Energy monitoring and event analysis - dimensions 96x96 mm Metering, monitoring & power quality Principle diagram DIRIS A40 DIRIS A40 DIRIS A40 Ethernet The solution for > Industry. > Infrastructure. > Data centres. Function is a panel mounted multifunction Easy to use and is easy to use. Detects wiring errors detect incorrect wiring and to automatically correct CT installation errors. are designed to measure and monitor electrical a high level of equipment performance, in terms of metrology, and the mechanical and Functions VERTELIS software solution PC PLC General measurement report Curves for current per phase Management softwares exploitation and the export of load curves electrical installation. remote device configuration; configuration communication and sent at a later time. a single file, which is especially useful for accordance with this standard. Strong points > Easy to use. > Detects wiring errors. > > Management softwares. > Conformity to standard Conformity to standards > > > > In addition to the functions of the shows the current and voltage shows the tangent the active, reactive and apparent P+/- ; Q+/-, S detects and stores the last - overvoltage - voltage dips - cut-offs - overcurrent. For each stored event, the DIRIS interval curves for the voltages V, V2, V3, U2, U23, U3 and the currents, Other functions: Multi-measurement Currents, In, Voltages & frequency U3, F, Vsystem, Usystem V3, U2, U23, U3, F Power P, 3Q, Q, 3S, S P, Q, S P, Q, S. Power factor - PF, PF Instantaneous total tangent Instantaneous, average and max. Temperatures - internal, Metering Harmonic analysis (level 63) Total harmonic distortion thd In thd V2, thd V3 thd U23, thd U3 Individual HV2, HV3, HU23, HU3 Events () Communications () RTU gateway Inputs / Outputs () Pulse metering Remote control/command Pulse report () Available as an option (see the following pages). 454 General Catalogue 203-204
Front panel 2 3 4 5 6 7 Plug-in modules Pulse outputs DIRIS A60* Communication MODBUS protocol (speed up to Ethernet communication. * With integrated memory module. Ethernet communication over TCP protocol.. Analogue outputs 3I, In, 3V, 3U, F, ± P, ± Q, S, Ppred, Q pred, Spred, T C internal, T C, T C 2, T C3 and 6 outputs. P, ± Q, S, THD 3V, THD 3U, Ppred, Qpred, Spred, T C internal, T C, T C2, T C3 and hour meter, - remote control, - timed remote control, 2 inputs for pulse metering. Temperature - Internal () See "Management softwares for DIRIS" p. 464. (2) See "External sensor PT 00" p. 505. General Catalogue 203-204 455
Current transformers (see page 488) Split-core current transformers Panel mounting kit for a 44 x 96 mm cut-out Terminals V V2 V3 VN A U X current inputs AUX: auxiliary power supplies U s voltage inputs Ethernet module 0V - + 0n R = 20 0 BASE T 00 BASE T RJ45 0 BASE T 00 BASE T RJ45 0 V - + gateway 0n R = 20Ω Pulse output module Temperature module Analogue output module 2 3 4 OUT OUT 2 pulse output n. 3-4 : pulse output n 2. 5 6 7 8 + - + - 0/4-20 ma 0/4-20 ma OUT OUT 2 9 20 2 27 28 29 30 22 23 24 25 26 sensor sensor 2 sensor 3 9 0 2 OUT A-Cd OUT 2 A-Cd 3 4 5 6 - + - + IN IN 2 9-0 : relay output n. relay output n 2. 3-4 : opto input n. opto input n 2. analogue output n. analogue output n 2. 456 General Catalogue 203-204
Electrical characteristics Current measurement on insulated inputs (TRMS) Via CT primary Via CT secondary Measurement range Input consumption s Permanent overload Intermittent overload n for s Voltage measurements (TRMS) VT primary VT secondary Frequency Input consumption s Permanent overload Current-voltage product Power measurement s Power factor measurement s Frequency measurement Measurement range s Energy accuracy Class 2 Auxiliary power supply Direct voltage DC tolerance Frequency Consumption 2 inputs / 2 outputs module: Outputs (alarms / control) 2 2 inputs / 2 outputs module: Phototransistor inputs (pulse metering) 2 Power supply Minimum signal width phototransistors Pulse output module 2 Analogue output module 2 insulated Range Maximum current MODBUS communication module Protocol speed Ethernet communication module Connection Speed Protocol Temperature inputs Connection Dynamic +/- digit Maximum length Operating conditions Operating temperature Storage temperature Relative humidity () Max. 3 modules / DIRIS. (2) Max. 2 modules / DIRIS. Case 96 60 92 + 0.8-0.0 35 92 + 0.8-0.0 Case degree of protection Front degree of protection Display type panel mounting fixed or plug-in Voltage and other terminals connection cross-section 2 Current connection cross-section 2 96 General Catalogue 203-204 457
Connection Low voltage balanced network for Recommendation: 3/4 wires with CT Single-phase Two-phase N N diris_392_d x_cat. Fuses 0.5 A gg / 0.5 A class CC. diris_393_d x_cat. Fuses 0.5 A gg / 0.5 A class CC.. Fuses 0.5 A gg / 0.5 A class CC. Low voltage unbalanced network for 3/4 wires with 3 CTs N diris_396_d x_cat. Fuses 0.5 A gg / 0.5 A class CC.. Fuses 0.5 A gg / 0.5 A class CC.. Fuses 0.5 A gg / 0.5 A class CC. Connection of voltage transformer for HV networks AC & DC auxiliary power supply 0 / 400 VAC (IEC) 20 / 350 VDC (IEC) LIYCY-CY 0V - + ON V V2 V3 N A U X. Fuses 0.5 A gg / 0.5 A class CC. 458 General Catalogue 203-204
References Basic device Auxiliary power supply U s Reference 4825 0207 Options Plug-in-modules () Reference Pulse outputs 4825 0090 communication 4825 0092 4825 0093 2 inputs / 2 outputs 4825 0094 4825 0203 4825 0204 Temperature inputs 4825 0206 () Easy integration of additional functions (maximum 3 slots per device). (2) Dimension of the plug-in module: 2 slots. Options Description of accessories To be ordered in multiples of Reference 4825 0089 4825 0088 560 008 6 560 007 602 0000 4899 00 Current transformer range See page 488 4825 0208 4825 0209 Management softwares for DIRIS See page 464 Services & Technical Assistance > Technical site audits and solution specification, commissioning, maintenance, support to ensure success with all your projects. General Catalogue 203-204 459