Our annual production capacity is 3000 tons for copper and 4000 tons for PVC.

Σχετικά έγγραφα
Control cable YSLY-JZ/-JB/-OZ/-OB

FLAME-X 950 (N)HXCH FE180/E90 0,6/1kV DIN VDE 0266, DIN

Screened electronic cable LiYCY

Screened electronic cable LiYCY

Outer diameter (mm) ca.

Offshore (IEC) 1/2013

FRNC power cable Cu/XLPE/ LSZH/SWA/LSZH acc. to BS 6724

Applications Coaxial cables for high frequency. Coaxial cables from 50 Ω to 95 Ω. Construction

CHAROONG THAI WIRE & CABLE PUBLIC COMPANY LIMITED

FLAME RETARDANT POWER CABLE. 0.6/1kV SPYC, SPYCY, FA-SPYC, FA-SPYCY 0.6/1kV SPYCB, SPYCBY, FA-SPYCB, FA-SPYCBY. Application Standard

Data/LAN Cables Cat 6 F/UTP PVC

[1] P Q. Fig. 3.1

Siam Pacific Electric Wire & Cable Co., Ltd.

4 Way Reversing Valve

4 Way Reversing Valve

ΕΤΑΙΡΙΑ: ΒΑΣΙΛΕΙΟΣ Δ. ΡΟΓΚΑΚΟΣ ΙΑΤΡΙΚΑ ΜΗΧΑΝΗΜΑΤΑ ΦΙΛΤΡΑ ΝΕΡΟΥ CONSUMER ELECTRONICS OPTICUM DVB-T

Shape Square. Tolerance of Varistor Voltage For Varistor voltage<68, Special For Varistor voltage 68, 10% Lead Wire Type Straight Cut Lead

Specification. code ±1.0 ±1.0 ±1.0 ±1.0 ±0.5 approx (g)

LOWARA e-nsce, e-nscs, e-nscf

DLG Series. Lowara SPECIFICATIONS APPLICATIONS ACCESSORIES MATERIALS. General Catalogue

Ventilated Distribution Transformers

the total number of electrons passing through the lamp.

Product Catalog NEK 606/BFOU/RFOU/BU/RU. Marine, oil, gas and offshore cables

Lowara SPECIFICATIONS

SMD Power Inductor-VLH

NMBTC.COM /

C4C-C4H-C4G-C4M MKP Series AXIAL CAPACITORS PCB APPLICATIONS

Aluminum Electrolytic Capacitors (Large Can Type)

SMC SERIES Subminiature Coaxial Connectors

Strain gauge and rosettes

NKT NTC Thermistor. Negative Temperature Coefficient Thermistor FEATURES

SMD Power Inductor-VLH

Precision Metal Film Fixed Resistor Axial Leaded

SMC SERIES Subminiature Coaxial Connectors

Thermistor (NTC /PTC)

Metal thin film chip resistor networks

SMB SERIES Subminiature Coaxial Connectors

Ceramic PTC Thermistor Overload Protection

Applications Water distribution

Lowara APPLICATIONS MATERIALS. General Catalogue

Creative TEchnology Provider

Engineer Reference 1 / / A 35 7/16 X 7 7/8 X 23 5/8 31 1/8 X 21 7/8 X 11 1/4 14 T T 75 R410A oz/ft over 50' 265 / 318 / 388

Applications. 100GΩ or 1000MΩ μf whichever is less. Rated Voltage Rated Voltage Rated Voltage

RCS750 3-circuit square track system flexible and multifunctional

QUICKTRONIC PROFESSIONAL QTP5

Aluminum Electrolytic Capacitors

Shenzhen Lys Technology Co., Ltd

FP series Anti-Bend (Soft termination) capacitor series

DC-DC converter circuits for mobile phones, wearbale devices, DVCs, HDDs, etc.

Magnet Wire General Engineering Data Bare and Film Insulated Copper and Aluminum

DATA SHEET Surface mount NTC thermistors. BCcomponents

ZLW Series. Single-stage Monoblock Centrifugal Pump ZL PUMP GROUP.,LTD

UDZ Swirl diffuser. Product facts. Quick-selection. Swirl diffuser UDZ. Product code example:

Pipe E235N (St 37.4 NBK) phosphated and oiled

LS01-15B09SS LS01-15B12SS LS01-15B15SS LS01-15B24SS LS03-15B03SR2S LS03-15B05SR2S LS03-15B09SR2S LS03-15B12SR2S LS03-15B15SR2S LS03-15B24SR2S

Metal Oxide Varistor (MOV) Data Sheet

PRODUCT IDENTIFICATION SWPA 3012 S 1R0 N T

Terminal Contact UL Insulation Designation (provided with) style form system approval Flux tight

Heat exchanger. Type WT. For the reheating of airflows in rectangular ducting PD WT 1. 03/2017 DE/en

Current Sensing Chip Resistor SMDL Series Size: 0201/0402/0603/0805/1206/1010/2010/2512/1225/3720/7520. official distributor of

2R2. 2 (L W H) [mm] Wire Wound SMD Power Inductor. Nominal Inductance Packing Tape & Reel. Design Code M ±20%

Sunlord. Wire Wound SMD Power Inductors SWCS Series SWCS XXXX -XXX T. Operating Temperature: -25 ~ +105 FEATURES APPLICATIONS PRODUCT IDENTIFICATION

1000 VDC 1250 VDC 125 VAC 250 VAC J K 125 VAC, 250 VAC

Halogen free Shipboard Cable IEC , 353, 354, 376

Metal Oxide Varistor (MOV) Data Sheet

Capacitors - Capacitance, Charge and Potential Difference

Data sheet Thick Film Chip Resistor 5% - RS Series 0201/0402/0603/0805/1206

Metal Oxide Leaded Film Resistor

BMA SERIES Subminiature Blind Mate Connectors

SMD Wire Wound Ferrite Chip Inductors - LS Series. LS Series. Product Identification. Shape and Dimensions / Recommended Pattern LS0402/0603/0805/1008

MAX-QUALITY ELECTRIC CO; LTD Thin Film Precision Chip Resistors. Data Sheet

High pressure centrifugal pumps

RF series Ultra High Q & Low ESR capacitor series

TTX400 TL5, TMX400 electrical units

(1) Describe the process by which mercury atoms become excited in a fluorescent tube (3)

Daewoo Technopark A-403, Dodang-dong, Wonmi-gu, Bucheon-city, Gyeonggido, Korea LM-80 Test Report

ΤΕΙ ΚΑΒΑΛΑΣ ΣΧΟΛΗ ΤΕΧΝΟΛΟΓΙΚΩΝ ΕΦΑΡΜΟΓΩΝ ΤΜΗΜΑ ΗΛΕΚΤΡΟΛΟΓΙΑΣ ΠΤΥΧΙΑΚΗ ΕΡΓΑΣΙΑ

Polymer PTC Resettable Fuse: KRG Series

2013 REV 01 ELECTRONICS CAPACITORS. DC Applications Metallized Polypropylene Film Self Healing

FDL - FXDL FBDL SERIES

CSK series. Current Sensing Chip Resistor. Features. Applications. Construction FAITHFUL LINK

Ceramic PTC Thermistor Overload Protection

Smaller. 6.3 to 100 After 1 minute's application of rated voltage at 20 C, leakage current is. not more than 0.03CV or 4 (µa), whichever is greater.

LS series ALUMINUM ELECTROLYTIC CAPACITORS CAT.8100D. Specifications. Drawing. Type numbering system ( Example : 200V 390µF)

Unshielded Power Inductor / PI Series

TTX400 TL5, TMX400 electrical units

GAUGE BLOCKS. Grade 0 Tolerance for the variation in length. Limit deviation of length. ± 0.25μm. 0.14μm ±0.80μm. ± 1.90μm. ± 0.40μm. ± 1.

Surface Mount Multilayer Chip Capacitors for Commodity Solutions

CERAMIC DISC CAPACITOR Class II 50V,100V,500V,1KV,2KV,3KV, Hi-K Type

Metal Oxide Leaded Film Resistor

Cable Systems - Postive/Negative Seq Impedance

ACTORS IEC CONT Ex9C

a brand of Bel Lighting group

Cables. Marine and Offshore Electrical Supply Pg 21 ORDERLINE P5/P12 BFOU 0.6/1kV

Chapter 7 Transformations of Stress and Strain

Aerovox Corp. Type H High Voltage AC & DC Capacitors. Film Capacitors for Power Electronics Applications. RoHS Compliant. Highlights.

0.635mm Pitch Board to Board Docking Connector. Lead-Free Compliance

MMCX SERIES Microminiature Coaxial Connectors

RJ45-patch cable Cat.7, 600 MHz, 10 GBit/s Corning FutureCom TM S/FTP flex/26 + Hirose TM31

ΤΑΥΤΟΤΗΤΑ IDENTITY Τσουμάνης ΑΒΕΕ

Transcript:

Elki Cable is one of Turkey's leading companies in its sector and produces cables in accordance with international quality standards. Elki Cable has been founded in 983 and since 986, it has been producing cables under "IRMAK KABLO" brand name. The company has satisfied customers over the years by focusing on quality and timeliness of delivery. Various cables used in appliances, consumer electronics products, PC's, and energy transmission are produced in accordance with the ISO 900:000 quality system. All ranges of cables have TSE (Institute of Turkish Standards) and HAR certificates, enabling us to export 30% of our production to the following countries: The Netherlands, the United Kingdom, Germany, Austria, Bulgaria, Romania, Ukraine, Georgia, Iraq, Lebanon, Guinea. Elki has 00 squaremeters covered production space in Istanbul and Manisa with 0 employees. PVC used in cables is also produced in house, while copper is supplied from local vendors. Our annual production capacity is 3000 tons for copper and 4000 tons for PVC. Beside the cables represented in this catalogue, we are also ready to meet any of your special requirements.

Rigid single core cables for internal wiring H05V-U Nominal Ave. Outer Max. resistance cross-section min. max. at 0 C 0,9,3 36,0 9 5 8,,5 4,5,3,,7 8, 5 Nominal Ave. Outer Max. resistance cross-section min. max. at 0 C,5,38,6 3,,0 9,5,78 3, 3,4 7,4 30 4,6 3,6 4,4 4,6 47 6,76 3,8 5,0 3,08 68 H07V-U Product Description Applications - Solid or stranded copper conductor - Color-coded PVC insulation - Rated Temperature: 70 C - Rated Voltage: H05V-U: 300V / 500V H07V-U: 450V / 750V - Fixed protected installation inside appliances and in or on lighting fittings. -Suitable for installation in mounted or embedded conduits, only for signalling or control circuits.

Flexible single core cables for internal wiring H05V-K Cross Section No. & Outer Max. resistance min. max. at 0 C 6x0.9,,5 39,0 8 5 4x0.9,,7 6,0 3x0.9,4,8 9,5 5 Max. resistance H07V-K Cross Section No. & Outer min. max. at 0 C,5 7x0.5,8 3,4 3,30 0,5 45x0.5 3,4 4, 7,98 3 4 56x0.9 3,9 4,8 4,95 5 6 84x0.9 4,4 5,3 3,30 75 0 x0.39,0 5,7 6,8,9 7 6 6x0.39,0 6,7 8,, 85 5 00x0.39, 8,4 0, 8 300 35 x0.39, 9,7,7 0.554 440 50 400x0.39,4,5 3,9 0.386 590 70 560x0.39,4 3, 6,0 0.7 830 95 760x0.39,6 5, 8, 0.06 00 Product Description Applications - Flexible copper conductor - Color-coded PVC insulation - Rated Temperature: 70 C - Rated Voltage: H05V-K: 300V / 500V H07V-K: 450V / 750V - For internal wiring in electrical equipment where small bending radius is required.

Flexible multi-core cables H03VV-F Jacket Cross Section No. & Outer Max. resistance min. max. at 0 C x0.50 6x0.9 4,6 5,9 39 45 x0.75 4x0.9 4,9 6,3 6 50 3G0.50 6x0.9 4,9 6,3 39 55 3G0.75 4x0.9 5, 6,7 6 65 4G0.50 6x0.9 5,4 6,9 39 70 4G0.75 4x0.9 5,7 7,3 6 Product Description Applications - Bare stranded copper conductor - Color-coded PVC insulation - Cores twisted together - PVC jacketed cord, flat type - Rated Temperature: 70 C - Rated Voltage: 300V / 300V - Suitable for light moveable equipment, in houses and offices (wiring for light portable appliances, which are subject to slight mechanical stress) - Also suitable where good flexibility is required, provided there is no risk of mechanical damage. - For connectionof household appliances, radio and TV sets and electrical devices to power supply networks with rated voltage U0/U 300/300V

Flexible multi-core cables H05VV-F Jacket Cross Section No. & Outer Max. resistance min. max. at 0 C x0.75 4x0.9 5,7 7, 6 53 x.00 3x0.9 5,9 7,5 9,5 69 x.50 7x0.5 6,8 8,6 3,3 83 x.50 45x0.5,0 8,4 7.98 3 x4.00 56x0.9, 9,7, 4.95 0 3G0.75 4x0.9 6,0 7,6 6 73 3G.00 3x0.9 6,3 8,0 9,5 86 3G.50 7x0.5 7,4 9,4 3,3 07 3G.50 45x0.5, 9,,4 7.98 65 3G4.00 56x0.9, 3, 4.95 50 4G0.75 4x0.9 6,6 8,3 6 89 4G.00 3x0.9 7, 9,0 9.5 04 4G.50 7x0.5,0 8,4 3.3 36 4G.50 45x0.5, 0,,5 7.98 05 4G4.00 56x0.9,,5 4,3 4.95 307 5G0.75 4x0.9 7,4 9,3 6 99 5G.00 3x0.9 7,8 9,8 9.5 07 5G.50 7x0.5, 9,3,6 3.3 8 5G.50 45x0.5,, 3,9 7.98 56 5G4.00 56x0.9,4 3,0 6, 4.95 3 Product Description Applications - Flexible copper conductor - Color-coded PVC insulation - Cores twisted together - For connectionof household and office appliances, electrical tools and devices to power supply networks with rated voltage U0/U 300/500V - PVC jacketed cord, flat type - Rated Temperature: 70 C - Rated Voltage: 300V / 500V - For domestic appliances in damp conditions (washing machines, hairdryers, refrigerators, etc) - Permitted for domestic heating appliances provided they do not come into contact with sources of heat or radiation

Flat-shaped flexible multi-core cables H03VVH-F Cross Section No. & Max. resistance Jacket Outer min. max. at 0 C x0.50 6x0.9 3.0x4.9 3.7x5.9 39 45 x0.75 4x0.9 3.x5. 3.8x6.3 6 50 Product Description Applications - Bare stranded copper conductor - Color-coded PVC insulation - PVC jacket cord - Rated Temperature: 70 C - Rated Voltage: 300V / 300V -Suitable for light moveable equipment, in houses and offices (wiring for light portable appliances which are subject to slight mechanical stress) - Also suitable where good flexibility is required, provided there is no risk of mechanical damage. - For connection of household appliances, radio and TV sets and electrical devices to the power supply networks with rated voltage U0/U 300/300V H05VVH-F Cross Section No. & Jacket Outer Max. resistance min. max. at 0 C x0.75 4x0.9 3.7x6.0 4.7x7. 6 36 x.00 3x0.9 3.9x6. 4.7x7.5 9,5 45 Product Description Applications - Bare stranded copper conductor - Color-coded PVC insulation - PVC jacket cord, flat type - Rated Temperature: 70 C - Rated Voltage: 300V / 500V - In household and office appliances which are subject to medium mechanical stress. - For domestic appliances in damp conditions (washing machines, hairdryers, refrigerators, etc) - Permitted for domectic heating appliances provided they do not come into contact with sources of heat or radiation.

Single-core non-sheathed cables for internal wiring H05V-K Cross Section No. & Max. resistance min. Outer max. at 0 C 6x0.9,,5 39 9 5 4x0.9,,7 6,5 3x0.9,4,8 9,5 4, TS HD.7 S H07V-K Cross Section No. & Max. resistance min. Outer max. at 0 C,5 7x0.5,8 3,4 3,30 9,5 45x0.5 3,4 4, 7,98 30 4 56x0.9 3,9 4,8 4,95 45 6 84x0.9 4,4 5,3 3,30 63 0 x0.39,0 5,7 6,8,9 0 6 6x0.39,0 6,7 8,, 65 5 00x0.39, 8,4 0, 8 55 35 x0.39, 9,7,7 0.554 345 TS HD.7 S Product Description Applications - Bare stranded copper conductor - Color-coded PVC insulation - Rated Temperature: 90 C - Rated Voltage: H05V-K: 300V / 500V H07V-K: 450V / 750V - Suitable for internal wiring and insallation inside appliances and lighting fittings.

Single-core non-sheathed cables for general purposes H05V-R Cross Section No. & Max. resistance min. Outer max. at 0 C 7x0.30,,5 36 9 5 7x0.37,,7 4,5 7x0.43,4,8 8, 5 H07V-R Cross Section No. & Max. resistance min. Outer max. at 0 C,5 7x0.5,8 3,4,0,5 7x0.66 3,4 4, 7,4 35 4 7x0.83 3,9 4,8 4,6 50 6 7x.0 4,4 5,3 3,08 7 0 7x.34,0 5,7 6,8 3 0 6 7x.70,0 6,7 8,,5 5 7x.0, 8,4 0, 7 35 7x.55, 9,7,7 4 3 Product Description Applications - Seven wire, bare copper conductor - Color-coded PVC insulation - Rated Temperature: 70 C - Rated Voltage: H05V-R: 300V / 500V H07V-R: 450V / 750V - Suitable for fixed protected installation inside appliances and in lighting fittings.

FLRY-A Application : Low voltage thin wall cables for vehicles Rated Temperature : - 40 C to + 05 C(3000 h) : Soft annealed plain copper (Type A) : Class B (05 C) PVC and RoHS Compliant Standard : ISO 67 Nominal Number of wires cross-section and max. diameter max. diameter Max. resistance thickness Cable Outside at 0 C nom. min. max. diameter (no x mm) 0, 7 x 0, 0 84,40 0,0,0,6 0,35 7 x 0,6 0 54,40 0,0,40 4,5 9 x,0 37,0 0,8 0,,70 6,6 5 9 x 0,3,30 4,70 0,30 0,4,90 9 9 x 0,6,50 8,50 0,30 0,4,0,5 9 x 0,3 0,70 0,30 0,4,40 6 9 x 0,37,00 9,4 0,35 0,8,,5 9 x 0,4,0 7,60 0,35 0,8 3,00 6

FLRY-B Application : Low voltage thin wall cables for vehicles Rated Temperature : - 40 C to + 05 C(3000 h) : Soft annealed plain copper (Type B) : Class B (05 C) PVC and RoHS Compliant Standard : ISO 67 Nominal Number of wires cross-section and max. diameter max. diameter Max. resistance thickness Cable Outside at 0 C nom. min. max. diameter (no x mm) 0, 7 x 0, 0 84,40 0,0,0,6 0,35 x 0, 0 54,40 0,0,40 4,5 6 x 0,,0 37,0 0,8 0,,70 6,6 5 4 x 0,,30 4,70 0,30 0,4,90 9 3 x 0,,50 8,50 0,30 0,4,0,5 30 x 0,6 0,70 0,30 0,4,40 6 8 x 0,3,00 9,4 0,35 0,8,,5 50 x 0,6,0 7,60 0,35 0,8 3,00 6 3 44 x 0,3,40 6,5 0,40 0,3 3,40 33 4 56 x 0,3, 4,7 0,40 0,3 3, 4 5 70 x 0,3 3,0 3,94 0,40 0,3 4,0 54 6 84 x 0,3 3,40 3,4 0,40 0,3 4,30 6 0 x 0,4 4,50 0 0, 6,00 08 6 6 x 0,4 6,30,6 5 7,90 70 5 96 x 0,4 7, 43 5 9,40 60

FLY Application : Low voltage thick wall cables for vehicles Rated Temperature : - 40 C to + 05 C(3000 h) : Soft annealed plain copper : Class B (05 C) PVC and RoHS Compliant Standard : ISO 67 Nominal Number of wires cross-section and max. diameter max. diameter Max. resistance thickness Cable Outside at 0 C nom. min. max. diameter (no x mm) 6 x 0,,0 37,0 0 0,,30 8 5 4 x 0,,30 4,70 0 0,,50 3 x 0,,50 8,50 0 0,,70 4,5 30 x 0,6 0,70 0 0, 3,00 9 8 x 0,3,00 9,4 0 0, 3,30 6,5 50 x 0,6,0 7,60 0 6 3,60 3 3 44 x 0,3,40 6,5 0 6 4,0 36 4 56 x 0,3, 4,7 0 4 4,40 5 70 x 0,3 3,0 3,94 0 4 4,90 6 6 84 x 0,3 3,40 3,4 0 4 5,00 68 0 x 0,4 4,50,00 0 6,50 5 6 6 x 0,4 6,30,6,00 0 8,30 85 5 96 x 0,4 7, 43,30,04 0,40 90 35 76 x 0,4 9,00 7,30,04,60 3 50 396 x 0,4 0 0,368,50,0 3,50 530 70 360 x,50 9,50,0 5,50 70 95 475 x 4, 6,60,8 8,00 9 0 608 x 6,50 3,60,8 9,70 50

FLRYW Application : Low voltage thin wall cables for vehicles Rated Temperature : - 40 C to + 5 C(3000 h) : Soft annealed plain copper : Class C (5 C) PVC and RoHS Compliant Standard : ISO 67 Nominal Number of wires cross-section and max. diameter max. diameter Max. resistance thickness Cable Outside at 0 C nom. min. max. diameter (no x mm) 0, 7 x 0, 0 84,40 0,0,0,6 0,35 x 0, 0 54,40 0,0,40 4,5 6 x 0,,0 37,0 0,8 0,,70 6,6 5 4 x 0,,30 4,70 0,30 0,4,90 9 3 x 0,,50 8,50 0,30 0,4,0,5 30 x 0,6 0,70 0,30 0,4,40 6 8 x 0,3,00 9,4 0,35 0,8,,5 50 x 0,6,0 7,60 0,35 0,8 3,00 6 3 44 x 0,3,40 6,5 0,40 0,3 3,40 33 4 56 x 0,3, 4,7 0,40 0,3 3, 4 5 70 x 0,3 3,0 3,94 0,40 0,3 4,0 54 6 84 x 0,3 3,40 3,4 0,40 0,3 4,30 6 0 x 0,4 4,50 0 0, 6,00 08 6 6 x 0,4 6,30,6 5 7,90 70 5 96 x 0,4 7, 43 5 9,40 60

AVSS Application : Low voltage super thin wall cables for vehicles Rated Temperature : - 40 C to + 05 C(3000 h) : Soft annealed plain copper : Class B (05 C) PVC and RoHS Compliant Standard : JASO D 6 Nominal Number of wires cross-section and max. diameter max. diameter Max. resistance thickness Cable Outside diameter at 0 C nom. min. nom. max. (no x mm) 0,3 7 x 0,6 0 50,0 0,30 0,4,40,50 5 0,3 f 9 x 0,6 0, 0,30 0,4,40,50 5 7 x 0,3,00 3,70 0,30 0,4,60,70 7 f 9 x,00 34,60 0,30 0,4,60,70 7 5 f 9 x 0,3,0 3,60 0,30 0,4 0,90 9,5 5 9 x 0,4,0,70 0,30 0,4 0,90 0,5 9 x,50 4,90 0,30 0,4,0,0 4,5 f 37 x 0,,50 4,60 0,30 0,4,0,0 4 f 37 x 0,6 0 9,50 0,40 0,3,60,70

AVS Application : Low voltage thin wall cables for vehicles Rated Temperature : - 40 C to + 05 C(3000 h) : Soft annealed plain copper : Class B (05 C) PVC and RoHS Compliant Standard : JASO D 6 Nominal Number of wires cross-section and max. diameter max. diameter Max. resistance thickness Cable Outside diameter at 0 C nom. min. nom. max. (no x mm) 0,3 7 x 0,6 0 50,0 0 0,40 0,90 6 0,3 f 5 x 0,8 0,90 0 0,40 0,90 6 7 x 0,3,00 3,70 0 0,40,00,0 8 f 0 x 0,8,00 36,70 0 0,40,00,0 8 5 f 30 x 0,8,0 4,40 0 0,40,0,30 5 x 0,3,0 0 0 0,40,0,30,5 6 x 0,3,50 4,30 0 0,40,50,60 6,5 f 50 x 0,8,50 4,70 0 0,40,50,60 6 6 x 0,3,90 8,8 0 0,40,90 3,0 4 f 37 x 0,6 0 9,50 0 0,40,,90 4 3 4 x 0,3,40 5,59 0 0, 3,60 3, 38 5 65 x 0,3 3,00 3,5 0 6 4,40 4,60 58

AV Application : Low voltage thick wall cables for vehicles Rated Temperature : - 40 C to + 05 C(3000 h) : Soft annealed plain copper : Class B (05 C) PVC and RoHS Compliant Standard : JASO C 3406 Nominal Number of wires cross-section and max. diameter max. diameter Max. resistance thickness Cable Outside diameter at 0 C nom. min. nom. max. (no x mm) 7 x 0,3,00 3,70 0 0,,0,40 0 f 0 x 0,8,00 36,70 0 0,,0,40 9 5 f 30 x 0,8,0 4,40 0 0,,40,60 5 x 0,3,0 0 0 0,,40,60 3,5 6 x 0,3,50 4,30 0 0,,70,90 8,5 f 50 x 0,8,50 4,70 0 0,,70,90 7 6 x 0,3,90 8,8 0 0, 3,0 3,40 6 f 37 x 0,6 0 9,50 0 0, 3,00 3,40 5 3 4 x 0,3,40 5,59 0 6 3, 4,0 40 3f 6 x 0,6,40 5,76 0 6 3, 4,0 40 5 65 x 0,3 3,00 3,5 0 4 4,60 4,90 60 8 50 x 0,45 3,70,3 0 5,50 5, 90 0 63 x 0,45 4,50 4,00 0 6,50 6,90 0 5 84 x 0,45 5,40,38,0 8 7,60 8,00 50 0 4 x 0 6,0 87,0 8 8,30 8, 0 30 70 x 0 8,00 0,40, 0,50 3 40 85 x 0 8,60 0,,40,,40,0 455 50 08 x 0 9, 0,337,60,8 3,00 3, 5

ANV Cables with thick isolation Cross Section No. & 6x0.9 5 4x0.9 3x0.9,5 7x0.5,5 45x0.5 4 56x0.9 6 84x0.9 0 x0.39 6 6x0.39 5 96x0.39 35 76x0.39 50 396x0.39 70 360x0.49 95 475x0.49 0 608x0.49 Nominal Min. 0,44 0,44 0,44 0,44 3,0 0,0 0,3,07,3,07,5,5,5,5,6,34,6,34 Outer min. max.,3,,5,3,7,6 3,0 3, 3,6 3,9 4,4 4,5 5,0 5,7 6,5 7, 8,3 9,6 0,4,6,3 3,5 5,0 5,5 7,5 8,0 9, 9,7 Max. resistance at 0 C 37, 4,7 8,5,7 7,6 4.7 3.4.8.6 0.743 0.57 0.368 0.59 0.96 0.53 8 5 0 3 5 75 7 85 300 440 590 830 00 30 Outer min. max.,,3,,5,6,9,7,,9,3,,6,4,8,6 3,0 3,0 3,4 3,3 3,8 3,7 4, 3,9 4,5 5, 6,0 6,9 7,9 8,5 9,4 Max. resistance at 0 C 84,8 54,4 37, 4,7 8,5,7 9.4 7,6 6 4.7 3.94 3.4.8.6 0.757 3,3 4,5 7,3 9,6 8 3 8 34 44 56 64 08 79 Cables with thin isolation Cross Section No. & 0, 7x0.0 0,35 x0.0 6x0.9 5 4x0.9 3x0.9,5 7x0.5 8x0.9,5 45x0.5 3 44x0.9 4 56x0.9 5 70x0.9 6 84x0.9 0 x0.39 6 6x0.39 5 96x0.39 Nominal Min. 0,30 0,4 0,30 0,4 0,35 0,8 0,35 0,8 0,35 0,8 0,35 0,8 0,35 0,8 0,35 0,8 0,40 0,3 0,40 0,3 0,45 0,36 0,45 0,36 0 0, 5 5

Silicone Cables NGFAF flexible Cross Section 5,5,5 4 6 0 6 Nom.,0, Outer min.,,4,5,9 3,5 4, 5, 6,4 8,0 9,5 5,, 3,7 5,3, 9,7 05,5 Outer min.,0,,3,6 3, 8,7,6 4,5 9,9 3,3 NGFA rigid Cross Section 5,5,5 Nom. Rated Temperature: -60 C / + C

Halogen-free flexible single core cables 05Z-K Cross Section No. & 6x0.9 5 4x0.9 3x0.9 Outer,9,3,4 Max. resistance at 0 C 39,0 6,0 9,5 8 4 0 0 0 0,00,00,0,0,40,40,60 Outer,9 3,5 4, 4,8 6,0 7, 8,8 9,7,5 3,3 5,4 Max. resistance at 0 C 3,30 7,98 4,95 3,30,9, 8 0.554 0.386 0.7 0.06 0 3 46 66 09 69 60 343 499 683 93 07Z-K Cross Section No. &,5 7x0.5,5 45x0.5 4 56x0.9 6 84x0.9 0 x0.39 6 6x0.39 5 00x0.39 35 x0.39 50 400x0.39 70 560x0.39 95 760x0.39 Product Description Applications - Flexible copper conductor - Halogen-free thermoplastic insulation - Rated Temperature: 70 C - Rated Voltage: 05Z-K: 300V / 500V 07Z-K: 450V / 750V - Suitable for populated locations with fire risk, such as shopping centers, hotels, schools, business centers, etc.

Halogen-free rigid and flexible single core cables 07Z-U Cross Section No. &,5 x.38,5 x.78 4 x.6 6 x.76 Outer,8 3,4 3,8 4,3 Max. resistance at 0 C, 7,4 4,6 3,08 0 3, 45 63,7 0 0 0 0,00,00,0,0 Outer 3,0 3,6 4, 4,7 5,9 7,0 8,4 9,4 Max. resistance at 0 C,0 7,4 4,6 3,08 3,5 7 4,4 3,8 47,6 67,7 09, 67,5 6, 347,8 07Z-R Cross Section No. &,5 7x0.5,5 7x0.66 4 7x0.83 6 7x.0 0 7x.34 6 7x.70 5 7x.0 35 7x.55 Product Description Applications - Rigid or flexible copper conductor - Halogen-free thermoplastic insulation - Rated Temperature: 70 C - Rated Voltage: 450V / 750V - Suitable for populated locations with fire risk, such as shopping centers, hotels, schools, business centers, etc.

Halogen-free flexible multi-core cables H03ZZ-F Cross Section No. & x0.50 6x0.9 x0.75 4x0.9 3G0.50 6x0.9 3G0.75 4x0.9 4G0.50 6x0.9 4G0.75 4x0.9 Jacket Outer 5,0 5,4 5,4 5,8 5,8 6,3 Max. resistance at 0 C 39 6 39 6 39 6 Product Description Applications - Flexible copper conductor - Halogen-free thermoplastic insulation - Halogen-free thermoplastic jacket - Rated Temperature: 70 C - Rated Voltage: 300V / 300V - Suitable for populated locations with fire risk, such as shopping centers, hotels, schools, business centers, etc. 38 46 45 56 55 70

Halogen-free flexible multi-core cables H05ZZ-F Cross Section No. & x0.75 4x0.9 x.00 3x0.9 x.50 7x0.5 x.50 45x0.5 x4.00 56x0.9 3G0.75 4x0.9 3G.00 3x0.9 3G.50 7x0.5 3G.50 45x0.5 3G4.00 56x0.9 4G0.75 4x0.9 4G.00 3x0.9 4G.50 7x0.5 4G.50 45x0.5 4G4.00 56x0.9 5G0.75 4x0.9 5G.00 3x0.9 5G.50 7x0.5 5G.50 45x0.5 5G4.00 56x0.9 Jacket,0,,,,0,,4,,,4 Outer 6, 6,4 7,4 9,0 0,4 6,6 6,8 8, 9,8,3 7, 7,6 9,0,7 8, 8,3 0,,9 3,9 Max. resistance at 0 C 6 9,5 3,3 7.98 4.95 6 9,5 3,3 7.98 4.95 6 9.5 3.3 7.98 4.95 6 9.5 3.3 7.98 4.95 Product Description Applications - Flexible copper conductor - Halogen-free thermoplastic insulation - Halogen-free thermoplastic jacket - Rated Temperature: 70 C - Rated Voltage: 300V / 500V - Suitable for populated locations with fire risk, such as shopping centers, hotels, schools, business centers, etc. 57 64 85 8 78 67 76 07 60 4 8 98 36 98 9 99 4 6 38 34

Telephone cables VDV x x 0.40 + 0.40 VDV x x 0.40 + 0.40 VDV 3 x x 0.40 + 0.40 VDV 4 x x 0.40 + 0.40 VDV 5 x x 0.40 + 0.40 VDV 6 x x 0.40 + 0.40 VDV 0 x x 0.40 + 0.40 VDV 5 x x 0.40 + 0.40 VDV 0 x x 0.40 + 0.40 VDV 30 x x 0.40 + 0.40 VDV 50 x x 0.40 + 0.40 VDV 00 x x 0.40 + 0.40 VDV x x 0.50 + 0.50 VDV x x 0.50 + 0.50 VDV 3 x x 0.50 + 0.50 VDV 4 x x 0.50 + 0.50 VDV 5 x x 0.50 + 0.50 VDV 6 x x 0.50 + 0.50 VDV 0 x x 0.50 + 0.50 VDV 5 x x 0.50 + 0.50 VDV 0 x x 0.50 + 0.50 VDV 30 x x 0.50 + 0.50 VDV 50 x x 0.50 + 0.50 VDV 00 x x 0.50 + 0.50 VDV x x 0.60 + 0.60 VDV x x 0.60 + 0.60 VDV 3 x x 0.60 + 0.60 VDV 4 x x 0.60 + 0.60 VDV 5 x x 0.60 + 0.60 VDV 6 x x 0.60 + 0.60 VDV 0 x x 0.60 + 0.60 VDV 5 x x 0.60 + 0.60 VDV 0 x x 0.60 + 0.60 VDV 30 x x 0.60 + 0.60 VDV 50 x x 0.60 + 0.60 VDV 00 x x 0.60 + 0.60 VDV x x 0.90 + 0.90 VDV x x 0.90 + 0.90 VDV 3 x x 0.90 + 0.90 VDV 4 x x 0.90 + 0.90 VDV 5 x x 0.90 + 0.90 VDV 6 x x 0.90 + 0.90 VDV 0 x x 0.90 + 0.90 VDV 5 x x 0.90 + 0.90 VDV 0 x x 0.90 + 0.90 VDV 30 x x 0.90 + 0.90 VDV 50 x x 0.90 + 0.90 VDV 00 x x 0.90 + 0.90 VDV Product Description Applications - Bare or tinned copper conductor - Color-coded PVC insulation - PVC jacket cord, flat type - These cables are used for signal transmission at fixed indoor installations.

Underground buried type communication cables PD-PAP x x 0.40 PD-PAP 4 x x 0.40 PD-PAP 6 x x 0.40 PD-PAP 0 x x 0.40 PD-PAP 0 x x 0.40 PD-PAP 30 x x 0.40 PD-PAP 50 x x 0.40 PD-PAP x x 0.50 PD-PAP 4 x x 0.50 PD-PAP 6 x x 0.50 PD-PAP 0 x x 0.50 PD-PAP 0 x x 0.50 PD-PAP 30 x x 0.50 PD-PAP 50 x x 0.50 PD-PAP x x 0.60 PD-PAP 4 x x 0.60 PD-PAP 6 x x 0.60 PD-PAP 0 x x 0.60 PD-PAP 0 x x 0.60 PD-PAP 30 x x 0.60 PD-PAP 50 x x 0.60 PD-PAP x x 0.90 PD-PAP 4 x x 0.90 PD-PAP 6 x x 0.90 PD-PAP 0 x x 0.90 PD-PAP 0 x x 0.90 PD-PAP 30 x x 0.90 PD-PAP 50 x x 0.90 PD-PAP Product Description Applications - Annealed copper conductors - Foam-Skim PE insulation - Star quad construction - PE inner sheath - Aluminum foil (double side copolymer coated) - PE outer sheath - Telephone cables for VF transmission and digital systems. - Suitable for direct burial.

Drop wire with steel supporting wire BAP-DT x 0. +.0 x.00 +.40 x.36 +.40 x.76 +. Product Description Applications - Two copper conductors with supporting steel wire in center. - PVC insulation - These cables are designed for telephone subscriber connections as exterior installation, especially in rural areas or long distance subscriber connections.

Data, diaphone and speaker cables Data cables x 0.mm....5mm 3 x 0.mm....5mm 4 x 0.mm....5mm 5 x 0.mm....5mm 6 x 0.mm....5mm 8 x 0.mm....5mm 0 x 0.mm....5mm x 0.mm....5mm 4 x 0.mm....5mm 6 x 0.mm....5mm 8 x 0.mm....5mm 0 x 0.mm....5mm x 0.mm....5mm 4 x 0.mm....5mm Diaphone cables 4 x 0.mm 6 x 0.mm 8 x 0.mm 0 x 0.mm x 0.mm Product Description - Bare stranded copper conductor - Color-coded PVC insulation - PVC jacket cord Speaker cables

Coaxial cables Coaxial cables RG 59 U / 4 RG 6 U / 4 RG 58 A / U RG U / 4 TWINAXIAL 00 Product Description Applications - Tinned or bare copper conductors. - PE or FPE insulation - Aluminum shield - PVC jacket - 75 ohm cable suitable for TV systems or satellite receivers.

Flat cables Flat cables Product Description Copper: 7x0.0mm or 0.50mm Number of conductors: 4 Minimum isolation thickness: 0.40mm Rated temperature: 70 C Rated voltage: 300V If requested, a stripe on leading edge is possible

NYM Application: In dry, damp and wet locations on premises and in store rooms with fire and explosion hazard. Can be used outdoors but cannot be buried underground. Techinical data:.5mm 0mm are single-core, 0 and 6mm are multi-core. is TI thermoplastic. Twisted. Outer sheath color is grey. Max. conductor temperature: 70 C Rated voltage: 300/500V Rated Number of Outer Sheath Outer Resistance Crosssection Strands at 0 C x.5,38,4 8 6, x.5 0,4 0 60 7,8 x4,6,4,4 8 4,56 x6,,4,4 77 3,03 x0-7 4,0,0,6 6,4 8 3 x6-7 5,0,0,6 8,6 600,5 3x.5,38,4 9, 36, 3x.5 0,4 89 7,8 3x4,6,4 6 4,56 3x6,,6 3,5 353 3,03 3x0-7 4,0,0,6 7,4 60 3 3x6-7 5,0,0,6 0 856,5 4x.5,38,4 0 63, 4x.5 0,4,3 3 7,8 4x4,6,6 3,4 36 4,56 4x6,,6 5 45 3,03 4x0-7 4,0,,6 9 746 3 4x6-7 5,0,0,6 07,5

YVV(NYY) Application: Power cable, underground, in ducts, indoors and outdoors, in pure or salt water, for power stations industrial plants and switching stations. Technical data:,,3 or 4 cores. Solid conductor between.5 and 0mm; stranded copper conductor between 0 and 400mm. Cores are twisted together and covered with an inner covering and black outer sheath. Max. conductor temperature: 70 C Rated voltage: 0.6/kV Rated Number of Outer Sheath Outer Resistance Crosssection Strands at 0 C Rated Current Ground Air x4,6,5 8,9 4,47 65 46 0 x6,8,5 9,4,97 83 58 40 x0-7 4,,5,79 0 95 x6-7 5,,5,7, 45 05 70 x5 7 6,4,5,9 90 40 370 x35 7-9 7,7,5 4, 4 35 75 4 x50 9 9,,5 5,6 0,379 5 640 x70 9,5 7, 0,6 350 70 850 x95 9-37,7,6 9,4 0,89 40 335 5 x0 37 4,4,6,4 4 390 340 x50 37 6, 3 0, 540 445 660 x85 37 8,0 5,7 0,097 60 50 030 x40 6, 9 0,0740 770 60 650 x.5,38, 30 x.5 3 7,8 4 9 0 x4,6,0 4 4,56 53 38 90 x6,8,0 5 3,03 66 350 x0-7 4,,0 7 3 88 66 4 x6-7 5,,0 8,5 5 90 640 x5 7 6,4, 7 50 0 000 x35 7-9 7,7, 6 4 50 390 x50 9 9,,4 9 0,387 0 90 x70 9,4, 35 0,68 60 30 640 x95 9,7,6, 39 3 35 75 3360 x0 37 4,4,6,4 43 3 360 30 400 x50 37 6,,6 0,4 400 375 550 x85 37 8,6,0,6 5 0,099 460 430 640 x40 6, 3 59 0,075 530 50

YVV(NYY) cont. Rated Number of Outer Sheath Outer Resistance Crosssection Strands at 0 C,38,5 Rated Current Ground Air, 7 8 90 3x.5 3x.5,5 7,4 36 5 60 3x4,6,0 4,5 4,6 46 34 340 3x6,8,0 5,5 3,08 58 44 40 3x0-7 4,,0 7 30 77 60 5 3x6-7 5,,0 0,50 00 840 3x5 7 6,4, 4,5 7 30 05 330 3x35 7-9 7,7, 7 4 55 30 730 3x50 9 9,,4 3 0,387 85 60 300 3x70 9,4, 36 0,68 30 00 3300 3x95 7,7,6, 4 3 75 45 400 3x0 37 4,4,6, 43,5 3 35 85 5300 3x50 37 6,,6 49,5 0,4 355 35 6500 3x85 37 8,0,6 54,5 0,099 400 370 00 3x40 6, 3 6 0,0754 445 435 000 3x6+0 7 5,,0,5 00 973 3x5+6 7 6,4./ 5 7 30 05 560 3x35+6 7-9 7,7./ 8 4 55 30 90 3x50+5 9 9,.4/., 3 0,387 85 60 850 3x70+35 9.4/., 38 0,68 30 00 3690 3x95+50 9,7.6/.4, 44,5 3 375 45 70 3x0+70 37 4,4.6/.4,6 3 35 85 6060 3x50+70 37 6,.8/.4,8 5 0,4 355 35 770 3x85+95 37 8.0/.6 3 59 0,099 400 370 900 3x40+0 6-37./.6 3, 66 0,0754 460 435 60 4x.5,38 3,00 7 8 30 4x.5 4 7,8 36 5 300 4x4,6,0 6 4,56 46 34 40 4x6,8,0 7 3,03 58 44 50 4x0-7 4,,0 0 3 77 60 7 4x6-7 5,,0 3,5 00 00 4x5 7 6,4, 7 7 30 05 600 4x35 7-9 7,7,, 3 4 55 30 00 4x50 9 9,,4, 36 0,387 85 60 3030 4x70 9,4, 40 0,68 30 00 40 4x95 9,7,6, 44 3 75 54 553 4x0 37 4,4,6,6 50 3 35 85 6764 4x50 37 6,,6 54 0,4 355 35 870 4x85 37 8,0 3 6 0,099 400 370 07 4x40 6, 3 69 0,0754 455 435 39

YVV(NYY) Control Cables Application: Power cable, underground, in ducts, indoors and outdoors, in pure or salt water, for power stations industrial plants and switching stations. Technical data: More than four.5 or.5mm wires are twisted together. s are insulated with PVC, twisted together and covered with inner and outer sheaths. Max. conductor temperature: 70 C Rated voltage: 0.6/kV Rated Number of Outer Sheath Outer Resistance Crosssection Strands at 0 C 5x.5,38 3, 60 7x.5,38 4, 30 0x.5,38 7, 430 x.5,38 8, 445 4x.5,38 9, 4 6x.5,38 0, 550 9x.5,38, 600 x.5,38, 700 4x.5,38 5, 0 30x.5,38 6, 90 40x.5,38 8, 300 5x.5 6 7,8 360 7x.5 6 7,8 440 0x.5 7,8 550 x.5 7,8 600 4x.5 7,8 675 6x.5 7,8 750 9x.5 3 7,8 850 x.5 4 7,8 90 4x.5 7 7,8 050 30x.5 8 7,8 70 40x.5, 33 7,8 500

YVZ3V-R (NYFGby) Application: Underground, indoor and outdoor installation, where better mechanical protection or higher is required resistance to higher tensile stress is required. Technical data: There is an armour of galvanized flat steel wires between inner covering and outer sheath against mechanical stresses. Max. conductor temperature: 70 C Rated voltage: 0.6/kV Rated Number of Outer Sheath Outer Resistance Crosssection Strands at 0 C Rated Current Ground Air 3x5+6 7 6,4, 8 7 30 05 00 3x35+6 7-9 7,7, 3 4 55 30 700 3x50+5 9 9,,4, 35 0,387 85 60 36 3x70+35 9,4, 4 0,68 30 00 4550 3x95+50 9,7,6,6 47,5 3 75 45 6000 3x0+70 37 4,4,6 3 35 85 7000 37 6,,6,6 5 3x50+70 55 0,4 355 35 8500 3x85+95 37 8,0 3 6 0,099 400 370 0050 3x40+0 6, 3,4 69 0,0754 465 435 850 4x0 3,6,0,5 3 77 60 0 4x6 7 5,,0 6,5 00 700 4x5 7 6,4, 30 7 30 05 075 4x35 7-9 7,7, 33 4 55 30 400 4x50 9 9,,4, 38 0,387 85 60 330

H05RR-f (NMH) Note: Wires are tinned or untinned and diameters are 0.0 Application: In dry, damp and wet spaces, outdoors, on agricultural premises, for medium-stress portable tools such as grinders, drills, electrical ovens, lamps, where cables are exposed to severe stress due to bending and twisting. Technical data: Fine stranded copper, rubber sheath. Max. conductor temperature: 60 C Rated Number of Outer Sheath Outer Resistance Crosssection Strands at 0 C x0.75 4, 7,5 6,7 8 x 3,4 7,7 0,0 9 x.5,7 8,4 3,7 4 x.5,3, 8, 73 x4 7,7,,3 5,09 55 3x0.75 4, 8 6,7 99 3x 3,4 8,4 0,0 5 3x.5,7 9 3,7 36 3x.5,3, 8, 0 3x4 7,7, 3 5,09 300 4x0.75 4, 8,6 6,7 7 4x 3,4 9, 0,0 40 4x.5,7, 0 3,7 7 4x.5,3,,5 8, 66 4x4 7,7, 4,5 5,09 3 4x6 90 3,3,6 6,5 3,39 5 4x0 38 4,0,6 9,95 755

H07RN-f (NSH-öu) Note: There is a textile braiding between inner covering and outer sheath. Application: In dry and damp locations, outdoors, mobile generators and motors, trains, agricultural tools etc, where mechanical stresses are high. Technical data: Tinned or untinned fine stranded copper, rubber insulation and sheath with single or multi-core cables. Max. conductor temperature: 60 C Rated Number of Crosssection Strands Inner Sheath Outer Sheath Outer Resistance at 0 C x6 50 5,5,4 -,6 4,4 30 x5 0 6,5,6-6 0.795 458 x35 0 8,6-7,5 0.565 58 x50 600 9-9 0.393 760 x70 40,0 -, 0.77 037 x95 3040 3,5,0-0.0 36 3840 6,4 -,,5 5 x0 9 0.64 760 x50 40 8,4 -,5 3 0.3 5 x.5,7,0,6 4 3,7 3 x.5,3,0,6 6 8, 30 x4 7,7,0, 9 5,09 46 x6 90 3,3,0, 0 3,39 534 x0 38 4,,,,95 698 3x.5,7,0,6 4,5 3,7 63 3x.5,3,0,6 6,5 8, 35 3x4 7,7,0, 9,5 5,09 54 3x6 90 3,3,0, 3,39 60 3x0 38 4,,,5,95 3x6 50 5,,4, 5,4 078 3x6+0 50/38 5/4./.,4, 5,5.4/.95 357 3x5+6 0/50 6.5/5.4/.,6,5 3,5 0.795 9 3x35+6 0/50 8/5.4/.,6,5 35 0.565 350 3x50+5 600/0 9/6.5.6/.4 4 0.393 39 3x70+35 40/0 /8.6/.4,0 3 3,5 47 0.77 440 3x95+50 3040/600 3.5/9.8/.6,4 4 56 0.0 645 3x0+70 3840/40 6/.8/.6,4 4 6,5 0.64 77 3x50+70 40/40 8/ /.6,8 4,5 69,5 0.3 9385 4x.5,7,0,6 5,5 3,7 305 4x.5,3,0,6 7,5 8, 40 4x4 7,7,0, 5,09 649 4x6 90 3,3,0,,5 3,39 747 4x0 38 4,,, 5,95 070 4x6 50 5,,4, 8,4 40

H07RN-f (NSH-öu) cont. Note: Wires are 0.0mm tinned or untinned, fine stranded. Insulated conductors twisted together with fillers. Rated Number of Outer Resistance Crosssection Strands at 0 C Inner Sheath Outer Sheath 0x.5,7, 3 3,70 57 0x.5,3,4, 7 8, 860 x.5,7, 4 3,70 633 x.5,3,4, 8,5 8, 990 4x.5,7,4, 6 3,70 75 4x.5,3,4 30 8, 05 6x.5,7,4,, 6 3,70 795 6x.5,3,4,5 30 8, 87 9x.5,7,4, 7,5 3,70 894 9x.5 x.5,3,6,5 3,5 8, 39,7,4, 9 3,70 97 x.5,3,6,5 34 8, 547 4x.5,7,6,5 30 3,70 04 4x.5,3 3 37 8, 0 5x.5,7,4,6 6,5 3,70 303 5x.5,3, 0 8, 498 6x.5,7, 9,5 3,70 44 6x.5,3,,5 8, 567 7x.5,7, 0 3,70 445 7x.5,3,,5 8, 69 8x.5,7,,5 3,70 5 8x.5,3,4, 4,5 8, 74

H0N-d (NSLFF-öu) Welding Cables Application: In dry,damp and wet locations, also outdoors for welding machines. Technical data: 0.0mm stranded copper is wrapped with a seperator, which is covered with an oil and flame resistant rubber sheath. Max. conductor temperature: C Rated voltage: 500V Rated Number of Crosssection Strands PE Seperator Outer Sheath Outer Resistance at 0 C 6 50 5,5 9,5,6 5 0 6,5 0.758 3 35 0 8,5 0.536 50 600 9 3,5 0.379 573 70 40, 6 0.68 793 95 3040 3,5, 8,5 0.98 047

H03RT-f (NSA) Application: For applications such as light portable heating appliances, portable lamps or electric irons, where mechanical stresses are low. Technical data: Finely stranded copper, insulated with rubber, twisted with textile fillers and covered with textile braiding. Max. conductor temperature: 60 C Rated voltage: 300V/300V Rated Number of Core Braided Outer Resistance Crosssection Strands at 0 C 3x0.75 4,,9 7, 6,70 5 3x 3,4 3, 7,5 0,00 55 4x 3,4 3, 8,6 0,00 73

H05VV5-f (TTR) Control Cables Note: Insulated wires are twisted together with fillers. Number-coded. Rated Number of Outer sheath Outer Resistance Crosssection Strands at 0 C 5x0.75 4, 9 6 6 6x0.75 4, 0 6 37 7x0.75 4, 6 60 8x0.75 4, 6 88 0x0.75 4,, 3,5 6 0 x0.75 4,, 5 6 79 4x0.75 4,, 5,5 6 30 9x0.75 4,,4 7 6 393 0x0.75 4,,4 7 6 400 4x0.75 4,,4 9 6 468 30x0.75 4, 6 579 36x0.75 4, 6 706 5x 3,4 9,5 9,5 37 6x 3,4 9,5 63 7x 3,4,5 9,5 96 0x 3,4,4 4,5 9,5 77 x 3,4,4 5 9,5 30 4x 3,4,4 6,5 9,5 369 9x 3,4 8 9,5 476 0x 3,4 8 9,5 49 4x 3,4 9,5 9,5 597 30x 3,4 9,5 735

H05VV5-f (TTR) Control Cables cont. Note: Insulated wires are twisted together with fillers. Number-coded. Rated Number of Outer sheath Outer Resistance Crosssection Strands at 0 C 5x.5,7, 0,4 3,3 75 6x.5,7,,5 3,3 07 7x.5,7, 3,3 34 0x.5,7,4 5,5 3,3 330 x.5,7,4 6 3,3 389 4x.5,7,4 6,5 3,3 438 6x.5,7,6 7,5 3,3 507 9x.5,7,6 8,5 3,3 5 x.5,7,6 9,5 3,3 637 4x.5,7,5 3,3 758 30x.5,7 5 3,3 90 5x.5,3, 3 7,98 67 7x.5,3, 5 7,98 355 0x.5,3,4 8,5 7,98 500 x.5,3,4 9,8 7,98 583 4x.5,3,6 7,98 696 6x.5,3,6,5 7,98 777 9x.5,3 3,5 7,98 905 x.5,3 4,5 7,98 987 4x.5,3 7,5 7,98 55 30x.5,3 9 7,98 385 36x.5,3 3 7,98 69 40x.5,3 3,5 7,98 775

Water pump motor cables Application: In connections for water pumps in wells with pure/salty water. Flexible. Medium mechanical stress. Technical data: is insulated with PVC/A. Twisted insulated cores are covered with special rubber inner covering and PVC outer sheath. Max. conductor temperature: 70 C Rated voltage: 0.6/kV Note: Other crosssections can be produced on request. Rated Number of Outer sheath Outer Resistance Crosssection Strands at 0 C 4x.5,7,6 3,3 0 4x.5,3 3,6 7,98 5 4x4 7,7 6,5 4.95 447 4x6 90 3,3 8 3.3 565 4x0 38 4, 0.9 785 3x6+0 50/38 5/4./. 3,5. 0 3x5+6 0/50 6.5/5.3/. 7 0.7 550 3x35+6 0/50 8,5.3/. 9 0.554 900

YSLY-j Application: In dry and damp interiors, esp. industrial environmental conditions, but not outdoors. Technical data: Resistant to oil and chemicals. Flexible. Finely stranded bare copper wire. PVC insulations are black and marked with white numbers & yellow/green. Outer sheath is grey and oil and flame resistant. Max. conductor temperature: 70 C Rated voltage: 300/500V Rated Outer Rated Outer Crosssection Crosssection x0.5 4,8 35 5G0.75 3,8 337 3x0.5 5, 4 6G0.75 4, 350 4x0.5 5,7 54 34G0.75 5,9 4 5x0.5 6, 63 4G0.75 7,4 538 7x0.5 6,7 8 50G0.75 9, 6 G0.5 8,9 3 6G0.75 779 4G0.5 9,5 53 65G0.75 83 8G0.5 88 G0.75 3,6 09 G0.5,7 00G0.75 6,4 7 5G0.5,4 6 X 5,7 53 30G0.5 3,3 304 3G 6 65 35G0.5 4,5 356 3X 6 65 40G0.5 5,4 400 4G 6,5 79 5G0.5 7,3 57 4X 6,5 79 6G0.5 8,5 603 5G 7, 94 65G0.5 9,6 644 5X 7, 94 G0.5, 7 6G 8 3 00G0.5 3,6 975 7G 8 6 X0.75 5,4 45 7X 8 6 3G0.75 5,7 55 8G 9,5 49 3X0.75 5,7 55 9G 0 64 4G0.75 6, 66 0G 0, 4X0.75 6, 66 G 05 5G0.75 6,7 79 X 05 5X0.75 6,7 79 4G, 38 7G0.75 7,3 0 6G 66 7X0.75 7,3 0 8G,7 300 9G0.75 9,4 37 8X,7 300 0G0.75 9,6 50 0G 3,4 330 G0.75 9,9 7 0X 3,4 330 X0.75 9,9 7 5G 4,7 408 5G0.75 09 6G 5, 44 6G0.75, 0 34G 7, 55 8G0.75,7 44 36G 7,4 578 G0.75 3 86

YSLY-j cont. Rated Outer Rated Outer Crosssection Crosssection 40G 8,4 638 65G.5 6,7 398 4G 8,8 66 G.5 8,8 708 50G 797 X.5 7,5 0 56G,4 888 3G.5 8, 3 6G, 958 4G.5 8,9 63 65G 3,6 033 5G.5 0 00 G 5,3 5 7G.5, 67 00G 8,3 560 G.5 4,8 445 X.5 6,3 68 4G.5 5,8 55 3G.5 6,7 84 8G.5 7,8 6 3X.5 6,7 84 5G.5 890 4G.5 7, 04 34G.5 4,4 08 4X.5 7, 04 50G.5 9,4 754 5G.5 8, 8 3G4 9,9 0 5X.5 8, 8 4G4 49 7G.5 8,9 66 5G4, 305 7X.5 8,9 66 7G4 3,4 407 8G.5 97 G4 7,6 634 9G.5,4 3G6,7 89 0G.5,6 43 4G6 3 365 G.5,6 58 5G6 4,5 447 G.5 79 7G6 6 600 X.5 79 3G0 4,6 466 4G.5,7 33 4G0 6, 590 6G.5 3,4 36 5G0 8, 7 8G.5 4,4 407 7G0 0 968 G.5 5,7 469 4G6 8,8 087 5G.5 6,9 560 5G6, 370 6G.5 7,3 58 7G6 3,4 779 3G.5 7,5 704 4G5 3,5 58 34G.5 9,4 746 5G5 6,4 998 4G.5,3 895 4G35 6,8 06 50G.5 3,5 089 5G35 30, 635 6G.5 5, 309

NYRY Application: Underground, indoor and outdoor installation, where resistance to high tensile or mechanical stress is required. Technical data: There is an armour of galvanized wires between inner covering and outer sheath against mechanical stress. Max. conductor temperature: 70 C Rated voltage: 0.6/kV Rated Outer sheath Outer Crosssection x.5,38,5 300 x.5,78 3,5 343 x4,6 5,5 468 x6,76 7,5 67 x0 3,55 9 866 3x.5,38 3 37 3x.5,78 4 398 3x4,6 6,5 640 3x6,76 7,5 734 3x0 3,55 9,5 975 4x.5,38 3,5 38 4x.5,78 5 469 4x4,6 8 736 4x6,76 9 878 4x0 3,55,5 50

Some of our special cables

Cable harnesses We are able to produce a wide range of cable harnesses.

Power cords Power cords 3G0.75 mm 3G.00 mm 3G.50 mm

Group sockets Group sockets We have a wide range of group sockets available.

Cable carriers Cross sections & Lengths: 3x0.75mm 0mt. 3x0.75mm 30mt. 3xmm 0mt. 3xmm 30mt. 3x.5mm 0mt. 3x.5mm 30mt. 3x.5mm 50mt. 3x.5mm 0mt. 3x.5mm 30mt. 3x.5mm 50mt. Beside these cross sections and lengths, we are also ready to meet any of your special requirements.

A few pictures from our factories in Istanbul and Manisa:

Istanbul Factory: Ferhatpasa Cad. Sehit Naci Cakar Sok. No: Bayrampasa Istanbul - TURKEY Manisa Factory: Organize Sanayi Bolgesi Cumhuriyet Bulvari No:6 Manisa - TURKEY Phone: +90--63 53 3, +90--567 07 67, +90--576 87 98 Fax: +90--565 30 75 http://www.elkicable.com elki@elkicable.com