High Static Duct Type (6 series)

Σχετικά έγγραφα
Engineering Data High-wall Type (3 series) Indoor Unit. Contents MMK-AP0073H MMK-AP0093H MMK-AP0123H MMK-AP0153H MMK-AP0183H MMK-AP0243H.

RAC. Technical Data Book. RAC(Quantum) for North America (R410A, 60Hz, HP) Model : AR09/12/18/24KSFPDWQNCV AR09/12/18/24KSFPDWQXCV

MVD. Wall Mounted Split DC Service manual. CL23410 to CL23416 English

RAC. Technical Data Book. RAC(Max Heat) for North America (R410A, 60Hz, HP) Model : AR09/12KSWSPWKNCV AR09/12KSWSPWKXCV

Engineer Reference 1 / / A 35 7/16 X 7 7/8 X 23 5/8 31 1/8 X 21 7/8 X 11 1/4 14 T T 75 R410A oz/ft over 50' 265 / 318 / 388

S /5000 BTU/Hr. 1000/1500 Watt

Air Conditioners Technical Data

4 Way Reversing Valve

SERVICE MANUAL OUTDOOR UNIT

MS15 High-Efficiency Mini-Split System

MS20 High-Efficiency Mini-Split System

Service Manual. Models: GWH09ABA-K6DNA1B GWH09ABA-K6DNC8B GWH12ABA-K6DNA1B GWH12ABA-K6DNC8B (Refrigerant R32) GREE ELECTRIC APPLIANCES,INC.

4 Way Reversing Valve

Model: MTZ22. Data. Cylinder count: 1 Displacement [m³/h]: 6,63 Cylinder capacity [cm³]: 38,1 RPM [min -1 ]: 2900 Weight [kg]: 21 Oil charge [dm³]: 1

EHS. EHS Split (50Hz)

Metal Oxide Varistors (MOV) Data Sheet

Aluminum Electrolytic Capacitors

Split. Air Conditioning Technical Data RXM-M

COPELAND SCROLL AIR COOLED CONDENSING UNITS

ZLW Series. Single-stage Monoblock Centrifugal Pump ZL PUMP GROUP.,LTD

KYOWA PRODUCT CATALOGUE

RSDW08 & RDDW08 series

Aluminum Electrolytic Capacitors (Large Can Type)

38BXCS STANDARD RACK MODEL. DCS Input/Output Relay Card Series MODEL & SUFFIX CODE SELECTION 38BXCS INSTALLATION ORDERING INFORMATION RELATED PRODUCTS

RECOMMENDED SERVICE PARTS LIST Voltage

LS series ALUMINUM ELECTROLYTIC CAPACITORS CAT.8100D. Specifications. Drawing. Type numbering system ( Example : 200V 390µF)

DLG Series. Lowara SPECIFICATIONS APPLICATIONS ACCESSORIES MATERIALS. General Catalogue

Lowara SPECIFICATIONS

DC-DC Constant Current Step-Down LED driver LDD-300L LDD-350L LDD-500L LDD-600L LDD-700L CURRENT RANGE

CSR series. Thick Film Chip Resistor Current Sensing Type FEATURE PART NUMBERING SYSTEM ELECTRICAL CHARACTERISTICS

NMBTC.COM /

Air Conditioning. Technical Data EEDEN RXG-L

A Modular Multi System. Service Manual Air Conditioner - Multi Split Type System HFC R407C

SINGLE. Technical Data Book. Multi-position AHU for North America (R410A, 60Hz, H/P) Model : AC***KNZDCH/AA (IDU) AC***JXADCH/AA (ODU)

(REV:01) RYOBI 48 Volt Lawn Mower Model No. RY14110 Replacement Parts List

Finish: Anticorrosive finish in polyester. Number of motor poles 4=1400 r/min. 50 Hz 6=900 r/min. 50 Hz 8=750 r/min. 50 Hz

MATRIX. EBARA PUMPS EUROPE S.p.A. HORIZONTAL MULTISTAGE PUMPS

Digital motor protection relays

DC-DC Constant Current Step-Down LED driver LDD-300L LDD-350L LDD-500L LDD-600L LDD-700L CURRENT RANGE

Smaller. 6.3 to 100 After 1 minute's application of rated voltage at 20 C, leakage current is. not more than 0.03CV or 4 (µa), whichever is greater.

60W AC-DC High Reliability Slim Wall-mounted Adaptor. SGA60E series. File Name:SGA60E-SPEC

15W DIN Rail Type DC-DC Converter. DDR-15 series. File Name:DDR-15-SPEC

65W PWM Output LED Driver. IDLV-65 series. File Name:IDLV-65-SPEC

+85 C Screw Terminal Aluminum Electrolytic Capacitors. For filtering applications. Capacitance change Dissipation factor Leakage current

15W DIN Rail Type DC-DC Converter. DDR-15 s e r i e s. File Name:DDR-15-SPEC

Surface Mount Multilayer Chip Capacitors for Commodity Solutions

65W PWM Output LED Driver. IDPV-65 series. File Name:IDPV-65-SPEC

UDZ Swirl diffuser. Product facts. Quick-selection. Swirl diffuser UDZ. Product code example:

Metal Oxide Leaded Film Resistor

(REV:01) RYOBI 48 Volt Lawn Mower Model No. RY14110A Replacement Parts List

Lowara APPLICATIONS MATERIALS. General Catalogue

MS SERIES MS DESK TOP ENCLOSURE APPLICATION EXAMPLE FEATURE. Measuring instruments. Power supply equipments

EHS. EHS GEN3 MONO (50Hz)

ALUMINUM ELECTROLYTIC CAPACITORS LKG

Terminal Contact UL Insulation Designation (provided with) style form system approval Flux tight

DVM. Technical Data Book

Metal Oxide Leaded Film Resistor

Current Sensing Chip Resistor SMDL Series Size: 0201/0402/0603/0805/1206/1010/2010/2512/1225/3720/7520. official distributor of

LR(-A) Series Metal Alloy Low-Resistance Resistor

SPARE PARTS LIST. for. Infrared oil heater. Model. Daystar. Type. PH5 for 120V 60Hz. May, 2017

Heat exchanger. Type WT. For the reheating of airflows in rectangular ducting PD WT 1. 03/2017 DE/en

LR Series Metal Alloy Low-Resistance Resistor

IDPV-45 series. 45W PWM Output LED Driver. File Name:IDPV-45-SPEC S&E

HIS series. Signal Inductor Multilayer Ceramic Type FEATURE PART NUMBERING SYSTEM DIMENSIONS HIS R12 (1) (2) (3) (4)

LR Series Metal Alloy Low-Resistance Resistor

OWA-60E series IP67. 60W Single Output Moistureproof Adaptor. moistureproof. File Name:OWA-60E-SPEC

SERVICE. Service Information Frontloader Washing machine AWO/D Last Modification: 02/01/09 AWO/D 45135

Multilayer Chip Inductor

ECOL Motors In Aluminum Housing

No Item Code Description Series Reference (1) Meritek Series CRA Thick Film Chip Resistor AEC-Q200 Qualified Type

Applications Water distribution

Alféa Extensa + and Extensa Duo +

SMD Power Inductor-VLH

Rating to Unit ma ma mw W C C. Unit Forward voltage Zener voltage. Condition

Sunlord. Wire Wound SMD Power Inductors SPH Series Operating Temp. : -40 ~+125 (Including self-heating) 2R2 SPH

CSK series. Current Sensing Chip Resistor. Features. Applications. Construction FAITHFUL LINK

SERVICE. Service Information Frontloader Washing machine AWO/D Last Modification: 02/01/09 AWO/D 5526

TRC ELECTRONICS, INC LED Driver Constant Voltage 45W MEAN WELL IDLV-45 Series

Sunlord Specifications subject to change without notice. Please check our website for latest information. Revised 2018/04/15

A31. Aluminium heat exchanger A31

ACTORS IEC CONT Ex9C

ΜΜ917-Σχεδιασμός Ενεργειακών Συστημάτων

Polymer PTC Resettable Fuse:KMC Series

SERVICE. Service Information Toploader Washing machine AWE 2316/ Last Modification: 01/30/09 AWE 2316/1

SPBW06 & DPBW06 series

the smartest energy Floor standing DHW (Domestic Hot Water) storage tanks for Forced Circulation Solar systems

0.635mm Pitch Board to Board Docking Connector. Lead-Free Compliance

Return Line Filters Type RTF10/25

Electrical Specifications at T AMB =25 C DC VOLTS (V) MAXIMUM POWER (dbm) DYNAMIC RANGE IP3 (dbm) (db) Output (1 db Comp.) at 2 f U. Typ.

2R2. 2 (L W H) [mm] Wire Wound SMD Power Inductor. Nominal Inductance Packing Tape & Reel. Design Code M ±20%

Surface Mount Aluminum Electrolytic Capacitors

SMD Power Inductor-VLH

Ceramic PTC Thermistor Overload Protection

± 20% ± 5% ± 10% RENCO ELECTRONICS, INC.

Anti-Corrosive Thin Film Precision Chip Resistor-SMDR Series. official distributor of

NPI Unshielded Power Inductors

MSN DESK TOP ENCLOSURE WITH STAND / CARRYING HANDLE

MINIATURE ALUMINUM ELECTROLYTIC CAPACITORS. Characteristics. Leakage Current(MAX) I=Leakage Current(µA) C=Nominal Capacitance(µF) V=Rated Voltage(V)

SERIES DATASHEET INDUCTORS RF INDUCTORS (MRFI SERIES)

High hydraulic efficiency Motor designed to EN standards IDENTIFICATION NAME. F - in line ports with ROUND FLANGES (counterflanges on request)

Transcript:

E6-002 High Static Duct Type (6 series) MMD-AP0726HP-E MMD-AP0966HP-E

Contents. Specifications... 2 2. Dimensions.... Center of gravity...5 4. Piping diagram... 6 5. Wiring diagram... 7 6. Electrical characteristics.... 8 7. Sensible capacity table... 9 8. Fan static characteristics... 9. Sound characteristics (NC curve).... Accessories...

. Specifications (/Hz) Model name MMD- AP0726HP-E AP0966HP-E Cooling capacity Note (kw) 22.4 28.0 Heating capacity Note (kw) 25.0.5 Electrical Power supply phase Hz 2V(2V-2V) / phase Hz 2V characteristics Running current (/Hz) (A) 2.80 / 2.9.75 /.92 (factory setting) Power consumption (W) 5 / 5 790 / 790 Starting current (/Hz) (A) 7.80 / 8.5 7.80 / 8.5 Appearance Zinc hot dipping steel plate Dimension Height (mm) 448 Width (mm) 0 Depth (mm) 900 Total weight (kg) 97 Heat exchanger Soundproof / Heat-insulating meterial Finned tube Polyethlene foam Fan unit Fan Centrifugal fan Standard air flow (m/h),800 4,800 (Med./Low) (,0/2,0) (4,0/,0) Motor output (W) 2 External static pressure (factory setting) (Pa) External static pressure range (Pa) -8-7--8-27-2 (7steps) Controller Air filter Drain pump Remote controller Sold separately (TCB-LK280DP-E) Sold separately (TCB-DPDPE) Connecting Gas side (mm) Φ22.2 pipe Liquid side (mm) Φ2.7 Drain port (mm) 25(Polyvinyl chloride tube) Sound pressure level (High/Med./Low) Note 2 (factory setting) (db(a)) 44 / / 6 46 / 42 / 8 Note : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 865 based on the reference piping. The reference piping consists of 5m of main piping and 2.5m of branch piping connected with 0 meter height. Rated conditions Cooling: Indoor air temperature 27 DB/9 WB, Outdoor air temperature 5 DB Heating: Indoor air temperature DB, Outdoor air temperature 7 DB/6 WB Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B 866. Normally, the values measured in the actual operating environment become larger than the indicated valves due to the effects of external sound. 2

2. Dimensions Contents MMD-AP0726HP-E, MMD-AP0966HP-E. Specifications... 2. Dimensions... 4. Center of gravity...6 4. Piping diagram... 7 5. Wiring diagram... 8 6. Electrical characteristics.... 9 7. Sensible capacity table... /0 or more downward 90 or less Flexible drain hose (Accessory) 0 or less 0 or less Space required for installation and servicing Flexible drain hose (Accessory) () Unit external dimension 0 /0 or more downward Drain-up piping At the time of natural drainage Ceiling 0 or more 25 25 4 00 or more Air outlet 0 or more Check port 0 00 or more Service space 0 or more or more 448 5 or more Hanging bolt mounting pitch 45 8 45 5 778 900 2 90 90 90 27 296(Outside) Hanging bolt mounting pitch 465 Air outlet Air inlet Service door (Ceiling opening) Floor surface Ceiling 25 25 9 Service door (Ceiling opening) Ceiling 25 25 9 Air inlet 0 or more Service door (Ceiling opening) Electrical control box 4 2 22 84 24 (Outside) 448 5 95 Drain pump kit (sold separately) Hole for hanging bolt (4-Φ2 ) Refrigerant pipe connecting port (Liquid side) O 2.7 Refrigerant pipe connecting port (Gas side) O 22.2 Drain pipe connecting port 8. Fan static characteristics... 2 9. Sound characteristics (NC curve)... 4. Accessories...24 Drain pipe connecting port (Gravitiational drainage) If there are enough space under the unit (more than 00mm) the service door(ceiling opening) is not necessary. When attached the drain pump kit (sold separately) 74 8 or more (Suction duct) < When attached the long life filter kit (sold separately)> (Flare nut connection) (Brazing connection) (Unit:mm) 2

Contents MMD-AP0726HP-E, MMD-AP0966HP-E. Specifications... Duct arrangement 2. Dimensions... 4. Center of gravity...6 <Air outlet> 4. Piping diagram... 7 5. Wiring diagram... 8 6. Electrical characteristics.... 9 7. Sensible capacity table... 8. Fan static characteristics... 2 9. Sound characteristics (NC curve)... 4 296(Outside). Accessories...24 24 (Outside) 84 9800000000000 98 8 7 27 90 90 90 27 44 <Air inlet> 6 58 0 0 0 0 0 0 58 4 2 8 84 4 44 6 6 297 6 44 0 0 0 0 0 0 58 4 Electrical control box MMD-AP MMD-AP (Unit:mm) 4 2

. Center of gravity Model : MMD-AP0726HP-E, MMD-AP0966HP-E Model name X (mm) Y(mmm) Z(mm) Total weight (kg) MMD-AP0726HP-E 665 45 2 97 MMD-AP0966HP-E X Z Y 5

4. Piping diagram Model : MMD-AP0726HP-E, MMD-AP0966HP-E Liquid side Gas side Strainer Capillary tube Air heat exchanger at indoor side Pulse Motor Valve (PMV) Sensor (TC2) Strainer Sensor (TCJ) Sensor (TA) Fan M Fan motor Sensor (TC) Functional part name Functional outline Pulse Motor Valve PMV (Connector CN082 (6P): Blue) ) Controls super heat in cooling operation 2) Controls sub cool in heating operation ) Recovers refrigerant oil in cooling operation 4) Recovers refrigerant oil in heating operation Temp. sensor. TA (Connector CN4 (2P): Yellow) ) Detects indoor suction temperature 2. TC (Connector CN0 (P): Brown) ) Controls PMV super heat in cooling operation. TC2 (Connector CN (2P): Black) ) Controls PMV sub cool in heating operation 4. TCJ (Connector CN2 (2P): Red) ) Controls PMV super heat in cooling operation 6

5. Wiring diagram Model : MMD-AP0726HP-E, MMD-AP0966HP-E Concealed Duct High Static Pressure Type Wiring Diagram 6 RB 4 Color Indication RED : Red WHI : White YEL : Yellow BLU : Blue BLK : Black BRW : Brown M DM Drain Pump Kit (Option) 0 BRW BRW RY0 RY02 5 8 7 MCC-6 CN4 (BLU) CN0 (WHI) + + + - 2 4 5 Fan Control P.C. Board 5 4 2 CN5 (RED) CN2 (BLK) 2 CN2 (WHI) 2 F0 5A 2V CN5 CN4 CN U V W RED WHI BLK 4 CN5 CN5 - Drain Pump Kit Attached (Option) CN4 FS (RED) L-FM TA t 2 2 CN4 CN2 (YEL) (RED) 2 9 8 7 6 5 4 2 9 8 7 6 5 4 2 7 6 5 4 2 CN2 (WHI) CN4 (RED) TCJ CN4 (WHI) CN5 (WHI) TC2 2 CN (BLK) TC t t t 2 CN0 (BRW) SW ON 2 (External Static Pressure Set Up) CN52 (RED) CN7 CN72 Control P.C. Board for Indoor Unit MCC-64 2 4 5 6 2 4 5 CN82 CN8 (BLU) (BLK) (CHK) (DISP) + M DCV DC5V DC2V DC 7V Power Supply Circuit PMV 6 5 FLEX + - CN (BLU) CN2 (WHI) CN6 (YEL) 4 5 2 2 4 5 6 2 2 4 5 CN9 (YEL) 4 UART WHI RED CN04 CN0 Noise Filter P.C. Board MCC-55 CN08 MS P0 CN02 CN0 FM WHI RED Flow Selector Unit (Option) F0 T6.A 2V RED 5 CN67 (BLK) WHI CN22 (BLK) UU2 CN (BLU) 2 CN4 (BLU) 2 BLU BLU BLK BLK U U2 A B A B TB02 WHI 2 BLK Sold Separately Symbol CN** F0,F0 FM L-FM PMV RB RY0,02 TA TB0,02 TC,TC2,TCJ DM FS Parts Name Connector Fuse Fan Motor Reactor Pulse Motor Valve Rush Current Protect Resistor Relay Indoor Temp Sensor Terminal Block Temp Sensor Drain Pump Motor Float Switch TB0 (L)2(N) Indoor Unit Earth Screw Power Supply 2-2V Hz 2V Hz 4 Flow Selector Unit Earth Screw Outdoor Unit Wired Remote Controller Field Wiring Protective Earth Terminal Block Terminal Connector P.C.Board Accessory Adapter for Wireless Remote Controller M M 7

6. Electrical characteristics Model : MMD-AP0726HP-E, MMD-AP0966HP-E. Hz Model Nominal Voltage Voltage Range Fan Motor Power Supply (V-Ph-Hz) Min Max kw FLA MCA MOCP MMD-AP0726HP-E 2-- 98 264.000 4. 5.2 5 MMD-AP0966HP-E 2-- 98 264.000 5. 6.6 5 2. Hz Model Nominal Voltage Voltage Range Fan Motor Power Supply (V-Ph-Hz) Min Max kw FLA MCA MOCP MMD-AP0726HP-E 2-- 98 242.000 4. 5.4 5 MMD-AP0966HP-E 2-- 98 242.000 5.5 6.9 5 MCA MOCP FLA kw : Minimum Circuit Amps : Maximum Overcurrent Protection (Amps) : Full Load Amps : Fan Motor Rated Output (kw) 8

7. Sensible capacity table Concealed Duct High Static Pressure Type (MMD-AP***6HP-E) (For SMMS-e, Mini-SMMS-e) TC : Total capacity [kw] SHC : Sensible capacity [kw] indoor air temp. unit outdoor 4 WB 6 WB 8 WB 9 WB WB 22 WB 24 WB size air temp. DB 2 DB 26 DB 27 DB 28 DB DB 2 DB DB T SH T SH T SH T SH T SH T SH T SH.0 8.4 6.6. 7.6 2.7 8.7 22.4 8.7 2. 8.7 24.4 8.5 25.5 8. 2.0 8.4 6.6. 7.6 2.7 8.7 22.4 8.7 2. 8.7 24.4 8.5 25.5 8. 4.0 8.4 6.6. 7.6 2.7 8.7 22.4 8.7 2. 8.7 24.4 8.5 25.5 8. 6.0 8.4 6.6. 7.6 2.7 8.7 22.4 8.7 2. 8.7 24.4 8.5 25.5 8. 8.0 8.4 6.6. 7.6 2.7 8.7 22.4 8.7 2. 8.7 24.4 8.5 25.5 8..0 8.4 6.6. 7.6 2.7 8.7 22.4 8.7 2. 8.7 24.4 8.5 25.5 8. 2.0 8.4 6.6. 7.6 2.7 8.7 22.4 8.7 2. 8.7 24.4 8.5 25.5 8. 072 2.0 8.4 6.6. 7.6 2.7 8.7 22.4 8.7 2. 8.7 24.4 8.5 25.5 8. 25.0 8.4 6.6. 7.6 2.7 8.7 22.4 8.7 2. 8.7 24.4 8.5 25.5 8. 27.0 8.4 6.6. 7.6 2.7 8.7 22.4 8.7 2. 8.7 24.4 8.5 25.5 8. 29.0 8.4 6.6. 7.6 2.7 8.7 22.4 8.7 2. 8.7 24.4 8.5 25.5 8..0 8.4 6.6. 7.6 2.7 8.7 22.4 8.7 2. 8.7 24.4 8.5 25.5 8..0 8.4 6.6. 7.6 2.7 8.7 22.4 8.7 2. 8.7 24.4 8.5 25.5 8. 5.0 8.4 6.6. 7.6 2.7 8.7 22.4 8.7 2. 8.7 24.4 8.5 25.5 8. 7.0 7.8 6.0 9.7 7. 2.0 8. 2.7 8. 22. 8. 2.6 7.9 24.7 7.5 9.0 7. 5.6 9. 6.6.4 7.6 2. 7.6 2.7 7.6 2.0 7.4 24.0 7.0.0 2.0.9 25.4 22.2 27.2 2.6 28.0 2.5 28.8 2.5.5 2..9 22.8 2.0 2.0.9 25.4 22.2 27.2 2.6 28.0 2.5 28.8 2.5.5 2..9 22.8 4.0 2.0.9 25.4 22.2 27.2 2.6 28.0 2.5 28.8 2.5.5 2..9 22.8 6.0 2.0.9 25.4 22.2 27.2 2.6 28.0 2.5 28.8 2.5.5 2..9 22.8 8.0 2.0.9 25.4 22.2 27.2 2.6 28.0 2.5 28.8 2.5.5 2..9 22.8.0 2.0.9 25.4 22.2 27.2 2.6 28.0 2.5 28.8 2.5.5 2..9 22.8 2.0 2.0.9 25.4 22.2 27.2 2.6 28.0 2.5 28.8 2.5.5 2..9 22.8 096 2.0 2.0.9 25.4 22.2 27.2 2.6 28.0 2.5 28.8 2.5.5 2..9 22.8 25.0 2.0.9 25.4 22.2 27.2 2.6 28.0 2.5 28.8 2.5.5 2..9 22.8 27.0 2.0.9 25.4 22.2 27.2 2.6 28.0 2.5 28.8 2.5.5 2..9 22.8 29.0 2.0.9 25.4 22.2 27.2 2.6 28.0 2.5 28.8 2.5.5 2..9 22.8.0 2.0.9 25.4 22.2 27.2 2.6 28.0 2.5 28.8 2.5.5 2..9 22.8.0 2.0.9 25.4 22.2 27.2 2.6 28.0 2.5 28.8 2.5.5 2..9 22.8 5.0 2.0.9 25.4 22.2 27.2 2.6 28.0 2.5 28.8 2.5.5 2..9 22.8 7.0 22..2 24.6 2.5 26. 22.8 27. 22.8 27.9 22.8 29.5 22.6.9 22.0 9.0 2.6 9.6 2.9.9 25.6 22.2 26. 22. 27. 22. 28.7 2.9.0 2.4 9

8. Fan static characteristics High Static Duct Type (6 series) MMD-AP0726HP-E External Static Pressure (Pa) 25 Mid(2Pa) 0 Mid(27Pa) Mid(8Pa) 275 Mid(Pa,7Pa) 2 225 0 75 25 0 Low Standard Air Flow : 800 (m/h) High(2Pa) High(27Pa) High(8Pa) High(Pa) High(7Pa) High(8Pa) High(Pa) 75 0 Mid(Pa,7Pa) High(8Pa) 0 25 Mid(8Pa) Mid(8Pa) High(Pa) Mid(Pa) 0 Mid(Pa) 0 800 20 20 00 800 40 800 20 20 00 800 40 Air Flow (m/h) Air Flow (m/h) Fan Speed (rpm) 0 0 0 00 900 800 Mid(2Pa) Mid(27Pa) Mid(8Pa) Low Standard Air Flow : 800 (m/h) High(2Pa) High(27Pa) High(8Pa) High(Pa) High(7Pa) MMD-AP0966HP-E External Static Pressure (Pa) Standard Air Flow : 4800 (m/h) Mid(2Pa) 25 Mid(27Pa) 0 Mid(8Pa) Mid(Pa,7Pa) 275 High(2Pa) 2 High(27Pa) 225 Low High(8Pa) High(Pa) 0 High(7Pa) 75 High(8Pa) High(Pa) 25 0 75 25 Mid(8Pa) 0 Mid(Pa) 2800 00 40 4800 50 50 00 Air Flow (m/h) Fan Speed (rpm) 0 0 0 00 900 Mid(2Pa) Mid(27Pa) Mid(8Pa) Low Standard Air Flow : 4800 (m/h) High(2Pa) High(27Pa) High(8Pa) High(Pa) High(7Pa) 800 High(8Pa) Mid(Pa,7Pa) Mid(8Pa) High(Pa) 0 Mid(Pa) 2800 00 40 4800 50 50 00 Air Flow (m/h)

9. Sound characteristics (NC Curve) MMD-AP0726HP-E Air damper Air Urethane Duct Urethane Duct.5m 2.0m or over 2.0m or over Measuring location Rear air intake Extarnal static pressure Pa NC- NC- NC- NC- 6 25 2 0 00 00 00 8000 Air ESP Sound Pressure Level(dBA) (Pa) H M L 42.5 8.5 4.5 8 4.0 9.0 5.0 7 4.5 9.5 5.5 44.0.0 6.0 8 45.0 4.0 7.0 27 46.0 42.0 8.0 2 47.0 4.0 9.0 Extarnal static pressure 8Pa Extarnal static pressure 8Pa NC- NC- NC- NC- 6 25 2 0 00 00 00 8000 NC- NC- NC- NC- 6 25 2 0 00 00 00 8000 Extarnal static pressure 7Pa Extarnal static pressure 27Pa NC- NC- NC- NC- 6 25 2 0 00 00 00 8000 NC- NC- NC- NC- 6 25 2 0 00 00 00 8000 Extarnal static pressure Pa Extarnal static pressure 2Pa NC- NC- NC- NC- 6 25 2 0 00 00 00 8000 NC- NC- NC- NC- 6 25 2 0 00 00 00 8000

MMD-AP0966HP-E Air damper Air Urethane Duct Urethane Duct Air ESP (Pa) Sound Pressure Level(dBA) H M L.5m 2.0m or over 2.0m or over Measuring location Rear air intake Extarnal static pressure Pa NC- NC- NC- NC- 6 25 2 0 00 00 00 8000 44.5.5 6.5 8 45.0 4.0 7.0 7 45.5 4.5 7.5 46.0 42.0 8.0 8 47.0 4.0 9.0 27 48.0 44.0.0 2 49.0 45.0 4.0 Extarnal static pressure 8Pa Extarnal static pressure 8Pa NC- NC- NC- NC- 6 25 2 0 00 00 00 8000 NC- NC- NC- NC- 6 25 2 0 00 00 00 8000 Extarnal static pressure 7Pa Extarnal static pressure 27Pa NC- NC- NC- NC- 6 25 2 0 00 00 00 8000 NC- NC- NC- NC- 6 25 2 0 00 00 00 8000 Extarnal static pressure Pa Extarnal static pressure 2Pa NC- NC- NC- NC- 6 25 2 0 00 00 00 8000 NC- NC- NC- NC- 6 25 2 0 00 00 00 8000 2

. Accessories List Parts name Model name Applied model Long life filter Kit TCB-LK280DP-E MMD-AP0726,0966HP-E Drain pump Kit TCB-DPDPE MMD-AP0726,0966HP-E Shape Model name Shape Attached shape on the duct unit TCB-LK280DP-E TCB-DPDPE External dimension TCB-LK280D-E

TOSHIBA CARRIER (THAILAND) CO.,LTD. 44/9 Moo 5, Bangkadi Industrial Park, Tivanon Road, Tambol Bangkadi, Amphur Muang, Pathumthani 0, Thailand Copyright 4 TOSHIBA CARRIER (THAILAND), All Rights Reserved Notice : Toshiba is committed to continuously improving its products to ensure the highest quality and reliability standard, and to meet local regulations and market requirements. All features and specifications are subject to change without prior notice.