Datasheet * * Remotely Configurable Digital Pressure Transmitter. Application. Construction and mode of operation. Features.

Σχετικά έγγραφα
Industrial Pressure Transmitter

with serial RS485/RS232 output RS485

Siemens AG Rated current 1FK7 Compact synchronous motor Natural cooling. I rated 7.0 (15.4) 11.5 (25.4) (2.9) 3.3 (4.4)

PS500 Rotatable Programmable Pressure Sensors

Single-channel Safety Barriers Series 9001

Installation Instructions Electronic pressure sensor. PTD25-10-xxxxx PTD25-20-xxxxx

TURCK Pressure Instrumentation

SPBW06 & DPBW06 series

Heat exchanger. Type WT. For the reheating of airflows in rectangular ducting PD WT 1. 03/2017 DE/en

Return Line Filters Type RTF10/25

Thermistor (NTC /PTC)

High pressure centrifugal pumps

DLG Series. Lowara SPECIFICATIONS APPLICATIONS ACCESSORIES MATERIALS. General Catalogue

4 Way Reversing Valve

C4C-C4H-C4G-C4M MKP Series AXIAL CAPACITORS PCB APPLICATIONS

ZLW Series. Single-stage Monoblock Centrifugal Pump ZL PUMP GROUP.,LTD

65W PWM Output LED Driver. IDLV-65 series. File Name:IDLV-65-SPEC

Accessories 2-WIRE PROGRAMMABLE TRANSMITTERS. 5331D Features: 5333D Features: 5334B Features: Typical Applications: Mounting and Installation:

No item Digit Description Series Reference (1) Meritek Series SI Signal Inductor LI: Leaded Inductor PI: Power Inductor

GAUGE BLOCKS. Grade 0 Tolerance for the variation in length. Limit deviation of length. ± 0.25μm. 0.14μm ±0.80μm. ± 1.90μm. ± 0.40μm. ± 1.

65W PWM Output LED Driver. IDPV-65 series. File Name:IDPV-65-SPEC

Bulletin 1489 UL489 Circuit Breakers

Finish: Anticorrosive finish in polyester. Number of motor poles 4=1400 r/min. 50 Hz 6=900 r/min. 50 Hz 8=750 r/min. 50 Hz

Return Line Filters. Return Line Filters Type RTF10/25. C Technology. Filtration. Product Description. Technical Data. Options and Accessories

HSB Series. 1. Specifications DIN VDE 0110 Concerning clearance and creepage distances DIN VDE 0627 Connectors and plug devices

TRC ELECTRONICS, INC LED Driver Constant Voltage 45W MEAN WELL IDLV-45 Series

Specification. code ±1.0 ±1.0 ±1.0 ±1.0 ±0.5 approx (g)

IDPV-45 series. 45W PWM Output LED Driver. File Name:IDPV-45-SPEC S&E

0.635mm Pitch Board to Board Docking Connector. Lead-Free Compliance

RSDW08 & RDDW08 series

Terminal Contact UL Insulation Designation (provided with) style form system approval Flux tight

4 Way Reversing Valve

38BXCS STANDARD RACK MODEL. DCS Input/Output Relay Card Series MODEL & SUFFIX CODE SELECTION 38BXCS INSTALLATION ORDERING INFORMATION RELATED PRODUCTS

FP series Anti-Bend (Soft termination) capacitor series

Modbus basic setup notes for IO-Link AL1xxx Master Block

Safety Barriers. 6 Safety Barriers KP00 III en Preferred products in stock or available at short notice

B37631 K K 0 60

Aluminum Electrolytic Capacitors (Large Can Type)

MS SERIES MS DESK TOP ENCLOSURE APPLICATION EXAMPLE FEATURE. Measuring instruments. Power supply equipments

QUICKTRONIC PROFESSIONAL QTP5

Lowara SPECIFICATIONS

Model: MTZ22. Data. Cylinder count: 1 Displacement [m³/h]: 6,63 Cylinder capacity [cm³]: 38,1 RPM [min -1 ]: 2900 Weight [kg]: 21 Oil charge [dm³]: 1

Aluminum Electrolytic Capacitors

Precision Metal Film Fixed Resistor Axial Leaded

Metal Oxide Leaded Film Resistor

Applications Water distribution

Overview: Relay Modules

U8 I1. Linearity ±0.10 % f. s.; optional ±0.05 % WB21

Electrical Specifications at T AMB =25 C DC VOLTS (V) MAXIMUM POWER (dbm) DYNAMIC RANGE IP3 (dbm) (db) Output (1 db Comp.) at 2 f U. Typ.

Operating Temperature Range ( C) ±1% (F) ± ~ 1M E-24 NRC /20 (0.05) W 25V 50V ±5% (J) Resistance Tolerance (Code)

IDPV-25 series. 25W PWM Output LED Driver. File Name:IDPV-25-SPEC S&E

MZ0.5GF SERIES ZENER DIODE TECHHICAL SPECIFICATION FEATURES. ABSOLUTE MAXIMUM RATINGE: (Ta=25 ) Parameter Symbols Limits Unit

3 V, 1500 MHz Si MMIC WIDEBAND AMPLIFIER

Lowara APPLICATIONS MATERIALS. General Catalogue

S /5000 BTU/Hr. 1000/1500 Watt

HORIZONTAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS in AISI 304

RF series Ultra High Q & Low ESR capacitor series

Thin Film Chip Resistors

Stamped contacts Crimp male contacts diameter 1,6 mm for wire gauge AWG silver plated Part No. VN (1) Contact Stamped contacts

15W DIN Rail Type DC-DC Converter. DDR-15 series. File Name:DDR-15-SPEC

THICK FILM LEAD FREE CHIP RESISTORS

Oil grooved pads PFO series

2.5 GHz SILICON MMIC WIDE-BAND AMPLIFIER

Strain gauge and rosettes

MZ0.5GN SERIES ZENER DIODE TECHHICAL SPECIFICATION FEATURES. ABSOLUTE MAXIMUM RATINGE: (Ta=25 ) Parameter Symbols Limits Unit

Metal Film Leaded Precision Resistor

First Sensor Quad APD Data Sheet Part Description QA TO Order #

QFLC R0 K - D

15W DIN Rail Type DC-DC Converter. DDR-15 s e r i e s. File Name:DDR-15-SPEC

2010 ASEC INDUSTRIES PTE LTD

U8 I1. Linearity ±0.10 % f. s.; optional ±0.05 % WB85

OWA-60E series IP67. 60W Single Output Moistureproof Adaptor. moistureproof. File Name:OWA-60E-SPEC

Metal Oxide Leaded Film Resistor

Metal thin film chip resistor networks

DATA SHEET Surface mount NTC thermistors. BCcomponents

3 V, 900 MHz Si MMIC AMPLIFIER

3 V, 900 MHz LOW NOISE SI MMIC AMPLIFIER

Stainless steel measuring tape Analog output U8 I1. ±0.10 % f. s. (standard); ±0.05 % (optional) Protection class IP68/IP69K

Gearmotor Data. SERIES GM9000: We have the GM9434H187-R1

Data sheet Thick Film Chip Resistor 5% - RS Series 0201/0402/0603/0805/1206

Shunts & Multiple Shunts. Stamped Contact DIP IC Sockets. PLCC Sockets. Jumpers. DDR DIMM Sockets SOCKETS. System CS - Technical Specifications

± 20% ± 5% ± 10% RENCO ELECTRONICS, INC.

CSR series. Thick Film Chip Resistor Current Sensing Type FEATURE PART NUMBERING SYSTEM ELECTRICAL CHARACTERISTICS

SMD Transient Voltage Suppressors

Ceramic PTC Thermistor Overload Protection

Features. Terminal Contact Enclosure style style form Open type Dust cover Ears on cover Antirotation-tab Ears on top

DC-DC Constant Current Step-Down LED driver LDD-300L LDD-350L LDD-500L LDD-600L LDD-700L CURRENT RANGE

SMB SERIES Subminiature Coaxial Connectors

High hydraulic efficiency Motor designed to EN standards IDENTIFICATION NAME. F - in line ports with ROUND FLANGES (counterflanges on request)

2R2. 2 (L W H) [mm] Wire Wound SMD Power Inductor. Nominal Inductance Packing Tape & Reel. Design Code M ±20%

the total number of electrons passing through the lamp.

SERIES DATASHEET INDUCTORS RF INDUCTORS (MRFI SERIES)

Contactors & Thermal Overload Relays

Metal Oxide Varistors (MOV) Data Sheet

[1] P Q. Fig. 3.1

PEH C High CV-value Long Life, > 10 years at 50 C Low ESR and ESL High stability, 10 years shelf life

SMD Wire Wound Ferrite Chip Inductors - LS Series. LS Series. Product Identification. Shape and Dimensions / Recommended Pattern LS0402/0603/0805/1008

Shape Square. Tolerance of Varistor Voltage For Varistor voltage<68, Special For Varistor voltage 68, 10% Lead Wire Type Straight Cut Lead

NMBTC.COM /

Digital motor protection relays

Transcript:

*0900581* DB_EN_ME12 Rev.B 06/1 *0900581* d e v e l o p i n g s o l u t i o n s ME12 Datasheet Remotely Configurable Digital Pressure Transmitter Application Pressure transmitter with a ceramic measuring cell is designed for measuring positive and negative pressures. Gauge pressure range from -1 0 bar to 0 60 bar. Absolute pressure range from 0 1 bar to 0 16 bar Pressure transmitters from this series are suitable for a wide variety of measuring tasks in the fields of: Process engineering Process technology Environmental engineering Construction and mode of operation The pressure being measured acts directly on the ceramic diaphragm, causing it to distort. That in turn alters the resistance of the strain gauge on the rear of the diaphragm in proportion to the level of distortion. Electronics in the pressure transmitter housing convert the change in resistance into standard electrical signals. Function diagram Features Configurable Robust housing design High accuracy Low hysteresis Parameterisation The device is supplied as defined in the ordering code. Nevertheless, to optimise performance in line with prevailing process conditions it is also possible to configure the pressure transmitter on-site via the connection cables. To do so you will require a PC as well as the programming adapter EU13, available as an accessory. Pos Description 1 Ceramic sensor 2 Electronics 3 Power Supply Output signal

2 2 5 5 10 20 20 0...1 0...1,6 0...2,5 0... 0...6 0...10 0...16 10 20 0 0 100 10 12 20 0 0 100 100 200-1...0-1...+0,6-1...+1,5-1...+3-1...+5-1...+9-1...+15-1...+2 0...0,6 0...1 0...1,6 0...2,5 0... 0...6 0...10 0...16 0...25 0...0 0...60 Technical data Relative pressure measuring range [bar] Overload pressure safety [bar] Absolute pressure measuring range [bar] Overload pressure safety [bar] General: Linearity Hysteresis < 1.0 % FS (optionally < 0.5 %FS) < 0.5 % FS Permissible ambient temperature -10 C...+70 C Permissible continuous media temperature Pressure connection Electrical connection -10 C...+85 C See order code Line socket DIN EN 175 301-803-A or M12 plug connector DIN EN 61076-2-101 Protection class IP 65 according to DIN EN 60 529 Materials in contact with media Chromium nickel steel 1.0, ceramic Al 2O 3, see order code for seal Casing materials Chromium nickel steel 1.305 Electrical Data: 2-wire current output 3-wire voltage output 3-wire current output Rated voltage 2 VDC 2 VAC/DC 2 VAC/DC Permissible supply voltage U b 6...30 VDC 15...30 VAC/DC 15...30 VAC/DC Output signal...20 ma 0...10 VDC 0...20 ma...20 ma Limit of the output signal ca. 26 ma ca. 10.5 VDC ca. 23 ma Apparent ohmic resistance (U b - 6V) / 0.02A 5 kω ab 15 VDC 2 kω ab 20 VDC Zero-point temperature drift 0.07 % FS/K 0.07 % FS/K 0.07 % FS/K Measuring range temperature drift 0.05 % FS/K 0.05 % FS/K 0.05 % FS/K [(U b - 10V) / 0.02A] + 300 Ω Configuration: Characteristic curve inversion Attenuation Adjustable signal limits Offset correction Span correction Increasing / decreasing 0...200 s Uppers current limit 3.5...22.5 ma Lower current limit 3.5...22.5 ma Error signal 3.5...22.5 ma +/-25 %FS +/-25 %FS 2 S e i t e

Dimensioned drawings Possible electrical connections: (Al units in mm else stated otherwise) Line socket DIN EN 175 301-803 A M12 Connector DIN EN 61076-2-101 Screwed cable gland Possible Pressure Connections: Line socket DIN EN 175 301-803 A Near flush-mounted front sensor HEX 1mm A/F HEX 32mm A/F HEX 27mm A/F 3 S e i t e

Field housing: Screwed cable gland M16 x 1.5 M12 Connector M12 x 1 Electrical connection Rectangular connector according to DIN EN 175 301-803-A Male socket on unit side Line socket 2-wire circuit 1 Power Supply/Output +U b +Sig brown 2 Power Supply/Output - U b - Sig blue 3 not connected black not connected green/yellow 3-wire circuit 1 Output +Sig brown 2 Power Supply/Output - U b - Sig blue 3 Power Supply +U b black not connected green/yellow S e i t e

Round shell connector M12 according to DIN EN 61076-2-101 Male socket on unit side Cable with M12 female cable plug 2-wire circuit 1 Power Supply/Output +U b +Sig brown 2 not connected white 3 Power Supply/Output - U b - Sig blue not connected black 3-wire circuit 1 Power Supply +U b brown 2 not connected white 3 Power Supply/Output - U b - Sig blue Output +Sig black Screwed cable gland Mini COMBICON terminal block 2-wire circuit 1 Power Supply/Output +U b +Sig brown 2 not connected white 3 Power Supply/Output - U b - Sig blue not connected black 3-wire circuit 1 Power Supply +U b brown 2 Output +Sig white 3 Power Supply/Output - U b - Sig blue not connected black 5 S e i t e

Ordering code Remotely Configurable Digital Pressure Transmitter ME12 0 Measuring Ranges 0... 0,6 bar... > 0 1 0 1 bar... > 0 2 0 1,6 bar... > 0 3 0... 2,5 bar... > 0 0... bar... > 0 5 0... 6 bar... > 0 6 0... 10 bar... > 0 7 0... 16 bar... > 0 8 0... 25 bar... > 0 9 0... 0 bar... > 1 0 0... 60 bar... > 1 1-1... 0 bar... > 3 1-1... 0,6 bar... > 3 2-1... 1,5 bar... > 3 3-1... 3 bar... > 3-1... 5 bar... > 3 5-1... 9 bar... > 3 6-1... 15 bar... > 3 7-1... 2 bar... > 3 8 0-1 bar... > 3 9 Measuring Accuracy Characteristic curve deviation relative pressure 1.0%... > M Characteristic curve deviation relative pressure 0.5%... > 0 Characteristic curve deviation absolute pressure 1.0%... > S Characteristic curve deviation absolute pressure 0.5%... > T Pressure Connection Connection shanks G¼ B; material 1.0... > 8 5 Connection shanks G½ B; material 1.0... > 8 7 Connection shanks with external thread ¼ -18 NPT EXT, 1.0... > 8 8 Connection for Schrader fitting, 1.0... > S 1 G 1 B with near flush-mounted front pressure sensor, 1.0... > A 3 G ¾ B with near flush-mounted front pressure sensor, 1.0... > A 8 Electrical Output Signal 0... 20 ma Three-wire... > A... 20 ma Three-wire... > P 0... 10 V Three-wire... > C 1... 5 V Three-wire... > D... 20 ma Two-wire... > B Electrical Connection -pole Line socket DIN EN 175 301-803-A... > H -pole circular plug connector M12 DIN EN 61076-2-101... > M Cable gland M16x1.5 (only with field housing possible)... > 0 Operating Voltage 2 VDC (with two-wire only)... > 9 2 VAC/VDC (with three-wire only)... > L Casing IP65 as per DIN EN 60 529... > 0 IP65 as per DIN EN 60 529; encapsulated model... > V IP65 as per DIN EN 60 529; encapsulated model; Field Housing... > F Media-Contact Seal FKM (Fluororubber, Viton )... > V CR (Chloroprene rubber, Neoprene )... > C EPDM (Ethylene propylene diene rubber)... > E H-NBR (Hydrogenated nitrile rubber),deployable to -25 C... > H FFPM (Perfluororubber, Kalrez )... > K Measuring System / Type Standard... > 0 Suitable for O 2 measurement (FKM seal only)... > 3 Silicone-free model... > A Accessories For the marked measuring range only Order Code Description No. of Poles Application Length EU13.F200 USB transmitter PC interface incl. PC software for 2-wire transmitter EU03.F300 USB transmitter PC interface incl. PC software for 3-wire transmitter 0601993 Connection cable with M12 connector -pole for supply / signal 2 m 060199 Connection cable with M12 connector -pole for supply / signal 5 m 6 S e i t e

7 S e i t e

Technische Änderungen vorbehalten Subject to change without notice Changements techniques sous réserve Fischer Mess- und Regeltechnik GmbH Bielefelder Str. 37a D-32107 Bad Salzuflen Tel. +9 5222 970 Fax +9 5222 7170 email: info@fischermesstechnik.de www.fischermesstechnik.de