OK 3.300 0.00000 OK St43 0.00 147.000 0.00000 OK 3.300 0.00000 OK St44 0.00 150.300 0.00000 OK 3.300 0.00000 OK St45 0.00 156.300 0.00000 OK 6.000 0.00000 OK