, / 230 4,6 / 2, , / 230 5,4 / 2,7

Σχετικά έγγραφα
ZLW Series. Single-stage Monoblock Centrifugal Pump ZL PUMP GROUP.,LTD

PERFOMANCE TABLE FOR 3M SERIES 3000 R.P.M. / 2 POLES LRT RLT. Eff % P.F. COSΦ. Duty Type : (S1) Rated Voltage : 400 V / 440 V

Applications Water distribution

DLG Series. Lowara SPECIFICATIONS APPLICATIONS ACCESSORIES MATERIALS. General Catalogue

Lowara APPLICATIONS MATERIALS. General Catalogue

4 Way Reversing Valve

Lowara SPECIFICATIONS

Finish: Anticorrosive finish in polyester. Number of motor poles 4=1400 r/min. 50 Hz 6=900 r/min. 50 Hz 8=750 r/min. 50 Hz

Engineering Data High-wall Type (3 series) Indoor Unit. Contents MMK-AP0073H MMK-AP0093H MMK-AP0123H MMK-AP0153H MMK-AP0183H MMK-AP0243H.

Model: MTZ22. Data. Cylinder count: 1 Displacement [m³/h]: 6,63 Cylinder capacity [cm³]: 38,1 RPM [min -1 ]: 2900 Weight [kg]: 21 Oil charge [dm³]: 1

LOWARA e-nsce, e-nscs, e-nscf

4 Way Reversing Valve

7AAC63-90 SINGLE-PHASE MOTORS PERMANENT CAPACITOR 7AACC SINGLE-PHASE MOTORS CAP START - CAP RUN. squirrel cage induction motors 7AACC63-100

50 Hz n= 1450 rpm. Standardised EN 733 centrifugal pumps. PERFORMANCE RANGE Flow rate up to 3000 l/min (180 m³/h) Head up to 24 m INSTALLATION AND USE

MATRIX. EBARA PUMPS EUROPE S.p.A. HORIZONTAL MULTISTAGE PUMPS

Vertical multistage centrifugal pumps in AISI 316 stainless steel

Westfalia Bedienungsanleitung. Nr

HORIZONTAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS in AISI 304

Karta Katalogowa CATALOGUE CARD

Terminal Contact UL Insulation Designation (provided with) style form system approval Flux tight

REFERENCE. Surge Absorber Unit. Contactor AS R 50Hz AC220V. Separate Mounting Unit. Mechanical Interlock Unit

S /5000 BTU/Hr. 1000/1500 Watt

Siemens AG Rated current 1FK7 Compact synchronous motor Natural cooling. I rated 7.0 (15.4) 11.5 (25.4) (2.9) 3.3 (4.4)

Contactors & Thermal Overload Relays

Type 947D Polypropylene, High Energy Density, DC Link Capacitors

SIEMENS Squirrel Cage Induction Standard Three-phase Motors

+85 C Snap-Mount Aluminum Electrolytic Capacitors. High Voltage Lead free Leads Rugged Design. -40 C to +85 C

RECIPROCATING COMPRESSOR CALCULATION SHEET ISOTHERMAL COMPRESSION Gas properties, flowrate and conditions. Compressor Calculation Sheet

VERTICAL MULTI-CELL CENTRIFUGAL PUMPS IN AISI 316 STAINLESS STEEL

HORIZONTAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS in AISI 304

TM ZX. Copeland EazyCool TM. ZX Digital. Μηχανήµατα Εξωτερικής Χρήσης

Aluminum Capacitors C, Tubular, Radial Lead

NMBTC.COM /

High hydraulic efficiency Motor designed to EN standards IDENTIFICATION NAME. F - in line ports with ROUND FLANGES (counterflanges on request)

Specification. code ±1.0 ±1.0 ±1.0 ±1.0 ±0.5 approx (g)

Digital motor protection relays

RAC. Technical Data Book. RAC(Quantum) for North America (R410A, 60Hz, HP) Model : AR09/12/18/24KSFPDWQNCV AR09/12/18/24KSFPDWQXCV

Heat exchanger. Type WT. For the reheating of airflows in rectangular ducting PD WT 1. 03/2017 DE/en

RAC. Technical Data Book. RAC(Max Heat) for North America (R410A, 60Hz, HP) Model : AR09/12KSWSPWKNCV AR09/12KSWSPWKXCV

SERVICE MANUAL OUTDOOR UNIT

COPELAND SCROLL AIR COOLED CONDENSING UNITS

4K HDMI Splitter 1x4. User s Guide / Bedienungsanleitung / Εγχειρίδιο Χρήστη

- CONSTRUCTIONS 300 SECTIONAL VIEW MATRIX SECTIONAL VIEW MATRIX CONSTRUCTIONS 302 CONSTRUCTIONS 303 MECHANICAL SEAL 304

A31. Aluminium heat exchanger A31

High pressure centrifugal pumps

Single-channel Safety Barriers Series 9001

- DIMENSIONS AND WEIGHT 400 PUMP MATRIX PUMP DRAWING MATRIX 5/10/ PUMP TABLE MATRIX 5/10/ PACKING 403

Aluminum Electrolytic Capacitors (Large Can Type)

MATRIX HORIZONTAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS. Your Life, our Quality. Worldwide.

RSDW08 & RDDW08 series

Ventilated Distribution Transformers

Service Manual. Models: GWH09ABA-K6DNA1B GWH09ABA-K6DNC8B GWH12ABA-K6DNA1B GWH12ABA-K6DNC8B (Refrigerant R32) GREE ELECTRIC APPLIANCES,INC.

FDL - FXDL FBDL SERIES

RECIPROCATING COMPRESSOR CALCULATION SHEET

Planheizkörper Carat 5.5. Planheizkörper Typ 11, 20, 21, 22, 33 und Typ 10, 11, 20 und 21 Vertikal /2013

Aluminum Electrolytic Capacitors

Πρωτότυπο εγχειρίδιο λειτουργίας G-BH7 2BH7 2 2BH7 3 2BH7 4 2BH7 5 2BH7 6. G-Serie G-Series. Seitenkanal Side Channel

Smaller. 6.3 to 100 After 1 minute's application of rated voltage at 20 C, leakage current is. not more than 0.03CV or 4 (µa), whichever is greater.

LS series ALUMINUM ELECTROLYTIC CAPACITORS CAT.8100D. Specifications. Drawing. Type numbering system ( Example : 200V 390µF)

Aerovox Corp. Type H High Voltage AC & DC Capacitors. Film Capacitors for Power Electronics Applications. RoHS Compliant. Highlights.

UDZ Swirl diffuser. Product facts. Quick-selection. Swirl diffuser UDZ. Product code example:

Bohrbild im Längsholz. Einstellbereich

Page - DIMENSIONS AND WEIGHT 400 PUMP DRAWING 400 DIMENSIONS PUMP TABLE 401 PACKING 402

Linear diffuser. Dimensions. Description

65W PWM Output LED Driver. IDLV-65 series. File Name:IDLV-65-SPEC

SPBW06 & DPBW06 series

Technical Report. General Design Data of a Three Phase Induction Machine 90kW Squirrel Cage Rotor

Engineer Reference 1 / / A 35 7/16 X 7 7/8 X 23 5/8 31 1/8 X 21 7/8 X 11 1/4 14 T T 75 R410A oz/ft over 50' 265 / 318 / 388

Gearmotor Data. SERIES GM9000: We have the GM9434H187-R1

OWA-60E series IP67. 60W Single Output Moistureproof Adaptor. moistureproof. File Name:OWA-60E-SPEC

ACTORS IEC CONT Ex9C

60W AC-DC High Reliability Slim Wall-mounted Adaptor. SGA60E series. File Name:SGA60E-SPEC

Split. Air Conditioning Technical Data RXM-M

Type selection. Type selection for pressure series from 100 dapa to 3150 dapa

Series AM2DZ 2 Watt DC-DC Converter

RECIPROCATING COMPRESSOR CALCULATION SHEET

65W PWM Output LED Driver. IDPV-65 series. File Name:IDPV-65-SPEC

Content. BSeries-120V/277V-12W~18W. LEDDriver ConstantCurrentType. LEDDriver ConstantVoltageType. Dimensions:

ΜΜ917-Σχεδιασμός Ενεργειακών Συστημάτων

Long 3000 hour life at 105 C with high ripple current capability 2 and 3 pin versions available Can vent construction

TECHNICAL DATA Date 12/22/15 Series 50GF22.2

IDPV-45 series. 45W PWM Output LED Driver. File Name:IDPV-45-SPEC S&E

Swirl diffusers, Variable swirl diffusers Swirl diffusers

- DIMENSIONS AND WEIGHT 400 PUMP MATRIX PUMP DRAWING MATRIX DIMENSION TABLE MATRIX PACKING 403

15W DIN Rail Type DC-DC Converter. DDR-15 s e r i e s. File Name:DDR-15-SPEC

Type. Capacities. Flanged Safety Relief Valves spring loaded. The-Safety-Valve.com LWN E

Return Line Filters Type RTF10/25

ECOL Motors In Aluminum Housing

Multilayer Ceramic Chip Capacitors

Features. Terminal Contact Enclosure style style form Open type Dust cover Ears on cover Antirotation-tab Ears on top

15W DIN Rail Type DC-DC Converter. DDR-15 series. File Name:DDR-15-SPEC

motori elettrici electric motors

TYJX Series Rare Earth Permanent Magnet Excited Three Phase Synchronous Motor

± 20% (rated cap. [µf] ) 1000 Leakage Current: For capacitance values > 33000µF, add the value of:

+85 C Screw Terminal Aluminum Electrolytic Capacitors. For filtering applications. Capacitance change Dissipation factor Leakage current

EHS. EHS Split (50Hz)

Multilayer Ceramic Chip Capacitors

TIME SWITCHES AND TWILIGHT SWITCHES

GST220A series. 220W AC-DC High Reliability Industrial Adaptor UL EN J CNS14336 AS/NZS GB4943 IEC

Electrical Specifications at T AMB =25 C DC VOLTS (V) MAXIMUM POWER (dbm) DYNAMIC RANGE IP3 (dbm) (db) Output (1 db Comp.) at 2 f U. Typ.

Transcript:

Einstufige Kompressoren mit Einphasen-Wechselstrom Motor; Volumenstrom bis zu 335 m 3 /h Single stage compressors with single phase AC motor; volume flow up to 335 m 3 /h Bestell-Nr. Motor (IP55, Wärmeklasse F) Gewicht Schall- Druckbegrenzungsventil ab Lager lieferbar Fre- Bemessungs- ca. druck- Stück x Typ quenz Leistung Spannung Strom pegel Order No. Motor (IP55, insulation class F) Weight Sound Pressure relief valve available ex stock Fre- rated approx. pressure Items x type quency output voltage current level Hz kw V A kg db(a) 2BH1 1-7 A A1 5,2 23 1,7 11 5-2BH1 1-7 A V5 2BH1 3-7 A V15 5,2 115 / 23 3,1 / 1,6 5-11 6,23 115 / 23 4,6 / 2,3 53-5,37 115 / 23 5,4 / 2,7 53 11 6,45 115 / 23 6,6 / 3,3 56 1 x 2BX2 115/...144 2BH1 33-7 A V15 5,37 115 / 23 5,4 / 2,7 54 11 2BH1 33-7 E V15 6,45 115 / 23 6,6 / 3,3 57 1 x 2BX2 115/...144 2BH1 49-7 A A11 5,5 23 4,1 16 63-2BH1 49-7 A V25 5 1,1 115 / 23 13, / 6,5 63 17 6 1,3 115 / 23 14, / 7, 1 x 2BX2 115/...144 2BH1-7 A A11 5,8 23 5,2 15 63 2BH1-7 A V25 5 1,1 115 / 23 13, / 6,5 63 16 6 1,3 115 / 23 14, / 7, 1 x 2BX2 115/...144 2BH1 41-7 H A31 5 1,5 23 9,1 26 66 2BH1 41-7 H V45 2BH1 43-7 A A11 2BH1 43-7 E A11 5 1,5 115 / 23 22 / 11 66 27 6 1, 115 / 23 24 / 12 69 1 x 2BX2 115/...144 5,8 23 5,2 16 2BH1 43-7 A V25 5 1,1 115 / 23 13, / 6,5 16 2BH1 43-7 E V25 6 1,3 115 / 23 14, / 7, 65 1 x 2BX2 115/...144 2BH1 5-7 A A21 5 1,5 23 9 24 2BH1 5-7 A V35 2BH1 53-7 A A21 2BH1 53-7 E A21 5 1,5 115 / 23 22, / 11, 26 6 1, 115 / 23 24, / 12, 7 1 x 2BX2 115/...148 5 1,5 23 9 26 65 2BH1 53-7 A V35 5 1,5 115 / 23 22, / 11, 65 26 2BH1 53-7 E V35 6 1, 115 / 23 24, / 12, 71 1 x 2BX2 115/...148 2BH1 6-7 A A11 5 23 12,8 3 72 E... Gaseinlass auf der Verdichterseite Suction port on compressor side A... Gaseinlass und -Auslass motorseitig (Standard) Suction and discharge port on motor side (standard) Bedingungen siehe Seite 155 See page 155 for conditions applied 42 www.gd-elmorietschle.de Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

5 Hz Auswahldiagramm Selection diagram Ansaugvolumenstrom in m 3 /h Suction capacity in m 3 /h 3 1 2BH16 2BH153 2BH143 2BH133 2BH13 2BH15 2BH11 2BH1 2BH149,5,8,2,37,37 1,1 1,5 (23V) 1,1 1,5,8 1,5 1,1 2BH141 1,5 1,5 (23V) 1 3 Druck Pressure Gesamtdruckdifferenz in mbar Total pressure difference in mbar 6 Hz Auswahldiagramm Selection diagram Ansaugvolumenstrom in m 3 /h Suction capacity in m 3 /h 3 1 2BH153 2BH143 2BH141 2BH133 2BH13 2BH11 2BH1 2BH149 2BH15,45 1, 1,3 1,3 1, 1,3 1,,45,23 1 3 Gesamtdruckdifferenz in mbar Total pressure difference in mbar Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH www.gd-elmorietschle.de 43

Einstufiger Kompressor mit Dreiphasen-Asynchronmotor; Volumenstrom bis zu 5 m 3 /h Single stage compressor with three phase asynchronous motor; volume flow up to 5 m 3 /h Bestell-Nr. Motor (IP55, Wärmeklasse F) Gewicht Schall- Druckbegrenzungsventil ab Lager lieferbar Fre- Bemessungs- ca. druck- Stück x Typ quenz Leistung Spannung Strom pegel Order No. Motor (IP55, insulation class F) Weight Sound Pressure relief valve available ex stock Fre- rated approx. pressure Items x type quency output voltage current level Hz kw V A kg db(a) 2BH1 1-7 A H6 5,2-24 / 345-415 Y 1,39 /,8 Y 5 9-6,23 22-2 / 38-48 Y 1,55 /,9 Y 53 2BH1 3-7 A H6 5,25-24 / 345-415 Y 2,1 / 1,2 Y 53 9 6,29 22-2 / 38-48 Y 1, / 1, Y 56 1 x 2BX2 115/...144 2BH1 3-7 A H16 5,4-24 / 345-415 Y 2,6 / 1,5 Y 53 1 6,5 22-2 / 38-48 Y 2,6 / 1,5 Y 56 1 x 2BX2 115/...144 2BH1 33-7 A H6 5,25-24 / 345-415 Y 2,1 / 1,2 Y 54 1 2BH1 33-7 E H6 6,29 22-2 / 38-48 Y 1, / 1, Y 57 1 x 2BX2 115/...144 2BH1 33-7 A H16 5,4-24 / 345-415 Y 2,6 / 1,5 Y 54 11 2BH1 33-7 E H16 6,5 22-2 / 38-48 Y 2,6 / 1,5 Y 57 1 x 2BX2 115/...144 2BH1 33-7 A H26 5,7-24 / 345-415 Y 3,8 / Y 54 12 2BH1 33-7 E H26 6,83 22-2 / 38-48 Y 3, / 2,15 Y 57 1 x 2BX2 115/...144 2BH1 49-7 A H16 5,6-24 / 345-415 Y 2,8 / 1,6 Y 63 16-6,85 22-2 / 38-48 Y 3,6 / 2,1 Y 2BH1-7 A H6 5,7-24 / 345-415 Y 3,8 / Y 63 13 6,83 22-2 / 38-48 Y 3, / 2,15 Y 1 x 2BX2 115/...144 2BH1-7 A H16 5,85-24 / 345-415 Y 4,2 / 2,4 Y 63 16 6,95 22-2 / 38-48 Y 4, / 2,3 Y 1 x 2BX2 115/...144 2BH1-7 A H26 5 1,3-24 / 345-415 Y 5,7 / 3,3 Y 63 17 6 1,5 22-2 / 38-48 Y 5,7 / 3,3 Y 1 x 2BX2 115/...144 2BH1 43-7 A H6 5,7-24 / 345-415 Y 3,8 / Y 14 2BH1 43-7 E H6 6,83 22-2 / 38-48 Y 3, / 2,15 Y 65 2 x 2BX2 115/...144 2BH1 43-7 A H16 5,85-24 / 345-415 Y 4,2 / 2,4 Y 17 2BH1 43-7 E H16 6,95 22-2 / 38-48 Y 4, / 2,3 Y 65 2 x 2BX2 115/...144 2BH1 43-7 A H26 5 1,3-24 / 345-415 Y 5,7 / 3,3 Y 18 2BH1 43-7 E H26 6 1,5 22-2 / 38-48 Y 5,7 / 3,3 Y 65 1 x 2BX2 115/...144 2BH1 59-7 A H26 5 1,1-24 / 345-415 Y 7,5 / 4,3 Y 23-6 1,7 22-2 / 38-48 Y 7,6 / 4,4 Y 7 2BH1 5-7 A H6 5,85-24 / 345-415 Y 4,2 / 2,4 Y 2 6,95 22-2 / 38-48 Y 4, / 2,3 Y 7 1 x 2BX2 115/...148 2BH1 5-7 A H16 5 1,3-24 / 345-415 Y 5,7 / 3,3 Y 22 6 1,5 22-2 / 38-48 Y 5,7 / 3,3 Y 7 1 x 2BX2 115/...148 2BH1 5-7 A H26 5 1,6-24 / 345-415 Y 7,5 / 4,3 Y 23 6 2,5 22-2 / 38-48 Y 7,6 / 4,4 Y 7 1 x 2BX2 115/...148 2BH1 5-7 A H36 5-24 / 345-415 Y 9,7 / 5,6 Y 25 6 2,55 22-2 / 38-48 Y 1,3 / 6, Y 7 1 x 2BX2 115/...148 2BH1 53-7 A H16 5 1,3-24 / 345-415 Y 5,7 / 3,3 Y 65 23 2BH1 53-7 E H16 6 1,5 22-2 / 38-48 Y 5,7 / 3,3 Y 71 1 x 2BX2 115/...148 2BH1 53-7 A H26 5 1,6-24 / 345-415 Y 7,5 / 4,3 Y 65 24 2BH1 53-7 E H26 6 2,5 22-2 / 38-48 Y 7,6 / 4,4 Y 71 1 x 2BX2 115/...148 2BH1 53-7 A H36 5-24 / 345-415 Y 9,7 / 5,6 Y 65 26 2BH1 53-7 E H36 6 2,55 22-2 / 38-48 Y 1,3 / 6, Y 71 1 x 2BX2 115/...148 2BH1 69-7 A H26 5-24 / 345-415 Y 12,5 / 7,2 Y 69 36-6 3,45 22-2 / 38-48 Y 12,6 / 7,3 Y 72 2BH1 6-7 A H6 5 1,6-24 / 345-415 Y 8,5 / 4,9 Y 69 27 6 2,5 22-2 / 38-48 Y 8, / 4,6 Y 72 1 x 2BX2 115/...148 2BH1 6-7 A H16 5-24 / 345-415 Y 9,7 / 5,6 Y 69 3 6 2,55 22-2 / 38-48 Y 1,3 / 6, Y 72 1 x 2BX2 115/...148 2BH1 6-7 A H26 5 3, -24 / 345-415 Y 12,5 / 7,2 Y 69 36 6 3,45 22-2 / 38-48 Y 12,6 / 7,3 Y 72 1 x 2BX2 115/...148 2BH1 6-7 A H37 5 4, 345-415 / 6-72 Y 9, / 5,2 Y 69 4 6 4,6 38-48 / 66-72 Y 9, / 5,2 Y 72 1 x 2BX2 115/...148 2BH1 63-7 A H6 5 1,6-24 / 345-415 Y 8,5 / 4,9 Y 7 2 x 2BX2 111/...147 29 2BH1 63-7 E H6 6 2,5 22-2 / 38-48 Y 8, / 4,6 Y 73 3 x 2BX2 115/...148 2BH1 63-7 A H16 5-24 / 345-415 Y 9,7 / 5,6 Y 7 2 x 2BX2 111/...147 32 2BH1 63-7 E H16 6 2,55 22-2 / 38-48 Y 1,3 / 6, Y 73 2 x 2BX2 115/...148 2BH1 63-7 A H26 5 3, -24 / 345-415 Y 12,5 / 7,2 Y 7 37 2BH1 63-7 E H26 6 3,45 22-2 / 38-48 Y 12,6 / 7,3 Y 73 2 x 2BX2 115/...148 2BH1 63-7 A H37 5 4, 345-415 / 6-72 Y 9, / 5,2 Y 7 43 2BH1 63-7 E H37 6 4,6 38-48 / 66-72 Y 9, / 5,2 Y 73 2 x 2BX2 115/...148 E... Gaseinlass auf der Verdichterseite Suction port on compressor side A... Gaseinlass und -Auslass motorseitig (Standard) Suction and discharge port on motor side (standard) Bedingungen siehe Seite 155 See page 155 for conditions applied 44 www.gd-elmorietschle.de Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

5 Hz Auswahldiagramm Selection diagram 5 Ansaugvolumenstrom in m 3 /h Suction capacity in m 3 /h 3 1 2BH163 2BH16 2BH153 2BH143 2BH133 2BH13 2BH11 2BH15 2BH1,7,25 1,6 2BH169,85,85 1,3 2BH149,25,2 2BH159,7,6,4,4,7 1,6 1,6 1 3 1,1 1,3,85 1,3 1,6 3 1,3 3 4 4 Druck Pressure Gesamtdruckdifferenz in mbar Total pressure difference in mbar 6 Hz Auswahldiagramm Selection diagram 5 2BH163 Ansaugvolumenstrom in m 3 /h Suction capacity in m 3 /h 3 1 2BH153 2BH143 2BH133 2BH13 2BH11 1,5,95,83,95 2BH1 2BH149 2,5 2BH16 2BH169 2BH15 2BH159 2,55 3,45 2,5 2,55 2,5 1,5 2,5 1,7,83 1,5,95,29,85 1,5,29,5,23,5,83 3,45 4,6 4,6 3,45 2,55 2,55 1 3 Gesamtdruckdifferenz in mbar Total pressure difference in mbar Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH www.gd-elmorietschle.de 45

Zweistufige Kompressoren mit Dreiphasen-Asynchronmotor; Volumenstrom bis zu 42 m 3 /h Two stage compressors with three phase asynchronous motor; volume flow up to 42 m 3 /h Bestell-Nr. Motor (IP55, Wärmeklasse F) Gewicht Schall- Druckbegrenzungsventil ab Lager lieferbar Fre- Bemessungs- ca. druck- Stück x Typ quenz Leistung Spannung Strom pegel Order No. Motor (IP55, insulation class F) Weight Sound Pressure relief valve available ex stock Fre- rated approx. pressure Items x type quency output voltage current level 2BH1 31-7HH26 2BH1 41-7HH36 2BH1 41-7HH46 2BH1 51-7HH46 2BH1 51-7HH57 2BH1 61-7HH16 2BH1 61-7HH26 2BH1 61-7HH37 2BH1 61-7HH47 2BH1 61-7HH57 Hz kw V A kg db(a) 5,7-24 / 345-415 Y 3,8 / Y 55 1 x 2BX2 111/.143 15 6,83 22-2 / 38-48 Y 3, / 2,15 Y 61 1 x 2BX2 115/.144 5 1,6-24 / 345-415 Y 7,5 / 4,3 Y 66 1 x 2BX2 111/.143 25 6 2,5 22-2 / 38-48 Y 7,6 / 4,4 Y 69 1 x 2BX2 115/.144 5-24 / 345-415 Y 9,7 / 5,6 Y 66 1 x 2BX2 111/.143 27 6 2,55 22-2 / 38-48 Y 1, / 5,8 Y 69 1 x 2BX2 115/.144 5 3, -24 / 345-415 Y 12,5 / 7,2 Y 72 4 6 3,45 22-2 / 38-48 Y 12,6 / 7,3 Y 1 x 2BX2 115/.148 5 4, 345-415 / 6-72 Y 1, / 5,8 Y 72 44 6 4,6 38-48 / 66-72 Y 9,9 / 5,71 Y 1 x 2BX2 115/.148 5-24 / 345-415 Y 9,7 / 5,6 Y 73 43 6 2,55 22-2 / 38-48 Y 1,3 / 6, Y 76 1 x 2BX2 115/.148 5 3, -24 / 345-415 Y 12,5 / 7,2 Y 73 48 6 3,45 22-2 / 38-48 Y 12,6 / 7,3 Y 76 1 x 2BX2 115/.148 5 4,3 345-415 / 6-72 Y 1, / 5,2 Y 73 54 6 4,8 38-48 / 66-72 Y 1,4 / 6, Y 76 1 x 2BX2 115/.148 5 345-415 / 6-72 Y 13,3 / 7,7 Y 73 66 6 6,3 38-48 / 66-72Y 13,3 / 7,7 Y 76 1 x 2BX2 115/.148 5 7,5 345-415 / 6-72 Y 16,7 / 9,6 Y 73 73 6 8,6 38-48 / 66-72 Y 17,3 / 1, Y 76 1 x 2BX2 115/.148 Bedingungen siehe Seite 155 See page 155 for conditions applied 46 www.gd-elmorietschle.de Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

5 Hz Auswahldiagramm Selection diagram 5 Ansaugvolumenstrom in m 3 /h Suction capacity in m 3 /h 3 1 2BH161 2BH151 2BH141 2BH131,7 3 1,6 4,3 1 3 5 6 7 8 3 4 7,5 Druck Pressure Gesamtdruckdifferenz in mbar Total pressure difference in mbar 6 Hz Auswahldiagramm Selection diagram 5 Ansaugvolumenstrom in m 3 /h Suction capacity in m 3 /h 3 1 2BH161 2BH151 2BH141 2BH131 2,55 3,45,83 2,5 4,8 3,45 6,3 2,55 4,6 8,6 1 3 5 6 7 8 Gesamtdruckdifferenz in mbar Total pressure difference in mbar Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH www.gd-elmorietschle.de 47

Ein- und zweistufige Kompressoren mit Dreiphasen-Asynchronmotor; Volumenstrom bis zu 88 m 3 /h Single and two stage compressors with three phase asynchronous motor; volume flow up to 88 m 3 /h Bestell-Nr. Motor (IP55, Wärmeklasse F) Gewicht Schall- Druckbegrenzungsventil ab Lager lieferbar Fre- Bemessungs- ca. druck- Stück x Typ quenz Leistung Spannung Strom pegel Order No. Motor (IP55, insulation class F) Weight Sound Pressure relief valve available ex stock Fre- rated approx. pressure Items x type quency output voltage current level 2BH1-7GH37 2BH1-7GH47 2BH1-7GH57 2BH1 8-7AH7 2BH1 8-7AH17 2BH1 8-7AH27 2BH1 81-7HH17 2BH1 81-7HH27 2BH1 81-7HH37 2BH1 81-7HH47 2BH1 83-7AH7 2BH1 83-7AH17 2BH1 83-7AH27 Hz kw V A kg db(a) 5 4, 345-415 / 6-72 Y 9, / 5,2 Y 54 6 4,6 38-48 / 66-72Y 9, / 5,2 Y 78 2 x 2BX2 115/...148 5 345-415 / 6-72 Y 13,3 / 7,7 Y 69 6 6,3 38-48 / 66-72Y 13,3 / 7,7 Y 78 2 x 2BX2 115/...148 5 7,5 345-415 / 6-72 Y 16,7 / 9,6 Y 6 8,6 38-48 / 66-72 Y 17,3 / 1, Y 78 2 x 2BX2 115/...148 5 4, 345-415 / 6-72 Y 9, / 5,2 Y 7 1 x 2BX4 1/...841 117 6 4,6 38-48 / 66-72 Y 9, / 5,2 Y 1 x 2BX4 5/...845 5 345-415 / 6-72 Y 13,3 / 7,7 Y 1 x 2BX4 1/...841 126 6 6,3 38-48 / 66-72 Y 13,3 / 7,7 Y 1 x 2BX4 5/...845 5 7,5 345-415 / 6-72 Y 16,7 / 9,6 Y 7 1 x 2BX4 1/...841 132 6 8,6 38-48 / 66-72 Y 17,3 / 1, Y 1 x 2BX4 5/...845 5 345-415 / 6-72 Y 13,3 / 7,7 Y 1 x 2BX4 1/...841 171 6 6,3 38-48 / 66-72 Y 13,3 / 7,7 Y 78 1 x 2BX4 5/...845 5 7,5 345-415 / 6-72 Y 16,7 / 9,6 Y 1 x 2BX4 1/...841 177 6 8,6 38-48 / 66-72 Y 17,3 / 1, Y 78 1 x 2BX4 5/...845 5 11, 345-415 / 6-72 Y 28, / 16,2 Y 1 x 2BX4 1/...841 23 6 12,6 38-48 / 66-72 Y 29, / 16,7 Y 78 1 x 2BX4 5/...845 5 15, 345-415 / 6-72 Y 32,5 / 18,8 Y 1 x 2BX4 1/...841 215 6 17,3 38-48 / 66-72 Y 34,5 / 19,9 Y 78 1 x 2BX4 5/...845 5 4, 345-415 / 6-72 Y 9, / 5,2 Y 7 1 x 2BX4 1/...851 12 6 4,6 38-48 / 66-72 Y 9, / 5,2 Y 1 x 2BX4 5/...855 5 345-415 / 6-72 Y 13,3 / 7,7 Y 7 1 x 2BX4 1/...851 129 6 6,3 38-48 / 66-72 Y 13,3 / 7,7 Y 1 x 2BX4 5/...855 5 7,5 345-415 / 6-72 Y 16,7 / 9,6 Y 7 1 x 2BX4 1/...851 135 6 8,6 38-48 / 66-72 Y 17,3 / 1, Y 1 x 2BX4 5/...855 Bedingungen siehe Seite 155 See page 155 for conditions applied 48 www.gd-elmorietschle.de Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

5 Hz Auswahldiagramm Selection diagram 9 8 Ansaugvolumenstrom in m 3 /h Suction capacity in m 3 /h 7 6 5 3 1 2BH183 2BH18 4 4 4 2BH1 7,5 7,5 7,5 2BH181 1 3 5 6 7 8 7,5 11 15 Druck Pressure Gesamtdruckdifferenz in mbar Total pressure difference in mbar 6 Hz Auswahldiagramm Selection diagram 9 8 2BH183 Ansaugvolumenstrom in m 3 /h Suction capacity in m 3 /h 7 6 5 3 1 4,6 6,3 4,6 4,6 6,3 6,3 2BH1 8,6 6,3 2BH18 8,6 8,6 8,6 2BH181 12,6 17,3 1 3 5 6 7 8 Gesamtdruckdifferenz in mbar Total pressure difference in mbar Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH www.gd-elmorietschle.de 49

/ G-BH9 Ein- und zweistufige Kompressoren mit Dreiphasen-Asynchronmotor; Volumenstrom bis zu 2.65 m 3 /h Single and two stage compressors with three phase asynchronous motor; volume flow up to 2,65 m 3 /h Bestell-Nr. Motor (IP55, Wärmeklasse F) Gewicht Schall- Druckbegrenzungsventil ab Lager lieferbar Fre- Bemessungs- ca. druck- Stück x Typ quenz Leistung Spannung Strom pegel Order No. Motor (IP55, insulation class F) Weight Sound Pressure relief valve available ex stock Fre- rated approx. pressure Items x type quency output voltage current level 2BH1 9-7AH7 2BH1 9-7AH17 2BH1 9-7AH27 2BH1 9-7AH37 2BH1 91-7HH17 2BH1 91-7HH27 2BH1 91-7HH37 2BH1 91-7HH47 2BH1 93-7AH7 2BH1 93-7AH17 5 2BH1 93-7AH27 2BH1 93-7AH37 2BH1 94-7BH27 2BH1 94-7BH37 2BH1 94-7BH47 Hz kw V A kg db(a) 5 8,5 345-415 / 6-72 Y 18,2 / 1,5 Y 2 x 2BX4 1/.881 179 6 9,8 38-48 / 66-72 Y 18,2 / 1,5 Y 79 2 x 2BX4 5/.885 5 12,5 345-415 / 6-72 Y 28, / 16,2 Y 1 x 2BX4 1/...861 198 6 14,5 38-48 / 66-72 Y 29, / 16,7 Y 79 1 x 2BX4 5/...865 5 16,5 345-415 / 6-72 Y 35, / 2 Y 1 x 2BX4 1/...861 21 6 19, 38-48 / 66-72 Y 36,5 / 21, Y 79 1 x 2BX4 5/...865 5 18,5 345-415 / 6-72 Y 37, / 21, Y 1 x 2BX4 1/...861 21 6 21,3 38-48 / 66-72 Y 39, / 22,5 Y 79 1 x 2BX4 5/...865 5 12,5 345-415 / 6-72 Y 28, / 16,2 Y 1 x 2BX4 1/...861 281 6 14,5 38-48 / 66-72 Y 29, / 16,7 Y 84 1 x 2BX4 5/...865 5 16,5 345-415 / 6-72 Y 32, / 17,3 Y 1 x 2BX4 1/...861 295 6 19, 38-48 / 66-72 Y 32, / 17,3 Y 84 1 x 2BX4 5/...865 5 2, 345-415 / 6-72 Y 4, / 23, Y 1 x 2BX4 1/...861 36 6 23, 38-48 / 66-72 Y 42, / 24,2 Y 84 1 x 2BX4 5/...865 5 25, 345-415 / 6-72 Y 52, / 3, Y 1 x 2BX4 1/...861 316 6 29, 38-48 / 66-72 Y 52, / 3, Y 84 1 x 2BX4 5/...865 5 8,5 345-415 / 6-72 Y 18,2 / 1,5 Y 2 x 2BX4 1/...881 179 6 9,8 38-48 / 66-72 Y 18,2 / 1,5 Y 8 2 x 2BX4 5/...885 12,5 345-415 / 6-72 Y 28, / 16,2 Y 2 x 2BX4 1/...881 198 14,5 38-48 / 66-72 Y 29, / 16,7 Y 8 2 x 2BX4 5/...885 5 15 345-415 / 6-72 Y 32, / 17,3 Y 1 x 2BX4 1/...861 27 6 17,5 38-48 / 66-72 Y 32, / 17,3 Y 8 1 x 2BX4 5/...865 5 18,5 345-415 / 6-72 Y 37, / 21, Y 1 x 2BX4 1/...861 21 6 21,3 38-48 / 66-72 Y 39, / 22,5 Y 8 1 x 2BX4 5/...865 5 15, 345-415 / 6-72 Y 32, / 17,3 Y 2 x 2BX4 1/...881 2 6 17,5 38-48 / 66-72 Y 32, / 17,3 Y 84-5 2, 345-415 / 6-72 Y 4, / 23, Y 2 x 2BX4 1/...881 314 6 23, 38-48 / 66-72 Y 42, / 24,2 Y 84 2 x 2BX4 5/...885 5 25, 345-415 / 6-72 Y 52, / 3, Y 2 x 2BX4 1/...881 324 6 29, 38-48 / 66-72 Y 52, / 3, Y 84 2 x 2BX4 5/...885 5 15, 345-415 / 6-72 Y 32, / 17,3 Y 2 x 2BX4 1/...871 2BH1 943-7GH27 1) 33 6 17,5 38-48 / 66-72 Y 32, / 17,3 Y 84 2 x 2BX4 5/...8 5 2, 345-415 / 6-72 Y 4, / 23, Y 2 x 2BX4 1/...871 2BH1 943-7GH37 1) 339 6 23, 38-48 / 66-72 Y 42, / 24,2 Y 84 2 x 2BX4 5/...8 5 25, 345-415 / 6-72 Y 52, / 3, Y 2 x 2BX4 1/...871 2BH1 943-7GH47 1) 349 6 29, 38-48 / 66-72 Y 52, / 3, Y 84 2 x 2BX4 5/...8 2BH9 23-1AAPQ7-AA 2BH9 23-1AAPR7-AA IE2 5 15, 35-45 / 61-725 Y 3,5 / 17,3 Y 79 2 x 2BX4 1 165 6 17,3-5 / 69-725 Y 29,5 / 17, Y 81 3 x 2BX4 5 5 18,5 35-45 / 61-725 Y 37, / 21, Y 79 2 x 2BX4 1 185 6 21,3-5 / 69-725 Y 36,5 / 21, Y 81 3 x 2BX4 5 1) nur Deckelaufstellung möglich mounting on the end-casing only Bedingungen siehe Seite 155 See page 155 for conditions applied 5 www.gd-elmorietschle.de Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

/ G-BH9 5 Hz Auswahldiagramm Selection diagram 28 26 2 Ansaugvolumenstrom in m 3 /h Suction capacity in m 3 /h 2 18 16 1 1 1 8 6 2BH9 23 2BH1943 2BH194 2BH193 2BH191 2BH19 15 8,5 15 15 18,5 12,5 8,5 2 2 15 12,5 12,5 25 25 16,5 18,5 1 3 5 6 16,5 18,5 2 25 Druck Pressure Gesamtdruckdifferenz in mbar Total pressure difference in mbar 6 Hz Auswahldiagramm Selection diagram 28 26 2 2BH9 23 2BH1943 17,3 Ansaugvolumenstrom in m 3 /h Suction capacity in m 3 /h 2 18 16 1 1 1 8 6 2BH194 17,5 2BH193 2BH191 2BH19 9,8 21,3 17,5 23 14,5 9,8 23 17,5 14,5 29 29 14,5 19 21,3 19, 23 21,3 29 1 3 5 6 Gesamtdruckdifferenz in mbar Total pressure difference in mbar Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH www.gd-elmorietschle.de 51

HT Einstufiger Kompressor für Hochtemperaturbetrieb, mit Dreiphasen-Asynchronmotor; Volumenstrom bis zu 1.58 m 3 /h Single stage compressor for high temperature operation with three phase asynchronous motor; volume flow up to 1,58 m 3 /h Bestell-Nr. Motor (IP55, Wärmeklasse F) Gewicht ca. Schalldruck- Druckbegrenzungsventil Frequenz Bemessungs- pegel Stück x Typ Leistung Spannung Strom Order No. Motor (IP55, insulation class F) Weight approx. Sound pressure Pressure relief valve Frequency rated level Items x type output voltage current Hz kw V A kg db(a) 2BH1 8-6AH17 5 4,8 345-415 Δ / 6-72 Y 12, Δ / 6,9 Y 7 1 x 2BX4 1/.841 137 6 38-48 Δ / 66-72 Y 11,7 Δ / 6,8 Y 1 x 2BX4 5/.845 2BH1 8-6AH27 5 6,6 345-415 Δ / 6-72 Y 15, Δ / 8,7 Y 7 1 x 2BX4 1/.841 143 6 7,4 38-48 Δ / 66-72 Y 14,3 Δ / 8,3 Y 1 x 2BX4 5/.845 2BH1 83-6AH17 5 4,8 345-415 Δ / 6-72 Y 12, Δ / 6,9 Y 7 1 x 2BX4 1/.851 14 6 38-48 Δ / 66-72 Y 11,7 Δ / 6,8 Y 1 x 2BX4 5/.855 2BH1 83-6AH27 5 6,5 345-415 Δ / 6-72 Y 15, Δ / 8,7 Y 7 1 x 2BX4 1/.851 146 6 7,4 38-48 Δ / 66-72 Y 14,3 Δ / 8,3 Y 1 x 2BX4 5/.855 2BH1 9-6AH17 5 9, 345-415 Δ / 6-72 Y 21,5 Δ / 12,4 Y 1 x 2BX4 1/.861 215 6 11, 38-48 Δ / 66-72 Y 21, Δ / 12,1 Y 79 1 x 2BX4 5/.865 2BH1 9-6AH37 5 13,3 345-415 Δ / 6-72 Y 3, Δ / 17,3 Y 1 x 2BX4 1/.861 227 6 16, 38-48 Δ / 66-72 Y 3, Δ / 17,3 Y 79 1 x 2BX4 5/.865 2BH1 93-6AH17 5 9, 345-415 Δ / 6-72 Y 21,5 Δ / 12,4 Y 1 x 2BX4 1/.881 215 6 11, 38-48 Δ / 66-72 Y 21, Δ / 12,1 Y 8 1 x 2BX4 5/.885 2BH1 93-6AH37 5 13,3 345-415 Δ / 6-72 Y 3, Δ / 17,3 Y 1 x 2BX2 1/.861 227 6 16, 38-48 Δ / 66-72 Y 3, Δ / 17,3 Y 8 1 x 2BX2 5/.865 Die Hochtemperatur-Seitenkanalverdichter von Elmo Rietschle sind für Fördergastemperaturen bis zu C am Druckstutzen geeignet. The new Elmo Rietschle high temperature side channel blowers are designed to convey gases up to C. Kennlinien: Die Kennlinien der Hochtemperaturverdichter gelten für Förderung von Luft von 15 C, bzw. 16 C am Saugstutzen bei einem Luftdruck von 1.13 mbar mit einer Toleranz von ±1 %. Die Gesamtdruckdifferenzen gelten bis zu einer Umgebungstemperatur von 4 C. Curves: The high temperature performance curves are valid for pumping air at 15 C, resp. 16 C at the inlet flanges with an air pressure of 1,13 mbar and a tolerance of ±1 %. The total pressure differences are valid up to an intake and ambient temperature of 4 C. 52 www.gd-elmorietschle.de Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

HT 5 Hz Auswahldiagramm Selection diagram 16 Ansaugtemperatur Suction temperature t1 =15 C 1 Ansaugtemperatur Suction temperature t1 =16 C Ansaugvolumenstrom in m 3 /h Suction capacity in m 3 /h 1 1 8 6 2BH193 2BH19 2BH183 2BH18 9, 9, 4,8 4,8 6,5 9, 9, 13,3 13,3 6,5 4,8 4,8 6,6 13,3 6,6 13,3 Druck Pressure 1 3 5 Gesamtdruckdifferenz in mbar Total pressure difference in mbar 6 Hz Auswahldiagramm Selection diagram 16 1 2BH193 Ansaugtemperatur Suction temperature t1 =15 C Ansaugtemperatur Suction temperature t1 =16 C 11, Ansaugvolumenstrom in m 3 /h Suction capacity in m 3 /h 1 1 8 6 2BH19 2BH183 2BH18 11, 16, 11, 7,4 11, 16, 7,4 16, 7,4 7,4 16, 1 3 5 Gesamtdruckdifferenz in mbar Total pressure difference in mbar Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH www.gd-elmorietschle.de 53