Product Catalog NEK 606/BFOU/RFOU/BU/RU. Marine, oil, gas and offshore cables
|
|
- Ἀδελφός Ρέντης
- 8 χρόνια πριν
- Προβολές:
Transcript
1 Product Catalog NEK 606/BFOU/RFOU/BU/RU Marine, oil, gas and offshore cables
2 Offshore Cables Basic Program IEC / NEK TS 606 Index NEK 606 Cable types... 3 Halogen-free, mud resistant instrumentation cable RFOU(i) 150/250(300)V, S1/S Halogen-free, mud resistant instrumentation cable RFOU(c) 150/250(300)V, S2/S Halogen-free, mud resistant, fire resistant instrumentation cable BFOU(i) 150/250(300)V, S3/S Halogen-free, mud resistant, fire resistant instrumentation cable BFOU(c) 150/250(300)V, S4/S Halogen-free, unarmoured mud resistant instrumentation cable RU(i) 150/250(300)V, S Halogen-free, unarmoured mud resistant instrumentation cable RU(c) 150/250(300)V, S Halogen-free, fire resistant, unarmoured, mud resistant instrumentation cable BU(i) 150/250(300)V, S Halogen-free, fire resistant, unarmoured, mud resistant instrumentation cable BU(c) 150/250(300)V, S Halogen-free, mud resistant power cable RFOU 0,6/1(1,2)kV, P1/P Halogen-free, mud resistant power cable RFOU 0,6/1(1,2)kV, P1/P8, large single core cables Halogen-free, mud resistant power cable RFOU 0,6/1(1,2)kV, P1/P8, double braided Halogen-free, mud resistant MV power cable, RFOU 3,6/6(7,2)kV, P2/P Halogen-free, mud resistant MV power cable, RFOU 6/10(12)kV, P3/P Halogen-free, mud resistant MV power cable, RFOU 8,7/15(17,5)kV, P4/P Halogen-free, mud resistant MV power cable, RFOU 12/20(24)kV, P19/P Halogen-free, mud resistant MV power cable, RFOU 18/30(36)kV, P20/P Halogen-free, mud resistant, fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P Halogen-free, mud resistant, fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12, double braided Halogen-free, mud resistant, fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12, large single core cables Halogen-free, mud resistant insulated conductor UX 1000V, P Halogen-free, fire resistant, unarmoured, mud resistant power cable, BU 0,6/1(1,2)kV, P Halogen-free, unarmoured, mud resistant power cable, RU 0,6/1(1,2)kV, P Cable for Variable Frequency Drives (VFD s), RFOU-VFD 0,6/1(1,8/3)kV with flexible conductors class 5 and separate earth cores Cable for Variable Frequency Drives (VFD s), RFOU-VFD 0,6/1(1,8/3)kV with stranded conductors class 2 and tinned copper wire braid as earth Fire resistant optical fibre cable, QFCI-I/O/RM-JM/-, F Fire resistant optical fibre cable, QFCI-I/O/RM/C-JM/-, MUD PROTECTED (F5) Flame retardant optical fibre cable, AICI-I/O/RM-W, F Flame retardant optical fibre cable, AICI-I/O/RM/C-W, MUD PROTECTED Optical fibre data sheet ICS IE ToughCat 5e S/FTP Installation cable for tougher environments ICS IE ToughCat 7 S/FTP Installation cable for tougher environments ICS IE ToughCat 7S* S/FTP Installation cable for tougher environments ICS IE ToughCat 5e MUD Protected S/FTP Installation cable for tougher environments ICS IE ToughCat 7 MUD Protected S/FTP Installation cable for tougher environments ICS IE ToughCat 7S* MUD Protected S/FTP Installation cable for tougher environments ARCTIC GRADE instrumentation cable RFOU(i) 150/250(300)V, S1/S ARCTIC GRADE instrumentation cable RFOU(c) 150/250(300)V, S2/S ARCTIC GRADE Fire resistant, instrumentation cable BFOU(i) 150/250(300)V, S3/S ARCTIC GRADE Fire resistant, instrumentation cable BFOU(c) 150/250(300)V, S4/S ARCTIC GRADE power cable RFOU 0,6/1(1,2)kV, P1/P ARCTIC GRADE power cable RFOU 0,6/1(1,2)kV, P1/P8, large single core cables ARCTIC GRADE power cable RFOU 0,6/1(1,2)kV, P1/P8, double braided Subject to change without prior notice Page 1 of 212
3 ARCTIC GRADE Fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P ARCTIC GRADE Fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12, double braided extended Fire Resistant, instrumentation cable BFOU-XFR(i) 150/250(300)V extended Fire Resistant, instrumentation cable BFOU-XFR(c) 150/250(300)V extended Fire Resistant, instrumentation cable BFCU-XFR(i) 150/250(300)V, steel wire braided extended Fire Resistant, instrumentation cable BFCU-XFR(c) 150/250(300)V, steel wire braided Hydraulic and Turbine oils resistant, instrumentation cable BFOV(i) 150/250(300)V Hydraulic and Turbine oils resistant, instrumentation cable BFOV(c) 150/250(300)V Hydraulic and Turbine oils resistant, power cable BFOV 0,6/1(1,2)kV Hydro Carbon Fire Resistant Cables Hydro Carbon Fire resistant instrument cable BFOU-HCF(i) 150/250(300)V, S Hydro Carbon Fire resistant instrument cable BFOU-HCF(c) 150/250(300)V, S Hydro Carbon Fire resistant power cable BFOU-HCF 0,6/1(1,2)kV, P Hydro Carbon Fire resistant MV power cable RFOU-HCF 6/10(12)kV, P Hydro Carbon Fire resistant MV power cable RFOU-HCF 8,7/15(17,5)kV, P Approvals Standards and tests Definition of terms Fire, flame, smoke and corrosion test methods Installation recoendations Electrical data Material properties SHF1 versus SHF Core colours for cables according to NEK TS Drum capacity in meters Code designation for cables Subject to change without prior notice Page 2 of 212
4 NEK 606 Cable types List of all the cable types listed in NEK 606 : NEK 2004 Third Edition NEK TS 606 Code NEK TS 606 Description Draka Norsk Kabel s cable type Power cables LV and MV P1 P1 / P8 RFOU / TFOU 0,6/1 kv RFOU 0,6/1 kv P2 P2 / P9 RFOU / TFOU 3,6/6(7,2) kv RFOU 3,676(7,2) kv P3 P3/P10 RFOU / TFOU 6/10(12) kv RFOU 6/10(12) kv P4 P4/P11 RFOU / TFOU 8,7/15(17,5) kv RFOU 8,7/15(17,5) kv P5 P5/P12 BFOU 0,6/1 kv BFOU 0,6/1 kv P6 P6/P13 BFOU 3,6/6(7,2) kv - P7 P7/P14 BFOU 6/10(12) kv - P15 UX 0,6/1 kv UX 0,6/1 kv P16 IFLI 250V IFLI 250V P17 BU 0,6/1 kv BU 0,6/1 kv P18 RU 0,6/1 kv RU 0,6/1 kv P19 P19/P21 RFOU / TFOU 12/20(24) kv RFOU 12/20(24) kv P20 P20/P22 RFOU / TFOU 18/30(36) kv RFOU 18/30(36) kv P30 RFOU-HCF / TFOU-HCF 6/10(12) kv RFOU-HCF 6/10(12) kv P31 RFOU-HCF / TFOU-HCF 8,7/15(17,5) kv RFOU-HCF 8,7/15(17,5) kv P32 RFOU-HCF / TFOU-HCF 12/20(24) kv RFOU-HCF 12/20(24) kv P33 RFOU-HCF / TFOU-HCF 18/30(36) kv RFOU-HCF 18/30(36) kv P34 BFOU-HCF 0,6/1 kv BFOU-HCF 0,6/1 kv Instrumentation and telecounication cables S1 S1/S5 RFOU(i) 250V RFOU(i) 250V S2 S2/S6 RFOU(c) 250V RFOU(c) 250V S3 S3/S7 BFOU(i) 250V BFOU(i) 250V S4 S4/S8 BFOU(c) 250V BFOU(c) 250V S9 IYXI(c) 60V - S10 IYOI(c) 60V - S11 RU(i) 250V RU(i) 250V S12 RU(c) 250V RU(c) 250V S13 BU(i) 250V BU(i) 250V S14 BU(c) 250V BU(c) 250V S15 BFOU-HCF(i) 250V BFOU-HCF(i) 250V S16 BFOU-HCF(c) 250V BFOU-HCF(c) 250V Optical Fibre Cable F1 QFCI QFCI F4 QFCI-HCF QFCI-HCF F5 QFCB QFCI- MUD F6 AICI AICI Cable types P8 P14, P21 P22, S5 S8 and F5 are to be mud resistant as per NEK TS 606 Subject to change without prior notice Page 3 of 212
5 Halogen-free, mud resistant instrumentation cable RFOU(i) 150/250(300)V, S1/S5 Flame retardant halogen-free instrumentation cable. Mud resistant RFOU(i) 150/250(300)V EPR/EPR/TCWB/EVA NEK TS 606 CodeS1/S5 Operating temperature : 90 C Operating Voltage : 150/250(300)V Standards applied Application Fixed installation for instrumentation, counication, Control and alarm systems in both EX (Zone 0, 1 & 2)- and safe areas. Meets the mud resistant requirements in NEK TS 606:2009. IEC ( ) IEC class 2 IEC IEC IEC IEC IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation R EP-rubber, IEC (EPR) Pair / Triple / Quad twisting Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by ed tape or by s printed directly on the insulated conductors. Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with a PETP tape. Lay up / Shielding Inner covering F Flame retardant and halogen-free thermoset compound Tape over inner PET tape covering Armour/screen O Tinned annealed copper wire braid Tape over PET tape armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) E.g. "meter" "year" DRAKA 01 RFOU(i) 250V S1/S5 4 PAIR 0,75 2 IEC IEC DRAKA 01 = Draka Norsk Kabel, Grey or Blue Subject to change without prior notice Page 4 of 212
6 Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey Range and dimensions Number of elements No of cores in element core, ² Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Mechanical cross of the braid, ² Thickness Outer Sheath, outer sheath, Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) ± ± ± ± ± ± ± ± ± ± ± ± ± 19.5 ± ± 19.5 ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± 16.5 ± ± 16.5 ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± Subject to change without prior notice Page 5 of 212
7 Number of elements No of cores in element core, ² Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Mechanical cross of the braid, ² Thickness Outer Sheath, outer sheath, Weight of Cable Approx. (Kg/Km) ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± 17.5 ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± 17.5 ± ± 17.5 ± ± ± Copper content Approx. (kg/km) Electrical values instrumentation cables Type Capacitance, approx. (nf/km) Inductance, approx, (mh/km) Resistance at 20 C, max. (Ohm/km) L/R ratio, (microh/ohm) Shielded pair 0,75 ² 110 0,67 26,3 12,7 Shielded triple 0,75 ² 110 0,67 26,3 12,7 Shielded pair 1,5 ² 125 0,63 12,9 24,4 Shielded triple 1,5 ² 125 0,63 12,9 24,4 Shielded pair 2,5 ² 145 0,59 8,02 36,8 Shielded triple 2,5 ² 145 0,59 8,02 36,8 Ordering information New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No RFOU(I) 1PAIR 0.75² S1/S5 GREY Yes RFOU(I) 1PAIR 0.75² S1/S5 BLUE Yes RFOU(I) 2PAIR 0.75² S1/S5 GREY Yes RFOU(I) 2PAIR 0.75² S1/S5 BLUE RFOU(I) 4PAIR 0.75² S1/S5 GREY Yes RFOU(I) 4PAIR 0.75² S1/S5 BLUE RFOU(I) 8PAIR 0.75² S1/S5 GREY Yes RFOU(I) 8PAIR 0.75² S1/S5 BLUE RFOU(I) 12PAIR 0.75² S1/S5 GREY RFOU(I) 12PAIR 0.75² S1/S5 BLUE RFOU(I) 16PAIR 0.75² S1/S5 GREY RFOU(I) 16PAIR 0.75² S1/S5 BLUE RFOU(I) 19PAIR 0.75² S1/S5 GREY RFOU(I) 19PAIR 0.75² S1/S5 BLUE RFOU(I) 24PAIR 0.75² S1/S5 GREY RFOU(I) 24PAIR 0.75² S1/S5 BLUE Subject to change without prior notice Page 6 of 212
8 New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No RFOU(I) 1TRIP 0.75² S1/S5 GREY Yes RFOU(I) 1TRIP 0.75² S1/S5 BLUE RFOU(I) 2TRIP 0.75² S1/S5 GREY RFOU(I) 2TRIP 0.75² S1/S5 BLUE RFOU(I) 4TRIP 0.75² S1/S5 GREY RFOU(I) 4TRIP 0.75² S1/S5 BLUE RFOU(I) 8TRIP 0.75² S1/S5 GREY RFOU(I) 8TRIP 0.75² S1/S5 BLUE RFOU(I) 12TRIP 0.75² S1/S5 GREY RFOU(I) 12TRIP 0.75² S1/S5 BLUE RFOU(I) 16TRIP 0.75² S1/S5 GREY RFOU(I) 16TRIP 0.75² S1/S5 BLUE RFOU(I) 19TRIP 0.75² S1/S5 GREY RFOU(I) 24TRIP 0.75² S1/S5 GREY RFOU(I) 24TRIP 0.75² S1/S5 BLUE RFOU(I) 1PAIR ² S1/S5 GREY Yes RFOU(I) 1PAIR ² S1/S5 BLUE Yes RFOU(I) 2PAIR ² S1/S5 GREY Yes RFOU(I) 2PAIR ² S1/S5 BLUE RFOU(I) 4PAIR ² S1/S5 GREY Yes RFOU(I) 4PAIR ² S1/S5 BLUE RFOU(I) 8PAIR ² S1/S5 GREY Yes RFOU(I) 8PAIR ² S1/S5 BLUE Yes RFOU(I) 12PAIR ² S1/S5 GREY Yes RFOU(I) 12PAIR ² S1/S5 BLUE RFOU(I) 16PAIR ² S1/S5 GREY Yes RFOU(I) 16PAIR ² S1/S5 BLUE RFOU(I) 19PAIR ² S1/S5 GREY RFOU(I) 19PAIR ² S1/S5 BLUE RFOU(I) 24PAIR ² S1/S5 GREY RFOU(I) 24PAIR ² S1/S5 BLUE RFOU(I) 32PAIR ² S1/S5 GREY RFOU(I) 1TRIP ² S1/S5 GREY RFOU(I) 1TRIP ² S1/S5 BLUE RFOU(I) 2TRIP ² S1/S5 GREY RFOU(I) 4TRIP ² S1/S5 GREY RFOU(I) 4TRIP ² S1/S5 BLUE RFOU(I) 8TRIP ² S1/S5 GREY RFOU(I) 8TRIP ² S1/S5 BLUE RFOU(I) 12TRIP ² S1/S5 GREY RFOU(I) 12TRIP ² S1/S5 BLUE RFOU(I) 16TRIP ² S1/S5 GREY RFOU(I) 16TRIP ² S1/S5 BLUE RFOU(I) 24TRIP ² S1/S5 GREY RFOU(I) 24TRIP ² S1/S5 BLUE RFOU(I) 1PAIR 2.5² S1/S5 GREY RFOU(I) 2PAIR 2.5² S1/S5 GREY RFOU(I) 2PAIR 2.5² S1/S5 BLUE RFOU(I) 4PAIR 2.5² S1/S5 GREY Installation recoendations Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation Installation Installed Installation Temperature 8 x D 6 x D 50 N /² -20 C Subject to change without prior notice Page 7 of 212
9 Halogen-free, mud resistant instrumentation cable RFOU(c) 150/250(300)V, S2/S6 Flame retardant halogen-free instrumentation cable. Mud resistant RFOU(c) 150/250(300)V EPR/EPR/TCWB/EVA NEK TS 606 CodeS2/S6 Operating temperature : 90 C Operating Voltage : 150/250(300)V Standards applied Application Fixed installation for instrumentation, counication, Control and alarm systems in both EX (Zone 0, 1 & 2)- and safe areas. Meets the mud resistant requirements in NEK TS 606:2009. IEC ( ) IEC class 2 IEC IEC IEC IEC IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation R EP-rubber, IEC (EPR) Pair / Triple / Quad twisting Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire.pairs/triples are identified by ed tape or by s printed directly on the insulated conductors. Inner covering F Flame retardant and halogen-free thermoset compound Tape over inner PET tape covering Armour/screen O Tinned annealed copper wire braid Tape over armour/screen PET tape Outer sheath Marking text Manufacturing unit Outer sheath colour U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) E.g. "meter" "year" DRAKA 01 RFOU(c) 250V S2/S6 8 PAIR 0,75 2 IEC IEC DRAKA 01 = Draka Norsk Kabel, Grey or Blue Subject to change without prior notice Page 8 of 212
10 Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey Range and dimensions Number No of of cores in elements element core, ² Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Mechanical cross of the braid, ² Thickness Outer Sheath, outer sheath, Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± 16.5 ± ± 16.5 ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± 19.5 ± ± ± ± ± ± ± ± ± ± ± ± ± Subject to change without prior notice Page 9 of 212
11 Number No of of cores in elements element core, ² Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Mechanical cross of the braid, ² Thickness Outer Sheath, outer sheath, Weight of Cable Approx. (Kg/Km) ± ± Copper content Approx. (kg/km) ± ± ± ± ± 19.5 ± 19.5 ± 3 ± Electrical values instrumentation cables Type Capacitance, approx. (nf/km) Inductance, approx, (mh/km) Resistance at 20 C, max. (Ohm/km) L/R ratio, (microh/ohm) Unshielded pair 0,75 ² 100 0,67 26,3 12,7 Unshielded triple 0,75 ² 100 0,67 26,3 12,7 Unshielded pair 1,5 ² 110 0,63 12,9 24,4 Unshielded triple 1,5 ² 110 0,63 12,9 24,4 Unshielded pair 2,5 ² 125 0,59 8,02 36,8 Unshielded triple 2,5 ² 125 0,59 8,02 36,8 Ordering information New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No RFOU(C) 2PAIR 0.75² S2/S6 GREY Yes RFOU(C) 2PAIR 0.75² S2/S6 BLUE RFOU(C) 4PAIR 0.75² S2/S6 GREY Yes RFOU(C) 4PAIR 0.75² S2/S6 BLUE RFOU(C) 8PAIR 0.75² S2/S6 GREY RFOU(C) 8PAIR 0.75² S2/S6 BLUE RFOU(C) 12PAIR 0.75² S2/S6 GREY RFOU(C) 12PAIR 0.75² S2/S6 BLUE RFOU(C) 16PAIR 0.75² S2/S6 GREY RFOU(C) 16PAIR 0.75² S2/S6 BLUE RFOU(C) 19PAIR 0.75² S2/S6 GREY RFOU(C) 24PAIR 0.75² S2/S6 GREY RFOU(C) 24PAIR 0.75² S2/S6 BLUE RFOU(C) 2TRIP 0.75² S2/S6 GREY RFOU(C) 2TRIP 0.75² S2/S6 BLUE RFOU(C) 4TRIP 0.75² S2/S6 GREY RFOU(C) 4TRIP 0.75² S2/S6 BLUE RFOU(C) 8TRIP 0.75² S2/S6 GREY RFOU(C) 8TRIP 0.75² S2/S6 BLUE RFOU(C) 12TRIP 0.75² S2/S6 GREY RFOU(C) 12TRIP 0.75² S2/S6 BLUE RFOU(C) 16TRIP 0.75² S2/S6 GREY RFOU(C) 24TRIP 0.75² S2/S6 GREY RFOU(C) 24TRIP 0.75² S2/S6 BLUE RFOU(C) 2PAIR ² S2/S6 GREY Yes RFOU(C) 2PAIR ² S2/S6 BLUE RFOU(C) 4PAIR ² S2/S6 GREY Yes RFOU(C) 4PAIR ² S2/S6 BLUE RFOU(C) 8PAIR ² S2/S6 GREY Yes RFOU(C) 8PAIR ² S2/S6 BLUE RFOU(C) 10PAIR ² S2/S6 GREY RFOU(C) 10PAIR ² S2/S6 BLUE RFOU(C) 12PAIR ² S2/S6 GREY RFOU(C) 12PAIR ² S2/S6 BLUE RFOU(C) 16PAIR ² S2/S6 GREY Yes RFOU(C) 16PAIR ² S2/S6 BLUE RFOU(C) 19PAIR ² S2/S6 GREY RFOU(C) 24PAIR ² S2/S6 GREY RFOU(C) 32PAIR ² S2/S6 GREY Subject to change without prior notice Page 10 of 212
12 New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No RFOU(C) 32PAIR ² S2/S6 BLUE RFOU(C) 2TRIP ² S2/S6 GREY RFOU(C) 2TRIP ² S2/S6 BLUE RFOU(C) 4TRIP ² S2/S6 GREY RFOU(C) 8TRIP ² S2/S6 BLUE RFOU(C) 12TRIP ² S2/S6 GREY RFOU(C) 12TRIP ² S2/S6 BLUE RFOU(C) 16TRIP ² S2/S6 GREY RFOU(C) 16TRIP ² S2/S6 BLUE RFOU(C) 24TRIP ² S2/S6 GREY RFOU(C) 24TRIP ² S2/S6 BLUE RFOU(C) 2PAIR 2.5² S2/S6 GREY RFOU(C) 4PAIR 2.5² S2/S6 GREY RFOU(C) 4PAIR 2.5² S2/S6 BLUE RFOU(C) 12PAIR 2.5² S2/S6 GREY Installation recoendations Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation Installation Installed Installation Temperature 8 x D 6 x D 50 N /² -20 C Subject to change without prior notice Page 11 of 212
13 Halogen-free, mud resistant, fire resistant instrumentation cable BFOU(i) 150/250(300)V, S3/S7 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeS3/S7 Operating temperature : 90 C Operating Voltage : 150/250(300)V Standards applied Application Fixed installation for instrumentation, counication, control and alarm systems in both EX (Zone 0, 1 & 2)- and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the mud resistant requirements in NEK TS 606:2009. IEC ( ) IEC class 2 IEC IEC IEC IEC IEC , -2, -21 IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation B Mica-tape + EP-rubber, IEC (EPR) Pair / Triple / Quad twisting Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by ed tape or by s printed directly on the insulated conductors. Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with a PETP tape. Lay up / Shielding Inner covering F Flame retardant and halogen-free thermoplastic compound Tape over inner PET tape covering Armour/screen O Tinned annealed copper wire braid Tape over PET tape armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) Eg. "meter" "year" DRAKA 01 BFOU(i) 250V S3/S7 16 PAIR 0,75 2 FLEX - FLAME IEC IEC *) or IEC *) IEC **) IEC DRAKA 01 = Draka Norsk Kabel Grey or Blue *) IEC for cables with an overall diameter exceeding 20 and IEC for cables with an overall diameter not exceeding 20 **) IEC also at enhanced temperature 1000 C for 180 minutes Subject to change without prior notice Page 12 of 212
14 Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey Range and dimensions Number of elements No of cores in element core, ² Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Mechanical cross of the braid, ² Thickness Outer Sheath, outer sheath, Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) ± ± ± ± ± ± ± ± ± ± ± 16.5 ± ± 16.5 ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± 19.5 ± ± 19.5 ± ± ± ± ± ± ± Subject to change without prior notice Page 13 of 212
15 Number No of of cores in elements element core, ² Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Mechanical cross of the braid, ² Thickness Outer Sheath, outer sheath, Weight of Cable Approx. (Kg/Km) ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± 18.5 ± ± 18.5 ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± 18.5 ± ± ± ± ± ± ± ± ± Copper content Approx. (kg/km) ± ± ± ± 30.5 ± 39.5 ± Electrical values instrumentation cables Type Capacitance, approx. Inductance, approx, Resistance at 20 C, max. L/R ratio, (nf/km) (mh/km) (Ohm/km) (microh/ohm) Shielded pair 0,75 ² 110 0,67 26,3 12,7 Shielded triple 0,75 ² 110 0,67 26,3 12,7 Shielded pair 1,5 ² 125 0,63 12,9 24,4 Shielded triple 1,5 ² 125 0,63 12,9 24,4 Shielded pair 2,5 ² 145 0,59 8,02 36,8 Shielded triple 2,5 ² 145 0,59 8,02 36,8 Shielded 16 and 24 triple 1,5 ² 105 0,71 12,9 24,4 Shielded 16 pair 2,5 ² 110 0,66 8,02 41,1 Subject to change without prior notice Page 14 of 212
16 Ordering information New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No BFOU(I) 1PAIR 0.75² S3/S7 GREY Yes BFOU(I) 1PAIR 0.75² S3/S7 BLUE Yes BFOU(I) 1QUAD 0.75² S3/S7 GREY BFOU(I) 2PAIR 0.75² S3/S7 GREY Yes BFOU(I) 2PAIR 0.75² S3/S7 BLUE Yes BFOU(I) 4PAIR 0.75² S3/S7 GREY Yes BFOU(I) 4PAIR 0.75² S3/S7 BLUE BFOU(I) 8PAIR 0.75² S3/S7 GREY Yes BFOU(I) 8PAIR 0.75² S3/S7 BLUE BFOU(I) 12PAIR 0.75² S3/S7 GREY BFOU(I) 12PAIR 0.75² S3/S7 BLUE BFOU(I) 16PAIR 0.75² S3/S7 GREY Yes BFOU(I) 16PAIR 0.75² S3/S7 BLUE BFOU(I) 19PAIR 0.75² S3/S7 GREY BFOU(I) 19PAIR 0.75² S3/S7 BLUE BFOU(I) 24PAIR 0.75² S3/S7 GREY BFOU(I) 24PAIR 0.75² S3/S7 BLUE BFOU(I) 1TRIP 0.75² S3/S7 GREY Yes BFOU(I) 1TRIP 0.75² S3/S7 BLUE BFOU(I) 2TRIP 0.75² S3/S7 GREY BFOU(I) 2TRIP 0.75² S3/S7 BLUE BFOU(I) 4TRIP 0.75² S3/S7 GREY BFOU(I) 4TRIP 0.75² S3/S7 BLUE BFOU(I) 8TRIP 0.75² S3/S7 GREY BFOU(I) 8TRIP 0.75² S3/S7 BLUE BFOU(I) 12TRIP 0.75² S3/S7 GREY BFOU(I) 12TRIP 0.75² S3/S7 BLUE BFOU(I) 16TRIP 0.75² S3/S7 GREY BFOU(I) 16TRIP 0.75² S3/S7 BLUE BFOU(I) 19TRIP 0.75² S3/S7 GREY BFOU(I) 24TRIP 0.75² S3/S7 GREY BFOU(I) 24TRIP 0.75² S3/S7 BLUE BFOU(I) 1PAIR ² S3/S7 GREY Yes BFOU(I) 1PAIR ² S3/S7 BLUE Yes BFOU(I) 2PAIR ² S3/S7 GREY Yes BFOU(I) 2PAIR ² S3/S7 BLUE BFOU(I) 4PAIR ² S3/S7 GREY Yes BFOU(I) 4PAIR ² S3/S7 BLUE BFOU(I) 8PAIR ² S3/S7 GREY Yes BFOU(I) 8PAIR ² S3/S7 BLUE BFOU(I) 12PAIR ² S3/S7 GREY Yes BFOU(I) 12PAIR ² S3/S7 BLUE BFOU(I) 16PAIR ² S3/S7 GREY Yes BFOU(I) 16PAIR ² S3/S7 BLUE BFOU(I) 19PAIR ² S3/S7 GREY BFOU(I) 24PAIR ² S3/S7 GREY Yes BFOU(I) 24PAIR ² S3/S7 BLUE BFOU(I) 1TRIP ² S3/S7 GREY Yes BFOU(I) 1TRIP ² S3/S7 BLUE BFOU(I) 2TRIP ² S3/S7 GREY BFOU(I) 2TRIP ² S3/S7 BLUE BFOU(I) 4TRIP ² S3/S7 GREY BFOU(I) 4TRIP ² S3/S7 BLUE BFOU(I) 8TRIP ² S3/S7 GREY BFOU(I) 8TRIP ² S3/S7 BLUE BFOU(I) 12TRIP ² S3/S7 GREY BFOU(I) 12TRIP ² S3/S7 BLUE BFOU(I) 16TRIP ² S3/S7 GREY BFOU(I) 16TRIP ² S3/S7 BLUE BFOU(I) 24TRIP ² S3/S7 GREY BFOU(I) 24TRIP ² S3/S7 BLUE BFOU(I) 1PAIR 2.5² S3/S7 GREY Yes BFOU(I) 1PAIR 2.5² S3/S7 BLUE BFOU(I) 2PAIR 2.5² S3/S7 GREY BFOU(I) 4PAIR 2.5² S3/S7 GREY Subject to change without prior notice Page 15 of 212
17 New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No BFOU(I) 8PAIR 2.5² S3/S7 GREY BFOU(I) 12PAIR 2.5² S3/S7 GREY BFOU(I) 16PAIR 2.5² S3/S7 GREY BFOU(I) 1TRIP 2.5² S3/S7 GREY BFOU(I) 8TRIP 2.5² S3/S7 GREY BFOU(I) 12TRIP 2.5² S3/S7 GREY Installation recoendations Minimum Bending Radius during Minimum Bending Radius Maximum Tensile Load During Minimum Installation Installation Fixed Installed Installation Temperature 8 x D 6 x D 50 N /² -20 C Subject to change without prior notice Page 16 of 212
18 Halogen-free, mud resistant, fire resistant instrumentation cable BFOU(c) 150/250(300)V, S4/S8 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU(c) 150/250(300)V MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeS4/S8 Operating temperature : 90 C Operating Voltage : 150/250(300)V Standards applied Application Fixed installation for instrumentation, counication, control and alarm systems in both EX (Zone 0, 1 & 2)- and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the mud resistant requirements in NEK TS 606:2009. IEC ( ) IEC class 2 IEC IEC IEC IEC IEC , -2, -21 IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation B Mica-tape + EP-rubber, IEC (EPR) Pair / Triple / Quad twisting Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire.pairs/triples are identified by ed tape or by s printed directly on the insulated conductors. Inner covering F Flame retardant and halogen-free thermoplastic compound Tape over inner PET tape covering Armour/screen O Tinned annealed copper wire braid Tape over armour/screen PET tape Outer sheath Marking text Manufacturing unit Outer sheath colour U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) Eg. "meter" "year" DRAKA 01 BFOU(c) 250V S4/S8 4 PAIR 0,75 2 FLEX - FLAME IEC IEC *) or IEC *) IEC **) IEC DRAKA 01 = Draka Norsk Kabel Grey or Blue *) IEC for cables with an overall diameter exceeding 20 and IEC for cables with an overall diameter not exceeding 20 **) IEC also at enhanced temperature 1000 C for 180 minutes Subject to change without prior notice Page 17 of 212
19 Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey Range and dimensions Number No of of cores in elements element core, ² Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Mechanical cross of the braid, ² Thickness Outer Sheath, outer sheath, Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) ± 14.5 ± ± 14.5 ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± 39.5 ± ± 39.5 ± ± ± Subject to change without prior notice Page 18 of 212
20 Number No of of cores in elements element core, ² Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Mechanical cross of the braid, ² Thickness Outer Sheath, outer sheath, Weight of Cable Approx. (Kg/Km) ± 18.5 ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± Copper content Approx. (kg/km) Electrical values instrumentation cables Type Capacitance, approx. (nf/km) Inductance, approx, (mh/km) Resistance at 20 C, max. (Ohm/km) L/R ratio, (microh/ohm) Unshielded pair 0,75 ² 100 0,67 26,3 12,7 Unshielded triple 0,75 ² 100 0,67 26,3 12,7 Unshielded pair 1,5 ² 110 0,63 12,9 24,4 Unshielded triple 1,5 ² 110 0,63 12,9 24,4 Unshielded pair 2,5 ² 125 0,59 8,02 36,8 Unshielded triple 2,5 ² 125 0,59 8,02 36,8 Unshielded 16 and 24 pair 2,5 ² 95 0,66 8,02 41,1 Unshielded 16 triple 2,5 ² 95 0,66 8,02 41,1 Ordering information New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No BFOU(C) 2PAIR 0.75² S4/S8 GREY Yes BFOU(C) 2PAIR 0.75² S4/S8 BLUE Yes BFOU(C) 4PAIR 0.75² S4/S8 GREY Yes BFOU(C) 4PAIR 0.75² S4/S8 BLUE Yes BFOU(C) 8PAIR 0.75² S4/S8 GREY Yes BFOU(C) 8PAIR 0.75² S4/S8 BLUE Yes BFOU(C) 12PAIR 0.75² S4/S8 GREY Yes BFOU(C) 12PAIR 0.75² S4/S8 BLUE BFOU(C) 16PAIR 0.75² S4/S8 GREY Yes BFOU(C) 16PAIR 0.75² S4/S8 BLUE BFOU(C) 19PAIR 0.75² S4/S8 GREY BFOU(C) 24PAIR 0.75² S4/S8 GREY Yes BFOU(C) 24PAIR 0.75² S4/S8 BLUE BFOU(C) 2TRIP 0.75² S4/S8 GREY BFOU(C) 2TRIP 0.75² S4/S8 BLUE BFOU(C) 4TRIP 0.75² S4/S8 GREY BFOU(C) 4TRIP 0.75² S4/S8 BLUE BFOU(C) 8TRIP 0.75² S4/S8 GREY Subject to change without prior notice Page 19 of 212
21 New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No BFOU(C) 8TRIP 0.75² S4/S8 BLUE Yes BFOU(C) 12TRIP 0.75² S4/S8 GREY BFOU(C) 12TRIP 0.75² S4/S8 BLUE BFOU(C) 16TRIP 0.75² S4/S8 GREY BFOU(C) 16TRIP 0.75² S4/S8 BLUE BFOU(C) 24TRIP 0.75² S4/S8 GREY BFOU(C) 2PAIR ² S4/S8 GREY Yes BFOU(C) 2PAIR ² S4/S8 BLUE BFOU(C) 4PAIR ² S4/S8 GREY Yes BFOU(C) 4PAIR ² S4/S8 BLUE BFOU(C) 8PAIR ² S4/S8 GREY Yes BFOU(C) 8PAIR ² S4/S8 BLUE BFOU(C) 12PAIR ² S4/S8 GREY Yes BFOU(C) 12PAIR ² S4/S8 BLUE BFOU(C) 16PAIR ² S4/S8 GREY Yes BFOU(C) 16PAIR ² S4/S8 BLUE BFOU(C) 24PAIR ² S4/S8 GREY Yes BFOU(C) 24PAIR ² S4/S8 BLUE BFOU(C) 2TRIP ² S4/S8 GREY BFOU(C) 2TRIP ² S4/S8 BLUE BFOU(C) 4TRIP ² S4/S8 GREY BFOU(C) 4TRIP ² S4/S8 BLUE BFOU(C) 8TRIP ² S4/S8 GREY Yes BFOU(C) 8TRIP ² S4/S8 BLUE BFOU(C) 12TRIP ² S4/S8 GREY BFOU(C) 12TRIP ² S4/S8 BLUE BFOU(C) 16TRIP ² S4/S8 GREY Yes BFOU(C) 16TRIP ² S4/S8 BLUE BFOU(C) 24TRIP ² S4/S8 GREY BFOU(C) 2PAIR 2.5² S4/S8 GREY BFOU(C) 4PAIR 2.5² S4/S8 GREY BFOU(C) 8PAIR 2.5² S4/S8 GREY BFOU(C) 8PAIR 2.5² S4/S8 BLUE BFOU(C) 12PAIR 2.5² S4/S8 GREY BFOU(C) 16PAIR 2.5² S4/S8 GREY BFOU(C) 24PAIR 2.5² S4/S8 GREY BFOU(C) 4TRIP 2.5² S4/S8 GREY BFOU(C) 8TRIP 2.5² S4/S8 GREY BFOU(C) 16TRIP 2.5² S4/S8 GREY Installation recoendations Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation Installation Installed Installation Temperature 8 x D 6 x D 50 N /² -20 C Subject to change without prior notice Page 20 of 212
22 Halogen-free, unarmoured mud resistant instrumentation cable RU(i) 150/250(300)V, S11 Flame retardant halogen-free instrumentation cable. Mud resistant RU(i) 150/250(300)V EPR/EVA NEK TS 606 CodeS11 Operating temperature : 90 C Operating Voltage : 150/250(300)V Standards applied Application Fixed installation for instrumentation, counication, Control and alarm systems in both EX- (Zone 2) and safe areas. Meets the mud resistant requirements in NEK TS 606:2009. IEC ( ) IEC class 2 IEC IEC IEC IEC IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation R EP-rubber, IEC (EPR) Pair / Triple / Quad twisting Lay up / Shielding Inner covering Armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour U Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by ed tape or by s printed directly on the insulated conductors. Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with a PETP tape. No inner covering. (Additional tapes may be applied) No armour. Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) E.g. "meter" "year" DRAKA 01 RU(i) 250V S11 2 pair 0,75 2 IEC IEC DRAKA 01 = Draka Norsk Kabel, Grey or Blue Subject to change without prior notice Page 21 of 212
23 Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey Range and dimensions Number of elements No of cores in element Conductor core,, ² Insulation Thickness Outer outer Weight of Cable Thickness, Sheath, sheath, Approx. (Kg/Km) ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± Copper content Approx. (kg/km) Electrical values instrumentation cables Type Capacitance, approx. (nf/km) Inductance, approx, (mh/km) Resistance at 20 C, max. (Ohm/km) L/R ratio, (microh/ohm) Shielded pair 0,75 ² 110 0,67 26,3 12,7 Shielded triple 0,75 ² 110 0,67 26,3 12,7 Shielded pair 1,5 ² 125 0,63 12,9 24,4 Shielded triple 1,5 ² 125 0,63 12,9 24,4 Shielded pair 2,5 ² 145 0,59 8,02 36,8 Shielded triple 2,5 ² 145 0,59 8,02 36,8 Ordering information New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No RU(I) 250V 1PAIR 0.75² S11 GREY RU(I) 250V 1PAIR 0.75² S11 BLUE RU(I) 250V 2PAIR 0.75² S11 GREY RU(I) 250V 2PAIR 0.75² S11 BLUE RU(I) 250V 4PAIR 0.75² S11 GREY RU(I) 250V 8PAIR 0.75² S11 GREY RU(I) 250V 12PAIR 0.75² S11 GREY RU(I) 250V 16PAIR 0.75² S11 GREY RU(I) 250V 24PAIR 0.75² S11 GREY Subject to change without prior notice Page 22 of 212
24 New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No RU(I) 250V 1TRIP 0.75² S11 GREY RU(I) 250V 2TRIP 0.75² S11 GREY RU(I) 250V 4TRIP 0.75² S11 GREY RU(I) 250V 8TRIP 0.75² S11 GREY RU(I) 250V 12TRIP 0.75² S11 GREY RU(I) 250V 16TRIP 0.75² S11 GREY RU(I) 250V 24TRIP 0.75² S11 GREY RU(I) 250V 1PAIR ² S11 GREY RU(I) 250V 1PAIR ² S11 BLUE RU(I) 250V 2PAIR ² S11 GREY RU(I) 250V 2PAIR ² S11 BLUE RU(I) 250V 4PAIR ² S11 GREY RU(I) 250V 8PAIR ² S11 GREY RU(I) 250V 12PAIR ² S11 GREY RU(I) 250V 16PAIR ² S11 GREY RU(I) 250V 24PAIR ² S11 GREY RU(I) 250V 1TRIP ² S11 GREY RU(I) 250V 2TRIP ² S11 GREY RU(I) 250V 4TRIP ² S11 GREY RU(I) 250V 8TRIP ² S11 GREY RU(I) 250V 16TRIP ² S11 GREY RU(I) 250V 24TRIP ² S11 GREY Installation recoendations Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation Installation Installed Installation Temperature 8 x D 6 x D 50 N /² -20 C Subject to change without prior notice Page 23 of 212
25 Halogen-free, unarmoured mud resistant instrumentation cable RU(c) 150/250(300)V, S12 Flame retardant halogen-free instrumentation cable. Mud resistant RU(c) 150/250(300)V EPR/EVA NEK TS 606 CodeS12 Operating temperature : 90 C Operating Voltage : 150/250(300)V Standards applied Application Fixed installation for instrumentation, counication, Control and alarm systems in both EX- (Zone 2) and safe areas. Meets the mud resistant requirements in NEK TS 606:2009. IEC ( ) IEC class 2 IEC IEC IEC IEC IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation R EP-rubber, IEC (EPR) Pair / Triple / Quad twisting Inner covering Armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour U Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire.pairs/triples are identified by ed tape or by s printed directly on the insulated conductors. No inner covering. (Additional tapes may be applied) No armour. Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) E.g. "meter" "year" DRAKA 01 RU(c) 250V S12 2 pair 0,75 2 IEC IEC DRAKA 01 = Draka Norsk Kabel, Grey or Blue Subject to change without prior notice Page 24 of 212
26 Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey Range and dimensions Number of elements No of cores in element Conductor core,, ² Insulation Thickness Outer outer Weight of Cable Thickness, Sheath, sheath, Approx. (Kg/Km) ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± Copper content Approx. (kg/km) Electrical values instrumentation cables Type Capacitance, approx. (nf/km) Inductance, approx, (mh/km) Resistance at 20 C, max. (Ohm/km) L/R ratio, (microh/ohm) Unshielded pair 0,75 ² 100 0,67 26,3 12,7 Unshielded triple 0,75 ² 100 0,67 26,3 12,7 Unshielded pair 1,5 ² 110 0,63 12,9 24,4 Unshielded triple 1,5 ² 110 0,63 12,9 24,4 Unshielded pair 2,5 ² 125 0,59 8,02 36,8 Unshielded triple 2,5 ² 125 0,59 8,02 36,8 Ordering information New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No RU(C) 250V 2PAIR 0.75² S12 GREY RU(C) 250V 4PAIR 0.75² S12 GREY RU(C) 250V 4PAIR 0.75² S12 BLUE RU(C) 250V 8PAIR 0.75² S12 GREY RU(C) 250V 12PAIR 0.75² S12 GREY RU(C) 250V 16PAIR 0.75² S12 GREY RU(C) 250V 19PAIR 0.75² S12 GREY RU(C) 250V 24PAIR 0.75² S12 GREY RU(C) 250V 2TRIP 0.75² S12 GREY RU(C) 250V 4TRIP 0.75² S12 GREY RU(C) 250V 4TRIP 0.75² S12 BLUE RU(C) 250V 8TRIP 0.75² S12 GREY RU(C) 250V 16TRIP 0.75² S12 GREY Subject to change without prior notice Page 25 of 212
27 New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No RU(C) 250V 24TRIP 0.75² S12 GREY RU(C) 250V 2PAIR ² S12 GREY RU(C) 250V 4PAIR ² S12 GREY RU(C) 250V 8PAIR ² S12 GREY RU(C) 250V 12PAIR ² S12 GREY RU(C) 250V 12PAIR ² S12 BLUE RU(C) 250V 16PAIR ² S12 GREY RU(C) 250V 24PAIR ² S12 GREY RU(C) 250V 2TRIP ² S12 GREY RU(C) 250V 4TRIP ² S12 GREY RU(C) 250V 8TRIP ² S12 GREY RU(C) 250V 12TRIP ² S12 GREY RU(C) 250V 16TRIP ² S12 GREY RU(C) 250V 24TRIP ² S12 GREY Installation recoendations Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation Installation Installed Installation Temperature 8 x D 6 x D 50 N /² -20 C Subject to change without prior notice Page 26 of 212
28 Halogen-free, fire resistant, unarmoured, mud resistant instrumentation cable BU(i) 150/250(300)V, S13 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BU(i) 150/250(300)V MGT/EPR/EVA NEK TS 606 CodeS13 Operating temperature : 90 C Operating Voltage : 150/250(300)V Standards applied Application Fixed installation for instrumentation, counication, control and alarm systems in both EX-(Zone 2) and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the mud resistant requirements in NEK TS 606:2009. IEC ( ) IEC class 2 IEC IEC IEC IEC IEC , -2, -21 IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation B Mica-tape + EP-rubber, IEC (EPR) Pair / Triple / Quad twisting Lay up / Shielding Inner covering Armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour U Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by ed tape or by s printed directly on the insulated conductors. Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with a PETP tape. No inner covering. (Additional tapes may be applied) No armour. Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) "meter" "year" DRAKA 01 BU(i) 250V S13 8 PAIR 0,75 2 FLEX - FLAME IEC IEC *) or IEC *) IEC **) IEC DRAKA 01 = Draka Norsk Kabel, Grey or Blue *) IEC for cables with an overall diameter exceeding 20 and IEC for cables with an overall diameter not exceeding 20 **) IEC also at enhanced temperature 1000 C for 180 minutes Subject to change without prior notice Page 27 of 212
29 Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey Range and dimensions Number of elements No of cores in element Conductor core,, ² Insulation Thickness Outer outer Weight of Cable Thickness, Sheath, sheath, Approx. (Kg/Km) ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± Copper content Approx. (kg/km) Electrical values instrumentation cables Type Capacitance, approx. (nf/km) Inductance, approx, (mh/km) Resistance at 20 C, max. (Ohm/km) L/R ratio, (microh/ohm) Shielded pair 0,75 ² 110 0,67 26,3 12,7 Shielded triple 0,75 ² 110 0,67 26,3 12,7 Shielded pair 1,5 ² 125 0,63 12,9 24,4 Shielded triple 1,5 ² 125 0,63 12,9 24,4 Shielded pair 2,5 ² 145 0,59 8,02 36,8 Shielded triple 2,5 ² 145 0,59 8,02 36,8 Ordering information New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No BU(I) 250V 1PAIR 0.75² S13 GREY BU(I) 250V 1PAIR 0.75² S13 BLUE Subject to change without prior notice Page 28 of 212
30 BU(I) 250V 2PAIR 0.75² S13 GREY BU(I) 250V 2PAIR 0.75² S13 BLUE BU(I) 250V 4PAIR 0.75² S13 GREY BU(I) 250V 8PAIR 0.75² S13 GREY BU(I) 250V 12PAIR 0.75² S13 GREY BU(I) 250V 12PAIR 0.75² S13 BLUE BU(I) 250V 16PAIR 0.75² S13 GREY BU(I) 250V 24PAIR 0.75² S13 GREY BU(I) 250V 1TRIP 0.75² S13 GREY BU(I) 250V 2TRIP 0.75² S13 GREY BU(I) 250V 4TRIP 0.75² S13 GREY BU(I) 250V 8TRIP 0.75² S13 GREY BU(I) 250V 12TRIP 0.75² S13 GREY BU(I) 250V 16TRIP 0.75² S13 GREY BU(I) 250V 24TRIP 0.75² S13 GREY BU(I) 250V 1PAIR ² S13 GREY BU(I) 250V 1PAIR ² S13 BLUE BU(I) 250V 2PAIR ² S13 GREY BU(I) 250V 2PAIR ² S13 BLUE BU(I) 250V 4PAIR ² S13 GREY BU(I) 250V 4PAIR ² S13 BLUE BU(I) 250V 8PAIR ² S13 GREY BU(I) 250V 8PAIR ² S13 BLUE BU(I) 250V 12PAIR ² S13 GREY BU(I) 250V 12PAIR ² S13 BLUE BU(I) 250V 16PAIR ² S13 GREY BU(I) 250V 24PAIR ² S13 GREY BU(I) 250V 24PAIR ² S13 BLUE BU(I) 250V 1TRIP ² S13 GREY BU(I) 250V 1TRIP ² S13 BLUE BU(I) 250V 2TRIP ² S13 GREY BU(I) 250V 4TRIP ² S13 GREY BU(I) 250V 8TRIP ² S13 GREY BU(I) 250V 12TRIP ² S13 GREY BU(I) 250V 16TRIP ² S13 GREY BU(I) 250V 24TRIP ² S13 GREY BU(I) 250V 1PAIR 2.5² S13 GREY Installation recoendations Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation Installation Installed Installation Temperature 8 x D 6 x D 50 N /² -20 C Subject to change without prior notice Page 29 of 212
31 Halogen-free, fire resistant, unarmoured, mud resistant instrumentation cable BU(c) 150/250(300)V, S14 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BU(c) 150/250(300)V MGT/EPR/EVA NEK TS 606 CodeS14 Operating temperature : 90 C Operating Voltage : 150/250(300)V Standards applied Application Fixed installation for instrumentation, counication, control and alarm systems in both EX-(Zone 2) and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the mud resistant requirements in NEK TS 606:2009. IEC ( ) IEC class 2 IEC IEC IEC IEC IEC , -2, 21 IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation B Mica-tape + EP-rubber, IEC (EPR) Pair / Triple / Quad twisting Inner covering Armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour U Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire.pairs/triples are identified by ed tape or by s printed directly on the insulated conductors. No inner covering. (Additional tapes may be applied) No armour. Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) "meter" "year" DRAKA 01 BU(c) 250V S14 8 PAIR 0,75 2 FLEX - FLAME IEC IEC *) or IEC *) IEC **) IEC DRAKA 01 = Draka Norsk Kabel, Grey or Blue *) IEC for cables with an overall diameter exceeding 20 and IEC for cables with an overall diameter not exceeding 20 **) IEC also at enhanced temperature 1000 C for 180 minutes Subject to change without prior notice Page 30 of 212
32 Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey Range and dimensions Number of elements No of cores in element Conductor core,, ² Insulation Thickness Outer outer Weight of Cable Thickness, Sheath, sheath, Approx. (Kg/Km) ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± Copper content Approx. (kg/km) Electrical values instrumentation cables Type Capacitance, approx. (nf/km) Inductance, approx, (mh/km) Resistance at 20 C, max. (Ohm/km) L/R ratio, (microh/ohm) Unshielded pair 0,75 ² 100 0,67 26,3 12,7 Unshielded triple 0,75 ² 100 0,67 26,3 12,7 Unshielded pair 1,5 ² 110 0,63 12,9 24,4 Unshielded triple 1,5 ² 110 0,63 12,9 24,4 Unshielded pair 2,5 ² 125 0,59 8,02 36,8 Unshielded triple 2,5 ² 125 0,59 8,02 36,8 Ordering information New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No BU(C) 250V 2PAIR 0.75² S14 GREY BU(C) 250V 4PAIR 0.75² S14 GREY BU(C) 250V 8PAIR 0.75² S14 GREY BU(C) 250V 12PAIR 0.75² S14 GREY BU(C) 250V 12PAIR 0.75² S14 BLUE BU(C) 250V 16PAIR 0.75² S14 GREY BU(C) 250V 19PAIR 0.75² S14 GREY BU(C) 250V 24PAIR 0.75² S14 GREY BU(C) 250V 2TRIP 0.75² S14 GREY BU(C) 250V 4TRIP 0.75² S14 GREY BU(C) 250V 8TRIP 0.75² S14 GREY BU(C) 250V 12TRIP 0.75² S14 GREY Subject to change without prior notice Page 31 of 212
33 New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No BU(C) 250V 16TRIP 0.75² S14 GREY BU(C) 250V 24TRIP 0.75² S14 GREY BU(C) 250V 2PAIR ² S14 GREY BU(C) 250V 4PAIR ² S14 GREY BU(C) 250V 8PAIR ² S14 GREY BU(C) 250V 12PAIR ² S14 GREY BU(C) 250V 16PAIR ² S14 GREY BU(C) 250V 24PAIR ² S14 GREY BU(C) 250V 2TRIP ² S14 GREY BU(C) 250V 4TRIP ² S14 GREY BU(C) 250V 8TRIP ² S14 GREY BU(C) 250V 12TRIP ² S14 GREY BU(C) 250V 16TRIP ² S14 GREY BU(C) 250V 24TRIP ² S14 GREY BU(C) 250V 2PAIR 2.5² S14 GREY Installation recoendations Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation Installation Installed Installation Temperature 8 x D 6 x D 50 N /² -20 C Subject to change without prior notice Page 32 of 212
34 Halogen-free, mud resistant power cable RFOU 0,6/1(1,2)kV, P1/P8 Flame retardant halogen-free power cable. Mud resistant RFOU 0,6/1(1,2)kV EPR/EPR/TCWB/EVA NEK TS 606 CodeP1/P8 Operating temperature : 90 C Operating Voltage : 0,6/1(1,2)kV Standards applied Application Fixed installation for power,control and lighting in both EX (Zone 0, 1 & 2)- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009. IEC IEC class 2 IEC IEC IEC IEC IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation R EP-rubber, IEC (EPR) Lay up / Shielding Cores laid up in concentric layers Inner covering F Flame retardant and halogen-free thermoset compound Tape over inner PET tape covering Armour/screen O Tinned annealed copper wire braid Tape over armour/screen PET tape Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) Marking text E.g. "meter" "year" DRAKA 01 RFOU 0,6/1KV P1/P8 3 x 35/16 2 IEC Manufacturing unit DRAKA 01 = Draka Norsk Kabel, Outer sheath colour Black Subject to change without prior notice Page 33 of 212
35 Core identification power cables Single core Black Two cores - Blue Brown Three cores - Brown - Black Grey Four cores - Blue - Brown - Black Grey Five cores - Blue - Brown - Black - Grey Black Seven cores and above - White with black s Two cores + earth (3G) - Yellow/green - Blue Brown Three cores + earth (4G) - Yellow/green - Brown - Black Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC Ed Range and dimensions Number of elements core, ² Electrical braid, ² Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Mechanical cross- of the braid, ² Thickness Outer outer Sheath, sheath, Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± G ± ± G ± ± G ± ± G ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± G ± ± G ± ± G ± ± G ± ± ± ± ± ± ± ± ± ± G ± ± G ± ± G ± ± ± ± ± ± ± ± G ± ± G ± ± G ± ± Subject to change without prior notice Page 34 of 212
36 Number of elements core, ² Electrical braid, ² Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Mechanical Braid cross- Wire, of the braid, ² Thickness Outer outer Sheath, sheath, Weight of Cable Approx. (Kg/Km) ± ± ± ± ± ± G ± ± G ± ± G ± ± ± ± ± ± ± ± ± ± G ± ± G ± ± G ± ± ± ± ± ± ± ± G ± ± G ± ± G ± ± ± ± ± ± ± ± G ± ± G ± ± ± ± ± ± ± ± G ± ± G ± ± ± ± ± ± ± ± ± ± G ± ± G ± ± ± ± ± ± ± ± G ± ± ± ± ± ± ± ± G ± ± G ± ± G ± ± G ± ± G ± ± Copper content Approx. (kg/km) Ordering information New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No RFOU 0.6/1kV 1X 16/2.5 P1/P8 BLACK RFOU 0.6/1kV 1X 25/4² P1/P8 BLACK RFOU 0.6/1kV 1X 35/6² P1/P8 BLACK RFOU 0.6/1kV 1X 50/6² P1/P8 BLACK RFOU 0.6/1kV 1X 70/10² P1/P8 BLACK RFOU 0.6/1kV 1X 95/10² P1/P8 BLACK Subject to change without prior notice Page 35 of 212
37 New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No RFOU 0.6/1kV 1X 120/10 P1/P8 BLACK RFOU 0.6/1kV 1X 150/10 P1/P8 BLACK RFOU 0.6/1kV 1X 185/10 P1/P8 BLACK RFOU 0.6/1kV 1X 240/16 P1/P8 BLACK RFOU 0.6/1kV 1X 300/16 P1/P8 BLACK Yes RFOU 0.6/1kV 2X /4² P1/P8 BLACK Yes RFOU 0.6/1kV 3X /4² P1/P8 BLACK Yes RFOU 0.6/1kV 4X /6² P1/P8 BLACK Yes RFOU 0.6/1kV 5X /6² P1/P8 BLACK RFOU 0.6/1kV 7X /6² P1/P8 BLACK Yes RFOU 0.6/1kV 12X /10 P1/P8 BLACK RFOU 0.6/1kV 19X /10 P1/P8 BLACK Yes RFOU 0.6/1kV 27X /10 P1/P8 BLACK RFOU 0.6/1kV 37X /16 P1/P8 BLACK RFOU 0.6/1kV 3G ² P1/P8 BLACK RFOU 0.6/1kV 4G ² P1/P8 BLACK RFOU 0.6/1kV 5G ² P1/P8 BLACK RFOU 0.6/1kV 7G ² P1/P8 BLACK RFOU 0.6/1kV 2X 2.5/4² P1/P8 BLACK Yes RFOU 0.6/1kV 3X 2.5/6² P1/P8 BLACK Yes RFOU 0.6/1kV 4X 2.5/6² P1/P8 BLACK Yes RFOU 0.6/1kV 5X 2.5/6² P1/P8 BLACK RFOU 0.6/1kV 7X 2.5/6² P1/P8 BLACK RFOU 0.6/1kV 12X 2.5/10 P1/P8 BLACK RFOU 0.6/1kV 19X 2.5/10 P1/P8 BLACK RFOU 0.6/1kV 27X 2.5/16 P1/P8 BLACK RFOU 0.6/1kV 37X 2.5/16 P1/P8 BLACK RFOU 0.6/1kV 3G 2.5² P1/P8 BLACK Yes RFOU 0.6/1kV 4G 2.5² P1/P8 BLACK RFOU 0.6/1kV 5G 2.5² P1/P8 BLACK RFOU 0.6/1kV 7G 2.5² P1/P8 BLACK RFOU 0.6/1kV 2X 4/6² P1/P8 BLACK Yes RFOU 0.6/1kV 3X 4/6² P1/P8 BLACK Yes RFOU 0.6/1kV 4X 4/6² P1/P8 BLACK RFOU 0.6/1kV 5X 4/6² P1/P8 BLACK RFOU 0.6/1kV 3G 4² P1/P8 BLACK Yes RFOU 0.6/1kV 4G 4² P1/P8 BLACK RFOU 0.6/1kV 5G 4² P1/P8 BLACK RFOU 0.6/1kV 2X 6/6² P1/P8 BLACK Yes RFOU 0.6/1kV 3X 6/6² P1/P8 BLACK Yes RFOU 0.6/1kV 4X 6/6² P1/P8 BLACK RFOU 0.6/1kV 3G 6² P1/P8 BLACK RFOU 0.6/1kV 4G 6² P1/P8 BLACK RFOU 0.6/1kV 5G 6² P1/P8 BLACK RFOU 0.6/1kV 2X 10/10² P1/P8 BLACK RFOU 0.6/1kV 3X 10/10² P1/P8 BLACK Yes RFOU 0.6/1kV 4X 10/10² P1/P8 BLACK RFOU 0.6/1kV 3G 10² P1/P8 BLACK RFOU 0.6/1kV 4G 10² P1/P8 BLACK RFOU 0.6/1kV 5G 10² P1/P8 BLACK RFOU 0.6/1kV 2X 16/16² P1/P8 BLACK RFOU 0.6/1kV 3X 16/16² P1/P8 BLACK Yes RFOU 0.6/1kV 4X 16/16² P1/P8 BLACK Yes RFOU 0.6/1kV 5X 16/16² P1/P8 BLACK RFOU 0.6/1kV 3G 16² P1/P8 BLACK RFOU 0.6/1kV 4G 16² P1/P8 BLACK RFOU 0.6/1kV 5G 16² P1/P8 BLACK RFOU 0.6/1kV 2X 25/16² P1/P8 BLACK RFOU 0.6/1kV 3X 25/16² P1/P8 BLACK Yes Subject to change without prior notice Page 36 of 212
38 New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No RFOU 0.6/1kV 4X 25/16² P1/P8 BLACK Yes RFOU 0.6/1kV 3G 25² P1/P8 BLACK RFOU 0.6/1kV 4G 25² P1/P8 BLACK RFOU 0.6/1kV 5G 25² P1/P8 BLACK RFOU 0.6/1kV 2X 35/16² P1/P8 BLACK RFOU 0.6/1kV 3X 35/16² P1/P8 BLACK Yes RFOU 0.6/1kV 4X 35/16² P1/P8 BLACK RFOU 0.6/1kV 4G 35² P1/P8 BLACK RFOU 0.6/1kV 5G 35² P1/P8 BLACK RFOU 0.6/1kV 2X 50/25² P1/P8 BLACK RFOU 0.6/1kV 3X 50/25² P1/P8 BLACK Yes RFOU 0.6/1kV 4X 50/25² P1/P8 BLACK RFOU 0.6/1kV 4G 50² P1/P8 BLACK RFOU 0.6/1kV 5G 50² P1/P8 BLACK RFOU 0.6/1kV 2X 70/35² P1/P8 BLACK RFOU 0.6/1kV 3X 70/35² P1/P8 BLACK Yes RFOU 0.6/1kV 4X 70/35² P1/P8 BLACK RFOU 0.6/1kV 5X 70/35² P1/P8 BLACK RFOU 0.6/1kV 4G 70² P1/P8 BLACK RFOU 0.6/1kV 5G 70² P1/P8 BLACK RFOU 0.6/1kV 2X 95/50² P1/P8 BLACK RFOU 0.6/1kV 3X 95/50² P1/P8 BLACK Yes RFOU 0.6/1kV 4X 95/50² P1/P8 BLACK Yes RFOU 0.6/1kV 4G 95² P1/P8 BLACK RFOU 0.6/1kV 2X 120/60 P1/P8 BLACK RFOU 0.6/1kV 3X 120/60 P1/P8 BLACK Yes RFOU 0.6/1kV 4X 120/60 P1/P8 BLACK RFOU 0.6/1kV 4G 120² P1/P8 BLACK RFOU 0.6/1kV 5G 120² P1/P8 BLACK RFOU 0.6/1kV 4G 150² P1/P8 BLACK RFOU 0.6/1kV 5G 150² P1/P8 BLACK RFOU 0.6/1kV 4G 185² P1/P8 BLACK Electrical values power cables Number of elements core, ² Electrical braid, ² Conductor type 2 Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere Short circuit rating 1 second, Ampere STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC Subject to change without prior notice Page 37 of 212
39 Number of elements core, ² Electrical braid, ² Conductor type 2 Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere 7 6 STCC STCC STCC STCC STCC G - STCC G - STCC G - STCC G - STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC G STCC G STCC G STCC G STCC STCC STCC STCC STCC G 4 - STCC G 4 - STCC G 4 - STCC STCC STCC STCC G 6 - STCC G 6 - STCC G 6 - STCC STCC STCC STCC G 10 - STCC G 10 - STCC G 10 - STCC Short circuit rating 1 second, Ampere STCC STCC STCC STCC G 16 - STCC G 16 - STCC G 16 - STCC STCC STCC STCC G 25 - STCC G 25 - STCC G 25 - STCC STCC Subject to change without prior notice Page 38 of 212
40 Number of elements core, ² Electrical braid, ² Conductor type 2 Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere STCC STCC G 35 - STCC G 35 - STCC STCC STCC STCC G 50 - STCC G 50 - STCC STCC STCC STCC STCC G 70 - STCC G 70 - STCC STCC STCC STCC G 95 - STCC STCC STCC STCC G STCC G STCC G STCC G STCC G STCC Short circuit rating 1 second, Ampere Ambient temperature correction factors Ambient Temp C Rating factor Installation recoendations Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation Installation Installed Installation Temperature 8 x D 6 x D 50 N /² -20 C Subject to change without prior notice Page 39 of 212
41 Halogen-free, mud resistant power cable RFOU 0,6/1(1,2)kV, P1/P8, large single core cables Flame retardant halogen-free power cable. Mud resistant. Single core cable. RFOU 0,6/1(1,2)kV EPR/EPR/TCWB/EVA NEK TS 606 CodeP1/P8 Operating temperature : 90 C Operating Voltage : 0,6/1(1,2)kV Standards applied Application Fixed installation for power,control and lighting in both EX (Zone 0, 1 & 2)- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009. IEC IEC class 2 IEC IEC IEC IEC IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation R EP-rubber, IEC (EPR) Lay up / Shielding Cores laid up in concentric layers Inner covering F Flame retardant and halogen-free thermoset compound Tape over inner PET tape covering Armour/screen O Tinned annealed copper wire braid Tape over armour/screen PET tape Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) Marking text E.g. "meter" "year" DRAKA 01 RFOU 0,6/1KV P1/P8 1 x 500/25 2 IEC Manufacturing unit DRAKA 01 = Draka Norsk Kabel, Outer sheath colour Black Subject to change without prior notice Page 40 of 212
42 Core identification power cables Single core - Black Two cores - Blue - Brown Three cores - Brown - Black - Grey Four cores - Blue - Brown - Black - Grey Five cores - Blue - Brown - Black - Grey - Black Seven cores and above - White with black s Two cores + earth (3G) - Yellow/green - Blue - Brown Three cores + earth (4G) - Yellow/green - Brown - Black - Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC ED Range and dimensions Number of elements core, ² Electrical braid, ² Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Mechanical cross of the braid, ² Thickness Outer Sheath, outer sheath, Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) ± ± ± ± ± ± Ordering information New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No RFOU 0.6/1kV 1X 400/25 P1/P8 BLACK RFOU 0.6/1kV 1X 500/25 P1/P8 BLACK RFOU 0.6/1kV 1X 630/25 P1/P8 BLACK Electrical values power cables Number of elements core, ² Electrical braid, ² Conductor type 2 Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere Short circuit rating 1 second, Ampere STCC STCC STCC dc / 670 ac 780 dc / 720 ac 890 dc / 780 ac Ambient temperature correction factors Ambient Temp C Rating factor Installation recoendations Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation Installation Installed Installation Temperature 8 x D 6 x D 50 N /² -20 C Subject to change without prior notice Page 41 of 212
43 Halogen-free, mud resistant power cable RFOU 0,6/1(1,2)kV, P1/P8, double braided Flame retardant halogen-free power cable. Mud resistant. Double braided. RFOU 0,6/1(1,2)kV EPR/EPR/TCWB/EVA NEK TS 606 CodeP1/P8 Operating temperature : 90 C Operating Voltage : 0,6/1(1,2)kV Standards applied Application Fixed installation for power,control and lighting in both EX (Zone 0, 1 & 2)- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009. IEC IEC class 2 IEC IEC IEC IEC IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation R EP-rubber, IEC (EPR) Lay up / Shielding Cores laid up in concentric layers Inner covering F Flame retardant and halogen-free thermoset compound Tape over inner PET tape + rubberized Polyamide tape covering Armour/screen O Two layers of tinned copper wire braid (double braid) Tape over armour/screen PET tape + rubberized Polyamide tape Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) Marking text E.g. "meter" "year" DRAKA 01 RFOU 0,6/1kV P1/P8 3 x 185/95 2 IEC Manufacturing unit DRAKA 01 = Draka Norsk Kabel, Outer sheath colour Black Subject to change without prior notice Page 42 of 212
44 Core identification power cables Single core - Black Two cores - Blue - Brown Three cores - Brown - Black - Grey Four cores - Blue - Brown - Black - Grey Five cores - Blue - Brown - Black - Grey - Black Seven cores and above - White with black s Two cores + earth (3G) - Yellow/green - Blue - Brown Three cores + earth (4G) - Yellow/green - Brown - Black - Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC ED Range and dimensions Number of elements core, ² Electrical braid, ² Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Mechanical cross of the braid, ² Thickness Outer Sheath, outer sheath, Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) ± ± ± ± ± ± ± ± ± ± Ordering information New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No RFOU 0.6/1kV 3X 150/75 P1/P8 BLACK RFOU 0.6/1kV 4X 150/75 P1/P8 BLACK RFOU 0.6/1kV 3X 185/95 P1/P8 BLACK RFOU 0.6/1kV 4X 185/95 P1/P8 BLACK RFOU 0.6/1kV 3X 240/120 P1/P8 BLACK Electrical values power cables Number of elements core, ² Electrical braid, ² Conductor type 2 Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere Short circuit rating 1 second, Ampere STCC STCC STCC STCC STCC Ambient temperature correction factors Ambient Temp C Rating factor Installation recoendations Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation Installation Installed Installation Temperature 8 x D 6 x D 50 N /² -20 C Subject to change without prior notice Page 43 of 212
45 Halogen-free, mud resistant MV power cable, RFOU 3,6/6(7,2)kV, P2/P9 Flame retardant halogen-free medium voltage (MV) cable. Mud resistant RFOU 3,6/6(7,2) kv EPR/EPR/TCWB/EVA NEK 606 CodeP2/P9 Operating temperature : 90 C Operating Voltage : 3,6/6(7,2) kv Standards applied Application Fixed installation for medium voltage (MV) power in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. IEC IEC class 2 IEC IEC IEC IEC IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned stranded and compressed copper (STCC), IEC class 2 Conductor screen Semiconductive layer (EP-rubber) semiconductive Insulation R EP-rubber, IEC (EPR) Insulation screen Semiconductive layer (EP-rubber) semicoductive Lay up / Shielding Cores are laid up together. Cores are identified by Brown, Black or Grey threads under and over the metallic screen on each conductor. Inner covering F Flame retardant and halogen-free thermoset compound Tape over inner PET tape covering Armour/screen O Tinned annealed copper wire braid Tape over armour/screen PET tape Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) Marking text E.g. "meter" "year" DRAKA 04 RFOU 3,6/6(7,2)KV P2/P9 3 x 120/60 2 IEC Manufacturing unit DRAKA 04 = Draka Industrial Cable, Germany Outer sheath colour Red Subject to change without prior notice Page 44 of 212
46 Range and dimensions Number of elements core, ² screen, ² Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Thickness Outer Sheath, outer sheath, Weight of Cable Approx. (Kg/Km) ,2 2,5 1,0 16,5±1,0 0,3 1,6 22,0±1, ,5 2,5 1,0 18,0±1,0 0,3 1,6 23,0±1, ,4 2,5 1,0 19,0±1,0 0,3 1,6 24,0±1, ,8 2,5 1,0 20,5±1,0 0,3 1,7 25,5±1, ,3 2,5 1,0 22,0±1,0 0,3 1,8 27,5±1, ,1 2,5 1,0 24,0±1,5 0,3 1,9 29,5±1, ,6 2,5 1,0 25,0±1,5 0,4 1,9 31,5±2, ,1 2,5 1,2 27,0±1,5 0,4 2,0 33,5±2, ,8 2,5 1,2 28,5±1,5 0,4 2,0 35,0±2, ,1 2,6 1,2 31,5±1,5 0,4 2,1 37,5±2, ,5 2,8 1,2 34,0±1,5 0,4 2,2 41,0±2, Copper content Approx. (kg/km) ,2 2,5 1,2 34,5±1,5 0,4 2,3 42,0±2, ,5 2,5 1,2 37,5±1,5 0,4 2,4 45,0±2, ,4 2,5 1,2 39,5±1,5 0,4 2,5 47,0±2, ,8 2,5 1,4 43,0±2,0 0,4 2,6 50,5±3, ,3 2,5 1,4 46,0±2,0 0,5 2,7 54,5±3, ,1 2,5 1,4 50,0±2,0 0,5 2,8 58,5±3, ,6 2,5 1,6 53.5± ,0 62.5± ,1 2,5 1,6 56,5±2,0 0,5 3,1 66,5±3, ,8 2,5 1,6 60,5±2,5 0,6 3,2 70,0±3, ,1 2,6 1,8 66,5±2,5 0,6 3,5 77,0±4, ,5 2,8 1,8 70,0±3,0 0,6 3,6 80,5±4, Ordering information New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No RFOU 3.6/6KV 1X 16/11² P2/P9 RED RFOU 3.6/6KV 1X 25/11² P2/P9 RED RFOU 3.6/6KV 1X 35/13² P2/P9 RED RFOU 3.6/6KV 1X 50/13² P2/P9 RED RFOU 3.6/6KV 1X 70/16² P2/P9 RED RFOU 3.6/6KV 1X 95/16² P2/P9 RED RFOU 3.6/6KV 1X 120/20² P2/P9 RED RFOU 3.6/6KV 1X 150/22² P2/P9 RED RFOU 3.6/6KV 1X 185/25² P2/P9 RED RFOU 3.6/6KV 1X 240/25² P2/P9 RED RFOU 3.6/6KV 1X 300/30² P2/P9 RED RFOU 3.6/6KV 3X 16/35² P2/P9 RED RFOU 3.6/6KV 3X 25/35² P2/P9 RED RFOU 3.6/6KV 3X 35/35² P2/P9 RED RFOU 3.6/6KV 3X 50/35² P2/P9 RED RFOU 3.6/6KV 3X 70/45² P2/P9 RED RFOU 3.6/6KV 3X 95/50² P2/P9 RED RFOU 3.6/6KV 3X 120/60² P2/P9 RED RFOU 3.6/6KV 3X 150/75² P2/P9 RED RFOU 3.6/6KV 3X 185/95² P2/P9 RED RFOU 3.6/6KV 3X 240/95² P2/P9 RED RFOU 3.6/6KV 3X 300/95² P2/P9 RED Subject to change without prior notice Page 45 of 212
47 Electrical values power cables Number of elements core, ² screen, ² Conductor type 2 Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Capacitans per phase, nf/km Current rating IEC Table B.4, Ampere Short circuit rating 1 second, Ampere STCC 1,16 1,48 0,149 0, STCC 0,734 0,936 0,139 0, STCC 0,529 0,675 0,133 0, STCC 0,391 0,499 0,126 0, STCC 0,270 0,344 0,121 0, STCC 0,195 0,249 0,115 0, STCC 0,154 0,196 0,119 0, STCC 0,126 0,161 0,109 0, STCC 0,100 0,128 0,105 0, STCC 0,0762 0,0972 0,102 0, STCC 0,0607 0,0774 0,099 0, STCC 1,16 1,48 0,121 0, STCC 0,734 0,936 0,112 0, STCC 0,529 0,675 0,108 0, STCC 0,391 0,499 0,102 0, STCC 0,270 0,344 0,097 0, STCC 0,195 0,249 0,093 0, STCC 0,154 0, , STCC 0,126 0,161 0,088 0, STCC 0,100 0,128 0,085 0, STCC 0,0762 0,0972 0,083 0, STCC 0,0607 0,0774 0,082 0, Ambient temperature correction factors Ambient Temp C Rating factor Installation recoendations Minimum Bending Radius during Minimum Bending Radius Maximum Tensile Load During Minimum Installation Installation Fixed Installed Installation Temperature 15 x D 9 x D 50 N /² -20 C Subject to change without prior notice Page 46 of 212
48 Halogen-free, mud resistant MV power cable, RFOU 6/10(12)kV, P3/P10 Flame retardant halogen-free medium voltage (MV) cable. Mud resistant RFOU 6/10(12) kv EPR/EPR/TCWB/EVA NEK TS 606 CodeP3/P10 Operating temperature : 90 C Operating Voltage : 6/10(12) kv Standards applied Application Fixed installation for medium voltage (MV) power in both EXand safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009 IEC IEC class 2 IEC IEC IEC IEC IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned stranded and compressed copper (STCC), IEC class 2 Conductor screen Semiconductive layer (EP-rubber) semiconductive Insulation R EP-rubber, IEC (EPR) Insulation screen Semiconductive layer (EP-rubber) semicoductive Lay up / Shielding Cores are laid up together. Cores are identified by Brown, Black or Grey threads under and over the metallic screen on each conductor. Inner covering F Flame retardant and halogen-free thermoset compound Tape over inner PET tape covering Armour/screen O Tinned annealed copper wire braid Tape over armour/screen PET tape Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) Marking text E.g. "meter" "year" DRAKA 04 RFOU 6/10(12)KV P3/P10 3 x 95/50 2 IEC Manufacturing unit DRAKA 04 = Draka Industrial Cable, Germany Outer sheath colour Red Subject to change without prior notice Page 47 of 212
49 Range and dimensions Number of elements core, ² Electrical braid, ² Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Mechanical cross of the braid, ² Thickness Outer Sheath, outer sheath, Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) ± ,0 ± ± 22.0 ± ± 1, ± 1, ± ± ± ± ± ± ± ± ± ± ± ± 30.0 ± ± ± ± ± ± ± ± ± ± ± 46.0 ± ± 49.5 ± ± ± ± ± ± ± ± ± ± 66.5 ± ± ± ± 74.0 ± ± ± ± ± Ordering information New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No RFOU 6/10KV 1X 16/11² P3/P10 RED RFOU 6/10KV 1X 25/11² P3/P10 RED RFOU 6/10KV 1X 35/11² P3/P10 RED RFOU 6/10KV 1X 50/11² P3/P10 RED Yes RFOU 6/10KV 1X 70/16² P3/P10 RED Yes RFOU 6/10KV 1X 95/16² P3/P10 RED RFOU 6/10KV 1X 120/20² P3/P10 RED Yes RFOU 6/10KV 1X 150/19² P3/P10 RED RFOU 6/10KV 1X185/18² P3/P10 RED RFOU 6/10KV 1X 240/21² P3/P10 RED RFOU 6/10KV 1X 300/29² P3/P10 RED RFOU 6/10KV 1X 400/35² P3/P10 RED RFOU 6/10KV 1X 500/40² P3/P10 RED Subject to change without prior notice Page 48 of 212
50 New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No RFOU 6/10KV 1X 630/40² P3/P10 RED RFOU 6/10KV 3X 16/32² P3/P10 RED RFOU 6/10KV 3X 25/31² P3/P10 RED RFOU 6/10KV 3X 35/35² P3/P10 RED RFOU 6/10KV 3X 50/31² P3/P10 RED RFOU 6/10KV 3X 70/35² P3/P10 RED RFOU 6/10KV 3X 95/50² P3/P10 RED RFOU 6/10KV 3X 120/60² P3/P10 RED RFOU 6/10KV 3X 150/75² P3/P10 RED RFOU 6/10KV 3X 185/45² P3/P10 RED RFOU 6/10KV 3X 240/53² P3/P10 RED RFOU 6/10KV 3X 300/55² P3/P10 RED Electrical values power cables Number of elements core, ² Electrical braid, ² Conductor type 2 Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Capacitans per phase, nf/km Current rating IEC Table B.4, Ampere Short circuit rating 1 second, Ampere STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC dc / 670 ac STCC dc / 720 ac STCC dc / 780 ac STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC Ambient temperature correction factors Ambient Temp C Rating factor Installation recoendations Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation Installation Installed Installation Temperature 15 x D 9 x D 50 N /² -20 C Subject to change without prior notice Page 49 of 212
51 Halogen-free, mud resistant MV power cable, RFOU 8,7/15(17,5)kV, P4/P11 Flame retardant halogen-free medium voltage (MV) cable. Mud resistant RFOU 8,7/15(17,5) kv EPR/EPR/TCWB/EVA NEK TS 606 CodeP4/P11 Operating temperature : 90 C Operating Voltage : 8,7/15(17,5) kv Standards applied Application Fixed installation for medium voltage (MV) power in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009 IEC IEC class 2 IEC IEC IEC IEC IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned stranded and compressed copper (STCC), IEC class 2 Conductor screen Semiconductive layer (EP-rubber) semiconductive Insulation R EP-rubber, IEC (EPR) Insulation screen Semiconductive layer (EP-rubber) semicoductive Lay up / Shielding Cores are laid up together. Cores are identified by Brown, Black or Grey threads under and over the metallic screen on each conductor. Inner covering F Flame retardant and halogen-free thermoset compound Tape over inner PET tape covering Armour/screen O Tinned annealed copper wire braid Tape over armour/screen PET tape Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) Marking text E.g. "meter" "year" DRAKA 04 RFOU 8,7/15(17,5)KV P4/P11 1 x 300/29 2 IEC Manufacturing unit DRAKA 04 = Draka Industrial Cable, Germany Outer sheath colour Red Subject to change without prior notice Page 50 of 212
52 Range and dimensions Number of elements core, ² Electrical braid, ² Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Mechanical cross of the braid, ² Thickness Outer Sheath, outer sheath, Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) ± ± 24.0 ± 26.0 ± 28.0 ± 29.5 ± ± ± 35.0 ± ± ± ± ± ± ± ± 29.0 ± 30.5 ± 32.0 ± 34.5 ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± Ordering information New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No RFOU 8.7/15KV 1X 25/20² P4/P11 RED RFOU 8.7/15KV 1X 35/20² P4/P11 RED RFOU 8.7/15KV 1X 50/20² P4/P11 RED RFOU 8.7/15KV 1X 70/20² P4/P11 RED RFOU 8.7/15KV 1X 95/20² P4/P11 RED RFOU 8.7/15KV 1X 120/20² P4/P11 RED RFOU 8.7/15KV 1X150/20 P4/P11 RED RFOU 8.7/15KV 1X 185/20² P4/P11 RED RFOU 8.7/15KV 1X 240/25² P4/P11 RED RFOU 8.7/15KV 1X 300/29² P4/P11 RED RFOU 8.7/15KV 1X 400/30² P4/P11 RED RFOU 8.7/15KV 3X 25/35² P4/P11 RED RFOU 8.7/15KV 3X 35/35² P4/P11 RED RFOU 8.7/15KV 3X 50/40² P4/P11 RED RFOU 8.7/15KV 3X 70/40² P4/P11 RED RFOU 8.7/15KV 3X 95/55² P4/P11 RED RFOU 8.7/15KV 3X 120/60² P4/P11 RED RFOU 8.7/15KV 3X 150/80² P4/P11 RED Subject to change without prior notice Page 51 of 212
53 New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No RFOU 8.7/15KV 3X 185/95² P4/P11 RED RFOU 8.7/15KV 3X 240/95² P4/P11 RED RFOU 8.7/15KV 3X 300/95² P4/P11 RED Electrical values power cables Number of elements core, ² Electrical braid, ² Conductor type 2 Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Capacitans per phase, nf/km Current rating IEC Table B.4, Ampere Short circuit rating 1 second, Ampere STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC dc / 670 ac STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC Ambient temperature correction factors Ambient Temp C Rating factor Installation recoendations Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation Installation Installed Installation Temperature 15 x D 9 x D 50 N /² -20 C Subject to change without prior notice Page 52 of 212
54 Halogen-free, mud resistant MV power cable, RFOU 12/20(24)kV, P19/P21 Flame retardant halogen-free medium voltage (MV) cable. Mud resistant RFOU 12/20(24) kv EPR/EPR/TCWB/EVA NEK TS 606 CodeP19/P21 Operating temperature : 90 C Operating Voltage : 12/20(24) kv Standards applied Application Fixed installation for medium voltage (MV) power in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009 IEC IEC class 2 IEC IEC IEC IEC IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned stranded and compressed copper (STCC), IEC class 2 Conductor screen Semiconductive layer (EP-rubber) semiconductive Insulation R EP-rubber, IEC (EPR) Insulation screen Semiconductive layer (EP-rubber) semicoductive Lay up / Shielding Cores are laid up together. Cores are identified by Brown, Black or Grey threads under and over the metallic screen on each conductor. Inner covering F Flame retardant and halogen-free thermoset compound Tape over inner PET tape covering Armour/screen O Tinned annealed copper wire braid Tape over armour/screen PET tape Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) Marking text E.g. "meter" "year" DRAKA 04 RFOU 12/20(24)KV P19/P21 3 x 95/50 2 IEC Manufacturing unit DRAKA 04 = Draka Industrial Cable, Germany Outer sheath colour Red Subject to change without prior notice Page 53 of 212
55 Range and dimensions Number of elements core, ² Electrical braid, ² Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Mechanical cross of the braid, ² Thickness Outer Sheath, outer sheath, Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± 65.5 ± ± ± ± 73.5 ± ± ± ± 80.0 ± ± 85.0 ± ± 90.0 ± Ordering information New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No RFOU 12/20KV 1X 16/13² P19/P21 RED RFOU 12/20KV 1X 25/13² P19/P21 RED RFOU 12/20KV 1X 35/13² P19/P21 RED RFOU 12/20KV 1X 50/15² P19/P21 RED RFOU 12/20KV 1X 70/13² P19/P21 RED RFOU 12/20KV 1X 95/17² P19/P21 RED RFOU 12/20KV 1X120/15² P19/P21 RED RFOU 12/20KV 1X150/15² P19/P21 RED Yes RFOU 12/20KV 1X185/18² P19/P21 RED RFOU 12/20KV 1X240/23² P19/P21 RED RFOU 12/20KV 1X300/28² P19/P21 RED Yes RFOU 12/20KV 1X400/35² P19/P21 RED RFOU 12/20KV 3X 16/31² P19/P21 RED RFOU 12/20KV 3X 25/35² P19/P21 RED RFOU 12/20KV 3X 35/35² P19/P21 RED RFOU 12/20KV 3X 50/35² P19/P21 RED RFOU 12/20KV 3X 70/35² P19/P21 RED RFOU 12/20KV 3X 95/50² P19/P21 RED RFOU 12/20KV 3X120/60² P19/P21 RED RFOU 12/20KV 3X150/75² P19/P21 RED RFOU 12/20kV 3X 185/45² P19/P21 RED RFOU 12/20KV 3X240/55² P19/P21 RED Subject to change without prior notice Page 54 of 212
56 Electrical values power cables Number of elements core, ² Electrical braid, ² Conductor type 2 Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Capacitans per phase, nf/km Current rating IEC Table B.4, Ampere Short circuit rating 1 second, Ampere STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC 0,0475 0, dc / 670 ac STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC Ambient temperature correction factors Ambient Temp C Rating factor Installation recoendations Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation Installation Installed Installation Temperature 15 x D 9 x D 50 N /² -20 C Subject to change without prior notice Page 55 of 212
57 Halogen-free, mud resistant MV power cable, RFOU 18/30(36)kV, P20/P22 Flame retardant halogen-free medium voltage (MV) cable. Mud resistant RFOU 18/30(36) kv EPR/EPR/TCWB/EVA NEK 606 CodeP20/P22 Operating temperature : 90 C Operating Voltage : 18/30(36) kv Standards applied Application Fixed installation for medium voltage (MV) power in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. IEC IEC class 2 IEC IEC IEC IEC IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Conductor Code Letter Tinned stranded and compressed copper (STCC), IEC class 2 Conductor screen Semiconductive layer (EP-rubber) semiconductive Insulation R EP-rubber, IEC (EPR) Insulation screen Semiconductive layer (EP-rubber) semicoductive Lay up / Shielding Cores are laid up together. Cores are identified by Brown, Black or Grey threads under and over the metallic screen on each conductor. Inner covering F Flame retardant and halogen-free thermoset compound Tape over inner PET tape covering Armour/screen O Tinned annealed copper wire braid Tape over armour/screen PET tape Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) Marking text E.g. "meter" "year" DRAKA 04 RFOU 18/30(36)KV P20/P22 3x 120/60 2 IEC Manufacturing unit DRAKA 04 = Draka Industrial Cable, Germany Outer sheath colour Red Subject to change without prior notice Page 56 of 212
58 Range and dimensions Number of elements core, ² screen, ² Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Mechanical cross of the braid, ² Thickness Outer Sheath, outer sheath, Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) ,5 32.0± ± ,5 33,5±2,0 0, ,2 40,0± , ,5 35,0±2.0 0, ,2 42,0± , ± ± ,5 39,0±2.5 0, ,3 45,5± ± ± ,5 42.0± ± ,5 8,0 1,5 45,0±2,5 0, ,6 53,0+-3, ,8 65.0±2.5 0, ± ,8 70.0±2.5 0, ,7 80.5± ± ± ,0 78.0±2.5 0, ,0±4, Ordering information New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No RFOU 18/30KV 1x 50/25² P20/P22 RED RFOU 18/30KV 1x 70/30² P20/P22 RED RFOU 18/30KV 1x 95/30² P20/P22 RED RFOU 18/30KV 1x 120/20² P20/P22 RED RFOU 18/30KV 1x 150/ 30² P20/P22 RED RFOU 18/30KV 1x 185/ 30² P20/P22 RED RFOU 18/30KV 1x 240/40² P20/P22 RED RFOU 18/30KV 1x 300/35² P20/P22 RED RFOU 18/30KV 3x 35/45² P20/P22 RED RFOU 18/30KV 3x 70/85² P20/P22 RED RFOU 18/30KV 3x 95/90² P20/P22 RED RFOU 18/30KV 3x 120/95² P20/P22 RED Electrical values power cables Number of Conductor elements type 2 core, ² screen, ² Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Capacitans per phase, nf/km Current rating IEC Table B.4, Ampere Short circuit rating 1 second, Ampere STCC STCC STCC STCC STCC ,129 0, STCC STCC 0,0762 0, STCC STCC STCC ,126 0, STCC STCC Ambient temperature correction factors Ambient Temp C Rating factor Installation recoendations Minimum Bending Radius during Installation Minimum Bending Radius Fixed Installed Maximum Tensile Load During Installation Minimum Installation Temperature 15 x D 9 x D 50 N /² -20 C Subject to change without prior notice Page 57 of 212
59 Halogen-free, mud resistant, fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12 Fire resistant, flame retardant halogen-free power cable. Mud resistant BFOU 0,6/1(1,2)kV MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeP5/P12 Operating temperature : 90 C Operating Voltage : 0,6/1(1,2)kV Standards applied Application Fixed installation for power, control and lighting in both EX (Zone 0, 1 & 2)- and safe areas, emergency and critical systems where requirement for fire resistance exists. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009. IEC IEC class 2 IEC IEC IEC IEC IEC , -2, -21 IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation B Mica-tape + EP-rubber, IEC (EPR) Lay up / Shielding Cores laid up in concentric layers Inner covering F Flame retardant and halogen-free thermoplastic compound Tape over inner PET tape covering Armour/screen O Tinned annealed copper wire braid Tape over armour/screen PET tape Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) E.g. "meter" "year" DRAKA 01 BFOU 0,6/1kV P5/P12 3 x 25/16 2 FLEX - Marking text FLAME IEC *) or IEC *) IEC **) IEC Manufacturing unit DRAKA 01 = Draka Norsk Kabel Outer sheath colour Black *) IEC for cables with an overall diameter exceeding 20 and IEC for cables with an overall diameter not exceeding 20 **) IEC also at enhanced temperature 1000 C for 180 minutes Subject to change without prior notice Page 58 of 212
60 Core identification power cables Single core - Black Two cores - Blue - Brown Three cores - Brown - Black - Grey Four cores - Blue - Brown - Black - Grey Five cores - Blue - Brown - Black - Grey - Black Seven cores and above - White with black s Two cores + earth (3G) - Yellow/green - Blue - Brown Three cores + earth (4G) - Yellow/green - Brown - Black - Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC Ed Range and dimensions Number of elements core, ² Electrical braid, ² Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Mechanical cross of the braid, ² Thickness Outer Sheath, outer sheath, Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) ± ± ± 15.5 ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± 14.5 ± ± 15.5 ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± G G ± 1 ± G ± ± 15.5 ± 16.5 ± ± ± ± ± ± 16.5 ± ± ± ± ± ± ± ± ± ± ± ± 36.5 ± Subject to change without prior notice Page 59 of 212
61 Number of elements core, ² Electrical braid, ² Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Mechanical cross of the braid, ² Thickness Outer Sheath, outer sheath, Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 3G ± ± G ± 16.5 ± G ± ± G ± ± G ± ± ± ± ± ± ± ± ± 19.5 ± G ± ± G ± ± G ± 19.5 ± ± ± ± ± ± 19.5 ± G ± ± ± 19.5 ± 4G G ± ± ± ± ± ± ± ± G ± ± G ± ± G ± ± ± ± ± ± ± ± ± ± G ± ± G ± ± G ± ± ± ± ± ± ± ± G ± ± G ± ± G ± ± ± ± ± ± ± ± G ± ± G ± ± G ± ± Subject to change without prior notice Page 60 of 212
62 Number of elements core, ² Electrical braid, ² Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Mechanical cross of the braid, ² Thickness Outer Sheath, outer sheath, Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) ± ± ± 32.5 ± 34.5 ± ± G ± ± G ± ± G ± ± ± ± ± ± ± ± G ± 38.5 ± G ± ± G ± ± ± ± ± ± G ± ± G ± ± G ± ± ± ± ± ± G ± ± G ± ± G ± ± G ± ± Ordering information New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No BFOU 0.6/1kV 1X 16/4² P5/P12 BLACK BFOU 0.6/1kV 1X 25/6² P5/P12 BLACK BFOU 0.6/1kV 1X 35/6² P5/P12 BLACK BFOU 0.6/1kV 1X 50/10 P5/P12 BLACK BFOU 0.6/1kV 1X 70/10 P5/P12 BLACK BFOU 0.6/1kV 1X 95/10 P5/P12 BLACK Yes BFOU 0.6/1kV 1X 120/10 P5/P12 BLACK BFOU 0.6/1kV 1X 150/10 P5/P12 BLACK Yes BFOU 0.6/1kV 1X 185/10 P5/P12 BLACK Yes BFOU 0.6/1kV 1X 240/16 P5/P12 BLACK Yes BFOU 0.6/1kV 1X 300/16 P5/P12 BLACK Yes BFOU 0.6/1kV 2X /4 P5/P12 BLACK Yes BFOU 0.6/1kV 3X /6 P5/P12 BLACK Yes BFOU 0.6/1kV 4X /6 P5/P12 BLACK Yes BFOU 0.6/1kV 5X /6 P5/P12 BLACK BFOU 0.6/1kV 7X /6 P5/P12 BLACK Yes BFOU 0.6/1kV 12X /10 P5/P12 BLACK Yes BFOU 0.6/1kV 19X /10 P5/P12 BLACK Yes BFOU 0.6/1kV 27X /16 P5/P12 BLACK BFOU 0.6/1kV 32X /16 P5/P12 BLACK Subject to change without prior notice Page 61 of 212
63 New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No BFOU 0.6/1kV 37X /16 P5/P12 BLACK BFOU 0.6/1kV 3G ² P5/P12 BLACK BFOU 0.6/1kV 4G ² P5/P12 BLACK BFOU 0.6/1kV 5G ² P5/P12 BLACK BFOU 0.6/1kV 2X 2.5/6 P5/P12 BLACK Yes BFOU 0.6/1kV 3X 2.5/6 P5/P12 BLACK Yes BFOU 0.6/1kV 4X 2.5/6 P5/P12 BLACK Yes BFOU 0.6/1kV 5X 2.5/6 P5/P12 BLACK BFOU 0.6/1kV 7X 2.5/6 P5/P12 BLACK Yes BFOU 0.6/1kV 12X 2.5/10 P5/P12 BLACK BFOU 0.6/1kV 19X 2.5/16 P5/P12 BLACK BFOU 0.6/1kV 27X 2.5/16 P5/P12 BLACK BFOU 0.6/1kV 37X 2.5/25 P5/P12 BLACK BFOU 0.6/1kV 3G 2.5² P5/P12 BLACK Yes BFOU 0.6/1kV 4G 2.5² P5/P12 BLACK Yes BFOU 0.6/1kV 5G 2.5² P5/P12 BLACK BFOU 0.6/1kV 7G 2.5² P5/P12 BLACK BFOU 0.6/1kV 8G 2.5² P5/P12 BLACK BFOU 0.6/1kV 2X 4/6² P5/P12 BLACK Yes BFOU 0.6/1kV 3X 4/6² P5/P12 BLACK Yes BFOU 0.6/1kV 4X 4/6² P5/P12 BLACK Yes BFOU 0.6/1kV 5X 4/6² P5/P12 BLACK BFOU 0.6/1kV 3G 4² P5/P12 BLACK BFOU 0.6/1kV 4G 4² P5/P12 BLACK Yes BFOU 0.6/1kV 5G 4² P5/P12 BLACK BFOU 0.6/1kV 2X 6/6² P5/P12 BLACK Yes BFOU 0.6/1kV 3X 6/6² P5/P12 BLACK Yes BFOU 0.6/1kV 4X 6/6² P5/P12 BLACK Yes BFOU 0.6/1kV 3G 6² P5/P12 BLACK Yes BFOU 0.6/1kV 4G 6² P5/P12 BLACK BFOU 0.6/1kV 5G 6² P5/P12 BLACK BFOU 0.6/1kV 2X 10/10 P5/P12 BLACK Yes BFOU 0.6/1kV 3X 10/10 P5/P12 BLACK Yes BFOU 0.6/1kV 4X 10/10 P5/P12 BLACK Yes BFOU 0.6/1kV 3G 10² P5/P12 BLACK BFOU 0.6/1kV 4G 10² P5/P12 BLACK BFOU 0.6/1kV 5G 10² P5/P12 BLACK BFOU 0.6/1kV 2X 16/16 P5/P12 BLACK Yes BFOU 0.6/1kV 3X 16/16 P5/P12 BLACK Yes BFOU 0.6/1kV 4X 16/16 P5/P12 BLACK Yes BFOU 0.6/1kV 5X 16/16 P5/P12 BLACK BFOU 0.6/1kV 3G 16² P5/P12 BLACK BFOU 0.6/1kV 4G 16² P5/P12 BLACK BFOU 0.6/1kV 5G 16² P5/P12 BLACK BFOU 0.6/1kV 2X 25/16 P5/P12 BLACK BFOU 0.6/1kV 3X 25/16 P5/P12 BLACK Yes BFOU 0.6/1kV 4X 25/16 P5/P12 BLACK Yes BFOU 0.6/1kV 3G 25² P5/P12 BLACK BFOU 0.6/1kV 4G 25² P5/P12 BLACK BFOU 0.6/1kV 5G 25² P5/P12 BLACK BFOU 0.6/1kV 2X 35/16 P5/P12 BLACK BFOU 0.6/1kV 3X 35/16 P5/P12 BLACK Yes BFOU 0.6/1kV 4X 35/16 P5/P12 BLACK Yes BFOU 0.6/1kV 3G 35² P5/P12 BLACK BFOU 0.6/1kV 4G 35² P5/P12 BLACK BFOU 0.6/1kV 5G 35² P5/P12 BLACK Subject to change without prior notice Page 62 of 212
64 New Part Old Part Description Sheath Stock item EAN No. DNK EL No. Colour BFOU 0.6/1kV 2X 50/25 P5/P12 BLACK BFOU 0.6/1kV 3X 50/25 P5/P12 BLACK Yes BFOU 0.6/1kV 4X 50/25 P5/P12 BLACK BFOU 0.6/1kV 3G 50² P5/P12 BLACK BFOU 0.6/1kV 4G 50² P5/P12 BLACK BFOU 0.6/1kV 5G 50² P5/P12 BLACK BFOU 0.6/1kV 2X 70/35 P5/P12 BLACK BFOU 0.6/1kV 3X 70/35 P5/P12 BLACK Yes BFOU 0.6/1kV 4X 70/35 P5/P12 BLACK BFOU 0.6/1kV 5X 70/35 P5/P12 BLACK BFOU 0.6/1kV 3G 70² P5/P12 BLACK BFOU 0.6/1kV 4G 70² P5/P12 BLACK BFOU 0.6/1kV 5G 70² P5/P12 BLACK BFOU 0.6/1kV 2X 95/50 P5/P12 BLACK BFOU 0.6/1kV 3X 95/50 P5/P12 BLACK Yes BFOU 0.6/1kV 4X 95/50 P5/P12 BLACK Yes BFOU 0.6/1kV 3G 95² P5/P12 BLACK BFOU 0.6/1kV 4G 95² P5/P12 BLACK BFOU 0.6/1kV 5G 95² P5/P12 BLACK BFOU 0.6/1kV 3X 120/60 P5/P12 BLACK Yes BFOU 0.6/1kV 4X 120/60 P5/P12 BLACK BFOU 0.6/1kV 4G 120² P5/P12 BLACK BFOU 0.6/1kV 4G 150² P5/P12 BLACK BFOU 0.6/1kV 5G 150² P5/P12 BLACK BFOU 0.6/1kV 4G 185² P5/P12 BLACK Electrical values power cables Number of elements core, ² Electrical braid, ² Conductor type 2 Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere Short circuit rating 1 second, Ampere STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC G - STCC G - STCC G - STCC STCC STCC Subject to change without prior notice Page 63 of 212
65 Number of elements core, ² Electrical braid, ² Conductor type 2 Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere STCC STCC STCC STCC STCC STCC STCC G STCC G STCC G STCC G STCC G STCC STCC STCC STCC STCC G 4 - STCC G 4 - STCC G 4 - STCC STCC STCC STCC G 6 - STCC G 6 - STCC G 6 - STCC STCC STCC STCC G 10 - STCC G 10 - STCC G 10 - STCC STCC STCC STCC STCC G 16 - STCC G 16 - STCC G 16 - STCC STCC STCC STCC G 25 - STCC G 25 - STCC G 25 - STCC STCC STCC STCC G 35 - STCC G 35 - STCC G 35 - STCC STCC STCC STCC G 50 - STCC G 50 - STCC Subject to change without prior notice Page 64 of 212 Short circuit rating 1 second, Ampere
66 Number of elements core, ² Electrical braid, ² Conductor type 2 Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere 5G 50 - STCC STCC STCC STCC G 70 - STCC G 70 - STCC G 70 - STCC STCC STCC G 95 - STCC G 95 - STCC G 95 - STCC STCC STCC G STCC G STCC G STCC Short circuit rating 1 second, Ampere Ambient temperature correction factors Ambient Temp C Rating factor Installation recoendations Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation Installation Installed Installation Temperature 8 x D 6 x D 50 N /² -20 C Subject to change without prior notice Page 65 of 212
67 Halogen-free, mud resistant, fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12, double braided Fire resistant, flame retardant halogen-free power cable. Mud resistant. Double braided. BFOU 0,6/1(1,2)kV MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeP5/P12 Operating temperature : 90 C Operating Voltage : 0,6/1(1,2)kV Standards applied Application Fixed installation for power, control and lighting in both EX (Zone 0, 1 & 2)- and safe areas, emergency and critical systems where requirement for fire resistance exists. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009. IEC IEC class 2 IEC IEC IEC IEC IEC , -2, -21 IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation B Mica-tape + EP-rubber, IEC (EPR) Lay up / Shielding Cores laid up in concentric layers Inner covering F Flame retardant and halogen-free thermoplastic compound Tape over inner PET tape + rubberized Polyamide tape covering Armour/screen O Two layers of tinned copper wire braid (double braid) Tape over armour/screen PET tape + rubberized Polyamide tape Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) Marking text E.g. "meter" "year" DRAKA 01 BFOU 0,6/1kV P5/P12 3 x 25/16 2 FLEX - FLAME IEC *) or IEC *) IEC **) IEC Manufacturing unit DRAKA 01 = Draka Norsk Kabel Outer sheath Black colour *) IEC for cables with an overall diameter exceeding 20 and IEC for cables with an overall diameter not exceeding 20 **) IEC also at enhanced temperature 1000 C for 180 minutes Subject to change without prior notice Page 66 of 212
68 Core identification power cables Single core - Black Two cores - Blue - Brown Three cores - Brown - Black - Grey Four cores - Blue - Brown - Black - Grey Five cores - Blue - Brown - Black - Grey - Black Seven cores and above - White with black s Two cores + earth (3G) - Yellow/green - Blue - Brown Three cores + earth (4G) - Yellow/green - Brown - Black - Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC Ed Range and dimensions Number of elements core, ² Electrical braid, ² Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Mechanical cross of the braid, ² Thickness Outer Sheath, outer sheath, Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) ± ± ± ± ± ± ± ± ± ± ± ± ± ± Ordering information New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No BFOU 0.6/1kV 2X 150/75 P5/P12 BLACK BFOU 0.6/1kV 3X 150/75 P5/P12 BLACK Yes BFOU 0.6/1kV 4X 150/75 P5/P12 BLACK BFOU 0.6/1kV 3X 185/95 P5/P12 BLACK BFOU 0.6/1kV 4X 185/95 P5/P12 BLACK BFOU 0.6/1kV 2X 240/120 P5/P12 BLACK BFOU 0.6/1kV 3X 240/120 P5/P12 BLACK Electrical values power cables Number of elements core, ² Electrical braid, ² Conductor type Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere Short circuit rating 1 second, Ampere KGTFR KGTFR KGTFR KGTFR KGTFR KGTFR KGTFR Subject to change without prior notice Page 67 of 212
69 Ambient temperature correction factors Ambient Temp C Rating factor Installation recoendations Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation Installation Installed Installation Temperature 8 x D 6 x D 50 N /² -20 C Subject to change without prior notice Page 68 of 212
70 Halogen-free, mud resistant, fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12, large single core cables Fire resistant, flame retardant halogen-free power cable. Mud resistant. Single core cable. BFOU 0,6/1(1,2)kV MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeP5/P12 Operating temperature : 90 C Operating Voltage : 0,6/1(1,2)kV Application Fixed installation for power, control and lighting in both EX (Zone 0, 1 & 2)- and safe areas, emergency and critical systems where requirement for fire resistance exists. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009. Standards applied IEC IEC class 2 IEC IEC IEC IEC IEC , -2, -21 IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation B Mica-tape + EP-rubber, IEC (EPR) Lay up / Shielding Cores laid up in concentric layers Inner covering F Flame retardant and halogen-free thermoplastic compound Tape over inner PET tape covering Armour/screen O Tinned annealed copper wire braid Tape over armour/screen PET tape Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) Marking text E.g. "meter" "year" DRAKA 01 BFOU 0,6/1kV P5/P12 3 x 25/16 2 FLEX - FLAME IEC *) or IEC *) IEC **) IEC Manufacturing unit DRAKA 01 = Draka Norsk Kabel Outer sheath Black colour *) IEC for cables with an overall diameter exceeding 20 and IEC for cables with an overall diameter not exceeding 20 **) IEC also at enhanced temperature 1000 C for 180 minutes Subject to change without prior notice Page 69 of 212
71 Core identification power cables Single core - Black Two cores - Blue - Brown Three cores - Brown - Black - Grey Four cores - Blue - Brown - Black - Grey Five cores - Blue - Brown - Black - Grey - Black Seven cores and above - White with black s Two cores + earth (3G) - Yellow/green - Blue - Brown Three cores + earth (4G) - Yellow/green - Brown - Black - Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC Ed Range and dimensions Number of elements core, ² Electrical braid, ² Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Mechanical cross of the braid, ² Thickness Outer Sheath, outer sheath, Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) ± ± ± ± ± ± Ordering information New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No BFOU 0.6/1kV 1X 400/25 P5/P12 BLACK BFOU 0.6/1kV 1X 500/25 P5/P12 BLACK BFOU 0.6/1kV 1X 630/25 P5/P12 BLACK Electrical values power cables Number of elements core, ² Electrical braid, ² Conductor type 2 Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere Short circuit rating 1 second, Ampere STCC STCC STCC dc / 670 ac 780 dc / 720 ac 890 dc / 780 ac Ambient temperature correction factors Ambient Temp C Rating factor Installation recoendations Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation Installation Installed Installation Temperature 8 x D 6 x D 50 N /² -20 C Subject to change without prior notice Page 70 of 212
72 Halogen-free, mud resistant insulated conductor UX 1000V, P15 Flame retardant conductors UX 1000V Halogen-free, NEK TS 606 Type: P15 Maximum operating Conductor temperature : 90 C Operating voltage : 1000V Application Insulated conductor for earthing and bonding services. Mud resistant in accordance with NEK TS 606:2009. Standards applied IEC: & NEK TS 606:2009 IEC:60228 class 2 IEC: IEC: IEC: ,2 IEC: ,2 - Design guidelines - Conductor - Flame retardance - Flame retardance - Halogen-free properties - Smoke density CONSTRUCTION CODE LETTER Conductor Tinned, stranded copper, IEC class 2 PETP-tape. Insulation U Flame retardant halogen-free thermoset compound, HF90 (IEC ). Unsheathed X Marking E.g; meter year DRAKA NORSK KABEL UX 1000V P15 1x 95 ² IEC Colour Yellow/green Subject to change without prior notice Page 71 of 212
73 RANGE AND DIMENSIONS: UX 1000V Insulated conductor, P15 Conductor area (²) Conductor diameter approx. () Insulation thickness () over insulation () Weight of conductor approx. (kg/km) Copper content approx. (kg/km) 6 3,15 1,0 5,5±0, ,05 1,0 6,5±0, ,15 1,0 7,5±0, ,4 1,2 9,5±0, ,65 1,2 10,5±1, ,00 1,4 12,5±1, ,85 1,4 14,5±1, ,60 1,6 16,5±1, ,20 1,6 18,0±1, ,90 1,8 20,0±1, ,70 2,0 22,0±1, ,15 2,2 25,0±1, ,60 2,4 28,0±1, ,80 2,8 38,5±2, Electrical characteristics: Conductor area (²) Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Current rating IEC Table B.4, Ampere Short circuit rating at 1 second, Ampere dc / 780 ac Installation recoendations: In accordance with IEC Minimum bending radius Maximum pulling tension Minium installation temperature During installation Fixed installed 25N x total cross of conductors - 20 C 8 x cable diameter 6 x cable diameter Subject to change without prior notice Page 72 of 212
74 Ordering information: New Part Old Part Conductor area (²) Stock item El- (Norway only) Yes Yes Yes Yes Yes Yes Yes Yes Subject to change without prior notice Page 73 of 212
75 Halogen-free, fire resistant, unarmoured, mud resistant power cable, BU 0,6/1(1,2)kV, P17 Fire resistant, flame retardant halogen-free power cable. Mud resistant BU 0,6/1(1,2)kV MGT/EPR/EVA NEK TS 606 CodeP17 Operating temperature : 90 C Operating Voltage : 0,6/1(1,2)kV Application Fixed installation for power, control and lighting in safe areas, emergency and critical systems where requirement for fire resistance exists. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009. These cables are double-insulated and Single core cables are used as battery cables. Standards applied IEC IEC class 2 IEC IEC IEC IEC IEC IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation B Mica-tape + EP-rubber, IEC (EPR) Lay up / Shielding Cores laid up in concentric layers Inner covering No inner covering. (Additional tapes may be applied) Armour/screen No armour. Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) Marking text E.g. "meter" "year" DRAKA 01 BU 0,6/1kV P17 1 x 70 2 IEC IEC Manufacturing unit DRAKA 01 = Draka Norsk Kabel, Outer sheath Black colour Subject to change without prior notice Page 74 of 212
76 Core identification power cables Single core Black Two cores - Blue Brown Three cores - Brown - Black Grey Four cores - Blue - Brown - Black Grey Five cores - Blue - Brown - Black - Grey Black Seven cores and above - White with black s Two cores + earth (3G) - Yellow/green - Blue Brown Three cores + earth (4G) - Yellow/green - Brown - Black - Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC Ed Range and dimensions Number of elements core, ² Conductor, Insulation Thickness, Thickness Outer Sheath, outer sheath, Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± G ± G ± ± ± ± ± ± G ± G ± G ± ± G ± G ± ± ± G ± G ± ± ± G ± ± G ± ± G ± Subject to change without prior notice Page 75 of 212
77 Number of Conductor Insulation Thickness Outer outer Weight of Cable Copper content elements core, ², Thickness, Sheath, sheath, Approx. (Kg/Km) Approx. (kg/km) ± G ± ± ± G ± Ordering information New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No BU 0.6/1kV 1X 10² P17 BLACK BU 0.6/1kV 1X 16² P17 BLACK BU 0.6/1kV 1X 25² P17 BLACK BU 0.6/1kV 1X 35² P17 BLACK BU 0.6/1kV 1X 50² P17 BLACK BU 0.6/1kV 1X 70² P17 BLACK BU 0.6/1kV 1X 95² P17 BLACK BU 0.6/1kV 1X 120² P17 BLACK BU 0.6/1kV 1X 150² P17 BLACK BU 0.6/1kV 1X 185² P17 BLACK BU 0.6/1kV 1X 240² P17 BLACK BU 0.6/1kV 2X ² P17 BLACK BU 0.6/1kV 3X ² P17 BLACK BU 0.6/1kV 7X ² P17 BLACK BU 0.6/1kV 19X ² P17 BLACK BU 0.6/1kV 3G ² P17 BLACK BU 0.6/1kV 7G ² P17 BLACK BU 0.6/1kV 2X 2.5² P17 BLACK BU 0.6/1kV 3X 2.5² P17 BLACK BU 0.6/1kV 7X 2.5² P17 BLACK BU 0.6/1kV 12X 2.5² P17 BLACK BU 0.6/1kV 19X 2.5² P17 BLACK BU 0.6/1kV 3G 2.5² P17 BLACK Yes BU 0.6/1kV 4G 2.5² P17 BLACK BU 0.6/1kV 5G 2.5² P17 BLACK BU 0,6/1KV 3X 4 MM2 P17 BLACK BU 0.6/1kV 3G 4² P17 BLACK BU 0.6/1kV 4G 4² P17 BLACK BU 0,6/1KV 2X 6 MM2 P17 BLACK BU 0.6/1kV 3X 6² P17 BLACK BU 0.6/1kV 4G 6² P17 BLACK BU 0.6/1kV 5G 6² P17 BLACK BU 0.6/1kV 2X 10² P17 BLACK BU 0.6/1kV 3X 10² P17 BLACK BU 0.6/1kV 4G 10² P17 BLACK BU 0.6/1kV 3X 16² P17 BLACK BU 0.6/1kV 4G 16² P17 BLACK BU 0.6/1kV 3X 25² P17 BLACK BU 0.6/1kV 3G 25² P17 BLACK BU 0,6/1KV 3X 35 ² P17 BLACK Subject to change without prior notice Page 76 of 212
78 New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No BU 0.6/1kV 4G 35² P17 BLACK BU 0,6/1KV 3X 50 ² P17 BLACK BU 0,6/1KV 3X 150 ² P17 BLACK BU 0.6/1kV 4G 150² P17 BLACK Electrical values power cables Number of elements core, ² Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere Short circuit rating 1 second, Ampere G G G G G G G G G G G G Subject to change without prior notice Page 77 of 212
79 Number of elements core, ² Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere 4G G Short circuit rating 1 second, Ampere Ambient temperature correction factors Ambient Temp C Rating factor Installation recoendations Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation Installation Installed Installation Temperature 8 x D 6 x D 50 N /² -20 C Subject to change without prior notice Page 78 of 212
80 Halogen-free, unarmoured, mud resistant power cable, RU 0,6/1(1,2)kV, P18 Flame retardant halogen-free power cable. Mud resistant RU 0,6/1(1,2)kV EPR/EVA NEK TS 606 CodeP18 Operating temperature : 90 C Operating Voltage : 0,6/1(1,2)kV Application Fixed installation for power,control and lighting in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the OIL & MUD resistance requirement in NEK TS 606:2009. These cables are double-insulated and Single core cables are used as battery cables. Standards applied IEC IEC class 2 IEC IEC IEC IEC IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation R EP-rubber, IEC (EPR) Lay up / Shielding Cores laid up in concentric layers Inner covering No inner covering. (Additional tapes may be applied) Armour/screen No armour. Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) Marking text E.g. "meter" "year" DRAKA 01 RU 0,6/1KV P18 3 x 2,5 2 IEC Manufacturing unit DRAKA 01 = Draka Norsk Kabel, Outer sheath Black colour Subject to change without prior notice Page 79 of 212
81 Core identification power cables Single core Black Two cores - Blue Brown Three cores - Brown - Black Grey Four cores - Blue - Brown - Black Grey Five cores - Blue - Brown - Black - Grey Black Seven cores and above - White with black s Two cores + earth (3G) - Yellow/green - Blue Brown Three cores + earth (4G) - Yellow/green - Brown - Black - Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC Ed Range and dimensions Number of elements core, ² Conductor, Insulation Thickness, Thickness Outer Sheath, outer sheath, Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± G ± G ± G ± G ± ± ± ± ± ± G ± G ± G ± ± ± ± G ± G ± G ± ± ± ± G ± G ± G ± ± ± Subject to change without prior notice Page 80 of 212
82 Number of elements core, ² Conductor, Insulation Thickness, Thickness Outer Sheath, outer sheath, Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 4G ± G ± ± ± ± G ± G ± G ± ± ± ± G ± ± ± G ± G ± ± G ± ± G ± Ordering information New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No RU 0.6/1kV 1X 25² P18 BLACK RU 0.6/1kV 1X 50² P18 BLACK RU 0,6/1KV 1X 70 MM2 P18 BLACK RU 0.6/1kV 1X 95² P18 BLACK RU 0.6/1kV 1X 120² P18 BLACK RU 0.6/1kV 1X 150² P18 BLACK RU 0.6/1kV 1X 185² P18 BLACK RU 0.6/1kV 1X 240² P18 BLACK RU 0.6/1kV 1X 300² P18 BLACK RU 0.6/1kV 2X ² P18 BLACK RU 0.6/1kV 3X ² P18 BLACK RU 0.6/1kV 4X ² P18 BLACK RU 0.6/1kV 5X ² P18 BLACK RU 0.6/1kV 7X ² P18 BLACK RU 0.6/1kV 12X ² P18 BLACK RU 0.6/1kV 19X ² P18 BLACK RU 0,6/1KV 24X 1,5 MM2 P18 BLACK RU 0.6/1kV 3G ² P18 BLACK RU 0.6/1kV 4G ² P18 BLACK RU 0.6/1kV 5G ² P18 BLACK RU 0.6/1kV 7G ² P18 BLACK RU 0.6/1kV 2X 2.5² P18 BLACK RU 0.6/1kV 3X 2.5² P18 BLACK RU 0,6/1KV 4X 2,5 MM2 P18 BLACK RU 0.6/1kV 5X 2.5² P18 BLACK RU 0.6/1kV 7X 2.5² P18 BLACK RU 0.6/1kV 3G 2.5² P18 BLACK RU 0.6/1kV 4G 2.5² P18 BLACK RU 0.6/1kV 5G 2.5² P18 BLACK Subject to change without prior notice Page 81 of 212
83 New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No RU 0.6/1kV 2X 4² P18 BLACK RU 0.6/1kV 3X 4² P18 BLACK RU 0,6/1KV 4X 4 MM2 P18 BLACK RU 0.6/1kV 3G 4² P18 BLACK RU 0.6/1kV 4G 4² P18 BLACK RU 0,6/1KV 5G 4² P18 BLACK RU 0,6/1KV 2X 6 MM2 P18 BLACK RU 0.6/1kV 3X 6² P18 BLACK RU 0.6/1kV 4X 6² P18 BLACK RU 0.6/1kV 3G 6² P18 BLACK RU 0.6/1kV 4G 6² P18 BLACK RU 0.6/1kV 5G 6² P18 BLACK RU 0,6/1KV 2X 10 MM2 P18 BLACK RU 0.6/1kV 3X 10² P18 BLACK RU 0.6/1kV 4G 10² P18 BLACK RU 0.6/1kV 5G 10² P18 BLACK RU 0.6/1kV 2X 16² P18 BLACK RU 0.6/1kV 3X 16² P18 BLACK RU 0,6/1KV 4X 16 MM2 P18 BLACK RU 0.6/1kV 3G 16² P18 BLACK RU 0.6/1kV 4G 16² P18 BLACK RU 0.6/1kV 5G 16² P18 BLACK RU 0.6/1kV 2X 25² P18 BLACK RU 0.6/1kV 3X 25² P18 BLACK RU 0,6/1KV 4X 25 MM2 P18 BLACK RU 0.6/1kV 4G 25² P18 BLACK RU 0,6/1KV 2X 35 MM2 P18 BLACK RU 0.6/1kV 3X 35² P18 BLACK RU 0.6/1kV 4G 35² P18 BLACK RU 0.6/1kV 5G 35² P18 BLACK RU 0.6/1kV 3X 50² P18 BLACK RU 0.6/1kV 5G 50² P18 BLACK RU 0.6/1kV 3X 70² P18 BLACK RU 0.6/1kV 5G 70² P18 BLACK Electrical values power cables Number of elements core, ² Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere Short circuit rating 1 second, Ampere Subject to change without prior notice Page 82 of 212
84 Number of elements core, ² Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere G G G G G G G G G G G G G G G G G G G G G G G Short circuit rating 1 second, Ampere Subject to change without prior notice Page 83 of 212
85 Ambient temperature correction factors Ambient Temp C Rating factor Installation recoendations Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation Installation Installed Installation Temperature 8 x D 6 x D 50 N /² -20 C Subject to change without prior notice Page 84 of 212
86 Cable for Variable Frequency Drives (VFD s), RFOU-VFD 0,6/1(1,8/3)kV with flexible conductors class 5 and separate earth cores Flame retardant cables RFOU-VFD 0,6/1 (1,8/3)kV Power cable for variable frequency drives Class 5 conductors Halogen free and Mud resistant Maximum operating conductor temperature : 90 C Operating voltage : 0,6/1(1,2)kV Application Special cable for Variable Frequency Drives / Azimuth motors up to 1kV. Suitable for voltage peaks up to 3600V. Armoured cable for fixed installations in ships and offshore units. Can be installed and operated both indoors and outdoors. Oil and MUD resistant to NEK606. Standards applied IEC IEC class 5 IEC IEC IEC IEC IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke CONSTRUCTION CODE LETTER Conductor Tinned, annealed, flexible copper, IEC class 5. Insulation R EP-rubber, IEC (EPR) Lay up 3 insulated phase-conductors are laid up with 3 insulated earth conductors. Bedding F Flame retardant halogen-free thermoset compound Armour O Cu/PETP-tape Tinned copper wire braid. Shield coverage is 100% PETP-tape Outer sheath U Flame retardant halogen-free thermoset compound, SHF2 (IEC ). Marking Colour E.g; meter DRAKA 01 RFOU VFD 0,6/1(1,8/3)kV x 16 ² IEC Black or Yellow Subject to change without prior notice Page 85 of 212
87 Core identification: The three main power cores: All three Earth cores: Brown Black Grey Yellow/green RANGE AND DIMENSIONS No. of Cond. Insulation cores and diam. thickness cond. appr. area ² Ø RFOU-VFD 0,6/1(1,8/3) kv Thickness Armour/ of over screen bedding bedding wire approx. diameter Ø Ø Thickness of outer sheath, nominal overall Ø Weight of cable kg/km Copper content Approx. (kg/km) 3x x ± 1, ,0 ± 1, x x 6 7,2 3,3 2, ,6 28,5±1,0 0,30 1,8 33,5±1, x x 6 8,45 3,3 2,2 1, ± ± x x 10 10,65 4,3 2,4 1,0 1,6 36,0±1,5 0,30 2,0 41,5±2, x x 16 14, ,4 1,0 1,6 45,0±2,0 0,40 2,3 51,0±2, x x 25 14,3 7,2 2,4 1,2 1,6 45.5±2,0 0,4 2,3 52±2, x x 25 16,6 7,2 2,4 1,2 1,8 50,0±2,5 0,40 2,5 57,0±2, x x 16 18,1 5,9 2,4 1,0 1,8 53,5±2,5 0,40 2,6 60,5±3, x x 25 3x x 35 18,1 2,4 1,0 18,1 2,4 1,2 1,8 53,5 ± 2,5 0,40 2,6 60,5 ± 3, ,8 53,5 ± 2,5 0,40 2,6 60,5 ± 3, x x 16 19,9 5,9 2,4 1,0 1,8 57,5±2,5 0,40 2,7 65,0±3, Tba = to be agreed in case of an order Ordering information New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No. RFOU-VFD 1kV(3kV) 3x 10 ² + 3x 4 ² YELLOW RFOU-VFD 1kV(3kV) 3x 10 ² + 3x 4 ² BLACK RFOU-VFD 1kV(3kV) 3x 25 ² + 3x 6 ² YELLOW RFOU-VFD 1kV(3kV) 3x 25 ² + 3x 6 ² BLACK - - RFOU-VFD 1kV(3kV) 3x 35 ² + 3x 6 ² BLACK RFOU-VFD 1kV(3kV) 3x 35 ² + 3x 6 ² YELLOW RFOU-VFD 1kV(3kV) 3x 50 ² + 3x 10 ² YELLOW RFOU-VFD 1kV(3kV) 3x 50 ² + 3x 10 ² BLACK RFOU-VFD 1kV(3kV) 3x 95 ² + 3x 16 ² YELLOW RFOU-VFD 1kV(3kV) 3x 95 ² + 3x 16 ² BLACK RFOU-VFD 1kV(3kV) 3x 95 ² + 3x 25 ² YELLOW RFOU-VFD 1kV(3kV) 3x 95 ² + 3x 25 ² BLACK RFOU-VFD 1kV(3kV) 3x 120 ² + 3x 25 ² YELLOW RFOU-VFD 1kV(3kV) 3x 120 ² + 3x 25 ² BLACK RFOU-VFD 1kV(3kV) 3x 150 ² + 3x 16 ² YELLOW RFOU-VFD 1kV(3kV) 3x 150 ² + 3x 16 ² BLACK Subject to change without prior notice Page 86 of 212
88 New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No. RFOU-VFD 1kV(3kV) 3x 150 ² + 3x 25 ² YELLOW RFOU-VFD 1kV(3kV) 3x 150 ² + 3x 25 ² BLACK RFOU-VFD 1kV(3kV) 3x 150 ² + 3x 35 ² YELLOW RFOU-VFD 1kV(3kV) 3x 150 ² + 3x 35 ² BLACK RFOU-VFD 1kV(3kV) 3x 185 ² + 3x 16 ² YELLOW RFOU-VFD 1kV(3kV) 3x 185 ² + 3x 16 ² BLACK Electrical values power cables No. of cores and cond. area ² Resistance at 20 C ohm/km Resistance at 90 C ohm/km Reactance at 50Hz Ohm/km Current rating at 45 C Ampere Short curcuit rating 1 sec. Ampere 3x x 4 1,95 5,09 2,49 6,49 0, x x 6 0,795 3,39 1,014 4,323 0, x x 6 0,565 3,39 0,668 4,323 0, x x 10 0,393 1,95 0,501 2,486 0, x x 16 0,210 1,24 0,268 1,58 0, x x 25 0,210 0,795 0,268 1,014 0, x x 25 0,164 0,795 0,209 1,014 0, x x 16 0,132 1,24 0,1683 1,58 0, x x 25 0,132 0,795 0,1683 1,013 0, x x 35 0,132 0,565 0,1683 0,7204 0, x x 16 0,108 1,24 0,1683 1,58 0, Ambient temperature correction factors Ambient Temp C Rating factor Installation recoendations Minimum Bending Radius during Installation Minimum Bending Radius Maximum Tensile Load During Fixed Installed Installation 8 x D 6 x D 50 N /² -20 C Minimum Installation Temperature Subject to change without prior notice Page 87 of 212
89 Cable for Variable Frequency Drives (VFD s), RFOU-VFD 0,6/1(1,8/3)kV with stranded conductors class 2 and tinned copper wire braid as earth Flame retardant cables RFOU-VFD 0,6/1kV(1,8/3kV) EPR/EPR/TCWB/EVA Halogen-free, Mud resistant Maximum operating Conductor temperature Operating voltage : 90 O C : 0,6/1kV (3 kv) Application Standards applied Special cable for Variable Frequency Drives / Azimuth motors up to 1kV. Suitable for voltage peaks up to 3600V. Armoured cable for fixed installations in ships and offshore units. Can be installed and operated both indoors and outdoors. Oil and MUD resistant to NEK606. IEC IEC class 2 IEC IEC IEC IEC IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free IEC ,2 - Low Smoke CONSTRUCTION CODE LETTER Conductor Circular, tinned, stranded copper. IEC Class 2 (1) Insulation R EP-rubber (2) Bedding F Flame retardant and halogen-free thermoset compound. (3) Armour O Cu/PETP-tape. (4) Tinned copper wire braid. (5) Shield coverage is 100% PETP-tape. (6) Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2.(7) Marking E.g; meter year DRAKA 01 RFOU-VFD 0,6/1kV (1,8/3) kv 3x 95/50 ² IEC Colour Yellow or Black Core identification: Three cores: Brown Black - Grey Subject to change without prior notice Page 88 of 212
90 RANGE AND DIMENSIONS: RFOU-VFD 0,6/1kV (1,8/3)kV No. of cores and cond. area (²) Cond. diam. appr. (Ø) Insulation thickness () Thickness of inner covering, bedding (Ø) of armour /shield wire (Ø) Thickness outer sheath, outer sheath (Ø) Weight of cable approx (kg/km) Copper content Approx. (kg/km) 3x 2.5/ ± ± x 4/ ± ± x 6/10 3, ± ± x 10/10 4, ± ± x 16/16 5,15 2, ± ± x 25/16 6, ± ± x 50/25 9, ± ± x 70/ ± ± x 95/50 12,60 2,4 2,0 42 ± 2, ,3 49 ± x 120/ ± ± x 150/ ± 2,0 2 layer 2, ± 2, x 185/ ± layer ± x 240/ ± layer ± Ordering information New Part Old Part Description Sheath Colour Stock item EAN No. DNK EL No. RFOU-VFD 1kV(3kV) 3x 2.5/10 ² BLACK RFOU-VFD 1kV(3kV) 3x 4/10 ² BLACK RFOU-VFD 1kV(3kV) 3x 6/10 ² BLACK RFOU-VFD 1kV(3kV) 3x 10/10 ² BLACK RFOU-VFD 1kV(3kV) 3x 16/16 ² YELLOW RFOU-VFD 1kV(3kV) 3x 16/16 ² BLACK RFOU-VFD 1kV(3kV) 3x 25/16 ² YELLOW RFOU-VFD 1kV(3kV) 3x 50/25 ² YELLOW RFOU-VFD 1kV(3kV) 3x 70/35 ² BLACK RFOU-VFD 1kV(3kV) 3x 95/50 ² BLACK RFOU-VFD 1kV(3kV) 3x 120/60 ² YELLOW RFOU-VFD 1kV(3kV) 3x 150/70 ² BLACK RFOU-VFD 1kV(3kV) 3x 185/95 ² YELLOW RFOU-VFD 1kV(3kV) 3x 240/120 ² BLACK Electrical characteristics No. of cores and cond. area (²) Resistance at 20 C (ohm/km) Resistance at 90 C (ohm/km) Reactance at 50Hz (ohm/km) Current rating at 45 C (ampere) Short curcuit rating, 1 sec (ampere) 3x 2.5/ x 4/ x 6/ x 10/ x 16/16 1, x 25/ x 50/ x 70/ x 95/50 0, x 120/ x 150/ x 185/ x 240/ Subject to change without prior notice Page 89 of 212
91 Correction factors for different ambient temperatures: Ambient temp. C Rating factors 1,22 1,17 1,12 1,06 1,00 0,94 0,87 0,79 0,71 0,61 0,5 Installation recoendations: In accordance with IEC Minimum bending radius Maximum pulling tension Minium installation During installation Fixed installed 8 x cable diameter 6 x cable diameter 50N x total of conductors temperature - 20 C Subject to change without prior notice Page 90 of 212
92 Fire resistant optical fibre cable, QFCI-I/O/RM-JM/-, F1 QFCI-I/O/RM-JM/- Indoor and outdoor. Fire resistant Flame retardant halogen-free Loose tube NEK 606 Code F1 Optical cable for indoor and outdoor use in vital counication and emergency systems that need to be operational during fire. The cable has a patented design that ensures operation for more than 3 hours in fires up to 1000ºC. The cable is halogen free and flame retardant to protect against secondary damage to electronic equipment during and after fire. Outer sheath is made from black UV-stabilized and weather resistant material and may be exposed for shorter periods to fluids such as diesel and mineral oils. The resistance to these fluids is according to IEC The cable is reinforced with a steel wire braiding. The fibres are protected in jelly filled loose tubes stranded around a central strength member to ensure optimum performance and long life. Each fibre and loose tube is colour coded for easy identification during splicing and termination. The outer sheath is marked to show fibre type and cable type. The sheath colour is BLACK. Fibres in mica wrapped loose tube Steel strength element Wrapping Inner sheath Filler Steel wire braiding Outer sheath Weight and dimensions Number of Number of fibres fibres in each tube Number of tubes + fillers Loose tube diameter () Outer diameter () Weight Heat release (kg/km) (MJ/km) Other fibre counts are available on request. Cable properties Tensile strength (IEC E1) Max tensile load during installation Max tensile load during operation 1500 N 500 N Chemical reistance Mineral oils IRM 902 (IEC ) Diesel - IRM 903 (IEC ) Crush (IEC E3) 3000 N/10cm Fire and smoke classifications - 7 days/23 C - 4 hours/70 C - 7 days/23 C - 4 hours/70 C Impact (IEC E4) 30J IEC (750 C, 90 minutes) <1.0 db excess loss Torsion (IEC E7) Cable bending Minimum bending diameter Cable bend (IEC E11) Temperature window Operation Installation Storage 1 turn/1m 250 <0.1dB/ 5 turn -40 C to +70 C -10 C to +70 C -40 C to +70 C Upgraded IEC (1000 C, 3 hours) BP GS Clause7.1 IEC IEC (Cat. A) IEC (Cat. C) IEC IEC < db excess loss Subject to change without prior notice Page 91 of 212
93 Ordering information Part no Number of fibres Cabe Type Fiber type Stock Item Fiber data sheet G8-9/125 QFCI-I/O/RM-JM/- OS2 Single mode - C03e G12-9/125 QFCI-I/O/RM-JM/- OS2 Single mode Yes C03e G24-9/125 QFCI-I/O/RM-JM/- OS2 Single mode Yes C03e G48-9/125 QFCI-I/O/RM-JM/- OS2 Single mode Yes C03e G4-50/125 QFCI-I/O/RM-JM/- OM2 50/125 multi mode - C G12-50/125 QFCI-I/O/RM-JM/- OM2 50/125 multi mode - C G24-50/125 QFCI-I/O/RM-JM/- OM2 50/125 multi mode - C G48-50/125 QFCI-I/O/RM-JM/- OM2 50/125 multi mode - C G4-50/125OM3 QFCI-I/O/RM-JM/- OM3 MaxCap-OM3 - C G12-50/125OM3 QFCI-I/O/RM-JM/- OM3 MaxCap-OM3 - C G24-50/125OM3 QFCI-I/O/RM-JM/- OM3 MaxCap-OM3 - C G48-50/125OM3 QFCI-I/O/RM-JM/- OM3 MaxCap-OM3 - C G4-62.5/125 QFCI-I/O/RM-JM/- OM1 62.5/125 multi mode Yes C G8-62.5/125 QFCI-I/O/RM-JM/- OM1 62.5/125 multi mode Yes C G /125 QFCI-I/O/RM-JM/- OM1 62.5/125 multi mode Yes C G /125 QFCI-I/O/RM-JM/- OM1 62.5/125 multi mode Yes C G /125 QFCI-I/O/RM-JM/- OM1 62.5/125 multi mode - C02 Colour codes Fibre Colour Tube Colour 1 White 1 Red 2 Red 2 Green 3 Yellow 3 White 4 Green 4 White 5 Blue 5 White 6 Grey 6 White 7 Brown 8 Black We reserve the right to alter this specification without notice. Other fibre types and qualities are available on request. Subject to change without prior notice Page 92 of 212
94 Fire resistant optical fibre cable, QFCI-I/O/RM/C-JM/-, MUD PROTECTED (F5) QFCI-I/O/RM/C-JM/- Indoor and outdoor. Fire resistant Flame retardant halogen-free Loose tube NEK 606 Code (F5) Optical cable for indoor and outdoor use in vital counication and emergency systems that need to be operational during fire. The cable has a patented design that ensures operation for more than 3 hours in fires up to 1000ºC. The cable is halogen free and flame retardant to protect against secondary damage to electronic equipment during and after fire. Outer sheath(1) is made from black UV-stabilized and weather resistant material and may be exposed for shorter periods to fluids such as diesel and mineral oils. The resistance to these fluids is according to IEC The cable is reinforced with a steel wire braiding. The fibres are protected in jelly filled loose tubes stranded around a central strength member to ensure optimum performance and long life. Each fibre and loose tube is colour coded for easy identification during splicing and termination. The outer sheath is marked to show fibre type and cable type. An additional outer sheath is added for improved oil- and MUD protection. The sheath colour is GREY. Fibres in mica wrappe loose tube Steel strength elemen Wrapping Inner sheath Filler Steel wire braiding Outer sheath (1) Outer sheath (MUD) Weight and dimensions Number of Number of fibres fibres in each tube Number of tubes + fillers Loose tube diameter () Outer diameter () Weight Heat release (Estimated) (MJ/km) (kg/km) Other fibre counts are available on request. Cable properties Tensile strength (IEC E1) Max tensile load during installation Max tensile load during operation 1500 N 500 N Chemical resistance Mineral oils IRM 902 (IEC ) Diesel - IRM 903 (IEC ) - 7 days/100 C - 7 days/100 C Crush (IEC E3) 3000 N/10cm Fire and smoke classifications Impact (IEC E4) 30J IEC (750 C, 90 minutes) <1.0 db excess loss Torsion (IEC E7) 1 turn/1m Upgraded IEC (1000 C, 3 hours) < db excess loss Cable bending Minimum bending diameter Cable bend (IEC E11) 250 <0.1dB/ 5 turn BP GS Clause7.1 IEC IEC (Cat. A) IEC (Cat. C) Temperature window Operation Installation Storage -40 C to +70 C -10 C to +70 C -40 C to +70 C IEC Subject to change without prior notice Page 93 of 212
95 Ordering information Part no Number of fibres Cabe Type Fiber type Stock Item Fiber data sheet G8-9/125 QFCI-I/O/RM/C-JM/- OS2 Single mode C03e G12-9/125 QFCI-I/O/RM/C-JM/- OS2 Single mode C03e G24-9/125 QFCI-I/O/RM/C-JM/- OS2 Single mode C03e G48-9/125 QFCI-I/O/RM/C-JM/- OS2 Single mode C03e G8-50/125 QFCI-I/O/RM/C-JM/- OM2 50/125 multi mode C G12-50/125 QFCI-I/O/RM/C-JM/- OM2 50/125 multi mode C G24-50/125 QFCI-I/O/RM/C-JM/- OM2 50/125 multi mode C23 48 G48-50/125 QFCI-I/O/RM/C-JM/- OM2 50/125 multi mode C23 12 G12-50/125OM3 QFCI-I/O/RM/C-JM/- OM3 MaxCap-OM3 C31 24 G24-50/125OM3 QFCI-I/O/RM/C-JM/- OM3 MaxCap-OM3 C31 48 G48-50/125OM3 QFCI-I/O/RM/C-JM/- OM3 MaxCap-OM3 C G4-62.5/125 QFCI-I/O/RM/C-JM/- OM1 62.5/125 multi mode C G8-62.5/125 QFCI-I/O/RM/C-JM/- OM1 62.5/125 multi mode C G /125 QFCI-I/O/RM/C-JM/- OM1 62.5/125 multi mode C G /125 QFCI-I/O/RM/C-JM/- OM1 62.5/125 multi mode C G /125 QFCI-I/O/RM/C-JM/- OM1 62.5/125 multi mode C02 Colour codes Fibre Colour Tube Colour 1 White 1 Red 2 Red 2 Green 3 Yellow 3 White 4 Green 4 White 5 Blue 5 White 6 Grey 6 White 7 Brown 8 Black Standard colur on outer sheet is Grey We reserve the right to alter this specification without notice. Other fibre types and qualities are available on request. Subject to change without prior notice Page 94 of 212
96 Flame retardant optical fibre cable, AICI-I/O/RM-W, F6 AICI-I/O/RM-W Indoor and outdoor Flame retardant and halogen free Steel wire braiding Tight buffer NEK 606 Code F6 Optical cable for industrial environments. The cable is suitable for both indoor and outdoor installation. The outer sheath is made from black UV-stabilized and weather resistant material which is SHF1 classified, and may be exposed for shorter periods to fluids such as diesel and mineral oils. The resistance to these fluids is according to IEC The cable is reinforced with a steel wire braiding between the two sheaths. Strength elements of glass yarn around the cable core allow easy installation of long lengths. The 0.9 tight buffer is easy to strip allowing fast and reliable splicing and connector mounting. Each fibre is colour coded for easy identification. The outer sheath is marked to show fibre type and cable type. The outer sheath is BLACK. Secondary coated fibre Water swellable material Glass yarn Inner sheath Steel wire braiding Outer sheath Weight and dimensions Number of fibres Secondary coating Outer diameter Weight Tensile strength* [Inst./oper.] [N] [] [] [kg/km] / / / /750 Cable properties *Tensile strength (IEC E1) Max tensile load during installation Max tensile load during operation See above See above Temperature window Operation Installation -40 C to +70 C -10 C to +70 C Storage -40 C to +70 C Crush (IEC E3) 2000 N/10cm Water tightness* (IEC F5B) < 3 m/24 hours Impact (IEC E4) 1 impacts, 25J Fire and smoke classifications Torsion (IEC E7) 1 turn/1m IEC Cable bending Minimum bending diameter Cable bend (IEC E11) Flexibility (IEC E8) *) Steel wire braiding is not watertight. 15x outer diameter <0.5 db/ 5 turn 1000 cycles IEC (Cat. A) IEC (Cat. C) IEC IEC IEC Chemical reistance Mineral oils IRM 902 (IEC ) Diesel - IRM 903 (IEC ) - 7 days/23 C - 4 hours/70 C - 7 days/23 C - 4 hours/70 C Subject to change without prior notice Page 95 of 212
97 Ordering information Part no Number of fibres Cabe Type Fiber type Stock Item Fiber data sheet G4-9/125 AICI-I/O RM-W OS2 Single mode - C03e G8-9/125 AICI-I/O RM-W OS2 Single mode - C03e G12-9/125 AICI-I/O RM-W OS2 Single mode - C03e G24-9/125 AICI-I/O RM-W OS2 Single mode - C03e G4-50/125 AICI-I/O RM-W OM2 50/125 multi mode - C G8-50/125 AICI-I/O RM-W OM2 50/125 multi mode - C G12-50/125 AICI-I/O RM-W OM2 50/125 multi mode - C G24-50/125 AICI-I/O RM-W OM2 50/125 multi mode - C G4-50/125OM3BB AICI-I/O RM-W OM3 MaxCap-BB-OM3 - C G8-50/125OM3BB AICI-I/O RM-W OM3 MaxCap-BB-OM3 - C G12-50/125OM3BB AICI-I/O RM-W OM3 MaxCap-BB-OM3 - C G24-50/125OM3BB AICI-I/O RM-W OM3 MaxCap-BB-OM3 - C G4-62.5/125 AICI-I/O RM-W OM1 62.5/125 multi mode Yes C G8-62.5/125 AICI-I/O RM-W OM1 62.5/125 multi mode Yes C G /125 AICI-I/O RM-W OM1 62.5/125 multi mode - C G /125 AICI-I/O RM-W OM1 62.5/125 multi mode - C02 OM4 and other fibre types on request. Colour code Fibre Colour Fibre Colour Fibre Colour no. no. no. 1 White 9 Violet 17 Blue + marker 2 Red 10 Turquise 18 Grey + marker 3 Yellow 11 Orange 19 Brown + marker 4 Green 12 Pink 20 Light Blue + marker 5 Blue 13 White + marker 21 Violet + marker 6 Grey 14 Red + marker 22 Turquise + marker 7 Brown 15 Yellow + marker 23 Orange + marker 8 Black 16 Green + marker 24 Pink + marker Standard colour of outer sheath is black. We reserve the right to alter this specification without notice. Subject to change without prior notice Page 96 of 212
98 Flame retardant optical fibre cable, AICI-I/O/RM/C-W, MUD PROTECTED Armoured industrial cable AICI-I/O/RM/C-W Indoor and outdoor Flame retardant and halogen free Steel wire braiding Tight buffer MUD PROTECTED Optical cable for industrial environments. The cable is suitable for both indoor and outdoor installation. Continiuous submergence in water is not recoended. Outer sheath (1) is made from black UV-stabilized and weather resistant material and may be exposed for shorter periods to fluids such as diesel and mineral oils. The resistance to these fluids is according to IEC The cable is reinforced with a steel wire braiding between the two sheaths. Strength elements of glass yarn around the cable core allow easy installation of long lengths. The 0.9 tight buffer is easy to strip allowing fast and reliable splicing and connector mounting. Each fibre is colour coded for easy identification. The outer sheath is marked to show fibre type and cable type. Secondary coated fibre Water swellable material Glass yarn Inner sheath Steel wire braiding Outer sheath (1) Outer sheath (MUD) An additional outer sheath is added for improved oil- and MUD protection. The outer sheath is DARK GREY. Weight and dimensions Number of fibres Secondary coating Outer diameter Weight Tensile strength* [Inst./oper.] [] [] [kg/km] [N] / / / /750 Cable properties *Tensile strength (IEC E1) Max tensile load during installation Max tensile load during operation See above See above Temperature window Operation Installation -40 C to +70 C -10 C to +70 C Storage -40 C to +70 C Crush (IEC E3) 2000 N/10cm Water tightness* (IEC F5B) < 3 m/24 hours Impact (IEC E4) 1 impacts, 25J Fire and smoke classifications Torsion (IEC E7) 1 turn/1m IEC Cable bending Minimum bending diameter Cable bend (IEC E11) Flexibility (IEC E8) *) Steel wire braiding is not watertight. 15x outer diameter <0.5 db/ 5 turn 1000 cycles IEC (Cat. A) IEC (Cat. C) IEC IEC Chemical reistance Mineral oils IRM 902 (IEC ) Diesel - IRM 903 (IEC ) - 7 days /100 C - 7 days/100 C Subject to change without prior notice Page 97 of 212
99 Ordering information Part no Number of fibres Cabe Type Fiber type Stock Item Fiber data sheet G4-9/125 AICI-I/O/RM/C-W OS2 Single mode(g652d) - C03e * 8 G8-9/125 AICI-I/O/RM/C-W OS2 Single mode(g652d) - C03e * 12 G12-9/125 AICI-I/O/RM/C-W OS2 Single mode(g652d) - C03e * 24 G24-9/125 AICI-I/O/RM/C-W OS2 Single mode(g652d) - C03e * 4 G4-50/125 AICI-I/O/RM/C-W OM2 50/125 multi mode - C23 * 8 G8-50/125 AICI-I/O/RM/C-W OM2 50/125 multi mode - C G12-50/125 AICI-I/O/RM/C-W OM2 50/125 multi mode - C23 * 24 G24-50/125 AICI-I/O/RM/C-W OM2 50/125 multi mode - C23 * 4 G4-50/125OM3 AICI-I/O/RM/C-W OM3 MaxCap-OM3 - C31 * 8 G8-50/125OM3 AICI-I/O/RM/C-W OM3 MaxCap-OM3 - C31 * 12 G12-50/125OM3 AICI-I/O/RM/C-W OM3 MaxCap-OM3 - C31 * 24 G24-50/125OM3 AICI-I/O/RM/C-W OM3 MaxCap-OM3 - C G4-62.5/125 AICI-I/O/RM/C-W OM1 62.5/125 multi mode - C G8-62.5/125 AICI-I/O/RM/C-W OM1 62.5/125 multi mode - C02 * 12 G /125 AICI-I/O/RM/C-W OM1 62.5/125 multi mode - C02 * 24 G /125 AICI-I/O/RM/C-W OM1 62.5/125 multi mode - C02 Other fibre types/qualities on request(for example OM4) *) Part s will be given on request. On inquiries or orders, please refer to datasheet D92aici-mud_e22.doc Colour code Fibre Colour Fibre Colour Fibre Colour no. no. no. 1 White 9 Violet 17 Blue + marker 2 Red 10 Turquise 18 Grey + marker 3 Yellow 11 Orange 19 Brown + marker 4 Green 12 Pink 20 Light Blue + marker 5 Blue 13 White + marker 21 Violet + marker 6 Grey 14 Red + marker 22 Turquise + marker 7 Brown 15 Yellow + marker 23 Orange + marker 8 Black 16 Green + marker 24 Pink + marker The outer sheath is as standard dark grey. Subject to change without prior notice Page 98 of 212
100 Optical fibre data sheet Fibre type 9/125 50/125-OM2 50/125-OM3 62.5/125-OM1 Fiber data sheet C03 C34 C31 C02 IEC , 20, 50 cat. B.1.3 A1a.1 A1a.2 A1b IEC11801 classification OS2 OM2 OM3 OM1 ANSI/TIA/EIA classification CAAB AAAB AAAC AAAA ITU-T type G652.D G651.1 G Core diameter See mode field diameter m m m Mode field diameter 1310 nm m 1550 nm m Cladding diameter m m m m Primary coating diameter (nominal) m m m m Attenuation (Maximum values) 850 nm 1300 nm 1310 nm 1550 nm Bandwidth(OFL) 850 nm 1300 nm Chromatic Dispersion nm 1550 nm 1625 nm Polarization Mode Disp. Max. Individual Fibre PMD Q Link Design Value Group index of refraction 850 nm 1300/1310 nm(mmf/smf) 1550 nm 1625 nm 0.39 db/km 0.25 db/km 3 ps/nm km 18 ps/nm km 22 ps/nm km 0.5 ps/ km 0.2 ps/ km Other fibrequalities/types and qualities are available on request, e.g. OM4 fibre. 2.7 db/km db/km >500 MHz km >500 MHz km db/km db/km >1500 MHz km >500 MHz km db/km 1.0 db/km >200 MHz km >600 MHz km Subject to change without prior notice Page 99 of 212
101 ICS IE ToughCat 5e S/FTP Installation cable for tougher environments S/FTP Installation Cable for tougher environments Application Generic Data transmission. This cabel is a Cat5e S/FTP cable meant for use as installation(horizontal) cable in tougher electrical and mechanical environment, including ships and offshore units. Standards EN ; EN ISO/IEC 11801; IEC Det Norske Veritas (DNV) spesification No and Lloyd Register approval system, 2002 Fire rating LSHF-FR(SHF1) : IEC ; IEC 61034, IEC Chemical resistance Mineral oils IRM 902 (IEC ) 4 hours/70 C Diesel - IRM 903 (IEC ) 4 hours/70 C : 7 days/23 C : 7 days/23 C Certification This cable is certified by: Det Norske Veritas (DNV) and Lloyd Register. Construction Conductor Insulation Twisting Cable lay up Pair screen Overall screen Sheath Stranded copper wire Ø PE, Ø cores to the pair 4 pairs Al-laminated plastic foil around each pair Copper braid, tinned Ø 6,2 Oil resistant, Fire retardant and halogen free LSHF-FR(SHF1). Mechanical Properties Bending radius Without load 8 x D With load 4 x D Temperature range During operation -40 C to + 85 C During installation -15 C to + 50 C Fire load 4 pair 515 MJ/km Maximum tensile load During operation No load During installation 100 N Subject to change without prior notice Page 100 of 212
102 Electrical Properties at 20 C DC loop resistance 158 Ω/km Resistance unbalance 2% Insulation resistance (500 V) 5000 MΩxkm Capacitance at 800 Hz Nom. 43 nf/km Capacitance unbalance (pair to ground) 1500 pf/km Mean Characteristic 100 MHz) 100 ± 5 Ω Nominal velocity of propagation 0,75c Propagation delay 450 ns/100 m Delay skew 15 ns/100 m Transfer impedance at 1 MHz 10 mω /m at 10 MHz 8 mω /m at 30 MHz 10 mω /m Coupling attenuation 85 db Nominal Transmission characteristics at 20 C F Attenuation NEXT ACR Return loss PS-NEXT PS-ACR ELFEXT PS-ELFEXT (MHz) (db/100m) (db) (db/100m) (db) (db) (db/100m) (db/100m) (db/100m) 1 2, , , , , , , , , , , , , Technical data Part no. Description Colour Outer diameter ToughCat5 S/FTP 4x2/0,22² Grey RAL7035 Product Code Table Fire load Weight MJ/km kwh/m kg/km 7, , Product Description Product Code PG Reference Code PG Part Number ToughCat C5e LSHF-FR 4x2/ ToughCat C5e LSHF-FR 4x2/ DP DP ToughCat C5e LSHF-FR 4x2/ DP DP Subject to change without prior notice Page 101 of 212
103 ICS IE ToughCat 7 S/FTP Installation cable for tougher environments S/FTP Installation Cable for tougher environments Application Generic Data transmission. This cable is a Cat7 S/FTP cable meant for use as installation/horizontal cable in tougher electrical and mechanical environment, including ships and offshore units. Standards EN ; EN ISO/IEC 11801; IEC Det Norske Veritas (DNV) spesification No Fire rating LSHF-FR(SHF1) : IEC ; IEC 61034, IEC Chemical resistance Mineral oils IRM 902 (IEC ) Diesel - IRM 903 (IEC ) : 7 days/23 C, 4 hours/70 C : 7 days/23 C, 4 hours/70 C Certification This cable is certified by: Det Norske Veritas (DNV) and American Bureau of Shipping (ABS) Construction Conductor Insulation Twisting Cable lay up Pair screen Overall screen Sheath Stranded copper wire Ø PE, Ø cores to the pair 4 pairs Al-laminated plastic foil around each pair Copper braid, tinned Ø 6,6 Oil resistant, Fire retardant and halogen free LSHF-FR (SHF1). Mechanical Properties Bending radius Without load 8 x D With load 4 x D Temperature range During operation -40 C to + 85 C During installation -15 C to + 50 C Fire load 4 pair 670 MJ/km Maximum tensile load During operation No load During installation 100 N Subject to change without prior notice Page 102 of 212
104 Electrical Properties at 20 C DC loop resistance 138 Ω/km Resistance unbalance 2% Insulation resistance (500 V) 5000 MΩxkm Capacitance at 800 Hz Nom. 43 nf/km Capacitance unbalance (pair to ground) 1500 pf/km Mean Characteristic 100 MHz) 100 ± 5 Ω Nominal velocity of propagation 0,76c Propagation delay 450 ns/100 m Delay skew 15 ns/100 m Transfer impedance at 1 MHz 10 mω /m at 10 MHz 8 mω /m at 30 MHz 10 mω /m Coupling attenuation 85 db Nominal Transmission characteristics at 20 C F Attenuation NEXT ACR Return loss PS-NEXT PS-ACR ELFEXT PS-ELFEXT (MHz) (db/100m) (db) (db/100m) (db) (db) (db/100m) (db/100m) (db/100m) 1 2, , , , , , , , , , , , , Technical data Part no. Description Colour Outer diamete r ToughCat C7 LSHF-FR 4x2/0.272 Fire load Weight MJ/km kwh/m kg/km Grey RAL7035 8, , Product Code Table Product Description Product Code PG Reference Code PG Part Number ToughCat C7 LSHF-FR 4x2/ ToughCat C7 LSHF-FR 4x2/ DP DP ToughCat C7 LSHF-FR 4x2/ DP Subject to change without prior notice Page 103 of 212
105 ICS IE ToughCat 7S* S/FTP Installation cable for tougher environments S/FTP Installation Cable for tougher environments * Version with Solid conductors Application Generic Data transmission. This cable is a Cat7 S/FTP cable meant for use as installation/horizontal cable in tougher electrical and mechanical environment, including ships and offshore units. Standards EN ; EN ISO/IEC 11801; IEC Det Norske Veritas (DNV) specification No Fire rating LSHF-FR(SHF1) : IEC ; IEC 61034, IEC Chemical resistance Mineral oils IRM 902 (IEC ) Diesel - IRM 903 (IEC ) : 7 days/23 C, 4 hours/70 C : 7 days/23 C, 4 hours/70 C Certification This cable is certified by: Det Norske Veritas (DNV) Construction Conductor Solid copper wire, Ø 0.56 (AWG 23) Insulation foamskin PE, Ø 1.4 Twisting 2 cores to the pair Pair screen Al-laminated plastic foil Cable lay up 4 pairs (PiMF) to the core Screen copper braid, tinned Sheath Oil resistant, Fire retardant and halogen free LSHF-FR (SHF1). Mechanical properties Bending radius Without load 8 x D With load 4 x D Temperature range During operation -40 C to + 85 C During installation -15 C to + 50 C Fire load 4 pair 670 MJ/km Maximum tensile load During operation No load During installation 200 N Subject to change without prior notice Page 104 of 212
106 Electrical properties at 20 C± 5 C Loop resistance 150 Ω/km Resistance unbalance 2% Insulation resistance (500 V) 5000 MΩ*km Mutual capacitance at 800 Hz Nom. 43 nf/km Capacitance unbalance (pair/ground) 1500 pf/km Characteristic impedance (1-100 MHz) 100 ± 5 Ω ( ) MHz 100 ± 10 Ω ( ) MHz 100 ± 15 Ω Nominal velocity of propagation ca. 79 % Propagation delay 570 ns/100m Delay skew 9 ns/100m Test voltage (DC, 1 min) core/core and core/screen 1000 V Transfer impedance(grade 1) at 1 MHz 10 mω/m at 10 MHz 10 mω/m at 30 MHz 10 mω/m at 100MHz 20 mω/m Coupling attenuation 85 db Electrical data (nominal) acc. to Cat.7 (at 20 C) F (MHZ) Attenuation (db/100m) NEXT (db) PS-NEXT (db) ACR (db/100m) PS-ACR (db/100m) ELFEXT (db/100m) PS-ELFEXT (db/100m) Return loss (db) 1,0 1, ,0 3, ,0 5, ,0 6, ,0 7, ,2 9, ,5 13, ,0 17, ,0 19, ,5 21, ,0 23, ,0 25, ,0 28, ,0 30, ,0 38, ,0 44, Technical data Part no. Description Colour Outer diameter Fire load Weight MJ/km kwh/m kg/km ToughCat7S S/FTP 4x2/0.56 Grey RAL7035 7, , Product Code Table Product Description Product Code PG Reference Code PG Part Number ToughCat C7S LSHF-FR 4x2/ ToughCat C7S LSHF-FR 4x2/ DP DP Subject to change without prior notice Page 105 of 212
107 ICS IE ToughCat 5e MUD Protected S/FTP Installation cable for tougher environments S/FTP Installation Cable for tougher environments Application Generic Data transmission. This Cat.5e S/FTP cable is based on our DNV and Lloyd Register certified ToughCat, but with an additional fire retardant, halogen-free, low smoke MUD protecting outer jacket. This cabel is meant for use as installation/horisontal cable in tougher electrical and mechanical environment, including ships and offshore units. Standards EN ; EN ISO/IEC 11801; IEC Fire rating MUD protecting outer sheath : IEC , IEC 61034, IEC Inner sheath LSHF-FR(SHF1) : IEC , IEC 61034, IEC Chemical resistance Mineral oils IRM 902 (IEC ) Diesel - IRM 903 (IEC ) : 7 days/100 C : 7 days/100 C Construction Conductor Insulation Twisting Cable lay up Pair screen Overall screen Inner sheath Outer sheath Stranded copper wire Ø PE, Ø cores to the pair 4 pairs Al-laminated plastic foil around each pair Copper braid, tinned Ø 6,2 Oil resistant, Fire retardant and halogen free LSHF-FR (SHF1) Ø 7,7 MUD protecting Mechanical Properties Bending radius Installation 8 x D Installed 4 x D Temperature range During operation -40 C to + 85 C During installation -15 C to + 50 C Fire load 4 pair (On request) MJ/km Maximum tensile load, installation During installation 100 N Installed No load Subject to change without prior notice Page 106 of 212
108 Electrical Properties at 20 C DC loop resistance 158 Ω/km Resistance unbalance 2% Insulation resistance (500 V) 5000 MΩxkm Capacitance at 800 Hz Nom. 43 nf/km Capacitance unbalance (pair to ground) 300 pf/km Mean Characteristic 100 MHz) 100 ± 5 Ω Nominal velocity of propagation 0,75c Propagation delay 450 ns/100 m Delay skew 15 ns/100 m Transfer impedance at 1 MHz 10 mω /m at 10 MHz 8 mω /m at 30 MHz 10 mω /m Coupling attenuation 85 db Nominal Transmission characteristics at 20 C F Attenuation NEXT ACR Return loss PS-NEXT PS-ACR ELFEXT PS-ELFEXT (MHz) (db/100m) (db) (db/100m) (db) (db) (db/100m) (db/100m) (db/100m) 1 2, , , , , , , , , , , , , Technical data Part no. Description Colour Outer diameter ToughCat MUD C5e S/FTP P 4Px0.222 *)-On request Dark Grey RAL7024 Fire load Weight MJ/km kwh/m kg/km 9,6 *) *) 100 Product Code Table Product Description Product Code PG Reference Code PG Part Number ToughCat MUD C5e S/FTP P 4Px ToughCat MUD C5e S/FTP 4Px DP DP Subject to change without prior notice Page 107 of 212
109 ICS IE ToughCat 7 MUD Protected S/FTP Installation cable for tougher environments S/FTP Installation Cable for tougher environments Application Generic Data transmission. This cable is a Cat7 S/FTP cable is based on our DNV certified ToughCat, but with an additional fire retardant, halogen-free, low smoke MUD protecting outer jacket. This cabel is meant for use as installation/horisontal cable in tougher electrical and mechanical environment, including ships and offshore units. Standards EN ; EN ISO/IEC 11801; IEC Fire rating Inner sheath: LSHF-FR (SHF1) : IEC ; IEC 61034, IEC MUD protecting outer sheath : IEC ; IEC 61034, IEC Chemical resistance Mineral oils IRM 902 (IEC ) Diesel - IRM 903 (IEC ) : - 7 days/100 C : - 7 days/100 C Certification Pending. Construction Conductor Insulation Twisting Cable lay up Pair screen Overall screen Inner sheath Outer sheath Stranded copper wire Ø PE, Ø cores to the pair 4 pairs Al-laminated plastic foil around each pair Copper braid, tinned Ø 6,6 Oil resistant, Fire retardant and halogen free LSHF-FR (SHF1). MUD protecting Mechanical Properties Bending radius Without load 8 x D With load 4 x D Temperature range During operation -40 C to + 85 C During installation -15 C to + 50 C Fire load 4 pair (on request) MJ/km Maximum tensile load During operation No load During installation 100 N Subject to change without prior notice Page 108 of 212
110 Electrical Properties at 20 C DC loop resistance 138 Ω/km Resistance unbalance 2% Insulation resistance (500 V) 5000 MΩxkm Capacitance at 800 Hz Nom. 43 nf/km Capacitance unbalance (pair to ground) 1500 pf/km Mean Characteristic 100 MHz) 100 ± 5 Ω Nominal velocity of propagation 0,76c Propagation delay 450 ns/100 m Delay skew 15 ns/100 m Transfer impedance at 1 MHz 10 mω /m at 10 MHz 8 mω /m at 30 MHz 10 mω /m Coupling attenuation 85 db Nominal Transmission characteristics at 20 C F Attenuation NEXT ACR Return loss PS-NEXT PS-ACR ELFEXT PS-ELFEXT (MHz) (db/100m) (db) (db/100m) (db) (db) (db/100m) (db/100m) (db/100m) 1 2, , , , , , , , , , , , , Technical data Part no. Description Colour Outer diameter ToughCat MUD C7 S/FTP 4Px0.272 *) on request Fire load Weight MJ/km kwh/m kg/km Grey RAL ,1 *) *) 112 Product Code Table Product Description Product Code PG Reference Code PG Part Number ToughCat MUD C7 S/FTP 4Px ToughCat MUD C7 S/FTP 4Px DP DP Subject to change without prior notice Page 109 of 212
111 ICS IE ToughCat 7S* MUD Protected S/FTP Installation cable for tougher environments S/FTP Installation Cable for tougher environments * Version with Solid conductors Application Generic Data transmission. This cable is a Cat7 S/FTP cable is based on our DNV certified ToughCat, but with an additional fire retardant, halogen-free, low smoke MUD protecting outer jacket. This cabel is meant for use as installation/horisontal cable in tougher electrical and mechanical environment, including ships and offshore units. Standards EN ; EN ISO/IEC 11801; IEC Fire rating Inner sheath: LSHF-FR (SHF1) : IEC ; IEC 61034, IEC MUD protecting outer sheath : IEC ; IEC 61034, IEC Chemical resistance Mineral oils IRM 902 (IEC ) Diesel - IRM 903 (IEC ) : - 7 days/100 C : - 7 days/100 C Certification The base construction(exclusive the extra MUD sheath) is certified by DnV. Construction Conductor Solid copper wire, Ø 0.56 (AWG 23) Insulation foamskin PE, Ø 1.4 Twisting 2 cores to the pair Pair screen Al-laminated plastic foil Cable lay up 4 pairs (PiMF) to the core Screen copper braid, tinned Inner sheath Oil resistant, Fire retardant and halogen free LSHF-FR (SHF1). Outer sheath MUD protecting Mechanical properties Bending radius Without load 8 x D With load 4 x D Temperature range During operation -40 C to + 85 C During installation -15 C to + 50 C Fire load 4 pair 670 MJ/km Maximum tensile load During operation No load During installation 200 N Subject to change without prior notice Page 110 of 212
Offshore (IEC) 1/2013
Offshore (IEC) 1/2013 Contents 0,6/1kV cables LKM-SHF2 & LKM-SHF2 FLEX...4 LKMM-SHF2...8 LKSM-SHF2 & LKSM-SHF2 FLEX...10 LKMSM-SHF2...14 LKSM-EMC-SHF2...16 LKSM-VFD-SHF2...20 0,6/1kV FR cables LKM-FRSHF2...22
OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS
OFFSHORE CABLES GENERAL CATALOGUE Offshore Cables technergy INTEGRATED CABLING SOLUTIONS TM 1 TEOF Offshore Cables INTEGRATED CABLING SOLUTIONS TM technergy Introduction Every offshore platform requires
FLAME-X 950 (N)HXCH FE180/E90 0,6/1kV DIN VDE 0266, DIN
Halogen- free low smoke fire resistant security power cables with copper concentric conductor CONSTRUCTION Conductors: bare copper conductor, circular solid class 1 (RE) or stranded circular or circular
Screened electronic cable LiYCY
Screened electronic cable LiYCY Conductor material: bare copper Conductor class: class 5 = fine stranded Insulation: PVC Screen: copper braid, tinned Screen coverage: 70 % Sheathing material: PVC Flame-retardant:
Screened electronic cable LiYCY
Screened electronic cable LiYCY conductor material: bare copper conductor construction: fine stranded, class 5 insulation: PVC screen: Cu-braiding screen over strand: Cu-braid, tinned screen coverage:
Control cable YSLY-JZ/-JB/-OZ/-OB
Control cable YSLY-JZ/-JB/-OZ/-OB conductor material: bare copper conductor construction: fine stranded, class 5 insulation: PVC TI1 stranding unit: core sheathing material: PVC TM2 colour of outer sheath:
FRNC power cable Cu/XLPE/ LSZH/SWA/LSZH acc. to BS 6724
FRNC power cable Cu/XLPE/ LSZH/SWA/LSZH acc. to BS 6724 Conductor material: copper, bare Conductor class: class 2 = stranded Insulation: XLPE Material inner sheath: halogen-free Armour: round steel wire,
CHAROONG THAI WIRE & CABLE PUBLIC COMPANY LIMITED
CHAROONG THAI WIRE & CABLE PUBLIC COMPANY LIMITED CABLE TYPE : CTW-CVVS 00 V ( STRANDED CONDUCTOR ) : 00 V 70 C PVC INSULATED AND SHEATHED CONTROL CABLE WITH SHIELD TAPE PAGE 1/ APPLICATION Supervisory
Data/LAN Cables Cat 6 F/UTP PVC
Data/LAN Cables Cat 6 F/UTP PVC RoHS REACH Application 10 BASE-T (IEEE 802.3) Ethernet. 100 BASE-T (IEEE 802.3u) Fast Ethernet 100 VG-AnyLAN (IEEE 802.12). 4/6 Mbps Token Ring (IEEE 802.5) 100 Mbps CDDI.
FLAME RETARDANT POWER CABLE. 0.6/1kV SPYC, SPYCY, FA-SPYC, FA-SPYCY 0.6/1kV SPYCB, SPYCBY, FA-SPYCB, FA-SPYCBY. Application Standard
FLAME RETARDANT POWER CABLE Cable Designation 0.6/1kV SPYC, SPYCY, FA-SPYC, FA-SPYCY 0.6/1kV SPYCB, SPYCBY, FA-SPYCB, FA-SPYCBY Application Standard 0.6 / 1kV SPYCBY - Design guide : JIS C 3410(2010) -
Outer diameter (mm) ca.
........ Sz JZD...... SKW PRAKAB Products 1 CHKH R, 1 CXKH R Energy cable : TP PRAKAB 02/99 5. edition Rated voltage: 0.6/1 kv Usage: The cables are specified for stationary distribution of electrical
Halogen free Shipboard Cable IEC 60092-350, 353, 354, 376
Halogen free Shipboard IEC 60092-350, 353, 354, 376 TMC Co., Ltd has been pursuing innovation in technology and products for the specialty industrial cable market. For 23 years TMC has had a single-minded
Pipe E235N (St 37.4 NBK) phosphated and oiled
Pipe E235N (St 37.4 NBK) phosphated and oiled Working Pressure Burst Pressure 4X1ST37.4NBK* 4 x 1.0 3201041000 397 459 555 2600 0.07 6X1ST37.4NBK 6 x 1.0 3201061000 252 289 394 1560 0.12 6X1.5ST37.4NBK
C4C-C4H-C4G-C4M MKP Series AXIAL CAPACITORS PCB APPLICATIONS
C4C-C4H-C4G-C4M AXIAL CAPACITORS PCB APPLICATIONS General characteristics - Self-Healing - Low losses - High ripple current - High contact reliability - Suitable for high frequency applications 40 ±5 L
Applications Coaxial cables for high frequency. Coaxial cables from 50 Ω to 95 Ω. Construction
Standard coaxial cables KX & RG coaxial cables KX/RG Applications Coaxial cables for high frequency connections. Coaxial cables from 50 Ω to 95 Ω Construction 1- CONDUCTOR Stranded or solid, in bare copper
RJ45-patch cable Cat.7, 600 MHz, 10 GBit/s Corning FutureCom TM S/FTP flex/26 + Hirose TM31
RJ45-patch cable Cat.7, 600 MHz, 10 GBit/s Corning FutureCom TM S/FTP flex/26 + Hirose TM31 Application as patch cables in patch panels and appliance connection boxes for networks to 10 GBit/s Features
± 20% ± 5% ± 10% RENCO ELECTRONICS, INC.
RL15 RL16, RL17, RL18 MINIINDUCTORS CONFORMALLY COATED MARKING The nominal inductance is marked by a color code as listed in the table below. Color Black Brown Red Orange Yellow Green Blue Purple Grey
B37631 K K 0 60
Multilayer Ceramic acitors High; X5R and X7R Chip Ordering code system B37631 K 7 5 K 6 Packaging 6 ^ cardboard tape, 18-mm reel 62 ^ blister tape, 18-mm reel Internal coding acitance tolerance K ^ ± %
Cables. Marine and Offshore Electrical Supply Pg 21 ORDERLINE P5/P12 BFOU 0.6/1kV
ORDERLINE +65 6291 4444 3 x 185 59.3 8440 A4613185 3 x 240 66.6 10920 A4613240 3 x 300 73.3 13410 A4613300 4 x 1 14.9 350 A4614000 4 x 1.5 15.7 390 A4614001 4 x 2.5 16.8 460 A4614002 4 x 4 18.2 580 A4614004
Metal Oxide Leaded Film Resistor
Features -Excellent Long-Time stability -High surge / overload capability -Wide resistance range : 0.1Ω~22MΩ -Controlled temperature coefficient -Resistance standard tolerance: ±5% (consult factory for
Data sheet Thick Film Chip Resistor 5% - RS Series 0201/0402/0603/0805/1206
Data sheet Thick Film Chip Resistor 5% - RS Series 0201/0402/0603/0805/1206 Scope -This specification applies to all sizes of rectangular-type fixed chip resistors with Ruthenium-base as material. Features
Contents. Twisted Pair, Model 600103 & 600104. www.vibrasens.com. Overview
Contents Twisted Pair, Model 600103 & 600104...61 Twisted Pair, Low Noise Model 60000.XX, 60002.XX...63 Twisted Triples, Model 600106 & 600107...64 600103.21 Polyurethane / - to 90 C / dia 4.9 mm (0.193
Metal Film Leaded Precision Resistor
Power ratio(%) MFR Series Features Excellent overall stability Very tight tolerance down to ±0.05% Extremely low TCR down to ±5 PPM/ C High power rating up to 3 Watts Excellent ohmic contact Applications
Metal Oxide Leaded Film Resistor
SURFACE TEMP. RISE ( ) Power Ratio(%) MOF0623, 0932, 1145, 1550, 1765, 2485 MOF Series Features -Excellent Long-Time stability -High surge / overload capability -Wide resistance range : 0.1Ω~10MΩ -Controlled
Thin Film Chip Resistors
FEATURES PRECISE TOLERANCE AND TEMPERATURE COEFFICIENT EIA STANDARD CASE SIZES (0201 ~ 2512) LOW NOISE, THIN FILM (NiCr) CONSTRUCTION REFLOW SOLDERABLE (Pb FREE TERMINATION FINISH) Type Size EIA PowerRating
Multilayer Ceramic Chip Capacitors
FEATURES X7R, X6S, X5R AND Y5V DIELECTRICS HIGH CAPACITANCE DENSITY ULTRA LOW ESR & ESL EXCELLENT MECHANICAL STRENGTH NICKEL BARRIER TERMINATIONS RoHS COMPLIANT SAC SOLDER COMPATIBLE* PART NUMBER SYSTEM
Smaller. 6.3 to 100 After 1 minute's application of rated voltage at 20 C, leakage current is. not more than 0.03CV or 4 (µa), whichever is greater.
Low Impedance, For Switching Power Supplies Low impedance and high reliability withstanding 5000 hours load life at +05 C (3000 / 2000 hours for smaller case sizes as specified below). Capacitance ranges
Carbon Film Leaded Resistor
Features -The most economic industrial investment -Standard tolerance: +/-5% (available +/-2%) -Excellent long term stability -Termination: Standard solder-plated copper lead Applications -Telecommunication
Multilayer Ceramic Chip Capacitors
FEATURES X7R, X6S, X5R AND Y5V DIELECTRICS HIGH CAPACITANCE DENSITY ULTRA LOW ESR & ESL EXCELLENT MECHANICAL STRENGTH NICKEL BARRIER TERMINATIONS RoHS COMPLIANT SAC SOLDER COMPATIBLE* Temperature Coefficient
Applications. 100GΩ or 1000MΩ μf whichever is less. Rated Voltage Rated Voltage Rated Voltage
Features Rated Voltage: 100 VAC, 4000VDC Chip Size:,,,,, 2220, 2225 Electrical Dielectric Code EIA IEC COG 1BCG Applications Modems LAN / WAN Interface Industrial Controls Power Supply Back-Lighting Inverter
SMD Wire Wound Ferrite Chip Inductors - LS Series. LS Series. Product Identification. Shape and Dimensions / Recommended Pattern LS0402/0603/0805/1008
SMD Wire Wound Ferrite Chip Inductors - LS Series LS Series LS Series is the newest in open type ferrite wire wound chip inductors. The wire wound ferrite construction supports higher SRF, lower DCR and
SMC SERIES Subminiature Coaxial Connectors
SERIES Subminiature Coaxial Connectors FEATURES Subminiature coaxial connectors with 50 Ω impedance for applications up to 10 GHz. (screw on mechanism)fulfills the subminiature coaxial connector requirement
Heat exchanger. Type WT. For the reheating of airflows in rectangular ducting PD WT 1. 03/2017 DE/en
X X testregistrierung Heat exchanger Type For the reheating of airflows in rectangular ducting Rectangular hot water heat exchanger for the reheating of airflows, suitable for VAV terminal units Type TVR,
LS series ALUMINUM ELECTROLYTIC CAPACITORS CAT.8100D. Specifications. Drawing. Type numbering system ( Example : 200V 390µF)
Snap-in Terminal Type, 85 C Standard Withstanding 3000 hours application of rated ripple current at 85 C. Compliant to the RoHS directive (2011/65/EU). LS Smaller LG Specifications Item Category Temperature
SMC SERIES Subminiature Coaxial Connectors
SERIES Subminiature Coaxial Connectors FEATURES Subminiature coaxial connectors with 50 Ω impedance for applications up to 10 GHz. (screw on mechanism)fulfills the subminiature coaxial connector requirement
Specification. code ±1.0 ±1.0 ±1.0 ±1.0 ±0.5 approx (g)
High CV-value Long Life > 10 years at 50 C Low ESR and ESL High stability, 10 years shelf life Optimized designs available on request RoHS Compliant application Basic design Smoothing, energy storage,
THICK FILM LEAD FREE CHIP RESISTORS
Features Suitable for lead free soldering. Compatible with flow and reflow soldering Applications Consumer Electronics Automotive industry Computer Measurement instrument Electronic watch and camera Configuration
Mechanical Properties. Electical conductivity 3) < 0.5 mω non conductive < 0.5 mω 1) 2)
CABE CAMPS Metallic Cable Clamp A MS 3420 Bushing Shell material: A - Aluminum Alloy B - Copper Alloy C - Stainless Steel Surface treatment: A - Black Zinc-Cobalt C - Black Polyurethane Varnished E - Electro
CSR series. Thick Film Chip Resistor Current Sensing Type FEATURE PART NUMBERING SYSTEM ELECTRICAL CHARACTERISTICS
FEATURE Operating Temperature: -55 ~ +155 C 3 Watts power rating in 1 Watt size, 1225 package High purity alumina substrate for high power dissipation Long side terminations with higher power rating PART
Magnet Wire General Engineering Data Bare and Film Insulated Copper and Aluminum
Magnet Wire General Engineering Data Bare and Film Insulated Copper and Aluminum CABLE Magnet Wire General Engineering Data Bare and Film Insulated Copper and Aluminum Forward This booklet contains engineering
Metal Film Leaded Precision Resistor
Features Excellent overall stability Very tight tolerance down to ±0.05% Extremely low TCR down to ±5 PPM/ C High power rating up to 3 Watts Excellent ohmic contact Construction Applications Telecommunication
Terminal Contact UL Insulation Designation (provided with) style form system approval Flux tight
eatures A miniature PCB Power Relay. form A contact configuration with quick terminal type. 5KV dielectric strength, K surge voltage between coils to contact. Ideal for high rating Home Appliances of heating
Thin Film Chip Inductor
Scope -Viking s 0201 and 0402 series inductor is a photo lithographically etched single layer ceramic chip. Viking s design provides high, excellent Q, and superior temperature stability. This highly stable
Sunlord. Wire Wound SMD Power Inductors SPH Series Operating Temp. : -40 ~+125 (Including self-heating) 2R2 SPH
Wire Wound SMD Power Inductors SPH Series Operating Temp. : -4 ~+25 (Including self-heating) FEATURES Magnetic-resin shielded construction reduces buzz noise to ultra-low levels Metallization on ferrite
2R2. 2 (L W H) [mm] Wire Wound SMD Power Inductor. Nominal Inductance Packing Tape & Reel. Design Code M ±20%
Wire Wound SMD Power Inductors WPN Series Operating temperature range : -40 ~+125 (Including self-heating) FEATURES Fe base metal material core provides large saturation current Metallization on ferrite
HSB Series. 1. Specifications DIN VDE 0110 Concerning clearance and creepage distances DIN VDE 0627 Connectors and plug devices
HSB Series 1. Specifications DIN VDE 0110 Concerning clearance and creepage distances DIN VDE 0627 Connectors and plug devices 2. Standards DIN EN 60 664-1 DIN EN 61 984 3. Approvals 169 All specifications
PPA Metallized polypropylene film capacitor MKP - Snubber/pulse - High current
Main applications Snubber capacitor for energy conversion and control in power semiconductor circuits, protection circuits in SMPSs, induction heaters, high voltage, high current and high pulse applications
Shape Square. Tolerance of Varistor Voltage For Varistor voltage<68, Special For Varistor voltage 68, 10% Lead Wire Type Straight Cut Lead
Leaded Varistor for urge uppression VP eries Operating Temp. : -40 ~ +85 FEATURE Fast response Excellent clamping ratio, high peak current and pulse energy withstanding characteristics, providing strong
QUICKTRONIC PROFESSIONAL QTP5
osram.com QUICKTRONIC PROFESSIONA QTP5 ECG for T5/ 16mm, T8/ 26mm, DUUX fluorescent lamps QTP5 i.e. UMIUX T5 HO ES 01 Product Features: Up to 100.000 hours lifetime 1 amp start with optimized filament
Metal Oxide Varistors (MOV) Data Sheet
Φ SERIES Metal Oxide Varistors (MOV) Data Sheet Features Wide operating voltage (V ma ) range from 8V to 0V Fast responding to transient over-voltage Large absorbing transient energy capability Low clamping
FEATURES APPLICATION PRODUCT T IDENTIFICATION PRODUCT T DIMENSION MAG.LAYERS
FEATURES RoHS compliant. Super low resistance, ultra high current rating. High performance (I sat) realized by metal dust core. Frequency Range: up to 1MHz. APPLICATION PDA, notebook, desktop, and server
S /5000 BTU/Hr. 1000/1500 Watt
763.576.32 SPEC-168 D763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners SPECTRACOOL SLIM FIT INDOOR S6 1/17 BTU/Hr. 3/5 Watt S1 34/5 BTU/Hr. 1/15 Watt
Sunlord Specifications subject to change without notice. Please check our website for latest information. Revised 2018/04/15
Wire Wound SMD Power Inductors SPH Series Operating Temp. : -40 ~+125 (Including self-heating) FEATURES Magnetic-resin shielded construction reduces buzz noise to ultra-low levels Metallization on ferrite
Single-channel Safety Barriers Series 9001
Technical Data Certificates Explosion protection Europe (CENELEC) PTB 01 ATEX 2088 PTB 01 ATEX 2135 (Installation in Zone 2) USA FM Approval 3011002 UL Approval E81680 Canada CSA 1284547 (LR 43394) Russia
RJJ Miniature Aluminum Electrolytic Capacitors RJJ. Series RJJ High-Frequency, Low Impedance, Standard Type. Radial Type
352 Elna Corrections 80-95 /6/98 :55 AM Page Miniature Aluminum Electrolytic Capacitors Series High-Frequency, Low Impedance, Standard Type For high reliability applications, Environmentally safe. High-frequency,
Surface Mount Multilayer Chip Capacitors for Commodity Solutions
Surface Mount Multilayer Chip Capacitors for Commodity Solutions Below tables are test procedures and requirements unless specified in detail datasheet. 1) Visual and mechanical 2) Capacitance 3) Q/DF
ALUMINUM ELECTROLYTIC CAPACITORS LKG
Lug / Snap-in Terminal Type, For Audio Equipment Disigned for high grade audio equipment, giving priority to high fidelity sound quality. The variation expansion of the. TYPE-: The low profile high tone
Multilayer Chip Capacitors C0G/NP0/CH
Multilayer Chip Capacitors C0G/NP0/CH Features Good thermal stability High insulation resistance Low dissipation factor Low inductance Applications Resonant circuits Filter circuits Timing elements Coupling
COMPOSITE INSULATOR. ANSI Standard Type COMPOSITE LONGE ROD SUSPENSION INSULATOR. PDI 16mm Diameter Rod Deadend Insulators
COMPOSITE LONGE ROD SUSPENSION INSULATOR PDI 16mm Diameter Rod Deadend Insulators Mechanical Characteristics Item of Length Diameter Net Wt. Torsion SML RTL Proof Cat. Sheds (kg) (N-m) (kn) (kn) (kn) 1
Current Sensing Chip Resistor SMDL Series Size: 0201/0402/0603/0805/1206/1010/2010/2512/1225/3720/7520. official distributor of
Product: Current Sensing Chip Resistor SMDL Series Size: 0201/0402/0603/0805/1206/1010/2010/2512/1225/3720/7520 official distributor of Current Sensing Chip Resistor (SMDL Series) 1. Features -3 Watts
Configurations: Dimension (mm) B (max) A (max) 0.20 IWCCG1005. Inductance Range IWCCG ~ IWCCG ~ 1000 IWCCG
Configurations: FEATURES High frequency. Highest possible SRFs as well as excellent Q values. The wire is wound directed on the core at a precision pitch. RoHS Compliant. APPLICATION Pagers, Cordless phones
BMA SERIES Subminiature Blind Mate Connectors
SERIES Subminiature Blind Mate Connectors FEATURES The blindmate connectors are designed for blindmate applications up to Ghz. They have a slide-on, non-locking interface which ensures frequent matings
IWCSeries FEATURES APPLICATION ORDERING CODE TRIGON COMPONENTS. Configurations: Dimension (mm) IWC C G 1608 K 22N T (1) (2) (3) (4) (5) (6) (7)
Configurations: FEATURES High frequency. Highest possible SRFs as well as excellent Q values. The wire is wound directed on the core at a precision pitch. RoHS Compliant. APPLICATION Pagers, Cordless phones
4. Construction. 5. Dimensions Unit mm
1. Scope This specification applies to all sizes of rectangular-type fixed chip resistors with Ni/Cr as material. 2. Features Tolerance from 0.01%1% Thin film & Ni/Cr Resistor TCR from 5ppm 50ppm for thin
NTC Thermistor:TTC3 Series
Features. RoHS compliant 2. Halogen-Free(HF) series are available 3. Body size: Ф3mm 4. Radial lead resin coated 5. Operating temperature range: -40 ~+25 6. Wide resistance range 7. Cost effective 8. Agency
Fixed Inductors / AL TYPE
.Features: 1.Coating epoxy resin that ensures the humidity resistance to be long life. 2.Contribute to be high Q and selfresonant frequencies.applications: 1.Electronics products. 2.Communication equipment.
CSK series. Current Sensing Chip Resistor. Features. Applications. Construction FAITHFUL LINK
CSK series Current Sensing Chip Resistor Features» 3 Watts power rating in 1 Watt size, 1225 Package» Low TCR of ±100 PPM/ C» Resistance values from 1m to 1 ohm» High purity alumina substrate for high
Polymer PTC Resettable Fuse: KRG Series
Features 1. RoHS & Halogen-Free (HF) compliant 2. Radial leaded devices 3. Broadest range of resettable devices available in the industry 4. Hold current ratings from 0.1 to 3.75A 5. Maximum voltage is
SMD Transient Voltage Suppressors
SMD Transient Suppressors Feature Full range from 0 to 22 series. form 4 to 60V RMS ; 5.5 to 85Vdc High surge current ability Bidirectional clamping, high energy Fast response time
FIREX -II TECK CABLE. Introduction. Index. FIREX -II TECK Cable 1
FIREX -II TECK CABLE Introduction For more than 85 years, Nexans has been a leading designer and manufacturer of electrical cables for a wide variety of applications. As a technology leader, Nexans has
Accu-Guard II. SMD Thin-Film Fuse ELECTRICAL SPECIFICATIONS
Accu-Guard II is a version of Accu-Guard fuses for a wider range of current and voltage ratings. Con struct ed on alumina substrates, Accu-Guard II fuses display superior electrical, mechanical and en
LR Series Metal Alloy Low-Resistance Resistor
Tel : 881745 Fax : 881749 LR Series Metal Alloy LowResistance Resistor This specification is applicable to lead free, halogen free of RoHS directive for metal alloy lowresistance resistor. The product
Metal Film Flame-Proof Resistors
Features -Low Noise -Low TCR from ±15~100PPM/ -High Precision from ±0.1%~1% -Complete Flameproof Construction UL-1412. -Coating meets UL94V-0 Applications -Telecommunication -Medical Equipment -Consumer
TIME SWITCHES AND TWILIGHT SWITCHES
W ANALOG DIN-RAIL TIME SWITCH QUARTZ, SERIES TEMPUS ANALOG 244 W SCHRACK-INFO Analogue time switch 1 channel Daily program With power reserve (NiMH rechargeable battery) Synchronised with mains Shortest
YJM-L Series Chip Varistor
Features 1. RoHS & Halogen Free (HF) compliant 2. EIA size: 0402 ~ 2220 3. Operating voltage: 5.5Vdc ~ 85Vdc 4. High surge suppress capability 5. Bidirectional and symmetrical V/I characteristics 6. Multilayer
Thick Film Array Chip Resistor
CN Series Scope -This specification applies to all sizes of rectangular-type fixed chip resistors with Ruthenium-base as material. Features -Small size and light weight -Reduction of assembly costs and
Aluminum Electrolytic Capacitors (Large Can Type)
Aluminum Electrolytic Capacitors (Large Can Type) Snap-In, 85 C TS-U ECE-S (U) Series: TS-U Features General purpose Wide CV value range (33 ~ 47,000 µf/16 4V) Various case sizes Top vent construction
Interference Suppression Capacitor
MOLDED BOX CONSTRUCTION, SUPPRESSION CAPACITOR, RADIAL LEAD FEATURES UL, CSA, VDE, CQC, CE, ENEC APPROVALS X2 SAFETY CAP CLASSIFICATION FOR USE IN ACROSS-THE-LINE APPLICATIONS METALLIZED POLYPROPYLENE
MAX-QUALITY ELECTRIC CO; LTD Thin Film Precision Chip Resistors. Data Sheet
Data Sheet Customer: Product: Size: Current Sensing Chip Resistor CS Series 0201/0402/0603/0805/1206/1010/2010/2512 1225/3720/7520 Issued Date: Edition : 12-Nov-10 REV.C5 Current Sensing Chip Resistor
PRODUCT IDENTIFICATION SWPA 3012 S 1R0 N T
Wire Wound SMD Power Inductors SWPA Series Operating temperature range: -4 ~+25 (Including self-heating) FEATURES Magnetic-resin shielded conruction reduces buzz noise to ultra-low levels Metallization
SMD Power Inductor-VLH
SMD Power Inductor-VH Dimensions Unit: mm Type A B C E F H I J 252010 2.5±0.2 2.0±0.2 1.0max. 0.4±0.2 1.0min. 2.1 0.90 0.8 252012 2.5±0.2 2.0±0.2 1.2max. 0.4±0.2 1.0min. 2.1 0.90 0.8 321618C 3.2±0.3 1.6±0.2
Thin Film Chip Resistors
FETURES PRECISE TOLERNCE ND TEMPERTURE COEFFICIENT EI STNDRD CSE SIZES (0201 ~ 2512) LOW NOISE, THIN FILM (NiCr) CONSTRUCTION REFLOW SOLDERLE (Pb FREE TERMINTION FINISH) RoHS Compliant includes all homogeneous
DATA SHEET Surface mount NTC thermistors. BCcomponents
DATA SHEET 2322 615 1... Surface mount N thermistors Supersedes data of 17th May 1999 File under BCcomponents, BC02 2001 Mar 27 FEATURES High sensitivity High accuracy over a wide temperature range Taped
LR Series Metal Alloy Low-Resistance Resistor
LR Series Metal Alloy LowResistance Resistor This specification is applicable to lead free, halogen free of RoHS directive for metal alloy lowresistance resistor. The product is for general purpose. The
Data sheet Thin Film Chip Inductor AL Series
Data sheet Thin Film Chip Inductor AL Series Scope - 0201 and 0402 and 0603 series inductor is a photo lithographically etched single layer ceramic chip. This design provides high SRF, excellent Q, and
ΙΑΤΡΙΚΟΣ ΕΞΟΠΛΙΣΜΟΣ ΑΝΑΛΩΣΙΜΑ ΕΞΕΤΑΣΤΙΚΟΙ ΦΑΚΟΙ & ΦΩΤΙΣΜΟΣ
ΙΑΤΡΙΚΟΣ ΕΞΟΠΛΙΣΜΟΣ ΑΝΑΛΩΣΙΜΑ ΕΞΕΤΑΣΤΙΚΟΙ ΦΑΚΟΙ & ΦΩΤΙΣΜΟΣ ZOOM Modern LE Ds lamp of cold light with a 5X magni - fication. The intensity of light can be adjusted. Its articulated arm eases the movement
NTC Thermistor:SCK Series
Features. RoHS compliant 2. Body size Ф5mm~ Ф 30mm 3. Radial lead resin coated 4. High power rating 5. Wide resistance range 6. Cost effective 7. Operating temperature range: Φ5mm:-40~+50 Φ8~Φmm:-40~+70
Lowara SPECIFICATIONS
SH Series Centrifugal pumps entirely made of AISI 36 stainless steel according to EN 733 (ex DIN 24255). Designed to pump hot, cold and moderately aggressive liquids. Available versions: SHE Close-coupled
Sunlord. Wire Wound SMD Power Inductors SWCS Series SWCS XXXX -XXX T. Operating Temperature: -25 ~ +105 FEATURES APPLICATIONS PRODUCT IDENTIFICATION
Wire Wound SMD Power Inductors SWCS Series Operating Temperature: -25 ~ +105 FEATURES Various high power inductors are superior to be high saturation Suitable for surface mounting equipment APPLICATIONS
Fixed Inductors / AL TYPE
.Features: 1.Coating epoxy resin that ensures the humidity resistance to be long life. 2.Contribute to be high Q and selfresonant frequencies.applications: 1.Electronics products. 2.Communication equipment.
NMBTC.COM /
Common Common Vibration Test:... Conforms to JIS C 60068-2-6, Amplitude: 1.5mm, Frequency 10 to 55 Hz, 1 hour in each of the X, Y and Z directions. Shock Test:...Conforms to JIS C 60068-2-27, Acceleration
MMCX SERIES Microminiature Coaxial Connectors
SERIES Microminiature Coaxial Connectors FEATURES connectors are smaller than MCX connectors and are used from DC up to 6 GHz in applications where a tiny size is crucial. INTERFACE MATING DIMENSIONS PLUG:
NTC Thermistor:SCK Series
Features. RoHS & HF compliant 2. Body size: Ф5mm ~ Ф 30mm 3. Radial lead resin coated 4. High power rating 5. Wide resistance range 6. Cost effective 7. Operating temperature range: Φ5mm:-40~+50 Φ8~Φ0mm:-40~+70
PEH C High CV-value Long Life, > 10 years at 50 C Low ESR and ESL High stability, 10 years shelf life
PEH 169 85 C High CV-value Long Life, > 10 years at 50 C Low ESR and ESL High stability, 10 years shelf life APPLICATION BASIC DESIGN Smoothing, energy storage, or pulse operation in telecommunication
AT Surface Mount Package SOT-363 (SC-70) I I Y. Pin Connections B 1 C 1 E 1 E 2 C 2 B , 7:56 PM
AT-3263 Surface Mount Package SOT-363 (SC-7) I I Y Pin Connections B 1 C 1 E 1 E 2 C 2 B 2 Page 1 21.4., 7:6 PM Absolute Maximum Ratings [1] Absolute Thermal Resistance [2] : Symbol Parameter Units Maximum
Bulletin 1489 UL489 Circuit Breakers
Bulletin 489 UL489 Circuit Breakers Tech Data 489-A Standard AC Circuit Breaker 489-D DC Circuit Breaker 489-A, AC Circuit Breakers 489-D, DC Circuit Breakers Bulletin 489-A Industrial Circuit Breaker
Current Sense Metal Strip Resistors (CSMS Series)
Features: Range: 1mΩ to 100mΩ Low TCR as low as 75PPM High power rating Custom Values available RoHS Compliant and Halogen Free Operating Temperature: -55 C to +170 C Part Number Structure CSMS 0805 -
No item Digit Description Series Reference (1) Meritek Series SI Signal Inductor LI: Leaded Inductor PI: Power Inductor
PART NUMBERING SYSTEM SI F 0805 K 780 F (1) (2) (3) (4) (5) (6) No item Digit Description Series Reference (1) Meritek Series SI Signal Inductor LI: Leaded Inductor PI: Power Inductor (2) Type F Ferrite
SPECIFICATION FOR APPROVAL
信昌電子陶瓷股份有限公司 Prosperity Dielectrics Co., Ltd. No. 148, Chang-An Road, Sec 1,Lu-Tsu Shiang, Taoyuan, Taiwan, ROC. Tel.:886-3-3224471 Fax:886-3-3212216 SPECIFICATION FOR APPROVAL DATE: CUSTOMER: LIMITED
SMD Power Inductor-VLH
SMD Power Inductor-VH PAD AYOUT Dimensions Unit: mm Type A B C E F H I J 252010 2.5±0.2 2.0±0.2 1.0max. 0.4±0.2 1.0min. 2.1 0.90 0.8 252012 2.5±0.2 2.0±0.2 1.2max. 0.4±0.2 1.0min. 2.1 0.90 0.8 252510 2.5±0.2