High hydraulic efficiency Motor designed to EN standards IDENTIFICATION NAME. F - in line ports with ROUND FLANGES (counterflanges on request)

Σχετικά έγγραφα
Vertical multistage centrifugal pumps in AISI 316 stainless steel

VERTICAL MULTI-CELL CENTRIFUGAL PUMPS IN AISI 316 STAINLESS STEEL

Lowara SPECIFICATIONS

Lowara APPLICATIONS MATERIALS. General Catalogue

Applications Water distribution

High pressure centrifugal pumps

50 Hz n= 1450 rpm. Standardised EN 733 centrifugal pumps. PERFORMANCE RANGE Flow rate up to 3000 l/min (180 m³/h) Head up to 24 m INSTALLATION AND USE

DLG Series. Lowara SPECIFICATIONS APPLICATIONS ACCESSORIES MATERIALS. General Catalogue

FDL - FXDL FBDL SERIES

HORIZONTAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS in AISI 304

MATRIX. EBARA PUMPS EUROPE S.p.A. HORIZONTAL MULTISTAGE PUMPS

LOWARA e-nsce, e-nscs, e-nscf

- CONSTRUCTIONS 300 SECTIONAL VIEW MATRIX SECTIONAL VIEW MATRIX CONSTRUCTIONS 302 CONSTRUCTIONS 303 MECHANICAL SEAL 304

HORIZONTAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS in AISI 304

- DIMENSIONS AND WEIGHT 400 PUMP MATRIX PUMP DRAWING MATRIX 5/10/ PUMP TABLE MATRIX 5/10/ PACKING 403

MATRIX HORIZONTAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS. Your Life, our Quality. Worldwide.

ZLW Series. Single-stage Monoblock Centrifugal Pump ZL PUMP GROUP.,LTD

- DIMENSIONS AND WEIGHT 400 PUMP MATRIX PUMP DRAWING MATRIX DIMENSION TABLE MATRIX PACKING 403

Submittal Data Sheet Wilo Stratos Z - High Efficiency Domestic Hot Water Circulator

Comeo Type Series Booklet

[bar] 0,5 (7.3 PSI) maximum continuous pressure - maximum working pressure, at which the pump can be operated without time limitation.

[bar] 0,5 (7.3 PSI) maximum continuous pressure - maximum working pressure, at which the pump can be operated without time limitation.

Finish: Anticorrosive finish in polyester. Number of motor poles 4=1400 r/min. 50 Hz 6=900 r/min. 50 Hz 8=750 r/min. 50 Hz

Page - DIMENSIONS AND WEIGHT 400 PUMP DRAWING 400 DIMENSIONS PUMP TABLE 401 PACKING 402

Return Line Filters Type RTF10/25

Heat exchanger. Type WT. For the reheating of airflows in rectangular ducting PD WT 1. 03/2017 DE/en

Model: MTZ22. Data. Cylinder count: 1 Displacement [m³/h]: 6,63 Cylinder capacity [cm³]: 38,1 RPM [min -1 ]: 2900 Weight [kg]: 21 Oil charge [dm³]: 1

BALL VALVE NP - LEVE 754. Range of application: Temperature range: Perform standard: Order information: Paint: Soft seal Ball valve.

Replacement Guide. Wilo Circulators for Heating and Secondary Hot Water Circulation. Pioneering for You

Group 30. Contents.

4 Way Reversing Valve

7AAC63-90 SINGLE-PHASE MOTORS PERMANENT CAPACITOR 7AACC SINGLE-PHASE MOTORS CAP START - CAP RUN. squirrel cage induction motors 7AACC63-100

TECHNICAL DATA Date 12/22/15 Series 50GF22.2

4 Way Reversing Valve

Siemens AG Rated current 1FK7 Compact synchronous motor Natural cooling. I rated 7.0 (15.4) 11.5 (25.4) (2.9) 3.3 (4.4)

COPELAND SCROLL AIR COOLED CONDENSING UNITS

RSDW08 & RDDW08 series

SIEMENS Squirrel Cage Induction Standard Three-phase Motors

MVSI. Technical features. Motor shaft In treated steel alloy (Isothermic hardening) resistant to stress.

Aluminum Electrolytic Capacitors (Large Can Type)

ECOL Motors In Aluminum Housing

QUICKTRONIC PROFESSIONAL QTP5

Specification. code ±1.0 ±1.0 ±1.0 ±1.0 ±0.5 approx (g)

Creative TEchnology Provider

± 20% (rated cap. [µf] ) 1000 Leakage Current: For capacitance values > 33000µF, add the value of:

Multilayer Ceramic Chip Capacitors

LEVITEC INDUSTRIAL BOILERS Steam Way S /5

Long 3000 hour life at 105 C with high ripple current capability 2 and 3 pin versions available Can vent construction

ELWOOD HIGH PERFORMANCE MOTORS H-SERIES MOTOR DATA

Aluminum Capacitors C, Tubular, Radial Lead

LEVITEC INDUSTRIAL BOILERS Steam Way S /5

Περιγραφή κατασκευαστικής σειράς: Wilo-Drain MTS

Aluminum Electrolytic Capacitors

ΕΞΑΡΤΗΜΑΤΑ ΥΔΡΑΥΛΙΚΑ. Hydraulic Fittings. Threaded plastic accessories with both male, and female type thread for use in hydraulic networks.

Interference Suppression Capacitor

Μηχανές Ηλεκτροσύντηξης & Μετ. Συγκόλλησης Εξαρτήματα Ηλεκτροσύντηξης & Μετωπικής Συγκόλλησης PΕ100 Υδρόμετρα Αντλίες

MS SERIES MS DESK TOP ENCLOSURE APPLICATION EXAMPLE FEATURE. Measuring instruments. Power supply equipments

Multilayer Ceramic Chip Capacitors

, / 230 4,6 / 2, , / 230 5,4 / 2,7

Aerovox Corp. Type H High Voltage AC & DC Capacitors. Film Capacitors for Power Electronics Applications. RoHS Compliant. Highlights.

Submersible MOTORS PRODUCT CATALOGUE

Units For Electro-fusion & Butt-fusion Electro-fusion & Butt-fusion Fittings HDPE-100 Hydrometers Pumps

Karta Katalogowa CATALOGUE CARD

MSN DESK TOP ENCLOSURE WITH STAND / CARRYING HANDLE

PEH C High CV-value Long Life, > 10 years at 50 C Low ESR and ESL High stability, 10 years shelf life

Borehole Pumps. SCUBA SERIES Close-coupled submersible pumps for 5 wells. GS 4 SERIES Submersible pumps for 4 wells

ΦΥΓΟΚΕΝΤΡΕΣ ΑΝΤΛΙΕΣ CENTRIFUGAL PUMPS

B37631 K K 0 60

15W DIN Rail Type DC-DC Converter. DDR-15 series. File Name:DDR-15-SPEC

Pipe E235N (St 37.4 NBK) phosphated and oiled

E62-TAB AC Series Features

e-sh Series ErP 2009/125/EC 50 Hz

Series of Wafer Check Valves Design:API 594, API 6D

the smartest energy Floor standing DHW (Domestic Hot Water) storage tanks for Forced Circulation Solar systems

MS20 High-Efficiency Mini-Split System

GAUGE BLOCKS. Grade 0 Tolerance for the variation in length. Limit deviation of length. ± 0.25μm. 0.14μm ±0.80μm. ± 1.90μm. ± 0.40μm. ± 1.

15W DIN Rail Type DC-DC Converter. DDR-15 s e r i e s. File Name:DDR-15-SPEC

ΕΒΑΘ ΑΝΤΛΙΕΣ EVATH PUMPS.

Return Line Filters. Return Line Filters Type RTF10/25. C Technology. Filtration. Product Description. Technical Data. Options and Accessories

Type 441 DIN 442 DIN. Flanged Safety Relief Valves spring loaded

MOTORI PER VENTILATORI MOTORS FOR BLOWERS

NMBTC.COM /

Technical Report. General Design Data of a Three Phase Induction Machine 90kW Squirrel Cage Rotor

Westfalia Bedienungsanleitung. Nr

Ventilated Distribution Transformers

+85 C General Purpose Miniature Aluminum Capacitors

Thin Film Chip Resistors

NPI Unshielded Power Inductors

Smaller. 6.3 to 100 After 1 minute's application of rated voltage at 20 C, leakage current is. not more than 0.03CV or 4 (µa), whichever is greater.

Multilayer Chip Capacitors C0G/NP0/CH

SPBW06 & DPBW06 series

ΚΩΔΙΚΟΣ- CODE 5535G001303P 5535GGF1303P 5535GWL1303P 5535G GGF GWL G

LS series ALUMINUM ELECTROLYTIC CAPACITORS CAT.8100D. Specifications. Drawing. Type numbering system ( Example : 200V 390µF)

Engineering Data High-wall Type (3 series) Indoor Unit. Contents MMK-AP0073H MMK-AP0093H MMK-AP0123H MMK-AP0153H MMK-AP0183H MMK-AP0243H.

2R2. 2 (L W H) [mm] Wire Wound SMD Power Inductor. Nominal Inductance Packing Tape & Reel. Design Code M ±20%

Contactors & Thermal Overload Relays

ΙΑΤΡΙΚΟΣ ΕΞΟΠΛΙΣΜΟΣ ΑΝΑΛΩΣΙΜΑ ΕΞΕΤΑΣΤΙΚΟΙ ΦΑΚΟΙ & ΦΩΤΙΣΜΟΣ

Data sheet Thick Film Chip Resistor 5% - RS Series 0201/0402/0603/0805/1206

UDZ Swirl diffuser. Product facts. Quick-selection. Swirl diffuser UDZ. Product code example:

TM ZX. Copeland EazyCool TM. ZX Digital. Μηχανήµατα Εξωτερικής Χρήσης

Transcript:

VLR/VLRI/VLR VLR Vertical multistage centrifugal pumps The VLR are vertical multistage, in-line, centrifugal pumps, directly connected to an electric motor. They are not self-priming. High hydraulic efficiency Motor designed to EN standards IDENTIFICATION NAME e VLR 16 4 F T T = Three phase M = Single phase F - in line round flange A - in line oval flange V with couplings for VICTAULIC joints Number of stages 1 Nominal flow in mc3/h Material used: = AISI 316 I = AISI 34 Model IE2 motor MATERIALS VERSIONS F - in line ports with ROUND FLANGES (counterflanges on request) A - in line ports with OVAL FLANGES equipped with gas counterflanges V - in line ports with couplings for VICTAULIC joints VLR 2B VLRI VLR VLR 4 VLRI VLR VLR 8 VLRI VLR 16 VLR VLRI VLR 32 VLR 33 VLR 46 66 92 VLR VLR VLR VLR VLR VLR 8

performance range VLR/VLRI/VLR PERFORMANCE RANGE H [m] VLR 3 2 VLR 66 VLR 2B VLR 4 VLR 8 VLR 16 VLR 32 VLR 46 VLR 92 1 9 8 7 6 5 4 3 2 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 Q [m 3 /h] VLRI/VLR H [m] 3 2 VLR 66 VLR 2B VLRI 2B VLR 4 VLRI 4 VLR 8 VLRI 8 VLR 16 VLRI 16 VLR 33 VLR 46 VLR 92 1 9 8 7 6 5 4 3 2 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 Q [m 3 /h] 9

VLR VLR Vertical multistage centrifugal pumps The VLR are vertical multistage, in-line, centrifugal pumps, directly connected to an electric motor. They are not self-priming. High hydraulic efficiency Stainless steel hydraulic end Motor designed to EN standards APPLICATIONS Water supply Pressure Booster Systems Irrigation High pressure washes Firefighting systems Boiler supply Liquid transfer MOTOR Asynchronous electric motor with enclosed stator and external ventilation Efficiency motor s class IE2 Main dimensions are in accordance with DIN and IEC standards Design: V18-up to 4,Kw V1- to start from 5,5Kw Class F insulation Level of protection IP 55 Maximum environmental temperature 4 C Speed of rotation 29 rpm Increased bearings to last longer VERSIONS AVAILABLE Impeller, diffuser and outside sleeve in stainless steel Cast iron base, adapter and motor bracket VLR 32 and VLR 66 are equipped with cartridge mechanical seal, in order to avoid a motor disassembling in case of replacement A version with oval flanges, supplied complete with counterflanges F with round DIN type flanges DESIGN FEATURES COMPONENT VLR 2B - 4-8 -16 VLR 32 VLR 46-66 - 92 1 Pump casing cast iron EN GJL 2 cast iron EN GJL 5-7U cast iron EN GJL 25 2 Motor bracket cast iron EN GJL 2 cast iron EN GJL 2 cast iron EN GJL 2 3 Motor joint cast iron EN GJS 4 cast iron EN GJL 5-7U cast iron EN GJL 2 4 Sleeve Stainless steel 5CrNi18-1 (AISI 34) 5 Impeller Stainless steel 5CrNi18-1 (AISI 34) 6 Diffuser Stainless steel 5CrNi18-1 (AISI 34) Stainless steel 2C Nimo17-12-2 (AISI 316L) Stainless steel 2C Nimo17-12-2 (AISI 316L) Stainless steel Nimo17-12-2 (AISI 316L) 7 Rotating seal silicon carbide Tungsten carbide silicon carbide 8 Stationary seal Graphite Graphite Graphite 9 Shaft Stainless steel 2CrNiMo17-12-2 (AISI 316L) Stainless steel 17CrNi16-2 (AISI 316L) Stainless steel 2CrNiMoN22-5-3 (AISI 316L) 1 Gaskets/Seals EPDM 1

usage limitation VLR USAGE LIMITATION VLR 2B VLR 4 VLR 8 VLR 16 Oval flanges DIN Flanges Oval flanges DIN Flanges DIN Flanges Liquid temperature -15 to +12 C -15 to +12 C -15 to +12 C Maximum operating pressure (suction head included) 16 bar 25 bar (max temp 4 C) 25 bar (max temp 4 C) 16 bar 21 bar (max temp 12 C) 21 bar (max temp 12 C) VLR16-3 - 2 - VLR16-1 25 bar (max temp 85 C) VLR16-3 -2 - VLR16-3 23 bar (max temp 12 C) Minimum suction head Please refer to the NPSH values with a safety margin of,5 m USAGE LIMITATION VLR 32 VLR 46 VLR 66 VLR 92 DIN Flanges DIN Flanges DIN Flanges DIN Flanges Liquid temperature -2 to +12 C -3 to +12 C -3 to +12 C -3 to +12 C Maximum operating pressure (suction head included) 25 bar 16 bar up to VLR 46-5 25 bar up to VLR46-9 4 bar up to VLR 46-13/2 16 bar up to VLR 66-5 25 bar up to VLR 66-8 16 bar up to VLR 92-4 25 bar up to 92-7/2 Minimum suction head Please refer to the NPSH values with a safety margin of,5 m 11

VLR 2B HYDRAULIC PERFORMANCE 3 6 9 12 15 Q[lmp gpm] 3 6 9 12 15 18 Q[US gpm] 26 24 2B-26 8 22 2 18 16 14 12 1 8 6 4 2 2B-22 2B-18 2B-15 2B-13 2B-11 2B-9 2B-7 2B-6 2B-5 2B-4 2B-3 2B-3/2 7 6 5 4 3 2 1 H[m],6 1,2 1,8 2,4 3 3,6 4,2 Q[m 3 /h] H[ft] 14 28 42 56 7 Q[l/min] P p [kw],12 5,1,8,6 kw/stage η 4 3 2 η[%] NPSH[m] 4 3 2 1 NPSH Head and NPHS valid for water with p=1, kg/dm 3 at 2 C of condensity VLR 2B 29 rpm 5 Hz ISO 996 - Annex A 12

pump features VLR 2B PUMP PERFORMANCE Motor Power L/1 1 2 3 4 5 HP kw Voltage In (A) μf. Q m 3 /h,6 1,2 1,8 2,4 3 Version with oval flanges VLR 2B 3/2 VLR 2B 15 VLR 2B - 3/2 A M VLR 2B - 3/2 A T,5,37 1~23 V 3~23 4 V 2,8 1,7-1, 12,5 18 17 16 13 1 VLR 2B - 3 A M VLR 2B - 3 A T,5,37 1~23 V 3~23 4 V 2,8 1,7-1, 12,5 27 26 23 2 15 VLR 2B - 4 A M VLR 2B - 4 A T,75,55 1~23 V 3~23 4 V 4,2 2,6-1,5 16 36 34 31 26 2 VLR 2B - 5 A M VLR 2B - 5 A T,75,55 1~23 V 3~23 4 V 4,2 2,6-1,5 16 45 43 39 33 25 VLR 2B - 6 A M VLR 2B - 6 A T 1,75 1~23 V 3~23 4 V 5 3,5-2 25 54 51 46 39 3 VLR 2B - 7 A M VLR 2B - 7 A T VLR 2B - 9 A M VLR 2B - 9 A T 1,75 1,5 1,1 1~23 V 3~23 4 V 1~23 V 3~23 4 V 5 3,5-2 7,9 4,5-2,6 25 31,5 m.c.a. / m.c.w. 64 6 54 46 35 82 77 7 59 45 VLR 2B - 11 A M VLR 2B - 11 A T 1,5 1,1 1~23 V 3~23 4 V 7,9 4,5-2,6 31,5 1 94 85 72 55 VLR 2B - 13 A M VLR 2B - 13 A T 2 1,5 1~23 V 3~23 4 V 1,5 6,1-3,5 36 118 111 11 85 65 VLR 2B - 15 A M VLR 2B - 15 A T 2 1,5 1~23 V 3~23 4 V 1,5 6,1-3,5 36 136 128 116 99 75 VLR 2B - 18 F T 3 2,2 3~23 4 V 8,5-4,9 163 154 139 118 9 VLR 2B - 22 F T 3 2,2 3~23 4 V 8,5-4,9 199 188 17 144 11 VLR 2B - 26 F T 4 3 3~23 4 V 11,6-6,7 235 222 21 17 13 - Type A : with 1 (DN 25) oval flanges. Counterflanges with 1 GAS included. - Type F : with 1 1/4 (DN32) round flanges. Counterflanges on request. TABLE OF SIZES AND WEIGHTS Dimensions in mm. A 1 B 1 L 1 A 2 L 2 D H Net Weight (Kg) Version with flanges PIN 1 DIN 2534/ISO 75-2 VLR 2B - 3/2 238 213 451 - - 142 19 2 - VLR 2B - 3 238 213 451 - - 142 19 21 - VLR 2B - 4 256 213 469 - - 142 19 23 - VLR 2B - 5 274 213 487 - - 142 19 25 - VLR 2B - 6 296 237 533 - - 16 131 26 - VLR 2B - 7 314 237 551 - - 16 131 33 - VLR 2B - 9 35 237 587 - - 16 131 34 - VLR 2B - 11 386 237 623 - - 16 131 36 - VLR 2B - 13 441 265 76 - - 185 13 37 - VLR 2B - 15 447 265 742 - - 185 13 43 - VLR 2B - 18-265 - 556 821 185 13-49 VLR 2B - 22-265 - 628 893 185 13-61 VLR 2B - 26-315 - 74 119 2 14-63 13

VLR 4 HYDRAULIC PERFORMANCE 5 1 15 2 25 3 Q[lmp gpm] 5 1 15 2 25 3 35 Q[US gpm] 26 24 22 2 18 16 14 12 1 8 6 4 2 4-26 4-24 4-22 4-19 4-16 4-14 4-12 4-1 4-8 4-8/7 4-6 4-5 4-4 4-3 4-2 8 7 6 5 4 3 2 1 H[m] 1,2 2,4 3,6 4,8 6 7,2 8,4 Q[m 3 /h] H[ft] 28 56 84 112 14 Q[l/min] P p [kw],25 75,2 η 5 kw/stage,15 25,1 η[%] NPSH[m] 2 1,5 1,5 NPSH Head and NPHS valid for water with p=1, kg/dm 3 at 2 C of condensity VLR 4 29 rpm 5 Hz ISO 996 - Annex A 14

pump features VLR 4 PUMP PERFORMANCE Motor Power HP kw Voltage In (A) μf. Q L/1 4 6 8 1 12 m 3 /h 2,4 3,6 4,8 6 7,2 Version with oval flanges VLR 4-2 VLR 4-16 VLR 4-2 A M VLR 4-2 A T,5,37 1~23 V 3~23 4 V 2,8 1,7-1, 12,5 18 16 15 12 9 VLR 4-3 A M VLR 4-3 A T,75,55 1~23 V 3~23 4 V 4,2 2,6-1,5 16 27 25 22 18 13 VLR 4-4 A M VLR 4-4 A T 1,75 1~23 V 3~23 4 V 5 3,5-2 25 35 33 29 24 18 VLR 4-5 A M VLR 4-5 A T 1,5 1,1 1~23 V 3~23 4 V 7,9 4,5-2,6 31,5 44 41 36 3 22 VLR 4-6 A M VLR 4-6 A T 1,5 1,1 1~23 V 3~23 4 V 7,9 4,5-2,6 36 53 49 44 36 27 VLR 4-8/7 A M VLR 4-8/7 A T VLR 4-8 A M VLR 4-8 A T 2 1,5 2 1,5 1~23 V 3~23 4 V 1~23 V 3~23 4 V 1,5 6,1-3,5 1,5 6,1-3,5 36 m.c.a. / m.c.w. 62 58 51 43 31 71 66 58 49 35 VLR 4-1 A T 3 2,2 3~23 4 V 8,5-4,9 89 82 73 61 44 VLR 4-12 A T 3 2,2 3~23 4 V 8,5-4,9 16 99 87 73 53 VLR 4-14 A T 4 3 3~23 4 V 11,6-6,7 124 115 12 85 62 VLR 4-16 A T 4 3 3~23 4 V 11,6-6,7 142 131 117 97 71 VLR 4-19 F T 5,5 4 3~23 4 V 14,3-8,3 168 156 138 115 84 VLR 4-22 F T 5,5 4 3~23 4 V 14,3-8,3 195 181 16 134 97 VLR 4-24 F T 7,5 5,5 3~23 69 V 11,3-8,5 213 197 175 146 16 VLR 4-26 F T 7,5 5,5 3~23 69 V 11,3-8,5 23 214 189 158 115 - Type A : with 1 (DN 25) oval flanges. Counterflanges with 1 1 GAS included. - Type F : with 1 1/4 (DN 32) round flanges. Counterflanges on request. TABLE OF SIZES AND WEIGHTS Dimensions in mm. Net Weight (Kg) A 1 B 1 L 1 A 2 L 2 D H VLR 4-2 238 213 451 - - 142 19 2 - Version with flanges PIN 1 DIN 2534/ISO 75-2 VLR 4-3 265 213 478 - - 142 19 21 - VLR 4-4 269 237 533 - - 16 131 23 - VLR 4-5 323 237 56 - - 16 131 25 - VLR 4-6 35 237 587 - - 16 131 26 - VLR 4-8/7 423 265 688 - - 185 13 33 - VLR 4-8 423 265 688 - - 185 13 33 - VLR 4-1 477 265 742 - - 185 13 36 - VLR 4-12 531 265 796 - - 185 13 37 - VLR 4-14 589 315 94 - - 2 14 41 - VLR 4-16 643 315 958 - - 2 14 43 - VLR 4-19 - 335-749 184 2 14-61 VLR 4-22 - 335-83 1165 2 14-63 VLR 4-24 - 385-911 1298 26 185-87 VLR 4-26 - 385-965 135 26 185-89 15

VLR 8 HYDRAULIC PERFORMANCE 1 2 3 4 5 Q[lmp gpm] 1 2 3 4 5 6 Q[US gpm] 24 22 2 18 16 14 12 1 8 6 4 2 8-2 8-18 8-16 8-14 8-12 8-1 8-8 8-6 8-5 8-4 8-3 8-2 7 6 5 4 3 2 1 H[m] 2 4 6 8 1 12 14 16 Q[m 3 /h] H[ft] 5 1 15 2 25 Q[l/min] P p [kw],4 6 η,3 45 kw/stage,2 3,1 15 η[%] NPSH[m] 4,5 3,4 2,2 1,1 NPSH Head and NPHS valid for water with p=1, kg/dm 3 at 2 C of condensity VLR 8 29 rpm 5 Hz ISO 996 - Annex A 16

pump features VLR 8 PUMP PERFORMANCE Motor Power L/1 5 1 15 175 2 HP kw Voltage In (A) μf. Q m 3 /h 3 6 9 1,5 12 Version with oval flanges VLR 8-2 VLR 8-12 VLR 8-2 A M VLR 8-2 A T 1,75 1~23 V 3~23 4 V 5 3,5-1,9 25 21 19 16 14 11 VLR 8-3 A M VLR 8-3 A T 1,5 1,1 1~23 V 3~23 4 V 7,9 4,5-2,6 31,5 31 29 24 21 16 VLR 8-4 A M VLR 8-4 A T 2 1,5 1~23 V 3~23 4 V 1,5 6,1-3,5 36 41 38 32 27 22 VLR 8-5 A T 3 2,2 3~23 4 V 8,5-4,9 52 48 4 34 27 VLR 8-6 A T 3 2,2 3~23 4 V 8,5-4,9 62 58 48 41 33 VLR 8-8 A T 4 3 3~23 4 V 11,6-6,7 82 77 64 55 44 VLR 8-1 A T VLR 8-1 A T 5,5 4 3~23 4 V 3~4 69 V m.c.a. / m.c.w. 14,3-8,3 13 96 8 69 55 VLR 8-12 A T 5,5 4 3~23 4 V 14,3-8,3 124 115 96 82 65 VLR 8-14 F T 7,5 5,5 3~4 69 V 11,3-8,5 144 134 112 96 76 VLR 8-16 F T 7,5 5,5 3~4 69 V 11,3-8,5 165 154 128 11 87 VLR 8-18 F T 1 7,5 3~4 69 V 14,3-8,3 185 173 144 123 98 VLR 8-2 F T 1 7,5 3~4 69 V 14,3-8,3 26 192 16 137 19 - Type A : with 1 1/2 (DN 4) oval flanges. Counterflanges with 1 1/2 GAS thread included. - Type F : with 1 1/2 (DN 4) round flanges. Counterflanges on request. TABLE OF SIZES AND WEIGHTS Dimensions in mm. A 1 B 1 L 1 A 2 L 2 D H D 3 Net Weight (Kg) Version with flanges PIN 1 DIN 2534/ISO 75-2 VLR 8-2 245 237 482 - - 16 131-3 - VLR 8-3 375 237 612 - - 16 131-32 - VLR 8-4 42 265 685 - - 185 13-4 - VLR 8-5 45 265 715 - - 185 13-42 - VLR 8-6 48 265 745 - - 185 13-43 - VLR 8-8 545 315 86 - - 2 14-51 - VLR 8-1 65 335 94 - - 2 14-52 - VLR 8-12 665 335 1 - - 2 14-56 - VLR 8-14 - 385-745 113 26 185 3-85 VLR 8-16 - 385-85 119 26 185 3-86 VLR 8-18 - 385-865 125 26 185 3-9 VLR 8-2 - 385-925 131 26 185 3-91 17

VLR 16 HYDRAULIC PERFORMANCE 1 2 3 4 5 6 7 8 Q[lmp gpm] 1 2 3 4 5 6 7 8 9 1 Q[US gpm] 22 2 16-16 7 18 16-14 6 16 14 12 1 8 6 4 2 16-12 16-1 16-8 16-7 16-6 16-5 16-4 16-3 16-3/2 5 4 3 2 1 H[m] 2 4 6 8 1 12 14 16 18 2 22 24 Q[m 3 /h] H[ft] 1 2 3 4 Q[l/min] P p [kw],9 7 η,6 6 kw/stage,3 5 4 η[%] NPSH[m] 7, 5,3 3,5 1,8 NPSH Head and NPHS valid for water with p=1, kg/dm 3 at 2 C of condensity VLR 16 29 rpm 5 Hz ISO 996 - Annex A 18

pump features VLR 16 PUMP PERFORMANCE Motor Power HP kw Voltage In (A) Q L/1 1 2 25 3 35 m 3 /h 6 12 15 18 21 VLR 16-2 F T 3 2,2 3~23 4 V 8,5-4,9 26 25 23 2 16 VLR 16-3 F T 4 3 3~23 4 V 11,6-6,7 39 37 34 3 24 VLR 16-4 F T 5,5 4 3~23 4 V 14,3-8,3 52 49 46 4 32 VLR 16-5 F T 7,5 5,5 3~4 69 V 11,3-8,5 65 62 57 51 4 VLR 16-6 F T 7,5 5,5 3~4 69 V 11,3-8,5 78 74 69 61 47 VLR 16-7 F T 1 7,5 3~4 69 V 14,3-8,3 91 86 8 71 55 m.c.a. / m.c.w. VLR 16-8 F T 1 7,5 3~4 69 V 14,3-8,3 14 98 92 81 63 VLR 16-1 F T 15 11 3~4 69 V 21-12,1 13 123 115 11 79 VLR 16-12 F T 15 11 3~4 69 V 21-12,1 156 148 137 121 95 VLR 16-14 F T 2 15 3~4 69 V 28-12,6 182 172 16 142 111 VLR 16-16 F T 2 15 3~4 69 V 28-12,6 28 197 183 162 126 Pump with DN5 PN25 DIN 2534/ISO 75-2 round flanges (with 65 mm diameter bore). Counterflanges on request. TABLE OF SIZES AND WEIGHTS Dimensions in mm. A B L D H D 3 Net Weight (Kg) VLR 16-2 F T 46 265 725 185 13 14 52 VLR 16-3 F T 464 315 779 2 14 25 56 VLR 16-4 F T 59 335 844 2 14 25 59 VLR 16-5 F T 575 385 96 26 185 3 82 VLR 16-6 F T 62 385 15 26 185 3 84 VLR 16-7 F T 665 385 15 26 185 3 9 VLR 16-8 F T 71 385 195 26 185 3 92 VLR 16-1 F T 83 495 1325 26 185 35 136 VLR 16-12 F T 92 495 1425 26 185 35 14 VLR 16-14 F T 11 495 155 31 23 35 181 VLR 16-16 F T 11 495 1595 31 23 35 185 19

VLR 32 HYDRAULIC PERFORMANCE 2 4 6 8 1 12 14 16 Q[lmp gpm] 2 4 6 8 1 12 14 16 18 2 Q[US gpm] 26 24 22 2 18 16 14 12 1 8 6 4 2 32-14 32-13 32-12 32-11 32-1 32-9 32-8 32-7 32-6 32-5 32-4 32-3 32-2 32-1 8 7 6 5 4 3 2 1 H[m] 5 1 15 2 25 3 35 4 45 Q[m 3 /h] H[ft] 15 3 45 6 75 Q[l/min] P p [kw] 2 1 η 1,5 67 kw/stage 1 33,5 η[%] NPSH[m] 1 8 5 3 NPSH Head and NPHS valid for water with p=1, kg/dm 3 at 2 C of condensity VLR 32 29 rpm 5 Hz ISO 996 - Annex A 2

pump features VLR 32 PUMP PERFORMANCE Motor Power HP kw Voltage In (A) Q L/1 1 2 3 4 5 m 3 /h,6 1,2 1,8 2,4 3 VLR 32-1 3 2,2 3 ~ 23 4 V 8,65-5 18 16 14 11 7 VLR 32-2 5,5 4 3 ~ 4 69 V 8,6 35 31 27 22 14 VLR 32-3 7,5 5,5 3 ~ 4 69 V 1,9 53 47 41 33 2 VLR 32-4 1 7,5 3 ~ 4 69 V 14,7 71 63 55 44 27 VLR 32-5 15 11 3 ~ 4 69 V 21 89 79 69 55 34 VLR 32-6 15 11 3 ~ 4 69 V 21 16 94 82 66 41 VLR 32-7 2 15 3 ~ 4 69 V 29 124 11 96 77 48 VLR 32-8 2 15 3 ~ 4 69 V 29 142 126 11 88 54 m.c.a. / m.c.w. VLR 32-9 25 18,5 3 ~ 4 69 V 35 159 141 123 99 61 VLR 32-1 3 22 3 ~ 4 69 V 42 177 157 137 11 68 VLR 32-11 3 22 3 ~ 4 69 V 42 195 173 151 121 75 VLR 32-12 4 3 3 ~ 4 69 V 55 212 188 164 132 82 VLR 32-13 4 3 3 ~ 4 69 V 55 23 24 178 143 88 VLR 32-14 4 3 3 ~ 4 69 V 55 248 22 192 154 95 Pump with DN5 PN25 DIN 2534/ISO 75-2 round flanges. Counterflanges on request. TABLE OF SIZES AND WEIGHTS Dimensions in mm. A B L D Net Weight (Kg) VLR 32-1 58 85 185 145 78 VLR 32-2 65 95 21 155 93,5 VLR 32-3 77 116 26 2 114 VLR 32-4 84 123 26 2 121 VLR 32-5 91 137 26 215 153 VLR 32-6 98 144 26 215 157,5 VLR 32-7 15 151 26 215 166,5 VLR 32-8 112 158 26 215 177,5 VLR 32-9 119 165 32 245 2 VLR 32-1 126 18 32 245 218 VLR 32-11 133 187 32 245 222,5 VLR 32-12 14 198 32 245 236 VLR 32-13 148 212 36 275 269 VLR 32-14 155 219 36 275 28 21

VLR 46 HYDRAULIC PERFORMANCE 5 1 15 2 5 1 15 2 25 Q[lmp gpm] Q[US gpm] H[m] 34 32 3 28 26 24 22 2 18 16 14 12 1 8 6 4 2 46-13/2 46-12 46-12/2 46-11 46-11/2 46-1 46-1/2 46-9 46-9/2 46-8 46-8/2 46-7 46-7/2 46-6 46-6/2 46-5 46-5/2 46-4 46-4/2 46-3 46-3/2 46-2 46-2/2 46-1 46-1/1 5 1 15 2 25 3 35 4 45 5 55 6 65 Q[m 3 /h] 1 9 8 7 6 5 4 3 2 1 H[ft] 1 2 3 4 5 6 7 8 9 1 Q[l/min] P p [kw] 4 9 kw/stage η2 3 73 2 1 η1 57 4 η[%] NPSH[m] 5 4 3 2 1 NPSH Head and NPHS valid for water with p=1, kg/dm 3 at 2 C of condensity VLR 46 29 rpm 5 Hz ISO 996 - Annex A 22

pump features VLR 46 PUMP PERFORMANCE Motor Power HP kw Voltage In (A) Q 23 L/1 367 417 5 583 667 75 9 1 m 3 /h 22 25 3 35 4 45 54 6 VLR 46-1/1 4 3 3~4 69 5 19 19 18 17 15 13 9 5 VLR 46-1 5,5 4 3~4 69 8,6 24 24 23 21 2 18 14 11 VLR 46-2/2 7,5 5,5 3~4 69 1,9 4 39 38 36 33 29 21 14 VLR 46-2 1 7,5 3~4 69 14,7 49 48 46 44 42 39 31 25 VLR 46-3/2 15 11 3~4 69 21 65 64 62 6 56 52 4 31 VLR 46-3 15 11 3~4 69 21 74 73 71 68 65 6 5 41 VLR 46-4/2 2 15 3~4 69 29 91 9 87 83 79 73 58 46 VLR 46-4 2 15 3~4 69 29 1 98 96 92 87 82 68 56 VLR 46-5/2 25 18,5 3~4 69 35 115 113 11 16 1 93 75 6 VLR 46-5 25 18,5 3~4 69 35 125 123 12 116 11 13 86 72 VLR 46-6/2 3 22 3~4 69 42 139 138 134 129 122 113 92 73 VLR 46-6 3 22 3~4 69 42 15 148 144 139 132 124 14 86 VLR 46-7/2 4 3 3~4 69 55 165 163 158 152 144 134 11 89 VLR 46-7 4 3 3~4 69 55 176 173 168 162 155 145 122 11 VLR 46-8/2 4 3 3~4 69 55 19 188 182 176 166 155 127 13 VLR 46-8 4 3 3~4 69 55 199 196 191 184 175 164 137 113 VLR 46-9/2 4 3 3~4 69 55 215 212 26 198 187 174 143 116 VLR 46-9 5 37 3~4 69 65 225 222 217 29 199 187 157 13 VLR 46-1/2 5 37 3~4 69 65 241 238 232 223 212 198 164 134 VLR 46-1 5 37 3~4 69 65 25 247 241 232 221 28 174 145 VLR 46-11/2 6 45 3~4 69 8 267 264 258 249 237 222 184 151 VLR 46-11 6 45 3~4 69 8 276 273 266 257 245 23 194 161 VLR 46-12/2 6 45 3~4 69 8 293 289 282 272 259 243 22 166 VLR 46-12 6 45 3~4 69 8 31 297 29 28 267 25 21 175 VLR 46-13/2 6 45 3~4 69 8 316 312 34 292 277 259 214 175 Pump with DN8 PN16 (VLR46-1/1, VLR 46-5); PN25 from VLR 46-6/2 to 46-9; PN 4 from VLR 46-1 TO 46-13/2 round flanges. Counterflanges on request. TABLE OF SIZES AND WEIGHTS Dimensions in mm. L 1 L 2 D 1 D 2 M m.c.a. / m.c.w. Net Weight (Kg) VLR 46-1/1 529 298 174 164 134 79 VLR 46-1 529 319 197 164 154 84,5 VLR 46-2/2 624 375 214 3 168 14 VLR 46-2 624 367 356 3 191 122 VLR 46-3/2 734 428 256 35 191 144 VLR 46-3 734 428 256 35 191 144 VLR 46-4/2 89 494 313 35 24 18 VLR 46-4 89 494 313 35 24 18 VLR 46-5/2 884 494 313 35 24 193 VLR 46-5 884 494 313 35 24 193 VLR 46-6/2 959 494 313 35 24 28 VLR 46-6 959 494 313 35 24 28 VLR 46-7/2 134 613 354 4 278 23 VLR 46-7 134 613 354 4 278 23 VLR 46-8/2 119 613 354 4 278 234 VLR 46-8 119 613 354 4 278 234 VLR 46-9/2 1184 613 354 4 278 238 VLR 46-9 1184 613 354 4 278 238 VLR 46-1/2 1259 613 354 4 278 248 VLR 46-1 1259 613 354 4 278 257 VLR 46-11/2 1334 71 411 45 298 257 VLR 46-11 1334 71 411 45 298 345 VLR 46-12/2 149 71 411 45 298 345 VLR 46-12 149 71 411 45 298 35 VLR 46-13/2 1484 71 411 45 298 354

VLR 66 HYDRAULIC PERFORMANCE 5 1 15 2 25 3 Q[lmp gpm] 5 1 15 2 25 3 35 Q[US gpm] 26 24 22 2 18 16 14 12 1 8 6 4 2 66-8 66-8/1 66-8/2 66-7 66-7/1 66-7/2 66-6 66-6/1 66-6/2 66-5 66-5/1 66-5/2 66-4 66-4/1 66-4/2 66-3 66-3/1 66-3/2 66-2 66-2/1 66-2/2 66-1 66-1/1 8 7 6 5 4 3 2 1 H[m] H[ft] 5 1 15 2 25 3 35 4 45 5 55 6 65 7 75 8 85 9 2 4 6 8 1 12 14 Q[m 3 /h] Q[l/min] P p [kw] 8 9 6 kw/stage 4 2 η1 η2 73 57 4 η[%] NPSH[m] 1 8 5 3 NPSH Head and NPHS valid for water with p=1, kg/dm 3 at 2 C of condensity VLR 66 29 rpm 5 Hz ISO 996 - Annex A 24

pump features VLR 66 PUMP PERFORMANCE Motor Power Voltage In (A) Q L/1 5 6 7 75 9 1 12 13 1417 HP kw m 3 /h 3 36 42 45 54 6 72 78 85 VLR 66-1/1 5,5 4 3~4 69 8,6 21 21 2 19 18 17 13 11 8 VLR 66-1 7,5 5,5 3~4 69 1,9 26 25 24 23 22 21 18 16 14 VLR 66-2/2 1 7,5 3~4 69 14,7 43 41 4 39 36 33 26 22 16 VLR 66-2/1 15 11 3~4 69 21 5 48 47 46 43 41 35 31 26 VLR 66-2 15 11 3~4 69 21 56 54 53 52 49 47 42 39 35 VLR 66-3/2 2 15 3~4 69 29 72 7 67 66 62 58 49 43 35 VLR 66-3/1 2 15 3~4 69 29 78 76 74 72 68 65 56 51 44 VLR 66-3 25 18,5 3~4 69 35 85 83 81 79 75 72 64 6 54 VLR 66-4/2 25 18,5 3~4 69 35 1 97 94 92 86 82 7 63 53 VLR 66-4/1 3 22 3~4 69 42 16 13 1 99 93 89 78 71 62 VLR 66-4 3 22 3~4 69 42 113 11 17 15 1 96 86 79 71 VLR 66-5/2 4 3 3~4 69 55 128 124 12 118 111 16 92 83 7 VLR 66-5/1 4 3 3~4 69 55 134 131 127 125 118 112 99 91 8 VLR 66-5 4 3 3~4 69 55 14 137 133 131 125 119 17 99 89 VLR 66-6/2 4 3 3~4 69 55 156 152 147 144 136 129 113 13 88 VLR 66-6/1 4 3 3~4 69 55 162 158 153 151 143 136 121 111 97 VLR 66-6 5 37 3~4 69 65 169 164 16 158 15 143 128 119 16 VLR 66-7/2 5 37 3~4 69 65 184 179 174 171 161 153 134 122 16 VLR 66-7/1 5 37 3~4 69 65 19 185 18 177 168 16 142 131 115 VLR 66-7 6 45 3~4 69 8 197 192 187 184 174 167 15 139 124 VLR 66-8/2 6 45 3~4 69 8 212 26 2 197 186 177 156 142 124 VLR 66-8/1 6 45 3~4 69 8 218 213 27 24 193 184 163 15 133 VLR 66-8 6 45 3~4 69 8 225 219 213 21 199 191 171 159 142 Flange DN 1 PN 16 from VLR 66-1/1 to 66-8. PN 25 from VLR 66-6 to 66-8. Counterflanges on request. TABLE OF SIZES AND WEIGHTS Dimensions in mm. Net Weight L 1 L 2 D 1 D 2 M (Kg) VLR 66-1/1 554 319 197 164 154 92,5 VLR 66-1 574 375 214 3 168 11 VLR 66-2/2 664 367 256 3 191 133 VLR 66-2/1 699 428 256 3 191 151 VLR 66-2 699 428 256 35 191 151 VLR 66-3/2 789 494 313 35 24 188 VLR 66-3/1 789 494 313 35 24 188 VLR 66-3 789 494 313 35 24 197 VLR 66-4/2 879 494 313 35 24 23 VLR 66-4/1 879 494 313 35 24 214 VLR 66-4 879 494 313 35 24 214 VLR 66-5/2 969 613 354 4 278 237 VLR 66-5/1 969 613 354 4 278 237 VLR 66-5 969 613 354 4 278 245 VLR 66-6/2 159 613 354 4 278 245 VLR 66-6/1 159 613 354 4 278 255 VLR 66-6 159 613 354 4 278 255 VLR 66-7/2 1149 613 354 4 278 261 VLR 66-7/1 1149 613 354 4 278 261 VLR 66-7 1149 71 411 45 298 341 VLR 66-8/2 1239 71 411 45 298 346 VLR 66-8/1 1239 71 411 45 298 346 VLR 66-8 1239 71 411 45 298 346 m.c.a. / m.c.w. 25

VLR 92 HYDRAULIC PERFORMANCE 1 2 3 4 Q[lmp gpm] 1 2 3 4 5 Q[US gpm] 22 2 92-7/2 92-6 7 18 16 14 12 1 8 6 4 2 92-6/2 92-5 92-5/2 92-4 92-4/2 92-3 92-3/2 92-2 92-2/2 92-1 92-1/1 6 5 4 3 2 1 H[m] 2 4 6 8 1 12 Q[m 3 /h] H[ft] 5 1 15 2 Q[l/min] P p [kw] 8 9 kw/stage 6 η1 73 η2 4 57 2 4 η[%] NPSH[m] 1 8 5 3 NPSH Head and NPHS valid for water with p=1, kg/dm 3 at 2 C of condensity VLR 92 29 rpm 5 Hz ISO 996 - Annex A 26

pump features VLR 92 PUMP PERFORMANCE Motor Power HP kw Voltage In (A) Q L/1 75 9 1 12 13 1417 16 18 2 m 3 /h 45 54 6 72 78 85 96 18 12 VLR 92-1/1 7,5 5,5 3~4 69 1,9 22 22 21 19 19 17 15 12 8 VLR 92-1 1 7,5 3~4 69 14,7 29 27 26 24 23 22 2 18 14 VLR 92-2/2 15 11 3~4 69 21 45 44 43 4 38 36 31 25 17 VLR 92-2 2 15 3~4 69 29 58 55 53 5 48 45 41 36 3 VLR 92-3/2 25 18,5 3~4 69 35 74 72 7 65 62 59 52 44 33 VLR 92-3 3 22 3~4 69 42 88 84 81 76 73 69 63 56 46 m.c.a. / m.c.w. VLR 92-4/2 4 3 3~4 69 55 14 1 97 9 87 82 74 63 49 VLR 92-4 4 3 3~4 69 55 117 112 18 11 97 92 85 75 63 VLR 92-5/2 5 37 3~4 69 65 122 128 124 116 111 15 95 81 65 VLR 92-5 5 37 3~4 69 65 146 14 135 126 121 115 16 94 78 VLR 92-6/2 6 45 3~4 69 8 163 156 152 141 135 129 117 11 81 VLR 92-6 6 45 3~4 69 8 176 168 163 151 146 139 127 113 94 VLR 92-7/2 6 45 3~4 69 8 192 184 179 167 16 152 138 12 97 Pump with DN1 PN16 from VLR 92-1/2 to 92-4. PN25 from VLR 92-5/2 to 92-7/2. Counterflanges on request. TABLE OF SIZES AND WEIGHTS Dimensions in mm. L 1 L 2 D 1 D 2 M Net Weight (Kg) VLR 92-1/1 574 375 214 3 168 19 VLR 92-1 574 367 256 3 191 127 VLR 92-2/2 699 428 256 35 191 15 VLR 92-2 699 494 313 35 24 182 VLR 92-3/2 789 494 313 35 24 197 VLR 92-3 789 494 313 35 24 28 VLR 92-4/2 879 613 354 4 278 232 VLR 92-4 879 613 354 4 278 232 VLR 92-5/2 969 613 354 4 278 25 VLR 92-5 969 613 354 4 278 25 VLR 92-6/2 159 71 411 45 298 335 VLR 92-6 159 71 411 45 298 335 VLR 92-7/2 1149 71 411 45 298 34 27

ACCESSOIRES FOR VLR/VLRI/VLR CIRCULAR FLANGES CODE DESCRIPTION Material Ext D inter. S N Holes D holes F Filett. hole B a sald. PN STANDARD D386KKK 14 1 4 18 1 1/4-16 UNI EN 192-1 B798KKK 15 11 4 18 - DN4 16 UNI EN 192-1 B797KKK F 15 11 4 18 1 1/2-16 UNI EN 192-1 ZB9189 165 125 4 18 - DN5 16 UNI EN 192-1 B75KKK STEEL 165 125 4 18 2-16 UNI EN 192-1 B B751KKK 165 125 4 18 2 1/2-16 N/A ZB9192 22 18 8 18 - DN1 16 UNI EN 192-1 B7698KKK 185 145 8 18 - DN65 25 UNI EN 192-1 ZB9235 D 235 19 8 22 - DN1 25 UNI EN 192-1 ZA846 STAINLESS 14 99,2 4 2 1 1/4 DN32 16 N/A ZB9212 Kit of two circular flanges including bolts and gaskets STEEL 15 11 4 2 1 1/2 DN4 16 N/A ZB9213 AISI 316 165 126 4 2 2 DN5 16 N/A OVAL FLANGES S CODE DESCRIPTION Material ZC127 S Oval flange single F est. D est. A inter S Ø Holes F hole B threaded CAST IRON 95 68 65 11 1 ZC129 CAST IRON 95 68 65 11 1 1/4 B A ZC128 CAST IRON 128 75 1 14 1 1/2 D ZA856 VICTAULIC JOINTS Kit of two oval flanges including bolts 1 1/4 and gaskets STAINLESS STEEL embossed AISI 316 CODE DESCRIPTION Material 95 68 65 11 1 1/4 Dimension Y Z CONNECTION ZA92 68 117 45 CAST IRON ZA93 87 133 48 VICTAULIC joint 1 1/4 42,2 2 6,3 SELECTION GUIDE ACCESSORY KIT WITH 2 CIRCULAR FLANGES OVAL FLANGES Port size 1¼ 1½ DN4 2 2½ DN 5 Notes PN 16 PN 16 PN 16 PN 16 - PN 25 PN 25 PN 16 PN 25 PN 16 PN 16 PN 16 DN 65 DN 1 DN 1 DN 32 DN 4 DN 5 1 1¼ 1½ 1¼ CAST IRON CAST IRON CAST IRON CAST IRON TYPE CODE D386KKK B797KKK B798KKK B75KKK B751KKK ZB9189 B7698KKK ZB9192 ZB9235 ZA846 ZB9212 ZB9213 * ZC127 * ZC129 * ZC128 ZA856 VLR 2B FLANGE A VLR 2B FLANGE F VLR 4 FLANGE A VLR 4 FLANGE F VLR 8 FLANGE A VLR 8 FLANGE F VLR 16 FLANGE F VLR 32 FLANGE F VLR 66 FLANGE F 66-5 VLR 66 FLANGE F 66-6 VLR 92 FLANGE F 92-4 VLR 92 FLANGE F 92-5 VLRI/ 2B/4 FLANGE A VLRI/ 2B/4 FLANGE F VLRI/ 8 FLANGE A VLRI/ 16 FLANGE F * These codes refer to a single flange without screws or gaskets Standard component Optional component 48