STRUCTURAL CALCULATIONS FOR SUSPENDED BUS SYSTEM SEISMIC SUPPORTS SEISMIC SUPPORT GUIDELINES

Σχετικά έγγραφα
moment ENGINEERING + DESIGN Warwick Ave, Suite C5 Fairfax, VA Phone: Web: February 20, 2015

5.0 DESIGN CALCULATIONS

CONSULTING Engineering Calculation Sheet

D28 1-1/4" PIPE x 42-1/2" HIGH RAIL WITHOUT BOTTOM RAIL

Technical Data for Profiles. α ( C) = 250 N/mm 2 (36,000 lb./in. 2 ) = 200 N/mm 2 (29,000 lb./in 2 ) A 5 = 10% A 10 = 8%

APPENDIX 1: Gravity Load Calculations. SELF WEIGHT: Slab: 150psf * 8 thick slab / 12 per foot = 100psf ROOF LIVE LOAD:

COMPOSITE INSULATOR. ANSI Standard Type COMPOSITE LONGE ROD SUSPENSION INSULATOR. PDI 16mm Diameter Rod Deadend Insulators

Chapter 7 Transformations of Stress and Strain

Strain gauge and rosettes

Ingenieurbüro Frank Blasek - Beratender Ingenieur Am Kohlhof 10, Osterholz-Scharmbeck Tel: 04791/ Fax: 04791/

Ingenieurbüro Frank Blasek - Beratender Ingenieur Am Kohlhof 10, Osterholz-Scharmbeck Tel: 04791/ Fax: 04791/

Περίπτωση Μελέτης Θαλάσσιας Κατασκευής με χρήση λογισμικού και με βάση Κώδικες (Compliant Tower) (8.1.10)

ΔΗΛΩΣΗ ΕΠΙΔΟΣΕΩΝ Αρ. HSL-3_B-1109-CPR-0002

DERIVATION OF MILES EQUATION FOR AN APPLIED FORCE Revision C

Second Order RLC Filters

Surface Mount Multilayer Chip Capacitors for Commodity Solutions

TEST REPORT Nο. R Έκθεση Ελέγχου α/α

Delhi Noida Bhopal Hyderabad Jaipur Lucknow Indore Pune Bhubaneswar Kolkata Patna Web: Ph:

Review Test 3. MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

HSS Hollow. Structural Sections LRFD COLUMN LOAD TABLES HSS: TECHNICAL BROCHURE

Srednicki Chapter 55

MasterSeries MasterPort Lite Sample Output

20/01/ of 8 TOW SSD v3. C 2.78AC Σ Cumul. A*C. Tc 1 =A14+1 =B14+1 =C14+1 =D14+1 =E14+1 =F14+1 =G14+1 =H14+1 =I14+1 =J14+1 =K14+1

Homework 8 Model Solution Section

Calculating the propagation delay of coaxial cable

5.4 The Poisson Distribution.

Thin Film Chip Resistors

LUMINAIRE PHOTOMETRIC TEST REPORT

Deck Fasteners for Attachment to Bar Joist 3.5.2

Gearmotor Data. SERIES GM9000: We have the GM9434H187-R1

DuPont Suva 95 Refrigerant

w o = R 1 p. (1) R = p =. = 1

6.4 Superposition of Linear Plane Progressive Waves

Weight [lb] = (Do-t)*π*L*t*40.84/ (60-1)*3.1416*100*1*40.84/144 = (20000*1*1)/(29+0.6*1) = Pipe and Shell ver 4.

1. Αφετηρία από στάση χωρίς κριτή (self start όπου πινακίδα εκκίνησης) 5 λεπτά µετά την αφετηρία σας από το TC1B KALO LIVADI OUT

Section 9.2 Polar Equations and Graphs

DESIGN OF MACHINERY SOLUTION MANUAL h in h 4 0.

Assalamu `alaikum wr. wb.

1 String with massive end-points

EE512: Error Control Coding

Consolidated Drained

10 MERCHIA. 10. Starting from standing position (where the SIGN START ) without marshal (self start) 5 minutes after TC4 KALO LIVADI OUT

Epoxy resin - High performance. Anchor mechanical properties

Solution to Review Problems for Midterm III

Trigonometric Formula Sheet

is like multiplying by the conversion factor of. Dividing by 2π gives you the

0.635mm Pitch Board to Board Docking Connector. Lead-Free Compliance

Aluminum Electrolytic Capacitors (Large Can Type)

Design of Self supporting Steel Chimney for

A, B. Before installation of the foam parts (A,B,C,D) into the chambers we put silicone around. We insert the foam parts in depth shown on diagram.

4.4 Superposition of Linear Plane Progressive Waves

Απόκριση σε Μοναδιαία Ωστική Δύναμη (Unit Impulse) Απόκριση σε Δυνάμεις Αυθαίρετα Μεταβαλλόμενες με το Χρόνο. Απόστολος Σ.

Areas and Lengths in Polar Coordinates

( ) Sine wave travelling to the right side

Problem Set 9 Solutions. θ + 1. θ 2 + cotθ ( ) sinθ e iφ is an eigenfunction of the ˆ L 2 operator. / θ 2. φ 2. sin 2 θ φ 2. ( ) = e iφ. = e iφ cosθ.

TRIAXIAL TEST, CORPS OF ENGINEERS FORMAT

ΕΛΕΓΧΟΣ ΤΩΝ ΠΑΡΑΜΟΡΦΩΣΕΩΝ ΧΑΛΥΒ ΙΝΩΝ ΦΟΡΕΩΝ ΜΕΓΑΛΟΥ ΑΝΟΙΓΜΑΤΟΣ ΤΥΠΟΥ MBSN ΜΕ ΤΗ ΧΡΗΣΗ ΚΑΛΩ ΙΩΝ: ΠΡΟΤΑΣΗ ΕΦΑΡΜΟΓΗΣ ΣΕ ΑΝΟΙΚΤΟ ΣΤΕΓΑΣΤΡΟ

Written Examination. Antennas and Propagation (AA ) April 26, 2017.

Math221: HW# 1 solutions

DuPont Suva. DuPont. Thermodynamic Properties of. Refrigerant (R-410A) Technical Information. refrigerants T-410A ENG

Aluminum Electrolytic Capacitors

2 Composition. Invertible Mappings

Technical Information T-9100 SI. Suva. refrigerants. Thermodynamic Properties of. Suva Refrigerant [R-410A (50/50)]

CHAPTER 25 SOLVING EQUATIONS BY ITERATIVE METHODS

3.4 SUM AND DIFFERENCE FORMULAS. NOTE: cos(α+β) cos α + cos β cos(α-β) cos α -cos β

CONTENTS. PROFILE OPTIONS Page: 2. ADDITIONAL PROFILES Page: 3. DESIGN: 1050 Page: 4. DESIGN: 1054 Pages: DESIGN: 1052 Pages: 5-12

Second Order Partial Differential Equations

Rod End > Spherical Bearings Product Overview

Boundary-Layer Flow over a Flat Plate Approximate Method

Matrices and Determinants

Stresses in a Plane. Mohr s Circle. Cross Section thru Body. MET 210W Mohr s Circle 1. Some parts experience normal stresses in

Multilayer Ceramic Chip Capacitors

Data sheet Thick Film Chip Resistor 5% - RS Series 0201/0402/0603/0805/1206

CHAPTER 12: PERIMETER, AREA, CIRCUMFERENCE, AND 12.1 INTRODUCTION TO GEOMETRIC 12.2 PERIMETER: SQUARES, RECTANGLES,

CHAPTER 48 APPLICATIONS OF MATRICES AND DETERMINANTS

Areas and Lengths in Polar Coordinates

Metal Oxide Varistors (MOV) Data Sheet

CSR series. Thick Film Chip Resistor Current Sensing Type FEATURE PART NUMBERING SYSTEM ELECTRICAL CHARACTERISTICS


D Alembert s Solution to the Wave Equation

ANSWERSHEET (TOPIC = DIFFERENTIAL CALCULUS) COLLECTION #2. h 0 h h 0 h h 0 ( ) g k = g 0 + g 1 + g g 2009 =?

DuPont Suva 95 Refrigerant

RDN-250i Application / Benefits Model No. Servo Motor Maker SPECIFICATIONS Table Dia. Horizontal [kg] Center Height Resister Dia.

Multilayer Ceramic Chip Capacitors

ΑΝΩΤΑΤΗ ΣΧΟΛΗ ΠΑΙ ΑΓΩΓΙΚΗΣ ΚΑΙ ΤΕΧΝΟΛΟΓΙΚΗΣ ΕΚΠΑΙ ΕΥΣΗΣ ΠΑΡΑΔΟΤΕΟ ΕΠΙΣΤΗΜΟΝΙΚΗ ΕΡΓΑΣΙΑ ΣΕ ΔΙΕΘΝΕΣ ΕΠΙΣΤΗΜΟΝΙΚΟ ΠΕΡΙΟΔΙΚΟ

Project: Brimsmore, Ye... Job no: C08127 Designed By kristian Checked By Network W Network Design Table for OUTFALL B.SWS

Α ιθ EL. 3. Κα ασ ασ ής: fischerwerke GmbH & Co. KG, Klaus-Fischer-Straße 1, Waldachtal, α ία. Tumlingen,

Section 8.3 Trigonometric Equations

Macromechanics of a Laminate. Textbook: Mechanics of Composite Materials Author: Autar Kaw

LUMINAIRE PHOTOMETRIC TEST REPORT

Mock Exam 7. 1 Hong Kong Educational Publishing Company. Section A 1. Reference: HKDSE Math M Q2 (a) (1 + kx) n 1M + 1A = (1) =

Surface Mount Aluminum Electrolytic Capacitors

Pg The perimeter is P = 3x The area of a triangle is. where b is the base, h is the height. In our case b = x, then the area is

HIS series. Signal Inductor Multilayer Ceramic Type FEATURE PART NUMBERING SYSTEM DIMENSIONS HIS R12 (1) (2) (3) (4)

Anti-Corrosive Thin Film Precision Chip Resistor (PR Series)

ΕΘΝΙΚΟ ΜΕΤΣΟΒΙΟ ΠΟΛΥΤΕΧΝΕΙΟ ΣΧΟΛΗ ΠΟΛΙΤΙΚΩΝ ΜΗΧΑΝΙΚΩΝ ΤΟΜΕΑΣ ΟΜΟΣΤΑΤΙΚΗΣ ΕΡΓΑΣΤΗΡΙΟ ΜΕΤΑΛΛΙΚΩΝ ΚΑΤΑΣΚΕΥΩΝ

Figure 1 - Plan of the Location of the Piles and in Situ Tests

Concrete Mathematics Exercises from 30 September 2016

Analyse af skrå bjælke som UPE200

COMPOSITE SLABS DESIGN CONTENTS

Transcript:

Customer: PDI, 4200 Oakleys Court, Richmond, VA 23223 Date: 5/31/2017 A. PALMA e n g i n e e r i n g Tag: Seismic Restraint Suspended Bus System Supports Building Code: 2012 IBC/2013 CBC&ASCE7-10 STRUCTURAL CALCULATIONS FOR SUSPENDED BUS SYSTEM SEISMIC SUPPORTS SEISMIC SUPPORT GUIDELINES PROJECT: REVISION 0 Original Calculations Dated 05/30/17 CALCULATIONS PREPARED BY: A. PALMA ENGINEERING P.O. Box 1075, Pleasanton, CA 94566 Tel (925) 469-0417, Fax (925) 469-0462 For Office Use Only: Busrail busway bus system Unistrut - 2013cbc.xmcd C:\Users\TUNG\A Palma Engineering\PDI\150522 Busway Seismic Bracing\ Page 1

Customer: PDI, 4200 Oakleys Court, Richmond, VA 23223 Date: 5/31/2017 A. PALMA e n g i n e e r i n g Tag: Seismic Restraint Suspended Bus System Supports Building Code: 2012 IBC/2013 CBC&ASCE7-10 STRUCTURAL CALCULATIONS For Office Use Only: Busrail busway bus system Unistrut - 2013cbc.xmcd C:\Users\TUNG\A Palma Engineering\PDI\150522 Busway Seismic Bracing\ Page 2

Customer: PDI, 4200 Oakleys Court, Richmond, VA 23223 Date: 5/31/2017 A. PALMA e n g i n e e r i n g Tag: Seismic Restraint Suspended Bus System Supports Building Code: 2012 IBC/2013 CBC&ASCE7-10 DESIGN CRITERIA: Govening Code: 2012 International Building Code/2013 California Building Code (CBC) & ASCE7-10 DESCRIPTION: Substantiate suspended electrical bus system seismic load and dead weight. Members will be chosen to design at worst case load combination according to ASCE7 Chapter 2. LOADING CRITERIA: VERTICAL LOAD: L s := 5 ft Maximum tributary length of support for dead load W 250 := 7 lb ft Max. weight for 250Amp bus system W 400 := 10 lb ft Max. weight for 400Amp bus system W 800 := 20 lb ft Max. weight for 800Amp bus system SEISMIC LOAD: Seismic demand per each different project can be determined through this equation: where, z := 1 0.4 a p S DS F p := 1 2 z R + and can be simplify to this, F p h p := 0.50 S DS I p Height in structure of point of attachment of component w/ respect to the base h := 1 Average roof height of structure w/ respect to base I p := 1.0 Component importance factor a p := 2.5 Component amplification factor (ASCE7, table 13.6-1) R p := 6.0 Component response modification factor (ASCE7, table 13.6-1) S DS Spectral acceleration, short period. (Per project's structure sheet or USGS Seismic Design Maps) Let's assume seismic demand cateogorize into these three zone: F p1 := 0.50 Seismic demand at 0.50G F p2 := 0.75 Seismic demand at 0.75G F p3 := 1.00 Seismic demand at 1.00G For Office Use Only: Busrail busway bus system Unistrut - 2013cbc.xmcd C:\Users\TUNG\A Palma Engineering\PDI\150522 Busway Seismic Bracing\ Page 3

Customer: PDI, 4200 Oakleys Court, Richmond, VA 23223 Date: 5/31/2017 A. PALMA e n g i n e e r i n g Tag: Seismic Restraint Suspended Bus System Supports Building Code: 2012 IBC/2013 CBC&ASCE7-10 SEISMIC DESIGN AT 0.50G: converting Horizontal Seismic Force, F ph, in allowable yields F ph := 0.7 F p1 = 0.35 ASCE7 Sect. 13.1.7, for ASD additional Vertical Seismic Force, F pv, yields: F pv := 0.20 CHECK SEISMIC BRACE MEMBER: REACTIONS: θ := 45 deg Allowable brace ratio angle (1:1 = 45.0, 1.5:1 = 56.3, 2:1 = 63.4 ) N brt := 1 Number of brace(s) in transverse direction N brl := 1 Number of brace(s) in longitudinal direction For 250Amp & 400Amp bus system: L t1 := 40 ft Maximum tributary length of support for transverse seismic L l1 := 80 ft Maximum tributary length of support for longitudinal seismic For 800Amp bus system: L t2 := 20 ft Maximum tributary length of support for transverse seismic L l2 := 40 ft Maximum tributary length of support for longitudinal seismic Maximum brace compression in transverse direction ( ) L t1 ( ) L t2 F ph W 400 F ph W 800 F brt1 := = 198lb F N brt cos( θ) brt2 := N brt cos( θ) Maximum brace compression in longitudinal direction ( ) L l1 ( ) L l2 F ph W 400 F ph W 800 F brl1 := = 396lb F N brl cos( θ) brl2 := N brl cos( θ) = 198lb = 396lb COMPRESSION CHECK FOR SINGLE STRUT: Unistrut P1000 Member designation L u2 := 120 in Unbraced length of member P allow := 1380 lb Max. allowable load at slot face F brl2 = 396lb P allow = 1380lb Okay! CHECK STRUT NUT CONNECTION: 3/8" Dia. Strut Nut Member designation V allow := 800 lb Allowable resistance to slip N snut := 1 Number of strut nut(s) F brt2 = 198lb V allow N snut = 800 lb Okay! For Office Use Only: Busrail busway bus system Unistrut - 2013cbc.xmcd C:\Users\TUNG\A Palma Engineering\PDI\150522 Busway Seismic Bracing\ Page 4

Customer: PDI, 4200 Oakleys Court, Richmond, VA 23223 Date: 5/31/2017 A. PALMA e n g i n e e r i n g Tag: Seismic Restraint Suspended Bus System Supports Building Code: 2012 IBC/2013 CBC&ASCE7-10 CHECK HANGER ROD MEMBER: MEMBER PHYSICAL PROPERTIES: d := 0.375 in Min. all-threaded rod member size N hr := 1 Number of hanger supporting busduct CHECK FOR TENSION: T hrallow := 730 lb Allowable load per MSS SP-58 W 800 L s + W 800 L s F pv T rod := + F N brl2 sin( θ) = 400 lb T hrallow = 730lb Okay! hr CHECK FOR COMPRESSION FROM UPLIFT: P rod := W 800 L s + W 800 L s F pv F N brl2 sin( θ) = 160lb hr Using AISC requirements for maximum allowable length and maximum allowable stress: K L hr d 200 where, K := 1.0 d = 0.375 in r r hr := hr 4 200 r hr therefore, L hr := = 18.75 in (Maximum length allowed for K hanger rod subjected to compression without stiffener) Let stiffen hanger rod with 1-5/8"x12GA single channel with rod's clamp at L u3 := 13 in Thus, F e := K L u3 = 139 where, F r y := 36000 lb E := 29000000 lb A := 0.555 in 2 hr in 2 in 2 π 2 E K L u3 r hr 2 = 14885 lb in 2 K L u3 E = 139 > 4.71 = 134 (AISC Sect. 16.1, Chapt. E-3) r hr F y F cr := P n := 0.877 F e F cr A = 13054 lb in 2 = 7245lb CHECK FOR FAILURE: Ω := 1.67 Safety factor P rod = 160lb P n Ω = 4338lb Okay! For Office Use Only: Busrail busway bus system Unistrut - 2013cbc.xmcd C:\Users\TUNG\A Palma Engineering\PDI\150522 Busway Seismic Bracing\ Page 5

Customer: PDI, 4200 Oakleys Court, Richmond, VA 23223 Date: 5/31/2017 A. PALMA e n g i n e e r i n g Tag: Seismic Restraint Suspended Bus System Supports Building Code: 2012 IBC/2013 CBC&ASCE7-10 CHECK SEISMIC ANCHOR ATTACHMENT TO CONCRETE STRUCTURE: Per ASCE 13.4.2, Anchor's design force must carry 2.5 times the force in the component. conc := 2.5 Anchor design factor to concrete lrfd := 0.7 ASD to LRFD ANCHOR REACTION(S) AT SEISMIC BRACE TO STRUCTURAL LOCATION: conc T a := ( F brl2 sin ( θ ) ) = 1000 lb Seismic brace anchor tension lrfd conc V a := ( F brl2 cos ( θ ) ) = 1000 lb Seismic brace anchor shear lrfd Consider Powers Stud SD2 expansion anchor at 1/2" dia. with 3-1/4" min. effective embedment. ANCHOR REACTION(S) AT SEISMIC HANGER TO STRUCTURAL LOCATION: P o := W 800 L s + W 800 L s N hr F pv T a2 := P o + T a = 1120lb Seismic hanger anchor tension Consider Powers Stud SD2 expansion anchor at 1/2" dia. with 3-1/4" min. effective embedment. ** Refer to attached Powers Design Assist for anchor specification and concrete break-out calculations. For Office Use Only: Busrail busway bus system Unistrut - 2013cbc.xmcd C:\Users\TUNG\A Palma Engineering\PDI\150522 Busway Seismic Bracing\ Page 6

Customer: PDI, 4200 Oakleys Court, Richmond, VA 23223 Date: 5/31/2017 A. PALMA e n g i n e e r i n g Tag: Seismic Restraint Suspended Bus System Supports Building Code: 2012 IBC/2013 CBC&ASCE7-10 SEISMIC DESIGN AT 0.75G: converting Horizontal Seismic Force, F ph, in allowable yields F ph := 0.7 F p2 = 0.53 ASCE7 Sect. 13.1.7, for ASD additional Vertical Seismic Force, F pv, yields: F pv := 0.20 CHECK SEISMIC BRACE MEMBER: REACTIONS: θ := 45 deg Allowable brace ratio angle (1:1 = 45.0, 1.5:1 = 56.3, 2:1 = 63.4 ) N brt := 1 Number of brace(s) in transverse direction N brl := 1 Number of brace(s) in longitudinal direction For 250Amp & 400Amp bus system: L t1 := 25 ft Maximum tributary length of support for transverse seismic L l1 := 50 ft Maximum tributary length of support for longitudinal seismic For 800Amp bus system: L t2 := 15 ft Maximum tributary length of support for transverse seismic L l2 := 30 ft Maximum tributary length of support for longitudinal seismic Maximum brace compression in transverse direction ( ) L t1 ( ) L t2 F ph W 400 F ph W 800 F brt1 := = 186lb F N brt cos( θ) brt2 := N brt cos( θ) Maximum brace compression in longitudinal direction ( ) L l1 ( ) L l2 F ph W 400 F ph W 800 F brl1 := = 371lb F N brl cos( θ) brl2 := N brl cos( θ) = 223lb = 445lb COMPRESSION CHECK FOR SINGLE STRUT: Unistrut P1000 Member designation L u2 := 120 in Unbraced length of member P allow := 1380 lb Max. allowable load at slot face F brl2 = 445lb P allow = 1380lb Okay! CHECK STRUT NUT CONNECTION: 3/8" Dia. Strut Nut Member designation V allow := 800 lb Allowable resistance to slip N snut := 1 Number of strut nut(s) F brt2 = 223lb V allow N snut = 800 lb Okay! For Office Use Only: Busrail busway bus system Unistrut - 2013cbc.xmcd C:\Users\TUNG\A Palma Engineering\PDI\150522 Busway Seismic Bracing\ Page 7

Customer: PDI, 4200 Oakleys Court, Richmond, VA 23223 Date: 5/31/2017 A. PALMA e n g i n e e r i n g Tag: Seismic Restraint Suspended Bus System Supports Building Code: 2012 IBC/2013 CBC&ASCE7-10 CHECK HANGER ROD MEMBER: MEMBER PHYSICAL PROPERTIES: d := 0.375 in Min. all-threaded rod member size N hr := 1 Number of hanger supporting busduct CHECK FOR TENSION: T hrallow := 730 lb Allowable load per MSS SP-58 W 800 L s + W 800 L s F pv T rod := + F N brl2 sin( θ) = 435 lb T hrallow = 730lb Okay! hr CHECK FOR COMPRESSION FROM UPLIFT: P rod := W 800 L s + W 800 L s F pv F N brl2 sin( θ) = 195lb hr Using AISC requirements for maximum allowable length and maximum allowable stress: K L hr d 200 where, K := 1.0 d = 0.375 in r r hr := hr 4 200 r hr therefore, L hr := = 18.75 in (Maximum length allowed for K hanger rod subjected to compression without stiffener) Let stiffen hanger rod with 1-5/8"x12GA single channel with rod's clamp at L u3 := 13 in Thus, F e := K L u3 = 139 where, F r y := 36000 lb E := 29000000 lb A := 0.555 in 2 hr in 2 in 2 π 2 E K L u3 r hr 2 = 14885 lb in 2 K L u3 E = 139 > 4.71 = 134 (AISC Sect. 16.1, Chapt. E-3) r hr F y F cr := P n := 0.877 F e F cr A = 13054 lb in 2 = 7245lb CHECK FOR FAILURE: Ω := 1.67 Safety factor P rod = 195lb P n Ω = 4338lb Okay! For Office Use Only: Busrail busway bus system Unistrut - 2013cbc.xmcd C:\Users\TUNG\A Palma Engineering\PDI\150522 Busway Seismic Bracing\ Page 8

Customer: PDI, 4200 Oakleys Court, Richmond, VA 23223 Date: 5/31/2017 A. PALMA e n g i n e e r i n g Tag: Seismic Restraint Suspended Bus System Supports Building Code: 2012 IBC/2013 CBC&ASCE7-10 CHECK SEISMIC ANCHOR ATTACHMENT TO CONCRETE STRUCTURE: Per ASCE 13.4.2, Anchor's design force must carry 2.5 times the force in the component. conc := 2.5 Anchor design factor to concrete lrfd := 0.7 ASD to LRFD ANCHOR REACTION(S) AT SEISMIC BRACE TO STRUCTURAL LOCATION: conc T a := ( F brl2 sin ( θ ) ) = 1125 lb Seismic brace anchor tension lrfd conc V a := ( F brl2 cos ( θ ) ) = 1125 lb Seismic brace anchor shear lrfd Consider Powers Stud SD2 expansion anchor at 5/8" dia. with 4-1/4" min. effective embedment. ANCHOR REACTION(S) AT SEISMIC HANGER TO STRUCTURAL LOCATION: P o := W 800 L s + W 800 L s N hr F pv T a2 := P o + T a = 1245lb Seismic hanger anchor tension Consider Powers Stud SD2 expansion anchor at 1/2" dia. with 3-1/4" min. effective embedment. ** Refer to attached Powers Design Assist for anchor specification and concrete break-out calculations. For Office Use Only: Busrail busway bus system Unistrut - 2013cbc.xmcd C:\Users\TUNG\A Palma Engineering\PDI\150522 Busway Seismic Bracing\ Page 9

Customer: PDI, 4200 Oakleys Court, Richmond, VA 23223 Date: 5/31/2017 A. PALMA e n g i n e e r i n g Tag: Seismic Restraint Suspended Bus System Supports Building Code: 2012 IBC/2013 CBC&ASCE7-10 SEISMIC DESIGN AT 1.00G: converting Horizontal Seismic Force, F ph, in allowable yields F ph := 0.7 F p3 = 0.70 ASCE7 Sect. 13.1.7, for ASD additional Vertical Seismic Force, F pv, yields: F pv := 0.20 CHECK SEISMIC BRACE MEMBER: REACTIONS: θ := 45 deg Allowable brace ratio angle (1:1 = 45.0, 1.5:1 = 56.3, 2:1 = 63.4 ) N brt := 1 Number of brace(s) in transverse direction N brl := 1 Number of brace(s) in longitudinal direction For 250Amp & 400Amp bus system: L t1 := 20 ft Maximum tributary length of support for transverse seismic L l1 := 40 ft Maximum tributary length of support for longitudinal seismic For 800Amp bus system: L t2 := 15 ft Maximum tributary length of support for transverse seismic L l2 := 30 ft Maximum tributary length of support for longitudinal seismic Maximum brace compression in transverse direction ( ) L t1 ( ) L t2 F ph W 400 F ph W 800 F brt1 := = 198lb F N brt cos( θ) brt2 := N brt cos( θ) Maximum brace compression in longitudinal direction ( ) L l1 ( ) L l2 F ph W 400 F ph W 800 F brl1 := = 396lb F N brl cos( θ) brl2 := N brl cos( θ) = 297lb = 594lb COMPRESSION CHECK FOR SINGLE STRUT: Unistrut P1000 Member designation L u2 := 120 in Unbraced length of member P allow := 1380 lb Max. allowable load at slot face F brl2 = 594lb P allow = 1380lb Okay! CHECK STRUT NUT CONNECTION: 3/8" Dia. Strut Nut Member designation V allow := 800 lb Allowable resistance to slip N snut := 1 Number of strut nut(s) F brt2 = 297lb V allow N snut = 800 lb Okay! For Office Use Only: Busrail busway bus system Unistrut - 2013cbc.xmcd C:\Users\TUNG\A Palma Engineering\PDI\150522 Busway Seismic Bracing\ Page 10

Customer: PDI, 4200 Oakleys Court, Richmond, VA 23223 Date: 5/31/2017 A. PALMA e n g i n e e r i n g Tag: Seismic Restraint Suspended Bus System Supports Building Code: 2012 IBC/2013 CBC&ASCE7-10 CHECK HANGER ROD MEMBER: MEMBER PHYSICAL PROPERTIES: d := 0.375 in Min. all-threaded rod member size N hr := 1 Number of hanger supporting busduct CHECK FOR TENSION: T hrallow := 730 lb Allowable load per MSS SP-58 W 800 L s + W 800 L s F pv T rod := + F N brl2 sin( θ) = 540 lb T hrallow = 730lb Okay! hr CHECK FOR COMPRESSION FROM UPLIFT: P rod := W 800 L s + W 800 L s F pv F N brl2 sin( θ) = 300lb hr Using AISC requirements for maximum allowable length and maximum allowable stress: K L hr d 200 where, K := 1.0 d = 0.375 in r r hr := hr 4 200 r hr therefore, L hr := = 18.75 in (Maximum length allowed for K hanger rod subjected to compression without stiffener) Let stiffen hanger rod with 1-5/8"x12GA single channel with rod's clamp at L u3 := 13 in Thus, F e := K L u3 = 139 where, F r y := 36000 lb E := 29000000 lb A := 0.555 in 2 hr in 2 in 2 π 2 E K L u3 r hr 2 = 14885 lb in 2 K L u3 E = 139 > 4.71 = 134 (AISC Sect. 16.1, Chapt. E-3) r hr F y F cr := P n := 0.877 F e F cr A = 13054 lb in 2 = 7245lb CHECK FOR FAILURE: Ω := 1.67 Safety factor P rod = 300lb P n Ω = 4338lb Okay! For Office Use Only: Busrail busway bus system Unistrut - 2013cbc.xmcd C:\Users\TUNG\A Palma Engineering\PDI\150522 Busway Seismic Bracing\ Page 11

Customer: PDI, 4200 Oakleys Court, Richmond, VA 23223 Date: 5/31/2017 A. PALMA e n g i n e e r i n g Tag: Seismic Restraint Suspended Bus System Supports Building Code: 2012 IBC/2013 CBC&ASCE7-10 CHECK SEISMIC ANCHOR ATTACHMENT TO CONCRETE STRUCTURE: Per ASCE 13.4.2, Anchor's design force must carry 2.5 times the force in the component. conc := 2.5 Anchor design factor to concrete lrfd := 0.7 ASD to LRFD ANCHOR REACTION(S) AT SEISMIC BRACE TO STRUCTURAL LOCATION: conc T a := ( F brl2 sin ( θ ) ) = 1500 lb Seismic brace anchor tension lrfd conc V a := ( F brl2 cos ( θ ) ) = 1500 lb Seismic brace anchor shear lrfd Consider Powers Stud SD2 expansion anchor at 5/8" dia. with 4-1/4" min. effective embedment. ANCHOR REACTION(S) AT SEISMIC HANGER TO STRUCTURAL LOCATION: P o := W 800 L s + W 800 L s N hr F pv T a2 := P o + T a = 1620lb Seismic hanger anchor tension Consider Powers Stud SD2 expansion anchor at 5/8" dia. with 4-1/4" min. effective embedment. ** Refer to attached Powers Design Assist for anchor specification and concrete break-out calculations. For Office Use Only: Busrail busway bus system Unistrut - 2013cbc.xmcd C:\Users\TUNG\A Palma Engineering\PDI\150522 Busway Seismic Bracing\ Page 12