1 SERIES FLOW FAN POWERED TERMINAL UNIT
2 The FDC, series flow, fan powered terminal unit, is designed to supply air volume to the occupied zone in response to a control signal. Features such as advanced sensor technology, a wide range of product sizes and air flows, low sound levels, increased hot water coil selections, and innovative options establish Price as an industry leader for terminal units. Motor Vibration Isolation Full-Sized Top and Bottom Access Panels 20 GA casing 2 For more information visit v100
3 FIELD REVERSIBILITY With a centered inlet, the discharge is not the direct center of the unit in regards to height, it is centered in regards to the width, with full-sized access panels on the top and bottom, this unit can be reoriented between left-hand and right-hand configurations on the job site. This also includes units equipped with hot water reheat and flippable electric reheat. COMPACT DESIGN Ideal for installations with limited space, the small footprint allows for easier installation and less required clearance. ECM PROGRAM OPTIONS The FDC provides added flexibility by allowing the user to select an ECM program to best suit the application. + + High Turndown Flow This program enables lower minimum fan speeds and in most cases gives a 10:1 turndown ratio. + + Pressure Independent Flow This program ensures that the motor maintains the fan flow within 5% of the flow setpoint across varying static pressures. TYPICAL APPLICATIONS The FDC is commonly used to provide constant airflow to exterior zones where the heating and cooling loads vary. They are also used in buildings to provide heat during periods of non-occupancy where it is desirable to leave the central air handling system off. For most typical operating sequences, the fan will deliver the maximum cooling air volume. Price offers a variety of alternative sequences that will allow the fan volume to vary based on zone requirements and control signal input. STANDARD DESIGN GA. casing for sound reduction + + Full size top and bottom access doors + + Field reversible handing, including electric coil + + Motor vibration isolation OPTIONAL FEATURES + + Electric and hot water reheat + + ECM Motor + + Inlet attenuator sections + + Multiple liner options Full-Sized Top and Bottom Access Panels v100 For more information visit 3
4 QUIET OPERATION Genesis Inlet Attenuator The FDC is available with return inlet attenuators for a cost-effective solution for sound sensitive applications. Inlet attenuators reduce radiated sound, and are ideal for installations directly above sound sensitive spaces. For ease of installation, inlet attenuators are shipped installed on the assembly. Discharge Attenuator For applications where the FDC is discharging into a sound sensitive space, such as a meeting room or an office, a discharge attenuator is available to help reduce discharge sound. Both inlet and discharge attenuators are conveniently available with any of the standard Price liner options. Discharge Silencer For unparalleled sound attenuation, Price offers an integrated silencer specifically designed for the FDC. This close coupled silencer is optimized to reduce self-generated noise, minimize pressure drop, and maximize acoustic attenuation resulting in the quietest series fan powered terminal unit. CONTROLS Price offers a complete line of controls to best suit any application. For exceptional user comfort, the Price Intelligent Controller (PIC) universal DDC control package is available factory installed on all FDC units. 4 For more information visit v100
5 HOT WATER REHEAT Price water coils are constructed from high quality materials and are AHRI410 certified. Designed to optimize heat transfer, water coils are available in standard and high capacity configurations to meet the requirements of every project. For ease of maintenance, optional access doors are available for upstream or downstream installation, with a variety of fastening choices. VALVE PACKAGES Hot water coils are available with a factory leaktested valve package for simplicity and ease of installation. Each valve package is available with the following options: + + Factory installed or shipped loose as assemblies for field installation way or 3-way valves + + Valve package enclosure ELECTRIC REHEAT Price electric coils are factory mounted, ETL listed to meet electrical safety standards, and comply with CSA236/UL1995. Field reversible fan powered electric heaters are a side-mounted, slide-in style, specifically designed to mount on the terminal discharge, allowing for easy field maintenance. Thermal safety switches and fan interlocked heating elements are supplied to ensure safe operation. ACCESSORIES Additional accessories are offered to meet specific job requirements. Details on these accessories are available in the Terminal Units Accessories catalog. v100 For more information visit 5
6 DIMENSIONAL DATA Unit Size Inlet Size Height (H) , 8, 10, 12 Basic Box Width (W) With Inlet Attenuator IAS Basic Box With Inlet Attenuator IAS Length (L) With Electric Coil EC With Water Coil WC 4, /2 in. 53 in. 47 1/2 in. 15 1/4 in. 20 in. 29 in. 6, 8, 10, /2 in. 51 in. 45 1/2 in. 30 8, 10, 12, 14, /2 in. 26 in. 41 in , 12, 14, in. 45 1/2 in. 56 in. 50 1/2 in , 14, in. 47 in. 48 1/2 in. 59 in. 53 1/2 in. 20 1/8 in. 48 1/2 in , in. 52 in. 82 3/8 in. 94 1/2 in. 65 in. FDC Basic Box FDC 60 Basic Box 6 For more information visit v100
7 FDC with ECM - Fan Performance Curves Unit Size Static Pressure, Inches w.g High-Turndown Program Min. Flow Pressure Independent Program Min. Flow Pressure Independent Flow Range 0.10 Unit Size Airflow Rate, cfm Static Pressure, Inches w.g High-Turndown Program Min. Flow Pressure Independent Program Min. Flow Pressure Independent Flow Range Airflow Rate, cfm No Coil 1 Row 2 Row v100 For more information visit 7
8 FDC with ECM - Fan Performance Curves Unit Size Static Pressure, Inches w.g High-Turndown Program Min. Flow Pressure Independent Program Min. Flow Pressure Independent Flow Range Unit Size Airflow Rate, cfm 0.50 Static Pressure, Inches w.g High-Turndown Program Min. Flow Pressure Independent Program Min. Flow Pressure Independent Flow Range Airflow Rate, cfm No Coil 1 Row 2 Row 8 For more information visit v100
9 FDC with ECM - Fan Performance Curves Unit Size Static Pressure, Inches w.g High-Turndown Program Min. Flow Pressure Independent Program Min. Flow Pressure Independent Flow Range 0.10 Unit Size Airflow Rate, cfm Static Pressure, Inches w.g High-Turndown Program Min. Flow Pressure Independent Program Min. Flow Pressure Independent Flow Range Airflow Rate, cfm No Coil 1 Row 2 Row v100 For more information visit 9
10 FDC with PSC - Fan Performance Curves Unit Size Static Pressure, Inches w.g Airflow Rate, cfm Unit Size Static Pressure, Inches w.g Airflow Rate, cfm No Coil 1 Row 2 Row Min 10 For more information visit v100
11 FDC with PSC - Fan Performance Curves Unit Size Static Pressure, Inches w.g Airflow Rate, cfm Unit Size Static Pressure, Inches w.g Airflow Rate, cfm No Coil 1 Row 2 Row Min v100 For more information visit 11
12 FDC with PSC - Fan Performance Curves Unit Size Static Pressure, Inches w.g Unit Size Airflow Rate, cfm Static Pressure, Inches w.g Airflow Rate, cfm No Coil 1 Row 2 Row Min 12 For more information visit v100
13 FDC - ECM Capacities Unit Size Inlet Size Primary Airflow Fan Airflow Full Load Amps Motor HP Minimum Maximum Minimum Maximum 115V 208V 240V 277V * / * * * / * * * / * * * * / * * * * * /4 (2) FDC - PSC Capacities Unit Size Inlet Size Primary Airflow Fan Airflow Full Load Amps Motor HP Minimum Maximum Minimum Maximum 115V 208V 240V 277V * / * * * / * * * / * * * * / * * x * * /4 (2) *Maximum primary airflow is limited by the maximum fan airflow. Note: Maximum fan airflow values in the tables are for the base assembly (no coil, no filter) with a downstream static pressure of 0.1 in. w.g. v100 For more information visit 13
14 FDC Electric Coil Max kw - Single Point Connection Size 1 Phase Voltage 3 Phase Voltage FDC Electric Coil Max kw - Dual Point Connection Size 1 Phase Voltage 3 Phase Voltage SELECTION PARAMETERS Supply Voltage/Phase Selection Common Supply Voltages Electric coils for Fan power Terminal units can be ordered for a variety Voltage supplies. When possible, a single point connection is provided for the heater and fan motor. Table 1, below, indicates compatible heater/fan motor voltages. Heater Volts/Phase Fan Motor Volts/Phase 115V/1PH 115V/1PH 208V/1PH 208V/1PH 240V/1PH 240V/1PH Single Point Connection 277V/1PH 277V/1PH 480V/1PH *3 wire 277V/1PH 208V/3PH 208V/1PH 480V/3PH *4 wire 115V/1PH Dual Point Connection 600V/3PH 115V/1PH * When 480 V/3PH or 480/1PH power is specified a neutral line must be run in order to provide a one point connection. The neutral and one of the hot 480 V legs in used to supply 277 V to the fan motor. See illustration. Notes: 1. ETL certified assemblies. 2. Minimum kw: Single Phase = 0.5 kw per stage. Three Phase = 1.5 kw. 3. The recommended limit of 48 Amps may be exceeded. This requires supplemental fusing to meet NEC code requirements. Contact your local Price representative for further details 4. Maximum kw limitations is the lesser of a) coil selection chart, orw b) minimum air flow requirements of 70 cfm/kw. 14 For more information visit v100
15 FDC - AHRI Certification Rating Points Discharge Sound Power Levels Unit Size Fan 2 (cfm) Input 3 (W) Min. Δ Ps Inlet 4 (in. w.g.) Discharge Sound Power Level (db) Fan Only Radiated Sound Power Levels Radiated Sound Power Level (db) Unit Primary 1 Fan 2 Input Min. Fan Only in. Inlet Static w.g. 3 Size cfm cfm (W) Δ Ps Inlet 4 (in. w.g.) AHRI Certification Notes: 1. Primary cfm is the standard rated air volume for the inlet. 2. Fan cfm is the maximum rated fan volume at 0.25" w.g. downstream static pressure. 3. Input watts is the maximum electrical power input at the maximum rated fan volume. 4. Minimum operating pressure inlet is the minimum operating pressure requirement of the primary air valve at the rated primary cfm. 5. Fan only sound power levels are at the maximum rated fan volume. 6. Sound power levels include duct end corrections per AHRI Standard Please refer to the Engineering Guide for more details. v100 For more information visit 15
16 FDC - Radiated Sound Power Levels Unit Size Inlet Size Inch Sound Power Levels, Lw, db re Watts Primary Fan Primary Air Fan Only Airflow Airflow 0.5 in. w.g. 1.0 in w.g. 1.5 in w.g. L/s cfm L/s cfm Performance Notes: 1. Test data obtained in accordance with AHRI Standard and ASHRAE Standard Data does not include corrections for Room Absorption, duct attenuation, or ceiling transmission loss. 3. Sound power levels include duct end corrections per AHRI Standard Please refer to the Engineering Guide for more details. 4. Fan external static pressure is 0.25 in. w.g. in all cases. 5. AHRI certified data is highlighted in blue. All other data are application ratings. 16 For more information visit v100
17 FDC - Discharge Sound Power Levels Unit Size Inlet Size Inch Sound Power Levels, Lw, db re Watts Primary Fan Primary Air Fan Only Airflow Airflow 0.75 in w.g. 1.0 in w.g. 1.5 in w.g. L/s cfm L/s cfm Performance Notes: 1. Test data obtained in accordance with AHRI Standard and ASHRAE Standard v100 For more information visit 2. Sound power levels include duct end corrections per AHRI Standard Please refer to the Engineering Guide for more details. 3. Fan external static pressure is 0.25 in. w.g. in all cases. 4. AHRI certified data is highlighted in blue. All other data are application ratings. 17
18 FDC with Attenuator - ARI Certification Rating Points Discharge Sound Power Level Unit Size Fan 2 cfm Input 3 (W) Min. Δ Ps Inlet 4 (in. w.g.) Discharge Sound Power Level (db) Fan Only Radiated Sound Power Level Radiated Sound Power Level (db) Unit Size Primary1 (cfm) Fan 2 cfm Input 3 (W) Min. Fan Only in Inlet Static w.g. Δ Ps Inlet 4 (in. w.g.) AHRI Certification Notes: 1. Primary CFM is the standard rated air volume for the inlet. 2. Fan CFM is the maximum rated fan volume at 0.25 w.g. downstream static pressure. 3. Input watts is the maximum electrical power input at the maximum rated fan volume. 4. Minimum operating pressure inlet is the minimum operating pressure requirement of the primary air valve at the rated primary CFM. 5. Fan only sound power levels are at the maximum rated fan volume. 6. Sound power levels include duct end corrections per AHRI Standard Please refer to the Engineering Guide for more details. 18 For more information visit v100
19 FDC with Attenuator - Radiated Sound Power Levels Unit Size Inlet Size Inch Sound Power Levels, Lw, db re Watts Primary Fan Primary Air Fan Only Airflow Airflow 0.5 in w.g. 1.0 in w.g. 1.5 in w.g. L/s cfm L/s cfm Performance Notes: 1. Test data obtained in accordance with AHRI Standard and ASHRAE Standard Data does not include corrections for Room Absorption, duct attenuation, or ceiling transmission loss. v100 For more information visit 3. Sound power levels include duct end corrections per AHRI Standard Please refer to the Engineering Guide for more details. 4. Fan external static pressure is 0.25 in. w.g. in all cases. 5. AHRI certified data is highlighted in blue. All other data are application ratings. 19
20 FDC with Attenuator - Discharge Sound Power Levels Unit Size Inlet Size Inch Sound Power Levels, Lw, db re Watts Primary Fan Primary Air Fan Only Airflow Airflow 0.75 in w.g. 1.0 in w.g. 1.5 in w.g. L/s cfm L/s cfm Performance Notes: 1. Test data obtained in accordance with AHRI Standard and ASHRAE Standard Data does not include corrections for Room Absorption, duct attenuation, or ceiling transmission loss. 3. Sound power levels include duct end corrections per AHRI Standard Please refer to the Engineering Guide for more details. 4. Fan external static pressure is 0.25 in. w.g. in all cases. 5. AHRI certified data is highlighted in blue. All other data are application ratings. 20 For more information visit v100
21 FDC - 1 and 2 Row Hot Water Coil Data Size 10 Standard Capacity Airflow Rate (cfm) Rows Coil gpm HD Loss Row Multi Circuit Through the Coil, Ps Row Multi Circuit Through the Coil, Ps Size 10 High Capacity Airflow Rate (cfm) Rows Coil gpm HD Loss Row Multi Circuit Through the Coil, Ps Row Multi Circuit Through the Coil, Ps Size 20 Standard Capacity Airflow Rate (cfm) Rows Coil gpm HD Loss Row Multi Circuit Through the Coil, Ps Row Multi Circuit Through the Coil, Ps For performance notes, see end of section. v100 For more information visit 21
22 FDC - 1 and 2 Row Hot Water Coil Data Size 20 High Capacity Airflow Rate (cfm) Rows Coil gpm HD Loss Row Multi Circuit Through the Coil, Ps Row Multi Circuit Through the Coil, Ps Size 30 Standard Capacity Airflow Rate (cfm) Rows Coil gpm HD Loss Row Multi Circuit Through the Coil, Ps Row Multi Circuit Through the Coil, Ps Size 30 High Capacity Airflow Rate (cfm) Rows Coil gpm HD Loss Row Multi Circuit Through the Coil, Ps Row Multi Circuit Through the Coil, Ps For performance notes, see end of section. 22 For more information visit v100
23 FDC - 1 and 2 Row Hot Water Coil Data Size 40 Standard Capacity Rows Coil gpm HD Loss Airflow Rate (cfm) Row Multi Circuit Through the Coil, Ps Row Multi Circuit Through the Coil, Ps Size 40 High Capacity Rows Coil gpm HD Loss Airflow Rate (cfm) Row Multi Circuit Through the Coil, Ps Row Multi Circuit Through the Coil, Ps Size 50 Standard Capacity Rows Coil gpm HD Loss Airflow Rate (cfm) Row Multi Circuit Through the Coil, Ps Row Multi Circuit Through the Coil, Ps For performance notes, see end of section. v100 For more information visit 23
24 FDC - 1 and 2 Row Hot Water Coil Data Size 50 High Capacity Rows Coil gpm HD Loss Airflow Rate (cfm) Row Multi Circuit Through the Coil, Ps Row Multi Circuit Through the Coil, Ps Size 60 Standard Capacity Rows Coil gpm HD Loss Airflow Rate (cfm) Row Multi Circuit Through the Coil, Ps Row Multi Circuit Through the Coil, Ps Size 60 High Capacity Rows Coil gpm HD Loss Airflow Rate (cfm) Row Multi Circuit Through the Coil, Ps Row Multi Circuit Through the Coil, Ps Performance Notes: 1. Tabulated values are in MBH (thousands of Btu per hour). 2. Tables are based on (57 F entering water temperature and 75 F entering air temperature). Entering water temperature must be above plenum dew point to prevent condensation on the coil (typically F). 3. Minimum air and water flow values are based on ASHRAE recommendations for coil selections. For selections below these tabulated air or water values, please consult your local Price representative. 4. HD (Head) loss is in ft. of water. 5. Through the Coil Ps, is the pressure drop in in. of water across the coil. 6. Air temperature rise = ATR ATR ( F) = 927 x MBH/cfm 7. Water temperature drop = WTD WTD ( F) = 2.04 x MBH/gpm 8. Values in tables are listed for 0 ft. of altitude and no glycol in the system. 9. For information outside the ranges used in the table, consult the current Price software or your Price representative for accurate coil information. 10. Cooling coils used in this unit have performance rated and certified in accordance with the current edition of AHRI Standard Connections: Single Circuit 1 /2 in. OD male solder Multi Circuit 7 /8 in. OD male solder. 24 For more information visit v100
25 Product Improvement is a continuing endeavour at Price. Therefore, specifications are subject to change without notice. Consult your Price Sales Representative for current specifications or more detailed information. Not all products may be available in all geographic areas. All goods described in this document are warranted as described in the Limited Warranty shown at priceindustries.com. The complete Price product catalog can be viewed online at priceindustries.com. Price is a registered trademark of Price Industries Limited Printed in Canada. v100
Engineer Reference 1 / / A 35 7/16 X 7 7/8 X 23 5/8 31 1/8 X 21 7/8 X 11 1/4 14 T T 75 R410A oz/ft over 50' 265 / 318 / 388
Slim Duct, single zone split system SUBMITTAL EH035CAV / UH035CAV Specifications Nominal Capacity Cooling/Heating (Btu/h) 12,000 / 13,600 Cooling (Btu/h) 3,300-14,300 Capacity Range Heating (Btu/h) 3,100-18,000
Διαβάστε περισσότεραHeat exchanger. Type WT. For the reheating of airflows in rectangular ducting PD WT 1. 03/2017 DE/en
X X testregistrierung Heat exchanger Type For the reheating of airflows in rectangular ducting Rectangular hot water heat exchanger for the reheating of airflows, suitable for VAV terminal units Type TVR,
Διαβάστε περισσότεραUDZ Swirl diffuser. Product facts. Quick-selection. Swirl diffuser UDZ. Product code example:
UDZ Swirl diffuser Swirl diffuser UDZ, which is intended for installation in a ventilation duct, can be used in premises with a large volume, for example factory premises, storage areas, superstores, halls,
Διαβάστε περισσότεραS /5000 BTU/Hr. 1000/1500 Watt
763.576.32 SPEC-168 D763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners SPECTRACOOL SLIM FIT INDOOR S6 1/17 BTU/Hr. 3/5 Watt S1 34/5 BTU/Hr. 1/15 Watt
Διαβάστε περισσότερα4 Way Reversing Valve
STANDARD 4 Way Reversing Valve SHF series four-way reversing valves are applicable for heat pump systems such as central, unitary and room air conditioners to realize switching between cooling mode and
Διαβάστε περισσότεραCOPELAND SCROLL AIR COOLED CONDENSING UNITS
R404A Refrigerant Scroll R507A Refrigerant R134A Refrigerant STANDARD UNIT WITH: Copeland ZB Scroll Compressors for medium temp applications on R404A/R507A/R134A Copeland ZB & ZF Scroll Compressors for
Διαβάστε περισσότεραSmaller. 6.3 to 100 After 1 minute's application of rated voltage at 20 C, leakage current is. not more than 0.03CV or 4 (µa), whichever is greater.
Low Impedance, For Switching Power Supplies Low impedance and high reliability withstanding 5000 hours load life at +05 C (3000 / 2000 hours for smaller case sizes as specified below). Capacitance ranges
Διαβάστε περισσότεραMS20 High-Efficiency Mini-Split System
MS20 High-Efficiency Mini-Split System Up to 20 SEER Performance Product Features R-410A chlorine-free refrigerant High-efficiency performance up to 20 SEER DC Inverter technology compressor Indoor antibacterial
Διαβάστε περισσότεραPrecision Metal Film Fixed Resistor Axial Leaded
Features EIA standard colour-coding Non-Flame type available Low noise and voltage coefficient Low temperature coefficient range Wide precision range in small package Too low or too high ohmic value can
Διαβάστε περισσότεραElectrical Specifications at T AMB =25 C DC VOLTS (V) MAXIMUM POWER (dbm) DYNAMIC RANGE IP3 (dbm) (db) Output (1 db Comp.) at 2 f U. Typ.
Surface Mount Monolithic Amplifiers High Directivity, 50Ω, 0.5 to 5.9 GHz Features 3V & 5V operation micro-miniature size.1"x.1" no external biasing circuit required internal DC blocking at RF input &
Διαβάστε περισσότεραThin Film Chip Resistors
FEATURES PRECISE TOLERANCE AND TEMPERATURE COEFFICIENT EIA STANDARD CASE SIZES (0201 ~ 2512) LOW NOISE, THIN FILM (NiCr) CONSTRUCTION REFLOW SOLDERABLE (Pb FREE TERMINATION FINISH) Type Size EIA PowerRating
Διαβάστε περισσότεραMARKET INTRODUCTION System integration
MARKET INTRODUCTION System integration Air to Water Split System Inverter Driven Nomιnal Capacities : 5-6,5-9 - 11,5 kwth Max LWT= 60 C & Min OAT = -15 C COP>= 4.1 Air to Water Monoblock Inverter Driven
Διαβάστε περισσότεραZLW Series. Single-stage Monoblock Centrifugal Pump ZL PUMP GROUP.,LTD
ZLW Series Single-stage Monoblock Centrifugal Pump ZL PUMP GROUP.,LTD 1 Application Apply as the transportation of liquids in the fields of air condition, heating, sanitary water, water treatment cooling,
Διαβάστε περισσότεραNMBTC.COM /
Common Common Vibration Test:... Conforms to JIS C 60068-2-6, Amplitude: 1.5mm, Frequency 10 to 55 Hz, 1 hour in each of the X, Y and Z directions. Shock Test:...Conforms to JIS C 60068-2-27, Acceleration
Διαβάστε περισσότεραACTORS IEC CONT Ex9C
IEC CONTCTORS Ex9C Ex9C Product Overview Features C-3 contactor ratings from 630 and C-1 contactor ratings to 800 voltages from 24~600, 50/60 Hz Full Non-Reversing (FVNR) and Full Reversing (FVR) 5 k @
Διαβάστε περισσότεραMS15 High-Efficiency Mini-Split System
MS15 High-Efficiency Mini-Split System Up to 15 SEER Performance Product Features R-410A chlorine-free refrigerant High-efficiency performance: up to 15 SEER DC Inverter technology compressor Auto-restart
Διαβάστε περισσότερα4 Way Reversing Valve
STANDARD 4 Way Reversing Valve SHF series four-way reversing valves are applicable for heat pump systems such as central, unitary and room air conditioners to realize switching between cooling mode and
Διαβάστε περισσότεραMetal thin film chip resistor networks
Metal thin film chip resistor networks AEC-Q200 Compliant Features Relative resistance and relative TCR definable among multiple resistors within package. Relative resistance : ±%, relative TCR: ±1ppm/
Διαβάστε περισσότεραNPI Unshielded Power Inductors
FEATURES NON-SHIELDED MAGNETIC CIRCUIT DESIGN SMALL SIZE WITH CURRENT RATINGS TO 16.5 AMPS SURFACE MOUNTABLE CONSTRUCTION TAKES UP LESS PCB REAL ESTATE AND SAVES MORE POWER TAPED AND REELED FOR AUTOMATIC
Διαβάστε περισσότεραSwirl diffusers, Variable swirl diffusers Swirl diffusers
, Variable swirl diffusers Swirl diffuser OD-9 Square or round front mask Square or radial deflector arrangement Plastic deflectors Possible volume control damper in spigot Foam sealing on the flange St
Διαβάστε περισσότεραSurface Mount Aluminum Electrolytic Capacitors
FEATURES CYLINDRICAL V-CHIP CONSTRUCTION LOW COST, GENERAL PURPOSE, 2000 HOURS AT 85 O C NEW EXPANDED CV RANGE (up to 6800µF) ANTI-SOLVENT (2 MINUTES) DESIGNED FOR AUTOMATIC MOUNTING AND REFLOW SOLDERING
Διαβάστε περισσότεραFinish: Anticorrosive finish in polyester. Number of motor poles 4=1400 r/min. 50 Hz 6=900 r/min. 50 Hz 8=750 r/min. 50 Hz
HEP HEPT HEP: Wall-mounted axial fans, with IP65 motor HEPT: Long-cased axial fans, with IP65 motor Wall-mounted axial (HEP) and long-cased (HEPT) fans, with fibreglass-reinforced plastic impeller. Fan:
Διαβάστε περισσότεραModel: MTZ22. Data. Cylinder count: 1 Displacement [m³/h]: 6,63 Cylinder capacity [cm³]: 38,1 RPM [min -1 ]: 2900 Weight [kg]: 21 Oil charge [dm³]: 1
Technical data Data Cylinder count: 1 Displacement [m³/h]: 6,63 Cylinder capacity [cm³]: 38,1 RPM [min -1 ]: 2900 Weight [kg]: 21 Oil charge [dm³]: 1 Oil type: 160PZ Crankcase heater type: PTC 35 W Maximum
Διαβάστε περισσότεραVentilated Distribution Transformers
General Purpose Energy efficient dry-type transformers 600 Volt Class, isolation type, single and three phase, 1 through 00. Indoor and outdoor models available. Accessories and Optional Styles trostatic
Διαβάστε περισσότερα3 V, 1500 MHz Si MMIC WIDEBAND AMPLIFIER
V, MHz Si MMIC WIDEBAND AMPLIFIER UPC7T FEATURES WIDE FREQUENCY RESPONSE: MHz LOW VOLTAGE OPERATION: V NOMINAL (. MIN) LOW POWER CONSUMPTION:. mw TYP SUPER SMALL PACKAGE TAPE AND REEL PACKAGING OPTION
Διαβάστε περισσότεραRAC. Technical Data Book. RAC(Quantum) for North America (R410A, 60Hz, HP) Model : AR09/12/18/24KSFPDWQNCV AR09/12/18/24KSFPDWQXCV
RAC Technical Data Book RAC(Quantum) for North America (R410A, 60Hz, HP) Model : AR09/12/18/24KSFPDWQNCV AR09/12/18/24KSFPDWQXCV History Version Modification Date Remark Ver 1.0 Release RAC (Quantum) TDB
Διαβάστε περισσότεραCSR series. Thick Film Chip Resistor Current Sensing Type FEATURE PART NUMBERING SYSTEM ELECTRICAL CHARACTERISTICS
FEATURE Operating Temperature: -55 ~ +155 C 3 Watts power rating in 1 Watt size, 1225 package High purity alumina substrate for high power dissipation Long side terminations with higher power rating PART
Διαβάστε περισσότερα3 V, 900 MHz LOW NOISE SI MMIC AMPLIFIER
V, 9 MHz LOW NOISE SI MMIC AMPLIFIER UPC78T FEATURES.8 db NOISE FIGURE LOW VOLTAGE - LOW CURRENT: ma at V LOW POWER CONSUMPTION: 8 mw TYP SUPER SMALL PACKAGE TAPE AND REEL PACKAGING OPTION AVAILABLE DESCRIPTION
Διαβάστε περισσότεραAluminum Electrolytic Capacitors (Large Can Type)
Aluminum Electrolytic Capacitors (Large Can Type) Snap-In, 85 C TS-U ECE-S (U) Series: TS-U Features General purpose Wide CV value range (33 ~ 47,000 µf/16 4V) Various case sizes Top vent construction
Διαβάστε περισσότεραMetal Oxide Varistors (MOV) Data Sheet
Φ SERIES Metal Oxide Varistors (MOV) Data Sheet Features Wide operating voltage (V ma ) range from 8V to 0V Fast responding to transient over-voltage Large absorbing transient energy capability Low clamping
Διαβάστε περισσότεραAluminum Electrolytic Capacitors
Aluminum Electrolytic Capacitors Snap-In, Mini., 105 C, High Ripple APS TS-NH ECE-S (G) Series: TS-NH Features Long life: 105 C 2,000 hours; high ripple current handling ability Wide CV value range (47
Διαβάστε περισσότεραInstruction Execution Times
1 C Execution Times InThisAppendix... Introduction DL330 Execution Times DL330P Execution Times DL340 Execution Times C-2 Execution Times Introduction Data Registers This appendix contains several tables
Διαβάστε περισσότερα3 V, 900 MHz Si MMIC AMPLIFIER
V, 9 MHz Si MMIC AMPLIFIER UPC77T FEATURES LOW VOLTAGE - LOW CURRENT: ma at V LOW POWER CONSUMPTION: mw TYP SUPER SMALL PACKAGE TAPE AND REEL PACKAGING OPTION AVAILABLE DESCRIPTION The UPC77T is a Silicon
Διαβάστε περισσότεραMultilayer Ceramic Chip Capacitors
FEATURES X7R, X6S, X5R AND Y5V DIELECTRICS HIGH CAPACITANCE DENSITY ULTRA LOW ESR & ESL EXCELLENT MECHANICAL STRENGTH NICKEL BARRIER TERMINATIONS RoHS COMPLIANT SAC SOLDER COMPATIBLE* PART NUMBER SYSTEM
Διαβάστε περισσότερα2.5 GHz SILICON MMIC WIDE-BAND AMPLIFIER
. GHz SILICON MMIC WIDE-BAND AMPLIFIER UPC79T FEATURES WIDE FREQUENCY RESPONSE:. GHz 3 GAIN vs. FREQUENCY HIGH GAIN: 3 db (UPC79T) SATURATED OUTPUT POWER: +. dbm (UPC79T) INTERNAL CURRENT REGULATION MINIMIZES
Διαβάστε περισσότεραDimensional Data - All tolerances (± 0.01) inches. 5.33 x 6.60.21" x.26" (Typ. 2) 11.68 x 12.95.46" x.51" (Typ. 2)
0-700 Volts, 100 Amps Bussmann BH-0 Series Dimensional Data - All tolerances (± 0.25) mm (± 0.01) inches B 54.23 2.135" 71.42 2.812" Catalog Symbol: BH-0 Series Base: Light-weight, high temperature thermoplastic
Διαβάστε περισσότεραRSDW08 & RDDW08 series
/,, MODEL SELECTION TABLE INPUT ORDER NO. INPUT VOLTAGE (RANGE) NO LOAD INPUT CURRENT FULL LOAD VOLTAGE CURRENT EFFICIENCY (Typ.) CAPACITOR LOAD (MAX.) RSDW08F-03 344mA 3.3V 2000mA 80% 2000μF RSDW08F-05
Διαβάστε περισσότεραOperating Temperature Range ( C) ±1% (F) ± ~ 1M E-24 NRC /20 (0.05) W 25V 50V ±5% (J) Resistance Tolerance (Code)
FEATURES EIA STANDARD SIZING 0201(1/20), 0402(1/16), 0603(1/10), 0805(1/8), 1206(1/4), 1210(1/3), 2010(3/4) AND 2512(1) METAL GLAZED THICK FILM ON HIGH PURITY ALUMINA SUBSTRATE..(CERMET) PROVIDES UNIFORM
Διαβάστε περισσότερα2R2. 2 (L W H) [mm] Wire Wound SMD Power Inductor. Nominal Inductance Packing Tape & Reel. Design Code M ±20%
Wire Wound SMD Power Inductors WPN Series Operating temperature range : -40 ~+125 (Including self-heating) FEATURES Fe base metal material core provides large saturation current Metallization on ferrite
Διαβάστε περισσότεραHigh Performance Voltage Controlled Amplifiers Typical and Guaranteed Specifications 50 Ω System
High Performance Voltage Controlled Amplifiers Typical and Guaranteed Specifications 50 Ω System Typical and guaranteed specifications vary versus frequency; see detailed data sheets for specification
Διαβάστε περισσότεραRAC. Technical Data Book. RAC(Max Heat) for North America (R410A, 60Hz, HP) Model : AR09/12KSWSPWKNCV AR09/12KSWSPWKXCV
RAC Technical Data Book RAC(Max Heat) for North America (R410A, 60Hz, HP) Model : AR09/12KSWSPWKNCV AR09/12KSWSPWKXCV History Version Modification Date Remark Ver.1.0 Release RAC (Max Heat) TDB for North
Διαβάστε περισσότεραSPBW06 & DPBW06 series
/,, MODEL SELECTION TABLE INPUT ORDER NO. INPUT VOLTAGE (RANGE) NO LOAD INPUT CURRENT FULL LOAD VOLTAGE CURRENT EFFICIENCY (TYP.) CAPACITOR LOAD (MAX.) SPBW06F-03 310mA 3.3V 0 ~ 1500mA 81% 4700μF SPBW06F-05
Διαβάστε περισσότεραFirst Sensor Quad APD Data Sheet Part Description QA TO Order #
Responsivity (/W) First Sensor Quad PD Data Sheet Features Description pplication Pulsed 16 nm laser detection RoHS 211/65/EU Light source positioning Laser alignment ø mm total active area Segmented in
Διαβάστε περισσότεραBulletin 1489 UL489 Circuit Breakers
Bulletin 489 UL489 Circuit Breakers Tech Data 489-A Standard AC Circuit Breaker 489-D DC Circuit Breaker 489-A, AC Circuit Breakers 489-D, DC Circuit Breakers Bulletin 489-A Industrial Circuit Breaker
Διαβάστε περισσότεραMultilayer Ceramic Chip Capacitors
FEATURES X7R, X6S, X5R AND Y5V DIELECTRICS HIGH CAPACITANCE DENSITY ULTRA LOW ESR & ESL EXCELLENT MECHANICAL STRENGTH NICKEL BARRIER TERMINATIONS RoHS COMPLIANT SAC SOLDER COMPATIBLE* Temperature Coefficient
Διαβάστε περισσότεραNPN SILICON OSCILLATOR AND MIXER TRANSISTOR
FEATURES NPN SILICON OSCILLATOR AND MIXER TRANSISTOR LOW COST HIGH GAIN BANDWIDTH PRODUCT: ft = MHz TYP LOW COLLECTOR TO BASE TIME CONSTANT: CC r b'b = 5 ps TYP LOW FEEDBACK CAPACITANCE: CRE=.55 pf TYP
Διαβάστε περισσότεραNKT NTC Thermistor. Negative Temperature Coefficient Thermistor FEATURES
FEATURES Large, strong capacity of suppression of inrush current Big material (B value), small residual Small size, Long life, high reliability and fast response APPLICATIONS Switching -supply, switch,
Διαβάστε περισσότεραLS series ALUMINUM ELECTROLYTIC CAPACITORS CAT.8100D. Specifications. Drawing. Type numbering system ( Example : 200V 390µF)
Snap-in Terminal Type, 85 C Standard Withstanding 3000 hours application of rated ripple current at 85 C. Compliant to the RoHS directive (2011/65/EU). LS Smaller LG Specifications Item Category Temperature
Διαβάστε περισσότερα0.635mm Pitch Board to Board Docking Connector. Lead-Free Compliance
.635mm Pitch Board to Board Docking Connector Lead-Free Compliance MINIDOCK SERIES MINIDOCK SERIES Features Specifications Application.635mm Pitch Connector protected by Diecasted Zinc Alloy Metal Shell
Διαβάστε περισσότερα38BXCS STANDARD RACK MODEL. DCS Input/Output Relay Card Series MODEL & SUFFIX CODE SELECTION 38BXCS INSTALLATION ORDERING INFORMATION RELATED PRODUCTS
DCS Input/Output Relay Card Series STANDARD RACK MODEL 38BXCS MODEL & SUFFIX CODE SELECTION 38BXCS MODEL CONNECTOR Y1 :Yokogawa KS2 cable use Y2 :Yokogawa KS9 cable use Y6 :Yokogawa FA-M3/F3XD32-3N use
Διαβάστε περισσότεραLowara SPECIFICATIONS
SH Series Centrifugal pumps entirely made of AISI 36 stainless steel according to EN 733 (ex DIN 24255). Designed to pump hot, cold and moderately aggressive liquids. Available versions: SHE Close-coupled
Διαβάστε περισσότεραEngineering Data High-wall Type (3 series) Indoor Unit. Contents MMK-AP0073H MMK-AP0093H MMK-AP0123H MMK-AP0153H MMK-AP0183H MMK-AP0243H.
E09-311 Engineering Data High-wall Type (3 series) Indoor Unit Model name: MMK-AP0073H MMK-AP0093H MMK-AP0123H MMK-AP0153H MMK-AP0183H MMK-AP0243H Contents 1 Specifications 2 Dimensions 3 Center of gravity
Διαβάστε περισσότεραLowara APPLICATIONS MATERIALS. General Catalogue
FH Series Centrifugal electric pumps according to EN 733 (ex DIN 24255). Electric pumps with pump casing in cast iron and impeller in AISI 36* stainless steel, designed to pump hot, cold and moderately
Διαβάστε περισσότεραGearmotor Data. SERIES GM9000: We have the GM9434H187-R1
SERIES GM9: We have the GM9434H187-R1 Gearmotor Data Item Parameter Symbol Units 5.9:1 11.5:1 19.7:1 38.3:1 65.5:1 127.8:1 218.4:1 425.9:1 728.1:1 1419.8:1 2426.9:1 4732.5:1 1 Max. Load Standard Gears
Διαβάστε περισσότεραAluminum Capacitors C, Tubular, Radial Lead
Aluminum Capacitors + 105 C, Tubular, Radial Lead FEATURES Wide temperature range Radial design in two and three lead configuration Ideal SMPS output filter PERFORMANCE CHARACTERISTICS Operating Temperature:
Διαβάστε περισσότεραLinear diffuser. Dimensions. Description
Dimensions -- + D -- Description is a rectangular linear diffuser in aluminium. is suitable for both supply and exhaust air. is equipped with air guide baffles, making it possible to use for horizontal
Διαβάστε περισσότεραTerminal Contact UL Insulation Designation (provided with) style form system approval Flux tight
eatures A miniature PCB Power Relay. form A contact configuration with quick terminal type. 5KV dielectric strength, K surge voltage between coils to contact. Ideal for high rating Home Appliances of heating
Διαβάστε περισσότεραTerabyte Technology Ltd
Terabyte Technology Ltd is a Web and Graphic design company in Limassol with dedicated staff who will endeavour to deliver the highest quality of work in our field. We offer a range of services such as
Διαβάστε περισσότεραDLG Series. Lowara SPECIFICATIONS APPLICATIONS ACCESSORIES MATERIALS. General Catalogue
DLG Series Submersible pumps with open impeller with grinder assembly for pumping sewage, liquids, wastewater in general and industrial sludge, draining of flooded excavations. SPECIFICATIONS Delivery:
Διαβάστε περισσότεραApplications Water distribution
1 FH Series Centrifugal electric pumps according to EN 733 (ex DIN 24255). Electric pumps with pump casing in cast iron designed to pump clean, chemically non-aggressive water and liquids. Available versions:
Διαβάστε περισσότεραPRELIMINARY DATA SHEET NPN EPITAXIAL SILICON TRANSISTOR FOR MICROWAVE HIGH-GAIN AMPLIFICATION
PRELIMINARY DATA SHEET NPN EPITAXIAL SILICON TRANSISTOR FOR MICROWAVE HIGH-GAIN AMPLIFICATION NE699M FEATURES OUTLINE DIMENSIONS (Units in mm) HIGH ft: 6 GHz TYP at V, ma LOW NOISE FIGURE: NF =. db TYP
Διαβάστε περισσότεραSMD Transient Voltage Suppressors
SMD Transient Suppressors Feature Full range from 0 to 22 series. form 4 to 60V RMS ; 5.5 to 85Vdc High surge current ability Bidirectional clamping, high energy Fast response time
Διαβάστε περισσότερα+85 C Snap-Mount Aluminum Electrolytic Capacitors. High Voltage Lead free Leads Rugged Design. -40 C to +85 C
+85 C Snap-Mount Capacitors FEATURES High ripple Current Ratings Large Case Size Selection Extended Life High Voltage Lead free Leads Rugged Design SPECIFICATIONS Tolerance ±20% at 120Hz, 20 C Operating
Διαβάστε περισσότεραCreative TEchnology Provider
1 Oil pplication Capacitors are intended for the improvement of Power Factor in low voltage power networks. Used advanced technology consists of metallized PP film with extremely low loss factor and dielectric
Διαβάστε περισσότεραSurface Mount Multilayer Chip Capacitors for Commodity Solutions
Surface Mount Multilayer Chip Capacitors for Commodity Solutions Below tables are test procedures and requirements unless specified in detail datasheet. 1) Visual and mechanical 2) Capacitance 3) Q/DF
Διαβάστε περισσότεραTransient Voltage Suppressor
Transient Suppressor Features Glass passivated junction Low incremental surge resistance, excellent clamping capability Underwriters Laboratory Recognition under UL standard for safety 497B: Isolated Loop
Διαβάστε περισσότεραLS01-15B09SS LS01-15B12SS LS01-15B15SS LS01-15B24SS LS03-15B03SR2S LS03-15B05SR2S LS03-15B09SR2S LS03-15B12SR2S LS03-15B15SR2S LS03-15B24SR2S
LS0 SS & LS0RS _ onverter. W SIP economic LS series.... W High performance & compact size series.... W ~0V wide input voltage LH series.... W 0 Low temperature & high reliability L0_LT series.... 00W LH
Διαβάστε περισσότεραData sheet Thick Film Chip Resistor 5% - RS Series 0201/0402/0603/0805/1206
Data sheet Thick Film Chip Resistor 5% - RS Series 0201/0402/0603/0805/1206 Scope -This specification applies to all sizes of rectangular-type fixed chip resistors with Ruthenium-base as material. Features
Διαβάστε περισσότεραPRODUCT IDENTIFICATION SWPA 3012 S 1R0 N T
Wire Wound SMD Power Inductors SWPA Series Operating temperature range: -4 ~+25 (Including self-heating) FEATURES Magnetic-resin shielded conruction reduces buzz noise to ultra-low levels Metallization
Διαβάστε περισσότεραALUMINUM ELECTROLYTIC CAPACITORS LKG
Lug / Snap-in Terminal Type, For Audio Equipment Disigned for high grade audio equipment, giving priority to high fidelity sound quality. The variation expansion of the. TYPE-: The low profile high tone
Διαβάστε περισσότεραAlféa Extensa + and Extensa Duo +
Alféa Extensa + and Extensa Duo + FR Document n 1592-2~ 12/07/2013 EN Heat pumps air/water split 1 service and 2 services Technical manual Intended for professionals Completed by the installation and operating
Διαβάστε περισσότεραCapacitors - Capacitance, Charge and Potential Difference
Capacitors - Capacitance, Charge and Potential Difference Capacitors store electric charge. This ability to store electric charge is known as capacitance. A simple capacitor consists of 2 parallel metal
Διαβάστε περισσότεραSurface Mount Multilayer Inductor
FETURES 0603, 0805, 0806 ND 1008 CSE SIZES HIGH CURRENT ND LOW RESISTNCE NEW "S" VERSION FOR INCRESED STURTION CURRENT UGRDED "H" VERSION FOR HIGHEST CURRENT REFLOW SOLDERING LICBLE CKGE FOR UTOMTIC ICKLCE
Διαβάστε περισσότεραCurrent Sensing Chip Resistor SMDL Series Size: 0201/0402/0603/0805/1206/1010/2010/2512/1225/3720/7520. official distributor of
Product: Current Sensing Chip Resistor SMDL Series Size: 0201/0402/0603/0805/1206/1010/2010/2512/1225/3720/7520 official distributor of Current Sensing Chip Resistor (SMDL Series) 1. Features -3 Watts
Διαβάστε περισσότεραMATRIX. EBARA PUMPS EUROPE S.p.A. HORIZONTAL MULTISTAGE PUMPS
CONTENTS Page - SPECIFICATIONS 200 PUMP SPECIFICATION 200 TYPE KEY 201 SELECTION CHART 202 SELECTION CHART 203 PERFORMANCE CURVE 3 ( 2-3-4-5 impellers ) 204 PERFORMANCE CURVE 3 ( 6-7-8-9 impellers ) 205
Διαβάστε περισσότεραLR Series Metal Alloy Low-Resistance Resistor
Tel : 881745 Fax : 881749 LR Series Metal Alloy LowResistance Resistor This specification is applicable to lead free, halogen free of RoHS directive for metal alloy lowresistance resistor. The product
Διαβάστε περισσότερα1000 VDC 1250 VDC 125 VAC 250 VAC J K 125 VAC, 250 VAC
Metallized Polyester Film Capacitor Type: ECQE(F) Non-inductive construction using metallized Polyester film with flame retardant epoxy resin coating Features Self-healing property Excellent electrical
Διαβάστε περισσότεραAT Surface Mount Package SOT-363 (SC-70) I I Y. Pin Connections B 1 C 1 E 1 E 2 C 2 B , 7:56 PM
AT-3263 Surface Mount Package SOT-363 (SC-7) I I Y Pin Connections B 1 C 1 E 1 E 2 C 2 B 2 Page 1 21.4., 7:6 PM Absolute Maximum Ratings [1] Absolute Thermal Resistance [2] : Symbol Parameter Units Maximum
Διαβάστε περισσότεραMultilayer Chip Inductor
Features -Monolithic structure for high reliability -High self-resonant frequency -Excellent solderability and high heat resistance Construction Applications -RF circuit in telecommunication and other
Διαβάστε περισσότερα2013 REV 01 ELECTRONICS CAPACITORS. DC Applications Metallized Polypropylene Film Self Healing
2013 REV 01 POWER EECTRONICS CAPACITORS C Applications Metallized Polypropylene Film Healing OUR MISSION: POWER EECTRONICS AN SPECIA CAPACITORS M.V. PFC CAPACITORS AN BANKS IGHTING CAPACITORS MOTOR RUN
Διαβάστε περισσότεραthe total number of electrons passing through the lamp.
1. A 12 V 36 W lamp is lit to normal brightness using a 12 V car battery of negligible internal resistance. The lamp is switched on for one hour (3600 s). For the time of 1 hour, calculate (i) the energy
Διαβάστε περισσότεραEE512: Error Control Coding
EE512: Error Control Coding Solution for Assignment on Finite Fields February 16, 2007 1. (a) Addition and Multiplication tables for GF (5) and GF (7) are shown in Tables 1 and 2. + 0 1 2 3 4 0 0 1 2 3
Διαβάστε περισσότεραType 947D Polypropylene, High Energy Density, DC Link Capacitors
Type 947D series uses the most advanced metallized film technology for long life and high reliability in DC Link applications. This series combines high capacitance and very high ripple current capability
Διαβάστε περισσότεραSAW FILTER - RF RF SAW FILTER
FEATURES - Frequencies from 0MHz to 700MHz - Custom specifications available - Industry standard package configurations - Low-loss saw component - Low amplitude ripple - RoHS compliance - Electrostatic
Διαβάστε περισσότεραSunlord Specifications subject to change without notice. Please check our website for latest information. Revised 2018/04/15
Wire Wound SMD Power Inductors SPH Series Operating Temp. : -40 ~+125 (Including self-heating) FEATURES Magnetic-resin shielded construction reduces buzz noise to ultra-low levels Metallization on ferrite
Διαβάστε περισσότεραRC series Thick Film Chip Resistor
RC series Thick Film Chip Resistor Features» Small size and light weight» Compatible with wave and reflow soldering» Suitable for lead free soldering» RoHS compliant & Halogen Free Applications Configuration»
Διαβάστε περισσότεραDC-DC Constant Current Step-Down LED driver LDD-300L LDD-350L LDD-500L LDD-600L LDD-700L CURRENT RANGE
SPECIFICATION ORDER NO. LDD-00L LDD-0L LDD-00L LDD-00L LDD-700L CURRENT RANGE 00mA 0mA 00mA VOLTAGE RANGE Note. ~ VDC for LDD-00~700L/LW ; ~ 8VDC for LDD-00~700LS CURRENT ACCURACY (Typ.) ±% at VDC input
Διαβάστε περισσότεραB37631 K K 0 60
Multilayer Ceramic acitors High; X5R and X7R Chip Ordering code system B37631 K 7 5 K 6 Packaging 6 ^ cardboard tape, 18-mm reel 62 ^ blister tape, 18-mm reel Internal coding acitance tolerance K ^ ± %
Διαβάστε περισσότεραNTC Thermistor:SCK Series
Features. RoHS & HF compliant 2. Body size: Ф5mm ~ Ф 30mm 3. Radial lead resin coated 4. High power rating 5. Wide resistance range 6. Cost effective 7. Operating temperature range: Φ5mm:-40~+50 Φ8~Φ0mm:-40~+70
Διαβάστε περισσότεραDuPont Suva 95 Refrigerant
Technical Information T-95 ENG DuPont Suva refrigerants Thermodynamic Properties of DuPont Suva 95 Refrigerant (R-508B) The DuPont Oval Logo, The miracles of science, and Suva, are trademarks or registered
Διαβάστε περισσότεραHORIZON QUANTUM. Logging
HORIZON QUANTUM High Capacity Packet Microwave System FEATURES NETWORK MANAGEMENT (NMS) Capacity w/accelerator Variable from 10 to 2000 Mbps full duplex CIR Management Access In or out of band 2x capacity
Διαβάστε περισσότεραOutput Power: W. Exclusively distributed by Powerstax
R Series, 50-150W Input Ranges : 9-75 VDC : Single - Dual /, / /, / Triple / ±, /, / ±0, Quad ± / ±, ± / : 50-150 W FEATURES General: to 100 Watts Wide Input Range : 10-7dc 2:1 & 3:1 Input Range High Conversion
Διαβάστε περισσότεραLR Series Metal Alloy Low-Resistance Resistor
LR Series Metal Alloy LowResistance Resistor This specification is applicable to lead free, halogen free of RoHS directive for metal alloy lowresistance resistor. The product is for general purpose. The
Διαβάστε περισσότεραE62 AC Series Features
E62 AC Features Perfect for non-sinusoidal s and pulsed s. Housed in a hermetically sealed aluminum can which is filled with environmentally friendly plant oil as standard. The integrated overpressure
Διαβάστε περισσότεραHigh pressure centrifugal pumps
High pressure centrifugal pumps Wilo-Multivert MVI (North America) Series description H [ft] 3 1 MVI 1 1 1 MVI 1 MVI 3 MVI MVI 1 1 Q [m³/h] Wilo-Multivert-MVI Hz - North America Q [US gpm] H [m] 1 1 1
Διαβάστε περισσότεραC121. External Dimensions (L W) (mm) 0603 [0201] [0402] [0603] [0805]
Multilayer Chip SDV Series Operating Temp. : -55 ~+125 FEATURES SMD type suitable for high density mounting Excellent clamping ratio and quick response time (
Διαβάστε περισσότεραVAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD
VAV TERMINAL UNIT KYODOALLIED TECHNOLOGY PTE LTD R CONTENTS MODEL: KYODO / KYODOR...1 INTRODUCTION...1 APPLICATION...1 VARIABLE AIR VOLUME SYSTEM...1 FEATURES...2 MATERIALS...3 AIR VOLUME CONTROL TYPE...3
Διαβάστε περισσότερα65W PWM Output LED Driver. IDLV-65 series. File Name:IDLV-65-SPEC
~ A File Name:IDLV65SPEC 07050 SPECIFICATION MODEL OUTPUT OTHERS NOTE DC VOLTAGE RATED CURRENT RATED POWER DIMMING RANGE VOLTAGE TOLERANCE PWM FREQUENCY (Typ.) SETUP TIME Note. AUXILIARY DC OUTPUT Note.
Διαβάστε περισσότεραSummary of Specifications
Snap Mount Large High CV High Ripple 85 C Temperature The series capacitors are the standard 85 C, large capacitance, snap-in capacitors from United Chemi-Con. The load life for the series is 2,000 hours
Διαβάστε περισσότεραSafety Barriers. 6 Safety Barriers KP00 III en Preferred products in stock or available at short notice
5-- KP III en Contents Single-Channel INTRINSPAK 9 8 Dual-Channel INTRINSPAK 9 with Electronic Current Limitation INTRINSPAK 94 You will find further information on the Internet www.stahl.de General Information
Διαβάστε περισσότερα