PS Bauartgepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 2000000000
SPECIFICATION MODE OUTPUT WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION OTHERS NOTE SAFETY STANDARDS MTBF DIMENSION DRA--12 CONSTANT CURRENT REGION 3~12V RATED CURRENT 3.34A CURRENT RANGE 0 ~ 3.34A RATED POWER.08W RIPPE & NOISE (max.) Note.2 120mVp-p VOTAGE ADJ. RANGE 12 ~ 15V VOTAGE TOERANCE Note.3 ±1.0% -30 ~ +70 (Refer to "Derating Curve") 20 ~ RH non-condensing - ~ +85, 10 ~ 95% RH ± 0.03%/ (0 ~ 55 ) on output 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes U60950-1, TUV EN60950-1 approved Compliance to EN55032 (CISPR32) Class B, EN60-3-2,-3 Compliance to EN60-4-2,3,4,5,6,8,11, EN55024, EN61204-3, light industry level, criteria A 439.3K hrs min. MI-HDBK-217F (25 ) *90*mm (W*H*D) DRA--24 3~24V 1.7A 0 ~ 1.7A.8W 150mVp-p 24 ~ 30V ±1.0% INE REGUATION OAD REGUATION SETUP, RISE TIME Note.4 0ms, 90ms/230VAC 800ms, 90ms/115VAC at full load HOD UP TIME (Typ.) 50ms/230VAC 10ms/115VAC at full load VOTAGE RANGE FREQUENCY RANGE 90 ~ 264VAC 47 ~ 63Hz 127 ~ 370VDC [DC input operation possible by connecting AC/(+), AC/N(-)] INPUT EFFICIENCY (Typ.) 85% 87% AC CURRENT (Typ.) 0.8A/115VAC 0.6A/230VAC INRUSH CURRENT (Typ.) COD START 30A/115VAC 60A/230VAC PROTECTION OVEROAD 95 ~ 108% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed OVER VOTAGE 14.49 ~ 18.63V 28.98 ~ 37.26V Protection type : Shut down o/p voltage, re-power on to recover SAFETY & EMC (Note 5) DC VOTAGE WITHSTAND VOTAGE ISOATION RESISTANCE EMC EMISSION EMC IMMUNITY 12V I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:M Ohms / 500VDC / 25 / RH PACKING 0.3Kg; 42pcs/13.6Kg/0.82CUFT 24V
Block Diagram I/P EMI FITER RECTIFIERS & FITER POWER SWITCHING RECTIFIERS & FITER O.C.P. +V -V FG O..P. CONTRO DETECTION CIRCUIT O.V.P. Derating Curve Static Characteristics 80 60 230VAC Input only 90 80 70 OAD (%) 20 OAD (%) 60 50-30 -20 0 15 30 50 55 60 70 (VERTICA) 90 125 135 145 155 165 175 180 200 230 264 AMBIENT TEMPERATURE ( ) INPUT VOTAGE (V) 60Hz OUTPUT CURRENT ADJUSTMENT OPERATION Built-in 3 in 1 current adjustment function. Output constant current level can be adjusted by applying 1 ~ 10Vdc, 10V PWM signal or resistance between and. Please DO NOT connect "" to "-V". Reference resistance value for output current adjustment (Typical) Resistance value Single Power supply Multiple Power supplies (N=Power supply quantity for simultaneous current adjustment control) 10KΩ 1 ~ 10Vdc for output current adjustment (Typical) Applied Source 60KΩ 10K Ω/N 20K Ω/N 30K Ω/N K Ω/N 50K Ω/N 60K Ω/N 70K Ω/N 80K Ω/N 90K Ω/N K Ω/N ----- 102%~108% 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V 20KΩ 30KΩ KΩ 50KΩ 70KΩ 80KΩ 90KΩ KΩ 102%~108% 10V PWM signal for output current adjustment (Typical): Frequency range :Hz ~ 3KHz Duty value 102%~108%
Using the current adjustment function can not adjust the output current to 0A. Please refer to the connection method below to adjust the output current to 0A. OAD 10K~K Ohms resistance 1~10V DC Voltage 10V PWM Signal Adjuster +V +V -V -V DC OK + +V ADJ Switch N Relay FG N DRIVING METHODS OF APPICATIONS The power supply may either work in "constant voltage mode or constant current mode" Rated output voltage (A) Constant Voltage area (B) Constant Current area In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. Should there be any compatibility issues, please contact MEAN WE. 3V Vo(v) (C) Hiccup Protection 50 Io (%)
35 W Single Output Switching Power Supply Mechanical Specification Case No.962A Unit:mm 5 5 5 5 5 +V +V -V -V DC OK + 90 +V ADJ N 7.5 7.5 Installation Instruction This series fits DIN rail TS35/7.5 or TS35/15. For installation details, please refer to the Instruction manual. ADMISSIBE DIN rail:ts35/7.5 OR TS35/15 (For reference only. Not included with unit.) Back View Installation Manual Please refer to : http://www.meanwell.com/manual.html