KERAJAAN MALAYSIA JABATAN AGAMA ISLAM WILAYAH PERSEKUTUAN

Σχετικά έγγραφα
20/01/ of 8 TOW SSD v3. C 2.78AC Σ Cumul. A*C. Tc 1 =A14+1 =B14+1 =C14+1 =D14+1 =E14+1 =F14+1 =G14+1 =H14+1 =I14+1 =J14+1 =K14+1

Project: Brimsmore, Ye... Job no: C08127 Designed By kristian Checked By Network W Network Design Table for OUTFALL B.SWS

DETERMINATION OF DYNAMIC CHARACTERISTICS OF A 2DOF SYSTEM. by Zoran VARGA, Ms.C.E.

UDZ Swirl diffuser. Product facts. Quick-selection. Swirl diffuser UDZ. Product code example:

Th, Ra, Rn, Po, Pb, Bi, & Tl K x-rays. Rn Kα1. Rn Kα2. 93( 227 Th)/Rn Kβ3. Ra Kα2. Po Kα2 /Bi K α1 79( 227 Th)/Po Kα1. Ra Kα1 /Bi K β1.

RECIPROCATING COMPRESSOR CALCULATION SHEET

Type 441 DIN 442 DIN. Capacities. Flanged Safety Relief Valves spring loaded. The-Safety-Valve.com LWN E

Aluminum Electrolytic Capacitors (Large Can Type)

DuPont Suva 95 Refrigerant

LUMINAIRE PHOTOMETRIC TEST REPORT

MOTROL. COMMISSION OF MOTORIZATION AND ENERGETICS IN AGRICULTURE 2014, Vol. 16, No. 5,

Type. Capacities. 441, 442 Full nozzle DIN. Flanged Safety Relief Valves spring loaded. The-Safety-Valve.com LWN E

Smaller. 6.3 to 100 After 1 minute's application of rated voltage at 20 C, leakage current is. not more than 0.03CV or 4 (µa), whichever is greater.

RECIPROCATING COMPRESSOR CALCULATION SHEET ISOTHERMAL COMPRESSION Gas properties, flowrate and conditions. Compressor Calculation Sheet

Chapter 7 Transformations of Stress and Strain

5.0 DESIGN CALCULATIONS

Aluminum Electrolytic Capacitors

Data sheet Thick Film Chip Resistor 5% - RS Series 0201/0402/0603/0805/1206

Ingenieurbüro Frank Blasek - Beratender Ingenieur Am Kohlhof 10, Osterholz-Scharmbeck Tel: 04791/ Fax: 04791/

Ingenieurbüro Frank Blasek - Beratender Ingenieur Am Kohlhof 10, Osterholz-Scharmbeck Tel: 04791/ Fax: 04791/

NMBTC.COM /

Technical Information T-9100 SI. Suva. refrigerants. Thermodynamic Properties of. Suva Refrigerant [R-410A (50/50)]

Calculating the propagation delay of coaxial cable

SAMSUNG ELECTRONICS CO., LTD TEST REPORT SAMSUNG ELECTRONICS CO., LTD. 1, Samsung-Ro, Giheung-Gu, Yongin-Si, Gyeonggi-Do 17113, Korea

DuPont Suva. DuPont. Thermodynamic Properties of. Refrigerant (R-410A) Technical Information. refrigerants T-410A ENG

DuPont Suva 95 Refrigerant

Monolithic Crystal Filters (M.C.F.)

Thin Film Chip Resistors

LR Series Metal Alloy Low-Resistance Resistor

APPENDIX 1: Gravity Load Calculations. SELF WEIGHT: Slab: 150psf * 8 thick slab / 12 per foot = 100psf ROOF LIVE LOAD:

STRUCTURAL CALCULATIONS FOR SUSPENDED BUS SYSTEM SEISMIC SUPPORTS SEISMIC SUPPORT GUIDELINES

Consolidated Drained

Περιοχή διαγωνισμού Rethink Athens

CHAPTER 48 APPLICATIONS OF MATRICES AND DETERMINANTS

CSR series. Thick Film Chip Resistor Current Sensing Type FEATURE PART NUMBERING SYSTEM ELECTRICAL CHARACTERISTICS

DETERMINATION OF THERMAL PERFORMANCE OF GLAZED LIQUID HEATING SOLAR COLLECTORS

Study on Re-adhesion control by monitoring excessive angular momentum in electric railway traction

Type. Capacities. Flanged Safety Relief Valves spring loaded. The-Safety-Valve.com LWN E

Math 6 SL Probability Distributions Practice Test Mark Scheme

Enantioselective Organocatalytic Michael Addition of Isorhodanines. to α, β-unsaturated Aldehydes

DESIGN OF MACHINERY SOLUTION MANUAL h in h 4 0.

LS series ALUMINUM ELECTROLYTIC CAPACITORS CAT.8100D. Specifications. Drawing. Type numbering system ( Example : 200V 390µF)

Photometric Data of Lamp

Thi=Τ1. Thο=Τ2. Tci=Τ3. Tco=Τ4. Thm=Τ5. Tcm=Τ6

ΠΑΝΕΠΙΣΤΗΜΙΟ ΠΑΤΡΩΝ ΤΜΗΜΑ ΗΛΕΚΤΡΟΛΟΓΩΝ ΜΗΧΑΝΙΚΩΝ ΚΑΙ ΤΕΧΝΟΛΟΓΙΑΣ ΥΠΟΛΟΓΙΣΤΩΝ ΤΟΜΕΑΣ ΣΥΣΤΗΜΑΤΩΝ ΗΛΕΚΤΡΙΚΗΣ ΕΝΕΡΓΕΙΑΣ

Surface Mount Multilayer Chip Capacitors for Commodity Solutions

1 (forward modeling) 2 (data-driven modeling) e- Quest EnergyPlus DeST 1.1. {X t } ARMA. S.Sp. Pappas [4]

Daewoo Technopark A-403, Dodang-dong, Wonmi-gu, Bucheon-city, Gyeonggido, Korea LM-80 Test Report

RC series Thick Film Chip Resistor

Mean bond enthalpy Standard enthalpy of formation Bond N H N N N N H O O O

Study on the Strengthen Method of Masonry Structure by Steel Truss for Collapse Prevention

; +302 ; +313; +320,.

Creative TEchnology Provider

ΠΑΝΕΠΙΣΤΗΜΙΟ ΠΑΤΡΩΝ ΠΟΛΥΤΕΧΝΙΚΗ ΣΧΟΛΗ ΤΜΗΜΑ ΜΗΧΑΝΙΚΩΝ Η/Υ & ΠΛΗΡΟΦΟΡΙΚΗΣ. του Γεράσιμου Τουλιάτου ΑΜ: 697

First Sensor Quad APD Data Sheet Part Description QA TO Order #

RECIPROCATING COMPRESSOR CALCULATION SHEET

Strain gauge and rosettes

Mock Exam 7. 1 Hong Kong Educational Publishing Company. Section A 1. Reference: HKDSE Math M Q2 (a) (1 + kx) n 1M + 1A = (1) =

RANGE OF APPLICATION HYDRO DL. ver sion 1.1 / web:

the total number of electrons passing through the lamp.

Precision Metal Film Fixed Resistor Axial Leaded

Photo-Induced Self-Assembly of Pt(II)-Linked Rings and Cages via the Photolabilization of a Pt(II) Pyridine Bond

Approximation of distance between locations on earth given by latitude and longitude

! "##!!$%$&'(&) "&$## $%& '!($( +,' *- $ + $.$ $ $ / /

Οι απόψεις και τα συμπεράσματα που περιέχονται σε αυτό το έγγραφο, εκφράζουν τον συγγραφέα και δεν πρέπει να ερμηνευτεί ότι αντιπροσωπεύουν τις

CSK series. Current Sensing Chip Resistor. Features. Applications. Construction FAITHFUL LINK

The Simply Typed Lambda Calculus

Electronic Supplementary Information (ESI)

CONSULTING Engineering Calculation Sheet

Second ESIA Amendment - GCS00 Kipoi. Annex 3 - Correspondence with Authorities and Stakeholders

INPAQ Global RF/Component Solutions

5.4 The Poisson Distribution.

STEAM TABLES. Mollier Diagram

ΑΥΤΟΜΑΤΟΠΟΙΗΣΗ ΜΟΝΑΔΑΣ ΘΡΑΥΣΤΗΡΑ ΜΕ ΧΡΗΣΗ P.L.C. AUTOMATION OF A CRUSHER MODULE USING P.L.C.

MRL HYDRAULIC LIFTS TYPE:

ΠΑΝΕΠΙΣΤΗΜΙΟ ΠΑΤΡΩΝ ΤΜΗΜΑ ΗΛΕΚΤΡΟΛΟΓΩΝ ΜΗΧΑΝΙΚΩΝ ΚΑΙ ΤΕΧΝΟΛΟΓΙΑΣ ΥΠΟΛΟΓΙΣΤΩΝ ΤΟΜΕΑΣ ΣΥΣΤΗΜΑΤΩΝ ΗΛΕΚΤΡΙΚΗΣ ΕΝΕΡΓΕΙΑΣ

Submittal Data Sheet Wilo Stratos Z - High Efficiency Domestic Hot Water Circulator

Bulletin 1489 UL489 Circuit Breakers

1. Ηλεκτρικό μαύρο κουτί: Αισθητήρας μετατόπισης με βάση τη χωρητικότητα

TUBO LED T8 LLUMOR PROLED 25W 150CM

Biodiesel quality and EN 14214:2012

VBA Microsoft Excel. J. Comput. Chem. Jpn., Vol. 5, No. 1, pp (2006)

Instruction Execution Times

TRIAXIAL TEST, CORPS OF ENGINEERS FORMAT

Θωμάς ΣΑΛΟΝΙΚΙΟΣ 1, Χρήστος ΚΑΡΑΚΩΣΤΑΣ 2, Βασίλειος ΛΕΚΙΔΗΣ 2, Μίλτων ΔΗΜΟΣΘΕΝΟΥΣ 1, Τριαντάφυλλος ΜΑΚΑΡΙΟΣ 3,

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 9

EPL 603 TOPICS IN SOFTWARE ENGINEERING. Lab 5: Component Adaptation Environment (COPE)

ΑΝΩΤΑΤΗ ΣΧΟΛΗ ΠΑΙ ΑΓΩΓΙΚΗΣ ΚΑΙ ΤΕΧΝΟΛΟΓΙΚΗΣ ΕΚΠΑΙ ΕΥΣΗΣ ΠΑΡΑΔΟΤΕΟ ΕΠΙΣΤΗΜΟΝΙΚΗ ΕΡΓΑΣΙΑ ΣΕ ΔΙΕΘΝΕΣ ΕΠΙΣΤΗΜΟΝΙΚΟ ΠΕΡΙΟΔΙΚΟ

NKT NTC Thermistor. Negative Temperature Coefficient Thermistor FEATURES

Magnet Wire General Engineering Data Bare and Film Insulated Copper and Aluminum

Fused Bis-Benzothiadiazoles as Electron Acceptors

Design Method of Ball Mill by Discrete Element Method

[2] T.S.G. Peiris and R.O. Thattil, An Alternative Model to Estimate Solar Radiation

Rod End > Spherical Bearings Product Overview

Metal Oxide Varistors (MOV) Data Sheet

Notes on the Open Economy

THICK FILM LEAD FREE CHIP RESISTORS

Assalamu `alaikum wr. wb.

Potential Dividers. 46 minutes. 46 marks. Page 1 of 11

LUNGOO R. Control Engineering for Development of a Mechanical Ventilator for ICU Use Spontaneous Breathing Lung Simulator LUNGOO

Transcript:

KERAJAAN MALAYSIA JABATAN AGAMA ISLAM WILAYAH PERSEKUTUAN CADANGAN PEMBINAAN SEMULA MASJID AR-RAHIMAH KG. PANDAN, KUALA LUMPUR YANG MENGANDUNGI SEBUAH MASJID 3 TINGKAT, RUMAH KAKITANGAN, DEWAN SERBAGUNA / TASKA & 2 UNIT RUMAH SAMPAH DI ATAS LOT-LOT 4341, 5589 & SEBAHAGIAN RIZAB KERAJAAN, MUKIM AMPANG, WILAYAH PERSEKUTUAN KUALA LUMPUR LAPORAN REKABENTUK (WATER RETICULATION) JANUARI 2015 DEISEDIAKAN OLEH: JURUTERA PERUNDING MARAK BERSEKUTU SDN. BHD. No.48-C, Jalan Suarasa 8/4, Bandar Tun Hussein Onn, 43200, Cheras, Selangor Tel: 03-9080 2979 / 5979 Fax: 03-9080 5929 Email: jpmarakbersekutu@gmail.com

CADANGAN PEMBINAAN SEMULA MASJID AR-RAHIMAH KG. PANDAN, KUALA LUMPUR YANG MENGANDUNGI SEBUAH MASJID 3 TINGKAT, RUMAH KAKITANGAN, DEWAN SERBAGUNA / TASKA & 2 UNIT RUMAH SAMPAH DI ATAS LOT-LOT 4341, 5589 & SEBAHAGIAN RIZAB KERAJAAN, MUKIM AMPANG, WILAYAH PERSEKUTUAN KUALA LUMPUR UNTUK TETUAN JABATAN AGAMA ISLAM WILAYAH PERSEKUTUAN NO CONTENTS 1 BACKGROUND CALCULATION OPEN SYSTEM 2 a) DOMESTIC SYSTEM b) HYDRANT SYSTEM APPENDIX 3 a) TABLE FOR WATER DEMAND b) TABLE OF PEAK FACTOR c) DRAWING d) APPROVAL LETTER FROM SYABAS

ENGINEERING REPORT 1.0 GENERAL 1.1 Project Introduction & Site Location The owner Majlis Agama Islam Wilayah Persekutuan is proposed project site is located on Lot - lot 4341, 5589 and government lot, Mukim of Ampang, Wilayah Persekutuan Kuala Lumpur The total project area is 1.44 acres ( i.e., 5,850 m²). The locality of the project site falls under the jurisdiction of Dewan Bandaraya Kuala Lumpur. The location of the site is attached 1.2 Design Reference & Calculations a) The design is complying with the Water reticulation system design used by Syarikat Bekalan Air Selangor Sdn Bhd,SYABAS Guidelines b) All analysis for water reticulation by Loop Method applied (Hardy-Cross method) c) Data ODL = 80.0 m (from SYABAS) at existing pipe d) Total Water Demands in gallon per day ( refer to Table 1 = Average Water Demand (gpd)) so, total water demand for this MASJID= 65,200 gal/day e) Friction Loss Using Hazen-William Formula Roughness Coefficient, C = 130 (HDPE) refer data pipe Diameter of Pipes, D = 150mm (for all pipes) Table data pipe :- Q = k. C. A. R 0.63. S 0.54 dengan Q = Kadar aliran (m 3 /s) C = Pekali kekasaran Hazen-Williams (tiada unit) A = Luas aliran (m 2 ) R = Radius hidraulik (m) k = Pemalar (0.85 untuk unit SI)

1.3 Design Flow Peak flow have be determined with formula as follow Peak Flow = Peak Factor x Average Flow Q peak = f x Q average Where = f = peak coefficient. Peak coefficient value can determine according to below table: - a) 1.2 = Peak flow factor for design of pipe from tap-off point to elevated water tank / suction tank b) 2.5= Peak flow factor for design of pipe from tap-off point to individual building under gravity flow c) peak factors to be determined based on the type of distribution d) average flow is the total daily demand requirement divided by 24 hours Looping and branching system was considered to provide in design criteria Calculation for domestic system (Masjid) Design Calculation Normal Flow = 1 Peak Flow = 2.5 Calculation for hydrant system (for fire flow) Design Calculation Peak Flow Factor = 2.5 Min HL/KM = 0.00001 Max HL/KM = 2 Residual Head = 10 Calculation for building system (for branching system) Design Calculation Normal Flow = 1 Peak Flow = 2.5 1.4 Reference: MWA Design Guidelines for Water Supply Systems published by Water Supply by Malaysia Water Association Design Criteria and Standards for water supply system published Cawangan Bekalan Air, Jabatan Kerja Raya, Malaysia

Total Water Demand No. Bil (person) Bangunan Keperluan (gal/day) Kuantiti (gal) 1 5000 1 unit Masjid 3 tingkat 11 gpd/per 55,000 2 30 Rumah Kakitangan (A) (4 unit) 330/each 1,320 3 1000 Dewan Serbaguna 5,500 gpd/each 5,500 4 200 Taska (4 bilik) 7 gpd/ student 1,400 5 30 Rumah Kakitangan (B) (6 unit) 330/each 1,980 Jumlah 65,200 gal/day Domestic System (LOOP) 1 Total Water Demands : 65,200 gallon Total Q in L/S : ( 65,200 x 4.546 ) / ( 24 x 60 x 60 ) : 3.43 lit/sec 2 Normal Flow : 1.0 : 3.43 lit/sec x 1.0 : 3.43 lit/sec 3 Peak Flow : 2.5 : 3.43 lit/sec x 2.5 : 8.58 lit/sec Using Hazen-William Formula Roughness Coefficient, C = 100 (DI) Roughness Coefficient, C = 130 (HDPE) Adopt Diameter of Pipes, D = 150mm dia Breakdown (From M & E) 1 Water Tank A : 55,000 gallon ( masjid) α in L/S : ( 55,000 x 4.546 ) / ( 24 x 60 x 60 ) : 2.90 lit/sec 2 Water Tank B : 3,300 gallon ( rumah kakitangan (A) + (B)) : (3,300 x 4.546 ) / ( 24 x 60 60 ) : 0.174 lit / sec Level From Ground MASJID : 47.50 m + ( 14.00 m ) : 61.50 m RUMAH KAKITANGAN : 47.50 m + ( 14.00 m ) : 61.50 m 14.00 m = High from ground to building ( Water Tank Location ) 2m ( water tank + slab) 12m (height of masjid)

` For Fire Flow Total Fire Flow for Hydrant Fully Open Total in α L/S : ( 300 gallon x 4.546 ) lit / ( 60)min : 22.83 lit / sec Peak Flow : 2.5 : 22.83 x 2.5 : 57.075 lit / sec Using Hazen-William Formula Roughness Coefficient, C = 130 Adopt Diameter of Pipes, D = 150mm dia (HDPE 12.5)

RUMAH KAKITANGAN (A) + (B) (BRANCING SYSTEM) Total Demands : 3,300 gallon (assumption) : ( 3,300 x 4.546 ) / ( 24 x 60 x 60 ) : 0.174 lit / sec Using Hazen-William Formula Roughness Coefficient, C = 130 Adopt Diameter of Pipes, D = 150mm dia (HDPE 12.5) All the system analysis by computer

CALCULATION FOR DOMESTIC SYSTEM

Masjid Ar-Rahimah (Domestic) MT103 : PIPE NETWORK ANALYSIS VERSION : 1.0 (JUNE'85) Job title : WATER RETICULATION ANALYSIS FOR PEAK FLOW Number of nodes... 19 Number of pipes... 19 Minimum flow correction....1 litres/sec Node data NODE NO. DRAW OFF HYDRAULIC HEAD REDUCED LEVEL RESIDUAL HEAD litres/sec m m m 1-8.6 80.000 C 61.0 19.000 2 0.0 79.963 62.0 17.963 3 0.0 79.948 62.0 17.948 4 0.0 79.948 62.0 17.948 5 0.2 79.948 62.0 17.948 6 0.0 79.934 62.0 17.934 7 0.0 79.913 62.0 17.913 8 1.8 79.914 62.0 17.914 9 0.0 79.913 62.0 17.913 10 0.0 79.911 62.0 17.911 11 0.0 79.909 62.0 17.909 12 1.8 79.908 62.0 17.908 13 0.9 79.908 62.0 17.908 14 0.0 79.907 62.0 17.907 15 1.8 79.907 62.0 17.907 16 0.0 79.914 62.0 17.914 17 0.0 79.914 62.0 17.914 18 1.8 79.913 62.0 17.913 19 0.3 79.947 62.0 17.947 Pipe data NA NB DIA LGTH C R FLOW VELOCITY HD.LOSS HY.GRAD. mm m litres/sec m/sec m m/1000m 1 2 200. 63. 100. 0.001 7. 0.23 0.037 0.590 2 3 150. 10. 130. 0.000 7. 0.41 0.015 1.501 3 4 150. 18. 130. 0.001 0. 0.01 0.000 0.002 4 5 150. 22. 130. 0.001 0. 0.01 0.000 0.000 4 19 150. 29. 130. 0.001 0. 0.01 0.000 0.003 3 6 150. 9. 130. 0.000 7. 0.40 0.013 1.445 6 7 150. 50. 130. 0.002 4. 0.21 0.021 0.428 7 8 150. 3. 130. 0.000 2. 0.10 0.000 0.102 7 9 150. 6. 130. 0.000 2. 0.12 0.001 0.148 9 10 150. 7. 130. 0.000 2. 0.12 0.001 0.158 10 11 150. 19. 130. 0.001 2. 0.13 0.003 0.170 11 12 150. 2. 130. 0.000 2. 0.10 0.000 0.105 11 13 150. 14. 130. 0.001 1. 0.03 0.000 0.015 13 14 150. 16. 130. 0.001-0. -0.01-0.000-0.003 14 15 150. 17. 130. 0.001-0. -0.01-0.000-0.001 15 16 150. 47. 130. 0.002-2. -0.11-0.006-0.126 16 17 150. 6. 130. 0.000-2. -0.11-0.001-0.124 17 18 150. 11. 130. 0.000 2. 0.10 0.001 0.104 17 6 150. 54. 130. 0.002-4. -0.20-0.021-0.392 Page 1

CALCULATION FOR HYDRANT SYSTEM (FIRE FLOW)

Hydrant (H1) MT103 : PIPE NETWORK ANALYSIS VERSION : 1.0 (JUNE'85) Job title : WATER RETICULATION ANALYSIS FOR PEAK FLOW Number of nodes... 4 Number of pipes... 3 Minimum flow correction....1 litres/sec Node data NODE NO. DRAW OFF HYDRAULIC HEAD REDUCED LEVEL RESIDUAL HEAD litres/sec m m m 1-22.8 80.000 C 57.0 23.000 2 0.0 79.742 58.0 21.742 3 0.0 79.546 58.0 21.546 4 22.8 79.436 58.0 21.436 Pipe data NA NB DIA LGTH C R FLOW VELOCITY HD.LOSS HY.GRAD. mm m litres/sec m/sec m m/1000m 1 2 200. 63. 110. 0.001 23. 0.72 0.258 4.099 2 3 150. 16. 130. 0.001 23. 1.28 0.195 12.217 3 4 150. 9. 130. 0.000 23. 1.29 0.111 12.294 NUMBER OF REITERATIONS = 27 **End of program execution** --- NUMBER OF REITERATIONS = 27 Page 1

Hydrant (H2) MT103 : PIPE NETWORK ANALYSIS VERSION : 1.0 (JUNE'85) Job title : WATER RETICULATION ANALYSIS FOR PEAK FLOW Number of nodes... 6 Number of pipes... 5 Minimum flow correction....1 litres/sec Node data NODE NO. DRAW OFF HYDRAULIC HEAD REDUCED LEVEL RESIDUAL HEAD litres/sec m m m 1-22.8 80.000 C 57.0 23.000 2 0.0 79.732 58.0 21.732 3 0.0 79.530 58.0 21.530 4 0.0 79.416 58.0 21.416 5 0.0 79.041 58.0 21.041 6 22.8 78.356 58.0 20.356 Pipe data NA NB DIA LGTH C R FLOW VELOCITY HD.LOSS HY.GRAD. mm m litres/sec m/sec m m/1000m 1 2 200. 63. 110. 0.001 23. 0.74 0.268 4.250 2 3 150. 16. 130. 0.001 23. 1.31 0.203 12.665 3 4 150. 9. 130. 0.000 23. 1.30 0.113 12.595 4 5 150. 30. 130. 0.001 23. 1.30 0.376 12.523 5 6 150. 55. 130. 0.002 23. 1.29 0.684 12.443 NUMBER OF REITERATIONS = 65 **End of program execution** --- NUMBER OF REITERATIONS = 65 **End of program execution** Page 1

Hydrant (H3) MT103 : PIPE NETWORK ANALYSIS VERSION : 1.0 (JUNE'85) Job title : WATER RETICULATION ANALYSIS FOR PEAK FLOW Number of nodes... 5 Number of pipes... 4 Minimum flow correction....1 litres/sec Node data NODE NO. DRAW OFF HYDRAULIC HEAD REDUCED LEVEL RESIDUAL HEAD litres/sec m m m 1-22.8 80.000 C 57.0 23.000 2 0.0 79.733 58.0 21.733 3 0.0 79.532 58.0 21.532 4 0.0 79.420 58.0 21.420 5 22.8 79.046 58.0 21.046 Pipe data NA NB DIA LGTH C R FLOW VELOCITY HD.LOSS HY.GRAD. mm m litres/sec m/sec m m/1000m 1 2 200. 63. 110. 0.001 23. 0.73 0.267 4.233 2 3 150. 16. 130. 0.001 23. 1.30 0.201 12.553 3 4 150. 9. 130. 0.000 23. 1.30 0.112 12.469 4 5 150. 30. 130. 0.001 23. 1.30 0.374 12.469 NUMBER OF REITERATIONS = 60 **End of program execution** --- Page 1